Response of atrial fibrillation to pulmonary vein antrum isolation is directly related to resumption and delay of pulmonary vein conduction

The role of pulmonary vein (PV) isolation in ablative treatment of atrial fibrillation (AF) has been debated in conflicting reports. We sought to compare PV conduction in patients who had no AF recurrence (group I), patients who could maintain sinus rhythm on antiarrhythmic medication (group II), an...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Circulation (New York, N.Y.) N.Y.), 2005-08, Vol.112 (5), p.627-635
Hauptverfasser: VERMA, Atul, KILICASLAN, Fethi, BURKHARDT, J. David, SALIBA, Walid, SCHWEIKERT, Robert A, NATALE, Andrea, PISANO, Ennio, MARROUCHE, Nassir F, FANELLI, Raffaele, BRACHMANN, Johannes, GEUNTHER, Jens, POTENZA, Domenico, MARTIN, David O, CUMMINGS, Jennifer
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:The role of pulmonary vein (PV) isolation in ablative treatment of atrial fibrillation (AF) has been debated in conflicting reports. We sought to compare PV conduction in patients who had no AF recurrence (group I), patients who could maintain sinus rhythm on antiarrhythmic medication (group II), and patients who had recurrent AF despite antiarrhythmic medication (group III) after PV antrum isolation (PVAI). PV conduction was examined in consecutive patients undergoing second PVAI for AF recurrence. We also recruited some patients cured of AF to undergo a repeat, limited electrophysiological study at >3 months after PVAI. All patients underwent PVAI with an intracardiac echocardiography (ICE)-guided approach with complete isolation of all 4 PV antra (PVA). The number of PVs with recurrent conduction and the shortest atrial to PV (A-PV) conduction delay was measured with the use of consistent Lasso positions defined by ICE. Late AF recurrence was defined as AF >2 months after PVAI with the patient off medications. Patients in groups I (n=26), II (n=37), and III (n=44) did not differ at baseline (38% permanent AF; ejection fraction 53+/-6%). Recurrence of PV-left atrial (LA) conduction was seen in 1.7+/-0.8 and 2.2+/-0.8 PVAs for groups II and III but only in 0.2+/-0.4 for group I (P=0.02). In patients with recurrent PV-LA conduction, the A-PV delay increased from the first to second procedure by 69+/-47% for group III, 267+/-110% for group II, and 473+/-71% for group I (P
ISSN:0009-7322
1524-4539
DOI:10.1161/circulationaha.104.533190