Influence of self-etchant application time on bracket shear bond strength

To determine the influence of self-etching primer (SEP) application time on the shear bond strength of orthodontic brackets. Forty human molars were cleaned, mounted, and randomly divided into two groups. The same SEP, adhesive, and brackets were used in both groups. Twenty teeth were conditioned fo...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:The Angle orthodontist 2007-09, Vol.77 (5), p.885-889
Hauptverfasser: Ostby, Adam Wade, Bishara, Samir E, Laffoon, John, Warren, John J
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 889
container_issue 5
container_start_page 885
container_title The Angle orthodontist
container_volume 77
creator Ostby, Adam Wade
Bishara, Samir E
Laffoon, John
Warren, John J
description To determine the influence of self-etching primer (SEP) application time on the shear bond strength of orthodontic brackets. Forty human molars were cleaned, mounted, and randomly divided into two groups. The same SEP, adhesive, and brackets were used in both groups. Twenty teeth were conditioned following the manufacturers' recommendations by rubbing the SEP on the enamel surface for 3 to 5 seconds. The remaining 20 teeth were conditioned using the same SEP, but the application time was increased to 15 seconds. The teeth were debonded within half an hour following initial bonding using a universal testing machine. After debonding, the amount of residual adhesive remaining on the tooth was determined. Student's t-test was used to compare the shear bond strength (SBS) of the two groups, and the chi2 test was used to compare the Adhesive Remnant Index (ARI) scores for the two adhesive systems. The mean SBS of the brackets bonded to the teeth subjected to the SEP for 3 to 5 seconds was 8.0+/-4.6 MPa and was not significantly different (t=-0.69, P=.494) from the SBS of the brackets bonded using a 15-second SEP application time (x=8.9+/-3.4 MPa). The comparisons of the ARI scores between the two groups (chi2=2.16) indicated that bracket failure mode was not significantly different (P=.340) for both groups, and most failures were at the bracket-adhesive interface. The present findings indicate that increasing the SEP application from 3 to 5 seconds to 15 seconds does not result in a significant increase in SBS.
doi_str_mv 10.2319/092006-383
format Article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_68144523</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>68144523</sourcerecordid><originalsourceid>FETCH-LOGICAL-c387t-6b7894662f03beabc2311edc68906da196e44d2d22b3ec2253c8f4d4bd7a34af3</originalsourceid><addsrcrecordid>eNpF0DtPwzAUhmELgWgpLPwA5IkBKeBbHGdEVYFKlVhgjnw5poHECbYz8O8JaiWmszz6pPMidE3JPeO0fiA1I0QWXPETtKS1KIuKEn6KloQQXnBG6wW6SOmTEFaWgp2jBa2kKitFl2i7Db6bIFjAg8cJOl9AtnsdMtbj2LVW53YIOLf9DAI2UdsvyDjtQUdshuBwyhHCR95fojOvuwRXx7tC70-bt_VLsXt93q4fd4XlqsqFNJWqhZTME25AGzu_QMFZqWoinaa1BCEcc4wZDpaxklvlhRPGVZoL7fkK3R52xzh8T5By07fJQtfpAMOUGqmoECXjM7w7QBuHlCL4Zoxtr-NPQ0nzF645hGvmcDO-Oa5Opgf3T4-l-C_MeGf4</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>68144523</pqid></control><display><type>article</type><title>Influence of self-etchant application time on bracket shear bond strength</title><source>MEDLINE</source><source>DOAJ Directory of Open Access Journals</source><source>EZB-FREE-00999 freely available EZB journals</source><creator>Ostby, Adam Wade ; Bishara, Samir E ; Laffoon, John ; Warren, John J</creator><creatorcontrib>Ostby, Adam Wade ; Bishara, Samir E ; Laffoon, John ; Warren, John J</creatorcontrib><description>To determine the influence of self-etching primer (SEP) application time on the shear bond strength of orthodontic brackets. Forty human molars were cleaned, mounted, and randomly divided into two groups. The same SEP, adhesive, and brackets were used in both groups. Twenty teeth were conditioned following the manufacturers' recommendations by rubbing the SEP on the enamel surface for 3 to 5 seconds. The remaining 20 teeth were conditioned using the same SEP, but the application time was increased to 15 seconds. The teeth were debonded within half an hour following initial bonding using a universal testing machine. After debonding, the amount of residual adhesive remaining on the tooth was determined. Student's t-test was used to compare the shear bond strength (SBS) of the two groups, and the chi2 test was used to compare the Adhesive Remnant Index (ARI) scores for the two adhesive systems. The mean SBS of the brackets bonded to the teeth subjected to the SEP for 3 to 5 seconds was 8.0+/-4.6 MPa and was not significantly different (t=-0.69, P=.494) from the SBS of the brackets bonded using a 15-second SEP application time (x=8.9+/-3.4 MPa). The comparisons of the ARI scores between the two groups (chi2=2.16) indicated that bracket failure mode was not significantly different (P=.340) for both groups, and most failures were at the bracket-adhesive interface. The present findings indicate that increasing the SEP application from 3 to 5 seconds to 15 seconds does not result in a significant increase in SBS.</description><identifier>ISSN: 0003-3219</identifier><identifier>EISSN: 1945-7103</identifier><identifier>DOI: 10.2319/092006-383</identifier><identifier>PMID: 17685781</identifier><language>eng</language><publisher>United States</publisher><subject>Acid Etching, Dental - adverse effects ; Acid Etching, Dental - methods ; Chi-Square Distribution ; Dental Bonding - methods ; Dental Enamel - ultrastructure ; Dentistry ; Humans ; Microscopy, Electron, Scanning ; Orthodontic Brackets ; Shear Strength ; Time Factors</subject><ispartof>The Angle orthodontist, 2007-09, Vol.77 (5), p.885-889</ispartof><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c387t-6b7894662f03beabc2311edc68906da196e44d2d22b3ec2253c8f4d4bd7a34af3</citedby><cites>FETCH-LOGICAL-c387t-6b7894662f03beabc2311edc68906da196e44d2d22b3ec2253c8f4d4bd7a34af3</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,777,781,861,27905,27906</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/17685781$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Ostby, Adam Wade</creatorcontrib><creatorcontrib>Bishara, Samir E</creatorcontrib><creatorcontrib>Laffoon, John</creatorcontrib><creatorcontrib>Warren, John J</creatorcontrib><title>Influence of self-etchant application time on bracket shear bond strength</title><title>The Angle orthodontist</title><addtitle>Angle Orthod</addtitle><description>To determine the influence of self-etching primer (SEP) application time on the shear bond strength of orthodontic brackets. Forty human molars were cleaned, mounted, and randomly divided into two groups. The same SEP, adhesive, and brackets were used in both groups. Twenty teeth were conditioned following the manufacturers' recommendations by rubbing the SEP on the enamel surface for 3 to 5 seconds. The remaining 20 teeth were conditioned using the same SEP, but the application time was increased to 15 seconds. The teeth were debonded within half an hour following initial bonding using a universal testing machine. After debonding, the amount of residual adhesive remaining on the tooth was determined. Student's t-test was used to compare the shear bond strength (SBS) of the two groups, and the chi2 test was used to compare the Adhesive Remnant Index (ARI) scores for the two adhesive systems. The mean SBS of the brackets bonded to the teeth subjected to the SEP for 3 to 5 seconds was 8.0+/-4.6 MPa and was not significantly different (t=-0.69, P=.494) from the SBS of the brackets bonded using a 15-second SEP application time (x=8.9+/-3.4 MPa). The comparisons of the ARI scores between the two groups (chi2=2.16) indicated that bracket failure mode was not significantly different (P=.340) for both groups, and most failures were at the bracket-adhesive interface. The present findings indicate that increasing the SEP application from 3 to 5 seconds to 15 seconds does not result in a significant increase in SBS.</description><subject>Acid Etching, Dental - adverse effects</subject><subject>Acid Etching, Dental - methods</subject><subject>Chi-Square Distribution</subject><subject>Dental Bonding - methods</subject><subject>Dental Enamel - ultrastructure</subject><subject>Dentistry</subject><subject>Humans</subject><subject>Microscopy, Electron, Scanning</subject><subject>Orthodontic Brackets</subject><subject>Shear Strength</subject><subject>Time Factors</subject><issn>0003-3219</issn><issn>1945-7103</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2007</creationdate><recordtype>article</recordtype><sourceid>EIF</sourceid><recordid>eNpF0DtPwzAUhmELgWgpLPwA5IkBKeBbHGdEVYFKlVhgjnw5poHECbYz8O8JaiWmszz6pPMidE3JPeO0fiA1I0QWXPETtKS1KIuKEn6KloQQXnBG6wW6SOmTEFaWgp2jBa2kKitFl2i7Db6bIFjAg8cJOl9AtnsdMtbj2LVW53YIOLf9DAI2UdsvyDjtQUdshuBwyhHCR95fojOvuwRXx7tC70-bt_VLsXt93q4fd4XlqsqFNJWqhZTME25AGzu_QMFZqWoinaa1BCEcc4wZDpaxklvlhRPGVZoL7fkK3R52xzh8T5By07fJQtfpAMOUGqmoECXjM7w7QBuHlCL4Zoxtr-NPQ0nzF645hGvmcDO-Oa5Opgf3T4-l-C_MeGf4</recordid><startdate>20070901</startdate><enddate>20070901</enddate><creator>Ostby, Adam Wade</creator><creator>Bishara, Samir E</creator><creator>Laffoon, John</creator><creator>Warren, John J</creator><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope></search><sort><creationdate>20070901</creationdate><title>Influence of self-etchant application time on bracket shear bond strength</title><author>Ostby, Adam Wade ; Bishara, Samir E ; Laffoon, John ; Warren, John J</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c387t-6b7894662f03beabc2311edc68906da196e44d2d22b3ec2253c8f4d4bd7a34af3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2007</creationdate><topic>Acid Etching, Dental - adverse effects</topic><topic>Acid Etching, Dental - methods</topic><topic>Chi-Square Distribution</topic><topic>Dental Bonding - methods</topic><topic>Dental Enamel - ultrastructure</topic><topic>Dentistry</topic><topic>Humans</topic><topic>Microscopy, Electron, Scanning</topic><topic>Orthodontic Brackets</topic><topic>Shear Strength</topic><topic>Time Factors</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Ostby, Adam Wade</creatorcontrib><creatorcontrib>Bishara, Samir E</creatorcontrib><creatorcontrib>Laffoon, John</creatorcontrib><creatorcontrib>Warren, John J</creatorcontrib><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><jtitle>The Angle orthodontist</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Ostby, Adam Wade</au><au>Bishara, Samir E</au><au>Laffoon, John</au><au>Warren, John J</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Influence of self-etchant application time on bracket shear bond strength</atitle><jtitle>The Angle orthodontist</jtitle><addtitle>Angle Orthod</addtitle><date>2007-09-01</date><risdate>2007</risdate><volume>77</volume><issue>5</issue><spage>885</spage><epage>889</epage><pages>885-889</pages><issn>0003-3219</issn><eissn>1945-7103</eissn><abstract>To determine the influence of self-etching primer (SEP) application time on the shear bond strength of orthodontic brackets. Forty human molars were cleaned, mounted, and randomly divided into two groups. The same SEP, adhesive, and brackets were used in both groups. Twenty teeth were conditioned following the manufacturers' recommendations by rubbing the SEP on the enamel surface for 3 to 5 seconds. The remaining 20 teeth were conditioned using the same SEP, but the application time was increased to 15 seconds. The teeth were debonded within half an hour following initial bonding using a universal testing machine. After debonding, the amount of residual adhesive remaining on the tooth was determined. Student's t-test was used to compare the shear bond strength (SBS) of the two groups, and the chi2 test was used to compare the Adhesive Remnant Index (ARI) scores for the two adhesive systems. The mean SBS of the brackets bonded to the teeth subjected to the SEP for 3 to 5 seconds was 8.0+/-4.6 MPa and was not significantly different (t=-0.69, P=.494) from the SBS of the brackets bonded using a 15-second SEP application time (x=8.9+/-3.4 MPa). The comparisons of the ARI scores between the two groups (chi2=2.16) indicated that bracket failure mode was not significantly different (P=.340) for both groups, and most failures were at the bracket-adhesive interface. The present findings indicate that increasing the SEP application from 3 to 5 seconds to 15 seconds does not result in a significant increase in SBS.</abstract><cop>United States</cop><pmid>17685781</pmid><doi>10.2319/092006-383</doi><tpages>5</tpages><oa>free_for_read</oa></addata></record>
fulltext fulltext
identifier ISSN: 0003-3219
ispartof The Angle orthodontist, 2007-09, Vol.77 (5), p.885-889
issn 0003-3219
1945-7103
language eng
recordid cdi_proquest_miscellaneous_68144523
source MEDLINE; DOAJ Directory of Open Access Journals; EZB-FREE-00999 freely available EZB journals
subjects Acid Etching, Dental - adverse effects
Acid Etching, Dental - methods
Chi-Square Distribution
Dental Bonding - methods
Dental Enamel - ultrastructure
Dentistry
Humans
Microscopy, Electron, Scanning
Orthodontic Brackets
Shear Strength
Time Factors
title Influence of self-etchant application time on bracket shear bond strength
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-17T20%3A27%3A08IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Influence%20of%20self-etchant%20application%20time%20on%20bracket%20shear%20bond%20strength&rft.jtitle=The%20Angle%20orthodontist&rft.au=Ostby,%20Adam%20Wade&rft.date=2007-09-01&rft.volume=77&rft.issue=5&rft.spage=885&rft.epage=889&rft.pages=885-889&rft.issn=0003-3219&rft.eissn=1945-7103&rft_id=info:doi/10.2319/092006-383&rft_dat=%3Cproquest_cross%3E68144523%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=68144523&rft_id=info:pmid/17685781&rfr_iscdi=true