Miniaturization of environmental chemical assays in flowing systems: The lab-on-a-valve approach vis-à-vis lab-on-a-chip microfluidic devices

The analytical capabilities of the microminiaturized lab-on-a-valve (LOV) module integrated into a microsequential injection (μSI) fluidic system in terms of analytical chemical performance, microfluidic handling and on-line sample processing are compared to those of the micro total analysis systems...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Analytica chimica acta 2007-09, Vol.600 (1), p.46-57
Hauptverfasser: Miró, Manuel, Hansen, Elo Harald
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 57
container_issue 1
container_start_page 46
container_title Analytica chimica acta
container_volume 600
creator Miró, Manuel
Hansen, Elo Harald
description The analytical capabilities of the microminiaturized lab-on-a-valve (LOV) module integrated into a microsequential injection (μSI) fluidic system in terms of analytical chemical performance, microfluidic handling and on-line sample processing are compared to those of the micro total analysis systems (μTAS), also termed lab-on-a-chip (LOC). This paper illustrates, via selected representative examples, the potentials of the LOV scheme vis-à-vis LOC microdevices for environmental assays. By means of user-friendly programmable flow and the exploitation of the interplay between the thermodynamics and the kinetics of the chemical reactions at will, LOV allows accommodation of reactions which, at least at the present stage, are not feasible by application of microfluidic LOC systems. Thus, in LOV one may take full advantage of kinetic discriminations schemes, where even subtle differences in reactions are utilized for analytical purposes. Furthermore, it is also feasible to handle multi-step sequential reactions of divergent kinetics; to conduct multi-parametric determinations without manifold reconfiguration by utilization of the inherent open-architecture of the micromachined unit for implementation of peripheral modules and automated handling of a variety of reagents; and most importantly, it offers itself as a versatile front end to a plethora of detection schemes. Not the least, LOV is regarded as an emerging downscaled tool to overcome the dilemma of LOC microsystems to admit real-life samples. This is nurtured via its intrinsic flexibility for accommodation of sample pre-treatment schemes aimed at the on-line manipulation of complex samples. Thus, LOV is playing a prominent role in the environmental field, whenever the monitoring of trace level concentration of pollutants is pursued, because both matrix isolation and preconcentration of target analytes is most often imperative, or in fact necessary, prior to sample presentation to the detector.
doi_str_mv 10.1016/j.aca.2007.02.035
format Article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_68335985</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><els_id>S0003267007003327</els_id><sourcerecordid>30112681</sourcerecordid><originalsourceid>FETCH-LOGICAL-c455t-bea0f8964eba5599f06f6992237a9c0e87aaf2e88d5e26ff442598397cc86bc13</originalsourceid><addsrcrecordid>eNqFkUuO1DAQhi0EYpqBA7BB3sDOwY88YTUa8ZIGsRnWVsUp09VKnCZOgppDcAbuwsVwq1vqHazKlr7_V9kfY8-VzJRU5etdBg4yLWWVSZ1JUzxgG1VXRuRG5w_ZRkpphC4recWexLhLV61k_phdqaqRJi_Nhv36TIFgXib6CTONgY-eY1hpGsOAYYaeuy0O5NIBYoRD5BS478cfFL7xeIgzDvENv98i76EVYxAgVuhX5LDfTyO4LV8pij-_RRoXxG1pz1PrNPp-oY4c73Alh_Epe-Shj_jsPK_Z1_fv7m8_irsvHz7d3twJlxfFLFoE6eumzLGFomgaL0tfNo3WpoLGSawrAK-xrrsCdel9nuuiqU1TOVeXrVPmmr069aYlvy8YZztQdNj3EHBcoi1rY1Ki-C9opFK6rI-N6gSmR8U4obf7iQaYDlZJe7RldzbZskdbVmqbbKXMi3P50g7YXRJnPQl4eQYgJgV-guAoXrhGFUbmeeLenjhMf7YSTjY6wuCwowndbLuR_rHGXzevtKw</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>30112681</pqid></control><display><type>article</type><title>Miniaturization of environmental chemical assays in flowing systems: The lab-on-a-valve approach vis-à-vis lab-on-a-chip microfluidic devices</title><source>Elsevier ScienceDirect Journals</source><creator>Miró, Manuel ; Hansen, Elo Harald</creator><creatorcontrib>Miró, Manuel ; Hansen, Elo Harald</creatorcontrib><description>The analytical capabilities of the microminiaturized lab-on-a-valve (LOV) module integrated into a microsequential injection (μSI) fluidic system in terms of analytical chemical performance, microfluidic handling and on-line sample processing are compared to those of the micro total analysis systems (μTAS), also termed lab-on-a-chip (LOC). This paper illustrates, via selected representative examples, the potentials of the LOV scheme vis-à-vis LOC microdevices for environmental assays. By means of user-friendly programmable flow and the exploitation of the interplay between the thermodynamics and the kinetics of the chemical reactions at will, LOV allows accommodation of reactions which, at least at the present stage, are not feasible by application of microfluidic LOC systems. Thus, in LOV one may take full advantage of kinetic discriminations schemes, where even subtle differences in reactions are utilized for analytical purposes. Furthermore, it is also feasible to handle multi-step sequential reactions of divergent kinetics; to conduct multi-parametric determinations without manifold reconfiguration by utilization of the inherent open-architecture of the micromachined unit for implementation of peripheral modules and automated handling of a variety of reagents; and most importantly, it offers itself as a versatile front end to a plethora of detection schemes. Not the least, LOV is regarded as an emerging downscaled tool to overcome the dilemma of LOC microsystems to admit real-life samples. This is nurtured via its intrinsic flexibility for accommodation of sample pre-treatment schemes aimed at the on-line manipulation of complex samples. Thus, LOV is playing a prominent role in the environmental field, whenever the monitoring of trace level concentration of pollutants is pursued, because both matrix isolation and preconcentration of target analytes is most often imperative, or in fact necessary, prior to sample presentation to the detector.</description><identifier>ISSN: 0003-2670</identifier><identifier>EISSN: 1873-4324</identifier><identifier>DOI: 10.1016/j.aca.2007.02.035</identifier><identifier>PMID: 17903463</identifier><identifier>CODEN: ACACAM</identifier><language>eng</language><publisher>Amsterdam: Elsevier B.V</publisher><subject>Analytical chemistry ; Applied sciences ; Chemistry ; Environmental assays ; Exact sciences and technology ; General, instrumentation ; Global environmental pollution ; Lab-on-a-chip ; Lab-on-a-valve ; Microfluidics ; Pollution</subject><ispartof>Analytica chimica acta, 2007-09, Vol.600 (1), p.46-57</ispartof><rights>2007 Elsevier B.V.</rights><rights>2008 INIST-CNRS</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c455t-bea0f8964eba5599f06f6992237a9c0e87aaf2e88d5e26ff442598397cc86bc13</citedby><cites>FETCH-LOGICAL-c455t-bea0f8964eba5599f06f6992237a9c0e87aaf2e88d5e26ff442598397cc86bc13</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://www.sciencedirect.com/science/article/pii/S0003267007003327$$EHTML$$P50$$Gelsevier$$H</linktohtml><link.rule.ids>309,310,314,776,780,785,786,3537,23909,23910,25118,27901,27902,65306</link.rule.ids><backlink>$$Uhttp://pascal-francis.inist.fr/vibad/index.php?action=getRecordDetail&amp;idt=19153044$$DView record in Pascal Francis$$Hfree_for_read</backlink><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/17903463$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Miró, Manuel</creatorcontrib><creatorcontrib>Hansen, Elo Harald</creatorcontrib><title>Miniaturization of environmental chemical assays in flowing systems: The lab-on-a-valve approach vis-à-vis lab-on-a-chip microfluidic devices</title><title>Analytica chimica acta</title><addtitle>Anal Chim Acta</addtitle><description>The analytical capabilities of the microminiaturized lab-on-a-valve (LOV) module integrated into a microsequential injection (μSI) fluidic system in terms of analytical chemical performance, microfluidic handling and on-line sample processing are compared to those of the micro total analysis systems (μTAS), also termed lab-on-a-chip (LOC). This paper illustrates, via selected representative examples, the potentials of the LOV scheme vis-à-vis LOC microdevices for environmental assays. By means of user-friendly programmable flow and the exploitation of the interplay between the thermodynamics and the kinetics of the chemical reactions at will, LOV allows accommodation of reactions which, at least at the present stage, are not feasible by application of microfluidic LOC systems. Thus, in LOV one may take full advantage of kinetic discriminations schemes, where even subtle differences in reactions are utilized for analytical purposes. Furthermore, it is also feasible to handle multi-step sequential reactions of divergent kinetics; to conduct multi-parametric determinations without manifold reconfiguration by utilization of the inherent open-architecture of the micromachined unit for implementation of peripheral modules and automated handling of a variety of reagents; and most importantly, it offers itself as a versatile front end to a plethora of detection schemes. Not the least, LOV is regarded as an emerging downscaled tool to overcome the dilemma of LOC microsystems to admit real-life samples. This is nurtured via its intrinsic flexibility for accommodation of sample pre-treatment schemes aimed at the on-line manipulation of complex samples. Thus, LOV is playing a prominent role in the environmental field, whenever the monitoring of trace level concentration of pollutants is pursued, because both matrix isolation and preconcentration of target analytes is most often imperative, or in fact necessary, prior to sample presentation to the detector.</description><subject>Analytical chemistry</subject><subject>Applied sciences</subject><subject>Chemistry</subject><subject>Environmental assays</subject><subject>Exact sciences and technology</subject><subject>General, instrumentation</subject><subject>Global environmental pollution</subject><subject>Lab-on-a-chip</subject><subject>Lab-on-a-valve</subject><subject>Microfluidics</subject><subject>Pollution</subject><issn>0003-2670</issn><issn>1873-4324</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2007</creationdate><recordtype>article</recordtype><recordid>eNqFkUuO1DAQhi0EYpqBA7BB3sDOwY88YTUa8ZIGsRnWVsUp09VKnCZOgppDcAbuwsVwq1vqHazKlr7_V9kfY8-VzJRU5etdBg4yLWWVSZ1JUzxgG1VXRuRG5w_ZRkpphC4recWexLhLV61k_phdqaqRJi_Nhv36TIFgXib6CTONgY-eY1hpGsOAYYaeuy0O5NIBYoRD5BS478cfFL7xeIgzDvENv98i76EVYxAgVuhX5LDfTyO4LV8pij-_RRoXxG1pz1PrNPp-oY4c73Alh_Epe-Shj_jsPK_Z1_fv7m8_irsvHz7d3twJlxfFLFoE6eumzLGFomgaL0tfNo3WpoLGSawrAK-xrrsCdel9nuuiqU1TOVeXrVPmmr069aYlvy8YZztQdNj3EHBcoi1rY1Ki-C9opFK6rI-N6gSmR8U4obf7iQaYDlZJe7RldzbZskdbVmqbbKXMi3P50g7YXRJnPQl4eQYgJgV-guAoXrhGFUbmeeLenjhMf7YSTjY6wuCwowndbLuR_rHGXzevtKw</recordid><startdate>20070926</startdate><enddate>20070926</enddate><creator>Miró, Manuel</creator><creator>Hansen, Elo Harald</creator><general>Elsevier B.V</general><general>Elsevier</general><scope>IQODW</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7U5</scope><scope>8FD</scope><scope>L7M</scope><scope>7X8</scope></search><sort><creationdate>20070926</creationdate><title>Miniaturization of environmental chemical assays in flowing systems: The lab-on-a-valve approach vis-à-vis lab-on-a-chip microfluidic devices</title><author>Miró, Manuel ; Hansen, Elo Harald</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c455t-bea0f8964eba5599f06f6992237a9c0e87aaf2e88d5e26ff442598397cc86bc13</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2007</creationdate><topic>Analytical chemistry</topic><topic>Applied sciences</topic><topic>Chemistry</topic><topic>Environmental assays</topic><topic>Exact sciences and technology</topic><topic>General, instrumentation</topic><topic>Global environmental pollution</topic><topic>Lab-on-a-chip</topic><topic>Lab-on-a-valve</topic><topic>Microfluidics</topic><topic>Pollution</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Miró, Manuel</creatorcontrib><creatorcontrib>Hansen, Elo Harald</creatorcontrib><collection>Pascal-Francis</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>Solid State and Superconductivity Abstracts</collection><collection>Technology Research Database</collection><collection>Advanced Technologies Database with Aerospace</collection><collection>MEDLINE - Academic</collection><jtitle>Analytica chimica acta</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Miró, Manuel</au><au>Hansen, Elo Harald</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Miniaturization of environmental chemical assays in flowing systems: The lab-on-a-valve approach vis-à-vis lab-on-a-chip microfluidic devices</atitle><jtitle>Analytica chimica acta</jtitle><addtitle>Anal Chim Acta</addtitle><date>2007-09-26</date><risdate>2007</risdate><volume>600</volume><issue>1</issue><spage>46</spage><epage>57</epage><pages>46-57</pages><issn>0003-2670</issn><eissn>1873-4324</eissn><coden>ACACAM</coden><abstract>The analytical capabilities of the microminiaturized lab-on-a-valve (LOV) module integrated into a microsequential injection (μSI) fluidic system in terms of analytical chemical performance, microfluidic handling and on-line sample processing are compared to those of the micro total analysis systems (μTAS), also termed lab-on-a-chip (LOC). This paper illustrates, via selected representative examples, the potentials of the LOV scheme vis-à-vis LOC microdevices for environmental assays. By means of user-friendly programmable flow and the exploitation of the interplay between the thermodynamics and the kinetics of the chemical reactions at will, LOV allows accommodation of reactions which, at least at the present stage, are not feasible by application of microfluidic LOC systems. Thus, in LOV one may take full advantage of kinetic discriminations schemes, where even subtle differences in reactions are utilized for analytical purposes. Furthermore, it is also feasible to handle multi-step sequential reactions of divergent kinetics; to conduct multi-parametric determinations without manifold reconfiguration by utilization of the inherent open-architecture of the micromachined unit for implementation of peripheral modules and automated handling of a variety of reagents; and most importantly, it offers itself as a versatile front end to a plethora of detection schemes. Not the least, LOV is regarded as an emerging downscaled tool to overcome the dilemma of LOC microsystems to admit real-life samples. This is nurtured via its intrinsic flexibility for accommodation of sample pre-treatment schemes aimed at the on-line manipulation of complex samples. Thus, LOV is playing a prominent role in the environmental field, whenever the monitoring of trace level concentration of pollutants is pursued, because both matrix isolation and preconcentration of target analytes is most often imperative, or in fact necessary, prior to sample presentation to the detector.</abstract><cop>Amsterdam</cop><pub>Elsevier B.V</pub><pmid>17903463</pmid><doi>10.1016/j.aca.2007.02.035</doi><tpages>12</tpages><oa>free_for_read</oa></addata></record>
fulltext fulltext
identifier ISSN: 0003-2670
ispartof Analytica chimica acta, 2007-09, Vol.600 (1), p.46-57
issn 0003-2670
1873-4324
language eng
recordid cdi_proquest_miscellaneous_68335985
source Elsevier ScienceDirect Journals
subjects Analytical chemistry
Applied sciences
Chemistry
Environmental assays
Exact sciences and technology
General, instrumentation
Global environmental pollution
Lab-on-a-chip
Lab-on-a-valve
Microfluidics
Pollution
title Miniaturization of environmental chemical assays in flowing systems: The lab-on-a-valve approach vis-à-vis lab-on-a-chip microfluidic devices
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-02-04T11%3A47%3A25IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Miniaturization%20of%20environmental%20chemical%20assays%20in%20flowing%20systems:%20The%20lab-on-a-valve%20approach%20vis-%C3%A0-vis%20lab-on-a-chip%20microfluidic%20devices&rft.jtitle=Analytica%20chimica%20acta&rft.au=Mir%C3%B3,%20Manuel&rft.date=2007-09-26&rft.volume=600&rft.issue=1&rft.spage=46&rft.epage=57&rft.pages=46-57&rft.issn=0003-2670&rft.eissn=1873-4324&rft.coden=ACACAM&rft_id=info:doi/10.1016/j.aca.2007.02.035&rft_dat=%3Cproquest_cross%3E30112681%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=30112681&rft_id=info:pmid/17903463&rft_els_id=S0003267007003327&rfr_iscdi=true