Dithiocarbamate functionalized or surface sorbed Merrifield resin beads as column materials for on line flow injection–flame atomic absorption spectrometry determination of lead

This article describes the preparation of dithiocarbamate immobilized/functionalized and diethylammonium dithiocarbamate (DDTC) sorbed Merrifield Chloromethylated Resin (MCR) beads and comparison of these materials for on-line flow injection (FI)–flame atomic absorption spectrometry (FAAS) determina...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Analytica chimica acta 2007-09, Vol.600 (1), p.205-213
Hauptverfasser: Praveen, R.S., Naidu, G.R.K., Prasada Rao, T.
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 213
container_issue 1
container_start_page 205
container_title Analytica chimica acta
container_volume 600
creator Praveen, R.S.
Naidu, G.R.K.
Prasada Rao, T.
description This article describes the preparation of dithiocarbamate immobilized/functionalized and diethylammonium dithiocarbamate (DDTC) sorbed Merrifield Chloromethylated Resin (MCR) beads and comparison of these materials for on-line flow injection (FI)–flame atomic absorption spectrometry (FAAS) determination of lead. The above two materials enrich lead quantitatively over an identical optimal pH range (8.0–9.0), a preconcentration/loading time (up to 4 min) and elution with acidified methanol (a minimum of 0.01 mol L −1 HNO 3 in methanol). However, the detection limit for lead using dithiocarbamate functionalized MCR beads is 1.3 μg L −1 compared to 3 μg L −1 for DDTC sorbed MCR beads. Again, the sensitivity enhancement over direct FAAS signal is 48- and 27-fold, respectively. In addition, dithiocarbamate functionalized MCR beads offers better precision compared to DDTC sorbed MCR beads as the corresponding relative standard deviation (R.S.D.) values for five successive determinations of 0.20 μg mL −1 are 1.44 and 4.36%, respectively. The accuracy of the developed on-line FI–FAAS procedure employing dithiocarbamate functionalized MCR beads as column material was tested by analyzing Certified Reference Material (CRM) of soil (IAEA soil-7) and marine sediment reference material (MESS-3) supplied by International Atomic Energy Agency (IAEA), Vienna and National Research Council (NRC), Canada, respectively. Furthermore, the developed procedure has been successfully tested for the analysis of surface, pond, ground and effluent water and soil samples collected from the vicinity of lead acid battery industry in India.
doi_str_mv 10.1016/j.aca.2007.01.012
format Article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_68336301</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><els_id>S0003267007000682</els_id><sourcerecordid>14843825</sourcerecordid><originalsourceid>FETCH-LOGICAL-c509t-6cde32d5747d04c5f86604d4eff213bf32987f7472d412c0a61e5e900a46d52e3</originalsourceid><addsrcrecordid>eNqFkcuKFDEUhgtRnHb0AdxINrqr9uRSqSpcyXiFETe6DqnkBNOkkjapGhlXvoOP4hv5JKanG2bnwIGQnO98Cfmb5imFLQUqX-622ugtA-i3QGuxe82GDj1vBWfifrMBAN4y2cNZ86iUXd0yCuJhc0b7EbgY5Kb588Yv33wyOk961gsSt0az-BR18D_RkpRJWbPTBklJeaonnzBn7zwGSzIWH8mE2haiCzEprHMkB032OhTi6nSKJPhYvSH9ID7u8Mb-99dvF_SMRC9p9oboqdr3hw4p-4rkNOOSr4nF6pp91Det5Eiolz1uHriqxyen9bz5-u7tl4sP7eXn9x8vXl-2poNxaaWxyJntetFbEKZzg5QgrEDnGOWT42wcele7zArKDGhJscMRQAtpO4b8vHlx9O5z-r5iWdTsi8EQdMS0FiUHziUHeidYGeCDEHeCVAyCD6yrID2CJqdSMjq1z37W-VpRUIfs1U7V7NUhewW0Fqszz07ydZrR3k6cwq7A8xOgi9HBZR2NL7fcSDsOsq_cqyOH9XOvPGZVjMdo0Ppcs1E2-f884x9aRdEE</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>14843825</pqid></control><display><type>article</type><title>Dithiocarbamate functionalized or surface sorbed Merrifield resin beads as column materials for on line flow injection–flame atomic absorption spectrometry determination of lead</title><source>Elsevier ScienceDirect Journals Complete</source><creator>Praveen, R.S. ; Naidu, G.R.K. ; Prasada Rao, T.</creator><creatorcontrib>Praveen, R.S. ; Naidu, G.R.K. ; Prasada Rao, T. ; Inorganic Materials Group</creatorcontrib><description>This article describes the preparation of dithiocarbamate immobilized/functionalized and diethylammonium dithiocarbamate (DDTC) sorbed Merrifield Chloromethylated Resin (MCR) beads and comparison of these materials for on-line flow injection (FI)–flame atomic absorption spectrometry (FAAS) determination of lead. The above two materials enrich lead quantitatively over an identical optimal pH range (8.0–9.0), a preconcentration/loading time (up to 4 min) and elution with acidified methanol (a minimum of 0.01 mol L −1 HNO 3 in methanol). However, the detection limit for lead using dithiocarbamate functionalized MCR beads is 1.3 μg L −1 compared to 3 μg L −1 for DDTC sorbed MCR beads. Again, the sensitivity enhancement over direct FAAS signal is 48- and 27-fold, respectively. In addition, dithiocarbamate functionalized MCR beads offers better precision compared to DDTC sorbed MCR beads as the corresponding relative standard deviation (R.S.D.) values for five successive determinations of 0.20 μg mL −1 are 1.44 and 4.36%, respectively. The accuracy of the developed on-line FI–FAAS procedure employing dithiocarbamate functionalized MCR beads as column material was tested by analyzing Certified Reference Material (CRM) of soil (IAEA soil-7) and marine sediment reference material (MESS-3) supplied by International Atomic Energy Agency (IAEA), Vienna and National Research Council (NRC), Canada, respectively. Furthermore, the developed procedure has been successfully tested for the analysis of surface, pond, ground and effluent water and soil samples collected from the vicinity of lead acid battery industry in India.</description><identifier>ISSN: 0003-2670</identifier><identifier>EISSN: 1873-4324</identifier><identifier>DOI: 10.1016/j.aca.2007.01.012</identifier><identifier>PMID: 17903486</identifier><identifier>CODEN: ACACAM</identifier><language>eng</language><publisher>Amsterdam: Elsevier B.V</publisher><subject>Analytical chemistry ; Chemical immobilization ; Chemistry ; Dithiocarbamate ; Exact sciences and technology ; Flow injection-flame atomic absorption spectrometry ; Lead ; Spectrometric and optical methods ; Surface sorption ; Waters and soils</subject><ispartof>Analytica chimica acta, 2007-09, Vol.600 (1), p.205-213</ispartof><rights>2007 Elsevier B.V.</rights><rights>2008 INIST-CNRS</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c509t-6cde32d5747d04c5f86604d4eff213bf32987f7472d412c0a61e5e900a46d52e3</citedby><cites>FETCH-LOGICAL-c509t-6cde32d5747d04c5f86604d4eff213bf32987f7472d412c0a61e5e900a46d52e3</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://www.sciencedirect.com/science/article/pii/S0003267007000682$$EHTML$$P50$$Gelsevier$$H</linktohtml><link.rule.ids>309,310,314,776,780,785,786,3537,23911,23912,25120,27903,27904,65309</link.rule.ids><backlink>$$Uhttp://pascal-francis.inist.fr/vibad/index.php?action=getRecordDetail&amp;idt=19153067$$DView record in Pascal Francis$$Hfree_for_read</backlink><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/17903486$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Praveen, R.S.</creatorcontrib><creatorcontrib>Naidu, G.R.K.</creatorcontrib><creatorcontrib>Prasada Rao, T.</creatorcontrib><creatorcontrib>Inorganic Materials Group</creatorcontrib><title>Dithiocarbamate functionalized or surface sorbed Merrifield resin beads as column materials for on line flow injection–flame atomic absorption spectrometry determination of lead</title><title>Analytica chimica acta</title><addtitle>Anal Chim Acta</addtitle><description>This article describes the preparation of dithiocarbamate immobilized/functionalized and diethylammonium dithiocarbamate (DDTC) sorbed Merrifield Chloromethylated Resin (MCR) beads and comparison of these materials for on-line flow injection (FI)–flame atomic absorption spectrometry (FAAS) determination of lead. The above two materials enrich lead quantitatively over an identical optimal pH range (8.0–9.0), a preconcentration/loading time (up to 4 min) and elution with acidified methanol (a minimum of 0.01 mol L −1 HNO 3 in methanol). However, the detection limit for lead using dithiocarbamate functionalized MCR beads is 1.3 μg L −1 compared to 3 μg L −1 for DDTC sorbed MCR beads. Again, the sensitivity enhancement over direct FAAS signal is 48- and 27-fold, respectively. In addition, dithiocarbamate functionalized MCR beads offers better precision compared to DDTC sorbed MCR beads as the corresponding relative standard deviation (R.S.D.) values for five successive determinations of 0.20 μg mL −1 are 1.44 and 4.36%, respectively. The accuracy of the developed on-line FI–FAAS procedure employing dithiocarbamate functionalized MCR beads as column material was tested by analyzing Certified Reference Material (CRM) of soil (IAEA soil-7) and marine sediment reference material (MESS-3) supplied by International Atomic Energy Agency (IAEA), Vienna and National Research Council (NRC), Canada, respectively. Furthermore, the developed procedure has been successfully tested for the analysis of surface, pond, ground and effluent water and soil samples collected from the vicinity of lead acid battery industry in India.</description><subject>Analytical chemistry</subject><subject>Chemical immobilization</subject><subject>Chemistry</subject><subject>Dithiocarbamate</subject><subject>Exact sciences and technology</subject><subject>Flow injection-flame atomic absorption spectrometry</subject><subject>Lead</subject><subject>Spectrometric and optical methods</subject><subject>Surface sorption</subject><subject>Waters and soils</subject><issn>0003-2670</issn><issn>1873-4324</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2007</creationdate><recordtype>article</recordtype><recordid>eNqFkcuKFDEUhgtRnHb0AdxINrqr9uRSqSpcyXiFETe6DqnkBNOkkjapGhlXvoOP4hv5JKanG2bnwIGQnO98Cfmb5imFLQUqX-622ugtA-i3QGuxe82GDj1vBWfifrMBAN4y2cNZ86iUXd0yCuJhc0b7EbgY5Kb588Yv33wyOk961gsSt0az-BR18D_RkpRJWbPTBklJeaonnzBn7zwGSzIWH8mE2haiCzEprHMkB032OhTi6nSKJPhYvSH9ID7u8Mb-99dvF_SMRC9p9oboqdr3hw4p-4rkNOOSr4nF6pp91Det5Eiolz1uHriqxyen9bz5-u7tl4sP7eXn9x8vXl-2poNxaaWxyJntetFbEKZzg5QgrEDnGOWT42wcele7zArKDGhJscMRQAtpO4b8vHlx9O5z-r5iWdTsi8EQdMS0FiUHziUHeidYGeCDEHeCVAyCD6yrID2CJqdSMjq1z37W-VpRUIfs1U7V7NUhewW0Fqszz07ydZrR3k6cwq7A8xOgi9HBZR2NL7fcSDsOsq_cqyOH9XOvPGZVjMdo0Ppcs1E2-f884x9aRdEE</recordid><startdate>20070926</startdate><enddate>20070926</enddate><creator>Praveen, R.S.</creator><creator>Naidu, G.R.K.</creator><creator>Prasada Rao, T.</creator><general>Elsevier B.V</general><general>Elsevier</general><scope>IQODW</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7ST</scope><scope>C1K</scope><scope>SOI</scope><scope>7U5</scope><scope>8FD</scope><scope>L7M</scope><scope>7X8</scope></search><sort><creationdate>20070926</creationdate><title>Dithiocarbamate functionalized or surface sorbed Merrifield resin beads as column materials for on line flow injection–flame atomic absorption spectrometry determination of lead</title><author>Praveen, R.S. ; Naidu, G.R.K. ; Prasada Rao, T.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c509t-6cde32d5747d04c5f86604d4eff213bf32987f7472d412c0a61e5e900a46d52e3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2007</creationdate><topic>Analytical chemistry</topic><topic>Chemical immobilization</topic><topic>Chemistry</topic><topic>Dithiocarbamate</topic><topic>Exact sciences and technology</topic><topic>Flow injection-flame atomic absorption spectrometry</topic><topic>Lead</topic><topic>Spectrometric and optical methods</topic><topic>Surface sorption</topic><topic>Waters and soils</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Praveen, R.S.</creatorcontrib><creatorcontrib>Naidu, G.R.K.</creatorcontrib><creatorcontrib>Prasada Rao, T.</creatorcontrib><creatorcontrib>Inorganic Materials Group</creatorcontrib><collection>Pascal-Francis</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>Environment Abstracts</collection><collection>Environmental Sciences and Pollution Management</collection><collection>Environment Abstracts</collection><collection>Solid State and Superconductivity Abstracts</collection><collection>Technology Research Database</collection><collection>Advanced Technologies Database with Aerospace</collection><collection>MEDLINE - Academic</collection><jtitle>Analytica chimica acta</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Praveen, R.S.</au><au>Naidu, G.R.K.</au><au>Prasada Rao, T.</au><aucorp>Inorganic Materials Group</aucorp><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Dithiocarbamate functionalized or surface sorbed Merrifield resin beads as column materials for on line flow injection–flame atomic absorption spectrometry determination of lead</atitle><jtitle>Analytica chimica acta</jtitle><addtitle>Anal Chim Acta</addtitle><date>2007-09-26</date><risdate>2007</risdate><volume>600</volume><issue>1</issue><spage>205</spage><epage>213</epage><pages>205-213</pages><issn>0003-2670</issn><eissn>1873-4324</eissn><coden>ACACAM</coden><abstract>This article describes the preparation of dithiocarbamate immobilized/functionalized and diethylammonium dithiocarbamate (DDTC) sorbed Merrifield Chloromethylated Resin (MCR) beads and comparison of these materials for on-line flow injection (FI)–flame atomic absorption spectrometry (FAAS) determination of lead. The above two materials enrich lead quantitatively over an identical optimal pH range (8.0–9.0), a preconcentration/loading time (up to 4 min) and elution with acidified methanol (a minimum of 0.01 mol L −1 HNO 3 in methanol). However, the detection limit for lead using dithiocarbamate functionalized MCR beads is 1.3 μg L −1 compared to 3 μg L −1 for DDTC sorbed MCR beads. Again, the sensitivity enhancement over direct FAAS signal is 48- and 27-fold, respectively. In addition, dithiocarbamate functionalized MCR beads offers better precision compared to DDTC sorbed MCR beads as the corresponding relative standard deviation (R.S.D.) values for five successive determinations of 0.20 μg mL −1 are 1.44 and 4.36%, respectively. The accuracy of the developed on-line FI–FAAS procedure employing dithiocarbamate functionalized MCR beads as column material was tested by analyzing Certified Reference Material (CRM) of soil (IAEA soil-7) and marine sediment reference material (MESS-3) supplied by International Atomic Energy Agency (IAEA), Vienna and National Research Council (NRC), Canada, respectively. Furthermore, the developed procedure has been successfully tested for the analysis of surface, pond, ground and effluent water and soil samples collected from the vicinity of lead acid battery industry in India.</abstract><cop>Amsterdam</cop><pub>Elsevier B.V</pub><pmid>17903486</pmid><doi>10.1016/j.aca.2007.01.012</doi><tpages>9</tpages></addata></record>
fulltext fulltext
identifier ISSN: 0003-2670
ispartof Analytica chimica acta, 2007-09, Vol.600 (1), p.205-213
issn 0003-2670
1873-4324
language eng
recordid cdi_proquest_miscellaneous_68336301
source Elsevier ScienceDirect Journals Complete
subjects Analytical chemistry
Chemical immobilization
Chemistry
Dithiocarbamate
Exact sciences and technology
Flow injection-flame atomic absorption spectrometry
Lead
Spectrometric and optical methods
Surface sorption
Waters and soils
title Dithiocarbamate functionalized or surface sorbed Merrifield resin beads as column materials for on line flow injection–flame atomic absorption spectrometry determination of lead
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-27T20%3A25%3A29IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Dithiocarbamate%20functionalized%20or%20surface%20sorbed%20Merrifield%20resin%20beads%20as%20column%20materials%20for%20on%20line%20flow%20injection%E2%80%93flame%20atomic%20absorption%20spectrometry%20determination%20of%20lead&rft.jtitle=Analytica%20chimica%20acta&rft.au=Praveen,%20R.S.&rft.aucorp=Inorganic%20Materials%20Group&rft.date=2007-09-26&rft.volume=600&rft.issue=1&rft.spage=205&rft.epage=213&rft.pages=205-213&rft.issn=0003-2670&rft.eissn=1873-4324&rft.coden=ACACAM&rft_id=info:doi/10.1016/j.aca.2007.01.012&rft_dat=%3Cproquest_cross%3E14843825%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=14843825&rft_id=info:pmid/17903486&rft_els_id=S0003267007000682&rfr_iscdi=true