Simple and sensitive determination of menatetrenone and its epoxide metabolite in human plasma

A simple and rapid quantification method was developed for determining menatetrenone and its epoxide metabolite in human plasma. After a simple protein precipitation with methanol, the analytes were chromatographed on a reversed-phase C 18 column and detected by LC/MS/MS with atmospheric pressure ch...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Journal of pharmaceutical and biomedical analysis 2007-09, Vol.44 (5), p.1178-1182
Hauptverfasser: Kang, Wonku, Jeong, Ji-Hoon, Ma, Eunsook, Kwon, Kwang-il
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 1182
container_issue 5
container_start_page 1178
container_title Journal of pharmaceutical and biomedical analysis
container_volume 44
creator Kang, Wonku
Jeong, Ji-Hoon
Ma, Eunsook
Kwon, Kwang-il
description A simple and rapid quantification method was developed for determining menatetrenone and its epoxide metabolite in human plasma. After a simple protein precipitation with methanol, the analytes were chromatographed on a reversed-phase C 18 column and detected by LC/MS/MS with atmospheric pressure chemical ionization. The coefficient of variation of the assay precision was less than 10.1%, and the accuracy ranged from 98.0 to 106.5%. The limit of detection of menatetrenone and its epoxide was 0.5 and 0.2 ng/ml, respectively. This method was used to simultaneously measure the plasma concentration of menatetrenone and its epoxide metabolite from healthy subjects after a single 30 mg oral dose of menatetrenone.
doi_str_mv 10.1016/j.jpba.2007.04.028
format Article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_68178753</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><els_id>S0731708507002439</els_id><sourcerecordid>68178753</sourcerecordid><originalsourceid>FETCH-LOGICAL-c384t-626ca1c7569ad7c94b51972ccf8759cebb280b0ed52f060313bc69dbaee375643</originalsourceid><addsrcrecordid>eNp9kM1q3DAYRUVpaKZpXyCLoE2zs6MfW7IhmxCSthDoog10VaGfz0SDLTmSJqRvXw0zkF1X-kDnXi4HoXNKWkqouNq229XolhEiW9K1hA3v0IYOkjdMdL_fow2RnDaSDP0p-pjzlhDS07H7gE6p7AXlgm3Qn59-WWfAOjicIWRf_AtgBwXS4oMuPgYcJ7xAvaEkCDEcYF8yhjW-egf1t2gTZ18A-4CfdosOeJ11XvQndDLpOcPn43uGHu_vft1-ax5-fP1-e_PQWD50pRFMWE1tXTVqJ-3YmTpUMmunQfajBWPYQAwB17OJCMIpN1aMzmgAXkMdP0OXh941xecd5KIWny3Msw4Qd1mJgcpaxSvIDqBNMecEk1qTX3T6qyhRe6tqq_ZW1d6qIp2qVmvo4ti-Mwu4t8hRYwW-HAGdrZ6npIP1-Y0bq_mO72deHzioLl48JJWth2DB-QS2KBf9_3b8A_FYlwc</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>68178753</pqid></control><display><type>article</type><title>Simple and sensitive determination of menatetrenone and its epoxide metabolite in human plasma</title><source>MEDLINE</source><source>Elsevier ScienceDirect Journals Complete</source><creator>Kang, Wonku ; Jeong, Ji-Hoon ; Ma, Eunsook ; Kwon, Kwang-il</creator><creatorcontrib>Kang, Wonku ; Jeong, Ji-Hoon ; Ma, Eunsook ; Kwon, Kwang-il</creatorcontrib><description>A simple and rapid quantification method was developed for determining menatetrenone and its epoxide metabolite in human plasma. After a simple protein precipitation with methanol, the analytes were chromatographed on a reversed-phase C 18 column and detected by LC/MS/MS with atmospheric pressure chemical ionization. The coefficient of variation of the assay precision was less than 10.1%, and the accuracy ranged from 98.0 to 106.5%. The limit of detection of menatetrenone and its epoxide was 0.5 and 0.2 ng/ml, respectively. This method was used to simultaneously measure the plasma concentration of menatetrenone and its epoxide metabolite from healthy subjects after a single 30 mg oral dose of menatetrenone.</description><identifier>ISSN: 0731-7085</identifier><identifier>EISSN: 1873-264X</identifier><identifier>DOI: 10.1016/j.jpba.2007.04.028</identifier><identifier>PMID: 17561362</identifier><identifier>CODEN: JPBADA</identifier><language>eng</language><publisher>Amsterdam: Elsevier B.V</publisher><subject>Analysis ; Analytical, structural and metabolic biochemistry ; Biological and medical sciences ; Chromatography, Liquid - methods ; Epoxide metabolite ; Epoxy Compounds - blood ; Fundamental and applied biological sciences. Psychology ; General pharmacology ; Hemostatics - blood ; Hemostatics - metabolism ; Humans ; LC/MS/MS ; Medical sciences ; Menatetrenone ; Methanol - chemistry ; Pharmacology. Drug treatments ; Reference Standards ; Reproducibility of Results ; Sensitivity and Specificity ; Solvents - chemistry ; Tandem Mass Spectrometry - methods ; Time Factors ; Vitamin K 2 - analogs &amp; derivatives ; Vitamin K 2 - blood ; Vitamin K 2 - metabolism</subject><ispartof>Journal of pharmaceutical and biomedical analysis, 2007-09, Vol.44 (5), p.1178-1182</ispartof><rights>2007</rights><rights>2007 INIST-CNRS</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c384t-626ca1c7569ad7c94b51972ccf8759cebb280b0ed52f060313bc69dbaee375643</citedby><cites>FETCH-LOGICAL-c384t-626ca1c7569ad7c94b51972ccf8759cebb280b0ed52f060313bc69dbaee375643</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://dx.doi.org/10.1016/j.jpba.2007.04.028$$EHTML$$P50$$Gelsevier$$H</linktohtml><link.rule.ids>314,780,784,3550,27924,27925,45995</link.rule.ids><backlink>$$Uhttp://pascal-francis.inist.fr/vibad/index.php?action=getRecordDetail&amp;idt=19005434$$DView record in Pascal Francis$$Hfree_for_read</backlink><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/17561362$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Kang, Wonku</creatorcontrib><creatorcontrib>Jeong, Ji-Hoon</creatorcontrib><creatorcontrib>Ma, Eunsook</creatorcontrib><creatorcontrib>Kwon, Kwang-il</creatorcontrib><title>Simple and sensitive determination of menatetrenone and its epoxide metabolite in human plasma</title><title>Journal of pharmaceutical and biomedical analysis</title><addtitle>J Pharm Biomed Anal</addtitle><description>A simple and rapid quantification method was developed for determining menatetrenone and its epoxide metabolite in human plasma. After a simple protein precipitation with methanol, the analytes were chromatographed on a reversed-phase C 18 column and detected by LC/MS/MS with atmospheric pressure chemical ionization. The coefficient of variation of the assay precision was less than 10.1%, and the accuracy ranged from 98.0 to 106.5%. The limit of detection of menatetrenone and its epoxide was 0.5 and 0.2 ng/ml, respectively. This method was used to simultaneously measure the plasma concentration of menatetrenone and its epoxide metabolite from healthy subjects after a single 30 mg oral dose of menatetrenone.</description><subject>Analysis</subject><subject>Analytical, structural and metabolic biochemistry</subject><subject>Biological and medical sciences</subject><subject>Chromatography, Liquid - methods</subject><subject>Epoxide metabolite</subject><subject>Epoxy Compounds - blood</subject><subject>Fundamental and applied biological sciences. Psychology</subject><subject>General pharmacology</subject><subject>Hemostatics - blood</subject><subject>Hemostatics - metabolism</subject><subject>Humans</subject><subject>LC/MS/MS</subject><subject>Medical sciences</subject><subject>Menatetrenone</subject><subject>Methanol - chemistry</subject><subject>Pharmacology. Drug treatments</subject><subject>Reference Standards</subject><subject>Reproducibility of Results</subject><subject>Sensitivity and Specificity</subject><subject>Solvents - chemistry</subject><subject>Tandem Mass Spectrometry - methods</subject><subject>Time Factors</subject><subject>Vitamin K 2 - analogs &amp; derivatives</subject><subject>Vitamin K 2 - blood</subject><subject>Vitamin K 2 - metabolism</subject><issn>0731-7085</issn><issn>1873-264X</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2007</creationdate><recordtype>article</recordtype><sourceid>EIF</sourceid><recordid>eNp9kM1q3DAYRUVpaKZpXyCLoE2zs6MfW7IhmxCSthDoog10VaGfz0SDLTmSJqRvXw0zkF1X-kDnXi4HoXNKWkqouNq229XolhEiW9K1hA3v0IYOkjdMdL_fow2RnDaSDP0p-pjzlhDS07H7gE6p7AXlgm3Qn59-WWfAOjicIWRf_AtgBwXS4oMuPgYcJ7xAvaEkCDEcYF8yhjW-egf1t2gTZ18A-4CfdosOeJ11XvQndDLpOcPn43uGHu_vft1-ax5-fP1-e_PQWD50pRFMWE1tXTVqJ-3YmTpUMmunQfajBWPYQAwB17OJCMIpN1aMzmgAXkMdP0OXh941xecd5KIWny3Msw4Qd1mJgcpaxSvIDqBNMecEk1qTX3T6qyhRe6tqq_ZW1d6qIp2qVmvo4ti-Mwu4t8hRYwW-HAGdrZ6npIP1-Y0bq_mO72deHzioLl48JJWth2DB-QS2KBf9_3b8A_FYlwc</recordid><startdate>20070903</startdate><enddate>20070903</enddate><creator>Kang, Wonku</creator><creator>Jeong, Ji-Hoon</creator><creator>Ma, Eunsook</creator><creator>Kwon, Kwang-il</creator><general>Elsevier B.V</general><general>Elsevier Science</general><scope>IQODW</scope><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope></search><sort><creationdate>20070903</creationdate><title>Simple and sensitive determination of menatetrenone and its epoxide metabolite in human plasma</title><author>Kang, Wonku ; Jeong, Ji-Hoon ; Ma, Eunsook ; Kwon, Kwang-il</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c384t-626ca1c7569ad7c94b51972ccf8759cebb280b0ed52f060313bc69dbaee375643</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2007</creationdate><topic>Analysis</topic><topic>Analytical, structural and metabolic biochemistry</topic><topic>Biological and medical sciences</topic><topic>Chromatography, Liquid - methods</topic><topic>Epoxide metabolite</topic><topic>Epoxy Compounds - blood</topic><topic>Fundamental and applied biological sciences. Psychology</topic><topic>General pharmacology</topic><topic>Hemostatics - blood</topic><topic>Hemostatics - metabolism</topic><topic>Humans</topic><topic>LC/MS/MS</topic><topic>Medical sciences</topic><topic>Menatetrenone</topic><topic>Methanol - chemistry</topic><topic>Pharmacology. Drug treatments</topic><topic>Reference Standards</topic><topic>Reproducibility of Results</topic><topic>Sensitivity and Specificity</topic><topic>Solvents - chemistry</topic><topic>Tandem Mass Spectrometry - methods</topic><topic>Time Factors</topic><topic>Vitamin K 2 - analogs &amp; derivatives</topic><topic>Vitamin K 2 - blood</topic><topic>Vitamin K 2 - metabolism</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Kang, Wonku</creatorcontrib><creatorcontrib>Jeong, Ji-Hoon</creatorcontrib><creatorcontrib>Ma, Eunsook</creatorcontrib><creatorcontrib>Kwon, Kwang-il</creatorcontrib><collection>Pascal-Francis</collection><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><jtitle>Journal of pharmaceutical and biomedical analysis</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Kang, Wonku</au><au>Jeong, Ji-Hoon</au><au>Ma, Eunsook</au><au>Kwon, Kwang-il</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Simple and sensitive determination of menatetrenone and its epoxide metabolite in human plasma</atitle><jtitle>Journal of pharmaceutical and biomedical analysis</jtitle><addtitle>J Pharm Biomed Anal</addtitle><date>2007-09-03</date><risdate>2007</risdate><volume>44</volume><issue>5</issue><spage>1178</spage><epage>1182</epage><pages>1178-1182</pages><issn>0731-7085</issn><eissn>1873-264X</eissn><coden>JPBADA</coden><abstract>A simple and rapid quantification method was developed for determining menatetrenone and its epoxide metabolite in human plasma. After a simple protein precipitation with methanol, the analytes were chromatographed on a reversed-phase C 18 column and detected by LC/MS/MS with atmospheric pressure chemical ionization. The coefficient of variation of the assay precision was less than 10.1%, and the accuracy ranged from 98.0 to 106.5%. The limit of detection of menatetrenone and its epoxide was 0.5 and 0.2 ng/ml, respectively. This method was used to simultaneously measure the plasma concentration of menatetrenone and its epoxide metabolite from healthy subjects after a single 30 mg oral dose of menatetrenone.</abstract><cop>Amsterdam</cop><pub>Elsevier B.V</pub><pmid>17561362</pmid><doi>10.1016/j.jpba.2007.04.028</doi><tpages>5</tpages></addata></record>
fulltext fulltext
identifier ISSN: 0731-7085
ispartof Journal of pharmaceutical and biomedical analysis, 2007-09, Vol.44 (5), p.1178-1182
issn 0731-7085
1873-264X
language eng
recordid cdi_proquest_miscellaneous_68178753
source MEDLINE; Elsevier ScienceDirect Journals Complete
subjects Analysis
Analytical, structural and metabolic biochemistry
Biological and medical sciences
Chromatography, Liquid - methods
Epoxide metabolite
Epoxy Compounds - blood
Fundamental and applied biological sciences. Psychology
General pharmacology
Hemostatics - blood
Hemostatics - metabolism
Humans
LC/MS/MS
Medical sciences
Menatetrenone
Methanol - chemistry
Pharmacology. Drug treatments
Reference Standards
Reproducibility of Results
Sensitivity and Specificity
Solvents - chemistry
Tandem Mass Spectrometry - methods
Time Factors
Vitamin K 2 - analogs & derivatives
Vitamin K 2 - blood
Vitamin K 2 - metabolism
title Simple and sensitive determination of menatetrenone and its epoxide metabolite in human plasma
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-28T11%3A28%3A03IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Simple%20and%20sensitive%20determination%20of%20menatetrenone%20and%20its%20epoxide%20metabolite%20in%20human%20plasma&rft.jtitle=Journal%20of%20pharmaceutical%20and%20biomedical%20analysis&rft.au=Kang,%20Wonku&rft.date=2007-09-03&rft.volume=44&rft.issue=5&rft.spage=1178&rft.epage=1182&rft.pages=1178-1182&rft.issn=0731-7085&rft.eissn=1873-264X&rft.coden=JPBADA&rft_id=info:doi/10.1016/j.jpba.2007.04.028&rft_dat=%3Cproquest_cross%3E68178753%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=68178753&rft_id=info:pmid/17561362&rft_els_id=S0731708507002439&rfr_iscdi=true