Use of novel picolinoyl derivatization for simultaneous quantification of six corticosteroids by liquid chromatography-electrospray ionization tandem mass spectrometry

Simultaneous quantification method of six corticosteroids, cortisone, cortisol, cortexolone, corticosterone, dehydrocorticosterone and deoxycorticosterone, by LC–electrospray ionization (ESI)-MS in a positive mode using novel picolinoyl derivatization was investigated. Conversion of each corticoster...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Journal of Chromatography A 2007-11, Vol.1173 (1), p.120-128
Hauptverfasser: Yamashita, Kouwa, Takahashi, Madoka, Tsukamoto, Satoshi, Numazawa, Mitsuteru, Okuyama, Mitsunobu, Honma, Seijiro
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 128
container_issue 1
container_start_page 120
container_title Journal of Chromatography A
container_volume 1173
creator Yamashita, Kouwa
Takahashi, Madoka
Tsukamoto, Satoshi
Numazawa, Mitsuteru
Okuyama, Mitsunobu
Honma, Seijiro
description Simultaneous quantification method of six corticosteroids, cortisone, cortisol, cortexolone, corticosterone, dehydrocorticosterone and deoxycorticosterone, by LC–electrospray ionization (ESI)-MS in a positive mode using novel picolinoyl derivatization was investigated. Conversion of each corticosteroid into the corresponding picolinoyl derivative was performed by mixed anhydride method using picolinic acids and 2-methyl-6-nitrobenzoic anhydride. Derivatization proceeded smoothly to afford the corresponding 21-monopicolinoyl derivatives. Positive ion-ESI mass spectra of the picolinoyl derivatives were dominated by the appearance of [ M + H] + as base peaks. The picolinoyl derivatives provided 5–10 times higher ESI response in the LC–ESI-MS-selected reaction monitoring (SRM) when compared to those of underivatized molecules in a positive LC–ESI-MS mode. The use of the picolinoyl ester, solid-phase extraction, and deuterium labeled internal standards enabled to determine the concentrations of these corticosteroids in human saliva simultaneously by LC–ESI-MS-SRM.
doi_str_mv 10.1016/j.chroma.2007.10.023
format Article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_68495086</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><els_id>S002196730701744X</els_id><sourcerecordid>68495086</sourcerecordid><originalsourceid>FETCH-LOGICAL-c456t-2606fae40f24c67faa28d3cf7b5dc4cc8c7f53c554e8951a2cf9a66864ef38f73</originalsourceid><addsrcrecordid>eNp9kU2O1DAQhbMAMcPADRDyBnZpnMSxkw0SGvEnjcSGWVvuSplxy4nTLqdFuBDXxE0azY6FZan81fOrekXxquK7ilfy3WEHDzGMZldzrnJpx-vmSXHNeV2VvVTNVfGc6MB5pbiqnxVXleqlaDtxXfy-J2TBsimc0LPZQfBuCqtnA0Z3Msn9yidMzIbIyI2LT2bCsBA7LmZKzjrY3rMEuZ8MQkxZgxLG4AZi-5V5d1zcwDaDKfyIZn5YS_QIKQaao1lZFvj3T5YfcGSjIWI0_2VGTHF9UTy1xhO-vNw3xf2nj99vv5R33z5_vf1wV4JoZSpryaU1KLitBUhljam7oQGr9u0AAqADZdsG2lZg17eVqcH2RspOCrRNZ1VzU7zddOcYjgtS0qMjQO-3sbXsRN_yTmZQbCDkKSii1XN0o4mrrrg-h6IPeptZn0M5V3Moue31RX_Zjzg8Nl0SycCbC2AIjLfRTODoketrwVV1Nvp-4zBv4-QwagKHE-DgYl6bHoL7v5M_LJu2Mg</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>68495086</pqid></control><display><type>article</type><title>Use of novel picolinoyl derivatization for simultaneous quantification of six corticosteroids by liquid chromatography-electrospray ionization tandem mass spectrometry</title><source>MEDLINE</source><source>Elsevier ScienceDirect Journals</source><creator>Yamashita, Kouwa ; Takahashi, Madoka ; Tsukamoto, Satoshi ; Numazawa, Mitsuteru ; Okuyama, Mitsunobu ; Honma, Seijiro</creator><creatorcontrib>Yamashita, Kouwa ; Takahashi, Madoka ; Tsukamoto, Satoshi ; Numazawa, Mitsuteru ; Okuyama, Mitsunobu ; Honma, Seijiro</creatorcontrib><description>Simultaneous quantification method of six corticosteroids, cortisone, cortisol, cortexolone, corticosterone, dehydrocorticosterone and deoxycorticosterone, by LC–electrospray ionization (ESI)-MS in a positive mode using novel picolinoyl derivatization was investigated. Conversion of each corticosteroid into the corresponding picolinoyl derivative was performed by mixed anhydride method using picolinic acids and 2-methyl-6-nitrobenzoic anhydride. Derivatization proceeded smoothly to afford the corresponding 21-monopicolinoyl derivatives. Positive ion-ESI mass spectra of the picolinoyl derivatives were dominated by the appearance of [ M + H] + as base peaks. The picolinoyl derivatives provided 5–10 times higher ESI response in the LC–ESI-MS-selected reaction monitoring (SRM) when compared to those of underivatized molecules in a positive LC–ESI-MS mode. The use of the picolinoyl ester, solid-phase extraction, and deuterium labeled internal standards enabled to determine the concentrations of these corticosteroids in human saliva simultaneously by LC–ESI-MS-SRM.</description><identifier>ISSN: 0021-9673</identifier><identifier>DOI: 10.1016/j.chroma.2007.10.023</identifier><identifier>PMID: 17964584</identifier><identifier>CODEN: JOCRAM</identifier><language>eng</language><publisher>Amsterdam: Elsevier B.V</publisher><subject>Adrenal Cortex Hormones - analysis ; Adrenal Cortex Hormones - chemistry ; Analysis ; Biological and medical sciences ; Chromatography, High Pressure Liquid - methods ; Electrospray ionization ; General pharmacology ; Humans ; Liquid chromatography-tandem mass spectrometry ; Medical sciences ; Molecular Structure ; Pharmacology. Drug treatments ; Picolinic Acids - chemistry ; Picolinoyl derivative ; Reproducibility of Results ; Saliva - chemistry ; Salivary corticosteroids ; Spectrometry, Mass, Electrospray Ionization - methods ; Tandem Mass Spectrometry - methods</subject><ispartof>Journal of Chromatography A, 2007-11, Vol.1173 (1), p.120-128</ispartof><rights>2007 Elsevier B.V.</rights><rights>2008 INIST-CNRS</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c456t-2606fae40f24c67faa28d3cf7b5dc4cc8c7f53c554e8951a2cf9a66864ef38f73</citedby><cites>FETCH-LOGICAL-c456t-2606fae40f24c67faa28d3cf7b5dc4cc8c7f53c554e8951a2cf9a66864ef38f73</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://www.sciencedirect.com/science/article/pii/S002196730701744X$$EHTML$$P50$$Gelsevier$$H</linktohtml><link.rule.ids>314,776,780,3537,27901,27902,65306</link.rule.ids><backlink>$$Uhttp://pascal-francis.inist.fr/vibad/index.php?action=getRecordDetail&amp;idt=19240717$$DView record in Pascal Francis$$Hfree_for_read</backlink><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/17964584$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Yamashita, Kouwa</creatorcontrib><creatorcontrib>Takahashi, Madoka</creatorcontrib><creatorcontrib>Tsukamoto, Satoshi</creatorcontrib><creatorcontrib>Numazawa, Mitsuteru</creatorcontrib><creatorcontrib>Okuyama, Mitsunobu</creatorcontrib><creatorcontrib>Honma, Seijiro</creatorcontrib><title>Use of novel picolinoyl derivatization for simultaneous quantification of six corticosteroids by liquid chromatography-electrospray ionization tandem mass spectrometry</title><title>Journal of Chromatography A</title><addtitle>J Chromatogr A</addtitle><description>Simultaneous quantification method of six corticosteroids, cortisone, cortisol, cortexolone, corticosterone, dehydrocorticosterone and deoxycorticosterone, by LC–electrospray ionization (ESI)-MS in a positive mode using novel picolinoyl derivatization was investigated. Conversion of each corticosteroid into the corresponding picolinoyl derivative was performed by mixed anhydride method using picolinic acids and 2-methyl-6-nitrobenzoic anhydride. Derivatization proceeded smoothly to afford the corresponding 21-monopicolinoyl derivatives. Positive ion-ESI mass spectra of the picolinoyl derivatives were dominated by the appearance of [ M + H] + as base peaks. The picolinoyl derivatives provided 5–10 times higher ESI response in the LC–ESI-MS-selected reaction monitoring (SRM) when compared to those of underivatized molecules in a positive LC–ESI-MS mode. The use of the picolinoyl ester, solid-phase extraction, and deuterium labeled internal standards enabled to determine the concentrations of these corticosteroids in human saliva simultaneously by LC–ESI-MS-SRM.</description><subject>Adrenal Cortex Hormones - analysis</subject><subject>Adrenal Cortex Hormones - chemistry</subject><subject>Analysis</subject><subject>Biological and medical sciences</subject><subject>Chromatography, High Pressure Liquid - methods</subject><subject>Electrospray ionization</subject><subject>General pharmacology</subject><subject>Humans</subject><subject>Liquid chromatography-tandem mass spectrometry</subject><subject>Medical sciences</subject><subject>Molecular Structure</subject><subject>Pharmacology. Drug treatments</subject><subject>Picolinic Acids - chemistry</subject><subject>Picolinoyl derivative</subject><subject>Reproducibility of Results</subject><subject>Saliva - chemistry</subject><subject>Salivary corticosteroids</subject><subject>Spectrometry, Mass, Electrospray Ionization - methods</subject><subject>Tandem Mass Spectrometry - methods</subject><issn>0021-9673</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2007</creationdate><recordtype>article</recordtype><sourceid>EIF</sourceid><recordid>eNp9kU2O1DAQhbMAMcPADRDyBnZpnMSxkw0SGvEnjcSGWVvuSplxy4nTLqdFuBDXxE0azY6FZan81fOrekXxquK7ilfy3WEHDzGMZldzrnJpx-vmSXHNeV2VvVTNVfGc6MB5pbiqnxVXleqlaDtxXfy-J2TBsimc0LPZQfBuCqtnA0Z3Msn9yidMzIbIyI2LT2bCsBA7LmZKzjrY3rMEuZ8MQkxZgxLG4AZi-5V5d1zcwDaDKfyIZn5YS_QIKQaao1lZFvj3T5YfcGSjIWI0_2VGTHF9UTy1xhO-vNw3xf2nj99vv5R33z5_vf1wV4JoZSpryaU1KLitBUhljam7oQGr9u0AAqADZdsG2lZg17eVqcH2RspOCrRNZ1VzU7zddOcYjgtS0qMjQO-3sbXsRN_yTmZQbCDkKSii1XN0o4mrrrg-h6IPeptZn0M5V3Moue31RX_Zjzg8Nl0SycCbC2AIjLfRTODoketrwVV1Nvp-4zBv4-QwagKHE-DgYl6bHoL7v5M_LJu2Mg</recordid><startdate>20071130</startdate><enddate>20071130</enddate><creator>Yamashita, Kouwa</creator><creator>Takahashi, Madoka</creator><creator>Tsukamoto, Satoshi</creator><creator>Numazawa, Mitsuteru</creator><creator>Okuyama, Mitsunobu</creator><creator>Honma, Seijiro</creator><general>Elsevier B.V</general><general>Elsevier</general><scope>IQODW</scope><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope></search><sort><creationdate>20071130</creationdate><title>Use of novel picolinoyl derivatization for simultaneous quantification of six corticosteroids by liquid chromatography-electrospray ionization tandem mass spectrometry</title><author>Yamashita, Kouwa ; Takahashi, Madoka ; Tsukamoto, Satoshi ; Numazawa, Mitsuteru ; Okuyama, Mitsunobu ; Honma, Seijiro</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c456t-2606fae40f24c67faa28d3cf7b5dc4cc8c7f53c554e8951a2cf9a66864ef38f73</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2007</creationdate><topic>Adrenal Cortex Hormones - analysis</topic><topic>Adrenal Cortex Hormones - chemistry</topic><topic>Analysis</topic><topic>Biological and medical sciences</topic><topic>Chromatography, High Pressure Liquid - methods</topic><topic>Electrospray ionization</topic><topic>General pharmacology</topic><topic>Humans</topic><topic>Liquid chromatography-tandem mass spectrometry</topic><topic>Medical sciences</topic><topic>Molecular Structure</topic><topic>Pharmacology. Drug treatments</topic><topic>Picolinic Acids - chemistry</topic><topic>Picolinoyl derivative</topic><topic>Reproducibility of Results</topic><topic>Saliva - chemistry</topic><topic>Salivary corticosteroids</topic><topic>Spectrometry, Mass, Electrospray Ionization - methods</topic><topic>Tandem Mass Spectrometry - methods</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Yamashita, Kouwa</creatorcontrib><creatorcontrib>Takahashi, Madoka</creatorcontrib><creatorcontrib>Tsukamoto, Satoshi</creatorcontrib><creatorcontrib>Numazawa, Mitsuteru</creatorcontrib><creatorcontrib>Okuyama, Mitsunobu</creatorcontrib><creatorcontrib>Honma, Seijiro</creatorcontrib><collection>Pascal-Francis</collection><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><jtitle>Journal of Chromatography A</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Yamashita, Kouwa</au><au>Takahashi, Madoka</au><au>Tsukamoto, Satoshi</au><au>Numazawa, Mitsuteru</au><au>Okuyama, Mitsunobu</au><au>Honma, Seijiro</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Use of novel picolinoyl derivatization for simultaneous quantification of six corticosteroids by liquid chromatography-electrospray ionization tandem mass spectrometry</atitle><jtitle>Journal of Chromatography A</jtitle><addtitle>J Chromatogr A</addtitle><date>2007-11-30</date><risdate>2007</risdate><volume>1173</volume><issue>1</issue><spage>120</spage><epage>128</epage><pages>120-128</pages><issn>0021-9673</issn><coden>JOCRAM</coden><abstract>Simultaneous quantification method of six corticosteroids, cortisone, cortisol, cortexolone, corticosterone, dehydrocorticosterone and deoxycorticosterone, by LC–electrospray ionization (ESI)-MS in a positive mode using novel picolinoyl derivatization was investigated. Conversion of each corticosteroid into the corresponding picolinoyl derivative was performed by mixed anhydride method using picolinic acids and 2-methyl-6-nitrobenzoic anhydride. Derivatization proceeded smoothly to afford the corresponding 21-monopicolinoyl derivatives. Positive ion-ESI mass spectra of the picolinoyl derivatives were dominated by the appearance of [ M + H] + as base peaks. The picolinoyl derivatives provided 5–10 times higher ESI response in the LC–ESI-MS-selected reaction monitoring (SRM) when compared to those of underivatized molecules in a positive LC–ESI-MS mode. The use of the picolinoyl ester, solid-phase extraction, and deuterium labeled internal standards enabled to determine the concentrations of these corticosteroids in human saliva simultaneously by LC–ESI-MS-SRM.</abstract><cop>Amsterdam</cop><pub>Elsevier B.V</pub><pmid>17964584</pmid><doi>10.1016/j.chroma.2007.10.023</doi><tpages>9</tpages></addata></record>
fulltext fulltext
identifier ISSN: 0021-9673
ispartof Journal of Chromatography A, 2007-11, Vol.1173 (1), p.120-128
issn 0021-9673
language eng
recordid cdi_proquest_miscellaneous_68495086
source MEDLINE; Elsevier ScienceDirect Journals
subjects Adrenal Cortex Hormones - analysis
Adrenal Cortex Hormones - chemistry
Analysis
Biological and medical sciences
Chromatography, High Pressure Liquid - methods
Electrospray ionization
General pharmacology
Humans
Liquid chromatography-tandem mass spectrometry
Medical sciences
Molecular Structure
Pharmacology. Drug treatments
Picolinic Acids - chemistry
Picolinoyl derivative
Reproducibility of Results
Saliva - chemistry
Salivary corticosteroids
Spectrometry, Mass, Electrospray Ionization - methods
Tandem Mass Spectrometry - methods
title Use of novel picolinoyl derivatization for simultaneous quantification of six corticosteroids by liquid chromatography-electrospray ionization tandem mass spectrometry
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-02-03T06%3A30%3A00IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Use%20of%20novel%20picolinoyl%20derivatization%20for%20simultaneous%20quantification%20of%20six%20corticosteroids%20by%20liquid%20chromatography-electrospray%20ionization%20tandem%20mass%20spectrometry&rft.jtitle=Journal%20of%20Chromatography%20A&rft.au=Yamashita,%20Kouwa&rft.date=2007-11-30&rft.volume=1173&rft.issue=1&rft.spage=120&rft.epage=128&rft.pages=120-128&rft.issn=0021-9673&rft.coden=JOCRAM&rft_id=info:doi/10.1016/j.chroma.2007.10.023&rft_dat=%3Cproquest_cross%3E68495086%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=68495086&rft_id=info:pmid/17964584&rft_els_id=S002196730701744X&rfr_iscdi=true