Multiple internal reflection poly(dimethylsiloxane) systems for optical sensing
Compact poly(dimethylsiloxane)-based (PDMS) multiple internal reflection systems which comprise self-alignment systems, lenses, microfluidic channels and mirrors have been developed for highly sensitive absorbance measurements. With the proper definition of air mirrors at both sides of the sensing r...
Gespeichert in:
Veröffentlicht in: | Lab on a chip 2007-01, Vol.7 (11), p.1560-1566 |
---|---|
Hauptverfasser: | , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
container_end_page | 1566 |
---|---|
container_issue | 11 |
container_start_page | 1560 |
container_title | Lab on a chip |
container_volume | 7 |
creator | Llobera, A Demming, S Wilke, R Büttgenbach, S |
description | Compact poly(dimethylsiloxane)-based (PDMS) multiple internal reflection systems which comprise self-alignment systems, lenses, microfluidic channels and mirrors have been developed for highly sensitive absorbance measurements. With the proper definition of air mirrors at both sides of the sensing region, the optical path of the light from the LED has been meaningfully lengthened without a dramatic increase of the mean flow cell volume. By recursive positioning of such air mirrors, propagating multiple internal reflection (PMIR) systems have been designed, simulated and characterized. Experimental results confirm the ray-tracing predictions and allow the determining that there are some regions of the mean flow cell volume that do not contribute to the increase of the sensitivity. The tailoring of the sensing region, following the optical path, results in a similar limit of detection (110 nM) for fluorescein diluted in phosphate buffer. Finally, a ring configuration, labelled RMIR, has also been developed. With the addition of a third air mirror, the LOD can be decreased to 41 nM with the additional advantage of a substantial decrease of the length of the sensing region. These results confirm the validity of the proposed systems for high sensitivity measurements. |
doi_str_mv | 10.1039/b704454b |
format | Article |
fullrecord | <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_68430809</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>34993407</sourcerecordid><originalsourceid>FETCH-LOGICAL-c332t-c4f5fe46e68894e4b557acdd7eaf17c489627ac96235e8219699609ebbda372f3</originalsourceid><addsrcrecordid>eNqFkE1LxDAQhoMo7roK_gLpSdZDNWnSfBxl8QtW9qLn0qZTjaRNbVLY_nsju-rRy8wwPDO8PAidE3xNMFU3lcCM5aw6QHPCBE0xkerwd1Zihk68_8CY5IzLYzQjQnGcST5Hm-fRBtNbSEwXYOhKmwzQWNDBuC7pnZ2WtWkhvE_WG-u2ZQdXiZ98gNYnjRsS1wej45WHzpvu7RQdNaX1cLbvC_R6f_eyekzXm4en1e061ZRmIdWsyRtgHLiUigGr8lyUuq4FlA0RmknFs7iIleYgM6K4iokVVFVdUpE1dIEud3_7wX2O4EPRGq_B2hjQjb7gklEssfoXpEwpyrCI4HIH6sF5HyUU_WDacpgKgotvy8WP5Yhe7H-OVQv1H7jXSr8AuIR4Yg</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>34993407</pqid></control><display><type>article</type><title>Multiple internal reflection poly(dimethylsiloxane) systems for optical sensing</title><source>Royal Society of Chemistry Journals Archive (1841-2007)</source><source>MEDLINE</source><source>Royal Society Of Chemistry Journals 2008-</source><source>Alma/SFX Local Collection</source><creator>Llobera, A ; Demming, S ; Wilke, R ; Büttgenbach, S</creator><creatorcontrib>Llobera, A ; Demming, S ; Wilke, R ; Büttgenbach, S</creatorcontrib><description>Compact poly(dimethylsiloxane)-based (PDMS) multiple internal reflection systems which comprise self-alignment systems, lenses, microfluidic channels and mirrors have been developed for highly sensitive absorbance measurements. With the proper definition of air mirrors at both sides of the sensing region, the optical path of the light from the LED has been meaningfully lengthened without a dramatic increase of the mean flow cell volume. By recursive positioning of such air mirrors, propagating multiple internal reflection (PMIR) systems have been designed, simulated and characterized. Experimental results confirm the ray-tracing predictions and allow the determining that there are some regions of the mean flow cell volume that do not contribute to the increase of the sensitivity. The tailoring of the sensing region, following the optical path, results in a similar limit of detection (110 nM) for fluorescein diluted in phosphate buffer. Finally, a ring configuration, labelled RMIR, has also been developed. With the addition of a third air mirror, the LOD can be decreased to 41 nM with the additional advantage of a substantial decrease of the length of the sensing region. These results confirm the validity of the proposed systems for high sensitivity measurements.</description><identifier>ISSN: 1473-0197</identifier><identifier>EISSN: 1473-0189</identifier><identifier>DOI: 10.1039/b704454b</identifier><identifier>PMID: 17960286</identifier><language>eng</language><publisher>England</publisher><subject>Dimethylpolysiloxanes - chemistry ; Optics and Photonics ; Sensitivity and Specificity ; Silicones - chemistry</subject><ispartof>Lab on a chip, 2007-01, Vol.7 (11), p.1560-1566</ispartof><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c332t-c4f5fe46e68894e4b557acdd7eaf17c489627ac96235e8219699609ebbda372f3</citedby><cites>FETCH-LOGICAL-c332t-c4f5fe46e68894e4b557acdd7eaf17c489627ac96235e8219699609ebbda372f3</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,776,780,2818,27903,27904</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/17960286$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Llobera, A</creatorcontrib><creatorcontrib>Demming, S</creatorcontrib><creatorcontrib>Wilke, R</creatorcontrib><creatorcontrib>Büttgenbach, S</creatorcontrib><title>Multiple internal reflection poly(dimethylsiloxane) systems for optical sensing</title><title>Lab on a chip</title><addtitle>Lab Chip</addtitle><description>Compact poly(dimethylsiloxane)-based (PDMS) multiple internal reflection systems which comprise self-alignment systems, lenses, microfluidic channels and mirrors have been developed for highly sensitive absorbance measurements. With the proper definition of air mirrors at both sides of the sensing region, the optical path of the light from the LED has been meaningfully lengthened without a dramatic increase of the mean flow cell volume. By recursive positioning of such air mirrors, propagating multiple internal reflection (PMIR) systems have been designed, simulated and characterized. Experimental results confirm the ray-tracing predictions and allow the determining that there are some regions of the mean flow cell volume that do not contribute to the increase of the sensitivity. The tailoring of the sensing region, following the optical path, results in a similar limit of detection (110 nM) for fluorescein diluted in phosphate buffer. Finally, a ring configuration, labelled RMIR, has also been developed. With the addition of a third air mirror, the LOD can be decreased to 41 nM with the additional advantage of a substantial decrease of the length of the sensing region. These results confirm the validity of the proposed systems for high sensitivity measurements.</description><subject>Dimethylpolysiloxanes - chemistry</subject><subject>Optics and Photonics</subject><subject>Sensitivity and Specificity</subject><subject>Silicones - chemistry</subject><issn>1473-0197</issn><issn>1473-0189</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2007</creationdate><recordtype>article</recordtype><sourceid>EIF</sourceid><recordid>eNqFkE1LxDAQhoMo7roK_gLpSdZDNWnSfBxl8QtW9qLn0qZTjaRNbVLY_nsju-rRy8wwPDO8PAidE3xNMFU3lcCM5aw6QHPCBE0xkerwd1Zihk68_8CY5IzLYzQjQnGcST5Hm-fRBtNbSEwXYOhKmwzQWNDBuC7pnZ2WtWkhvE_WG-u2ZQdXiZ98gNYnjRsS1wej45WHzpvu7RQdNaX1cLbvC_R6f_eyekzXm4en1e061ZRmIdWsyRtgHLiUigGr8lyUuq4FlA0RmknFs7iIleYgM6K4iokVVFVdUpE1dIEud3_7wX2O4EPRGq_B2hjQjb7gklEssfoXpEwpyrCI4HIH6sF5HyUU_WDacpgKgotvy8WP5Yhe7H-OVQv1H7jXSr8AuIR4Yg</recordid><startdate>20070101</startdate><enddate>20070101</enddate><creator>Llobera, A</creator><creator>Demming, S</creator><creator>Wilke, R</creator><creator>Büttgenbach, S</creator><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7SP</scope><scope>7TB</scope><scope>7U5</scope><scope>8FD</scope><scope>FR3</scope><scope>L7M</scope><scope>7X8</scope></search><sort><creationdate>20070101</creationdate><title>Multiple internal reflection poly(dimethylsiloxane) systems for optical sensing</title><author>Llobera, A ; Demming, S ; Wilke, R ; Büttgenbach, S</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c332t-c4f5fe46e68894e4b557acdd7eaf17c489627ac96235e8219699609ebbda372f3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2007</creationdate><topic>Dimethylpolysiloxanes - chemistry</topic><topic>Optics and Photonics</topic><topic>Sensitivity and Specificity</topic><topic>Silicones - chemistry</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Llobera, A</creatorcontrib><creatorcontrib>Demming, S</creatorcontrib><creatorcontrib>Wilke, R</creatorcontrib><creatorcontrib>Büttgenbach, S</creatorcontrib><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>Electronics & Communications Abstracts</collection><collection>Mechanical & Transportation Engineering Abstracts</collection><collection>Solid State and Superconductivity Abstracts</collection><collection>Technology Research Database</collection><collection>Engineering Research Database</collection><collection>Advanced Technologies Database with Aerospace</collection><collection>MEDLINE - Academic</collection><jtitle>Lab on a chip</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Llobera, A</au><au>Demming, S</au><au>Wilke, R</au><au>Büttgenbach, S</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Multiple internal reflection poly(dimethylsiloxane) systems for optical sensing</atitle><jtitle>Lab on a chip</jtitle><addtitle>Lab Chip</addtitle><date>2007-01-01</date><risdate>2007</risdate><volume>7</volume><issue>11</issue><spage>1560</spage><epage>1566</epage><pages>1560-1566</pages><issn>1473-0197</issn><eissn>1473-0189</eissn><abstract>Compact poly(dimethylsiloxane)-based (PDMS) multiple internal reflection systems which comprise self-alignment systems, lenses, microfluidic channels and mirrors have been developed for highly sensitive absorbance measurements. With the proper definition of air mirrors at both sides of the sensing region, the optical path of the light from the LED has been meaningfully lengthened without a dramatic increase of the mean flow cell volume. By recursive positioning of such air mirrors, propagating multiple internal reflection (PMIR) systems have been designed, simulated and characterized. Experimental results confirm the ray-tracing predictions and allow the determining that there are some regions of the mean flow cell volume that do not contribute to the increase of the sensitivity. The tailoring of the sensing region, following the optical path, results in a similar limit of detection (110 nM) for fluorescein diluted in phosphate buffer. Finally, a ring configuration, labelled RMIR, has also been developed. With the addition of a third air mirror, the LOD can be decreased to 41 nM with the additional advantage of a substantial decrease of the length of the sensing region. These results confirm the validity of the proposed systems for high sensitivity measurements.</abstract><cop>England</cop><pmid>17960286</pmid><doi>10.1039/b704454b</doi><tpages>7</tpages></addata></record> |
fulltext | fulltext |
identifier | ISSN: 1473-0197 |
ispartof | Lab on a chip, 2007-01, Vol.7 (11), p.1560-1566 |
issn | 1473-0197 1473-0189 |
language | eng |
recordid | cdi_proquest_miscellaneous_68430809 |
source | Royal Society of Chemistry Journals Archive (1841-2007); MEDLINE; Royal Society Of Chemistry Journals 2008-; Alma/SFX Local Collection |
subjects | Dimethylpolysiloxanes - chemistry Optics and Photonics Sensitivity and Specificity Silicones - chemistry |
title | Multiple internal reflection poly(dimethylsiloxane) systems for optical sensing |
url | https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-27T15%3A57%3A27IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Multiple%20internal%20reflection%20poly(dimethylsiloxane)%20systems%20for%20optical%20sensing&rft.jtitle=Lab%20on%20a%20chip&rft.au=Llobera,%20A&rft.date=2007-01-01&rft.volume=7&rft.issue=11&rft.spage=1560&rft.epage=1566&rft.pages=1560-1566&rft.issn=1473-0197&rft.eissn=1473-0189&rft_id=info:doi/10.1039/b704454b&rft_dat=%3Cproquest_cross%3E34993407%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=34993407&rft_id=info:pmid/17960286&rfr_iscdi=true |