The carrier gas pressure effect in a laminar flow diffusion chamber, homogeneous nucleation of n -butanol in helium
Homogeneous nucleation rate isotherms of n - butanol + helium were measured in a laminar flow diffusion chamber at total pressures ranging from 50 to 210 kPa to investigate the effect of carrier gas pressure on nucleation. Nucleation temperatures ranged from 265 to 280 K and the measured nucleation...
Gespeichert in:
Veröffentlicht in: | The Journal of chemical physics 2006-06, Vol.124 (22), p.224304-224304-11 |
---|---|
Hauptverfasser: | , , , , , , |
Format: | Artikel |
Sprache: | eng |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | Homogeneous nucleation rate isotherms of
n
-
butanol
+
helium
were measured in a laminar flow diffusion chamber at total pressures ranging from
50
to
210
kPa
to investigate the effect of carrier gas pressure on nucleation. Nucleation temperatures ranged from
265
to
280
K
and the measured nucleation rates were between
10
2
and
10
6
cm
−
3
s
−
1
. The measured nucleation rates decreased as a function of increasing pressure. The pressure effect was strongest at pressures below
100
kPa
. This negative carrier gas effect was also temperature dependent. At nucleation temperature of
280
K
and at the same saturation ratio, the maximum deviation between nucleation rates measured at 50 and
210
kPa
was about three orders of magnitude. At nucleation temperature of
265
K
, the effect was negligible. Qualitatively the results resemble those measured in a thermal diffusion cloud chamber. Also the slopes of the isothermal nucleation rates as a function of saturation ratio were different as a function of total pressure,
50
kPa
isotherms yielded the steepest slopes, and
210
kPa
isotherms the shallowest slopes. Several sources of inaccuracies were considered in the interpretation of the results: uncertainties in the transport properties, nonideal behavior of the vapor-carrier gas mixture, and shortcomings of the used mathematical model. Operation characteristics of the laminar flow diffusion chamber at both under-and overpressure were determined to verify a correct and stable operation of the device. We conclude that a negative carrier gas pressure effect is seen in the laminar flow diffusion chamber and it cannot be totally explained with the aforementioned reasons. |
---|---|
ISSN: | 0021-9606 1089-7690 |
DOI: | 10.1063/1.2200341 |