Low-Cost Approaches to Robust Temperature Compensation in Near-Infrared Calibration and Prediction Situations
The traditional way of handling temperature shifts and other perturbations in calibration situations is to incorporate the non-relevant spectral variation in the calibration set by measuring the samples at various conditions. The present paper proposes two low-cost approaches based on simulation and...
Gespeichert in:
Veröffentlicht in: | Applied spectroscopy 2005-06, Vol.59 (6), p.816-825 |
---|---|
Hauptverfasser: | , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
container_end_page | 825 |
---|---|
container_issue | 6 |
container_start_page | 816 |
container_title | Applied spectroscopy |
container_volume | 59 |
creator | Segtnan, Vegard H. Mevik, Bjørn-Helge Isaksson, Tomas Næs, Tormod |
description | The traditional way of handling temperature shifts and other perturbations in calibration situations is to incorporate the non-relevant spectral variation in the calibration set by measuring the samples at various conditions. The present paper proposes two low-cost approaches based on simulation and prior knowledge about the perturbations, and these are compared to traditional methods. The first approach is based on augmentation of the calibration matrix through adding simulated noise on the spectra. The second approach is a correction method that removes the non-relevant variation from new spectra. Neither method demands exact knowledge of the perturbation levels. Using the augmentation method it was found that a few, in this case four, selected samples run under different conditions gave approximately the same robustness as running all the calibration samples under different conditions. For the carbohydrate data set, all robustification methods investigated worked well, including the use of pure water spectra for temperature compensation. For the more complex meat data set, only the augmentation method gave comparable results to the full global model. |
doi_str_mv | 10.1366/0003702054280586 |
format | Article |
fullrecord | <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_68094536</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sage_id>10.1366_0003702054280586</sage_id><sourcerecordid>68094536</sourcerecordid><originalsourceid>FETCH-LOGICAL-c335t-1a534f000cd509d1fae99136125a877c4ac6e0450abcce41e997b556d88a7e553</originalsourceid><addsrcrecordid>eNp1UE1LxDAQDaK46-rdk_TkrZpsOml7lOLHwqKi67lM06l2aZuatIj_3uwHCIKn-XhvHvMeY-eCXwmp1DXnXMZ8ziGaJxwSdcCmIo1kKEHyQzbdwKHHkwk7cW7tR0glHLOJUBwkRMmUtUvzFWbGDcFN31uD-oNcMJjgxRSjX66o7cniMFoKMuP7zuFQmy6ou-CR0IaLrrJoqQwybOrC7kDsyuDZL2u9HV_rYdwC7pQdVdg4OtvXGXu7u11lD-Hy6X6R3SxDLSUMoUCQUeXf1SXwtBQVUpp6w2IOmMSxjlAr4hFwLLSmSHg0LgBUmSQYE4Ccscudrrf0OZIb8rZ2mpoGOzKjy1XC0wik8kS-I2prnLNU5b2tW7TfueD5JuL8b8T-5GKvPRYtlb8H-0w9IdwRHL5Tvjaj7bzX_wV_AA9ThB8</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>68094536</pqid></control><display><type>article</type><title>Low-Cost Approaches to Robust Temperature Compensation in Near-Infrared Calibration and Prediction Situations</title><source>MEDLINE</source><source>SAGE Complete A-Z List</source><creator>Segtnan, Vegard H. ; Mevik, Bjørn-Helge ; Isaksson, Tomas ; Næs, Tormod</creator><creatorcontrib>Segtnan, Vegard H. ; Mevik, Bjørn-Helge ; Isaksson, Tomas ; Næs, Tormod</creatorcontrib><description>The traditional way of handling temperature shifts and other perturbations in calibration situations is to incorporate the non-relevant spectral variation in the calibration set by measuring the samples at various conditions. The present paper proposes two low-cost approaches based on simulation and prior knowledge about the perturbations, and these are compared to traditional methods. The first approach is based on augmentation of the calibration matrix through adding simulated noise on the spectra. The second approach is a correction method that removes the non-relevant variation from new spectra. Neither method demands exact knowledge of the perturbation levels. Using the augmentation method it was found that a few, in this case four, selected samples run under different conditions gave approximately the same robustness as running all the calibration samples under different conditions. For the carbohydrate data set, all robustification methods investigated worked well, including the use of pure water spectra for temperature compensation. For the more complex meat data set, only the augmentation method gave comparable results to the full global model.</description><identifier>ISSN: 0003-7028</identifier><identifier>EISSN: 1943-3530</identifier><identifier>DOI: 10.1366/0003702054280586</identifier><identifier>PMID: 16053548</identifier><language>eng</language><publisher>London, England: SAGE Publications</publisher><subject>Algorithms ; Animals ; Calibration ; Carbohydrates - analysis ; Cattle ; Computer Simulation ; Meat - analysis ; Models, Chemical ; Spectroscopy, Fourier Transform Infrared - instrumentation ; Spectroscopy, Fourier Transform Infrared - methods ; Spectroscopy, Fourier Transform Infrared - standards ; Temperature</subject><ispartof>Applied spectroscopy, 2005-06, Vol.59 (6), p.816-825</ispartof><rights>2005 Society for Applied Spectroscopy</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c335t-1a534f000cd509d1fae99136125a877c4ac6e0450abcce41e997b556d88a7e553</citedby><cites>FETCH-LOGICAL-c335t-1a534f000cd509d1fae99136125a877c4ac6e0450abcce41e997b556d88a7e553</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktopdf>$$Uhttps://journals.sagepub.com/doi/pdf/10.1366/0003702054280586$$EPDF$$P50$$Gsage$$H</linktopdf><linktohtml>$$Uhttps://journals.sagepub.com/doi/10.1366/0003702054280586$$EHTML$$P50$$Gsage$$H</linktohtml><link.rule.ids>314,777,781,21800,27905,27906,43602,43603</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/16053548$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Segtnan, Vegard H.</creatorcontrib><creatorcontrib>Mevik, Bjørn-Helge</creatorcontrib><creatorcontrib>Isaksson, Tomas</creatorcontrib><creatorcontrib>Næs, Tormod</creatorcontrib><title>Low-Cost Approaches to Robust Temperature Compensation in Near-Infrared Calibration and Prediction Situations</title><title>Applied spectroscopy</title><addtitle>Appl Spectrosc</addtitle><description>The traditional way of handling temperature shifts and other perturbations in calibration situations is to incorporate the non-relevant spectral variation in the calibration set by measuring the samples at various conditions. The present paper proposes two low-cost approaches based on simulation and prior knowledge about the perturbations, and these are compared to traditional methods. The first approach is based on augmentation of the calibration matrix through adding simulated noise on the spectra. The second approach is a correction method that removes the non-relevant variation from new spectra. Neither method demands exact knowledge of the perturbation levels. Using the augmentation method it was found that a few, in this case four, selected samples run under different conditions gave approximately the same robustness as running all the calibration samples under different conditions. For the carbohydrate data set, all robustification methods investigated worked well, including the use of pure water spectra for temperature compensation. For the more complex meat data set, only the augmentation method gave comparable results to the full global model.</description><subject>Algorithms</subject><subject>Animals</subject><subject>Calibration</subject><subject>Carbohydrates - analysis</subject><subject>Cattle</subject><subject>Computer Simulation</subject><subject>Meat - analysis</subject><subject>Models, Chemical</subject><subject>Spectroscopy, Fourier Transform Infrared - instrumentation</subject><subject>Spectroscopy, Fourier Transform Infrared - methods</subject><subject>Spectroscopy, Fourier Transform Infrared - standards</subject><subject>Temperature</subject><issn>0003-7028</issn><issn>1943-3530</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2005</creationdate><recordtype>article</recordtype><sourceid>EIF</sourceid><recordid>eNp1UE1LxDAQDaK46-rdk_TkrZpsOml7lOLHwqKi67lM06l2aZuatIj_3uwHCIKn-XhvHvMeY-eCXwmp1DXnXMZ8ziGaJxwSdcCmIo1kKEHyQzbdwKHHkwk7cW7tR0glHLOJUBwkRMmUtUvzFWbGDcFN31uD-oNcMJjgxRSjX66o7cniMFoKMuP7zuFQmy6ou-CR0IaLrrJoqQwybOrC7kDsyuDZL2u9HV_rYdwC7pQdVdg4OtvXGXu7u11lD-Hy6X6R3SxDLSUMoUCQUeXf1SXwtBQVUpp6w2IOmMSxjlAr4hFwLLSmSHg0LgBUmSQYE4Ccscudrrf0OZIb8rZ2mpoGOzKjy1XC0wik8kS-I2prnLNU5b2tW7TfueD5JuL8b8T-5GKvPRYtlb8H-0w9IdwRHL5Tvjaj7bzX_wV_AA9ThB8</recordid><startdate>200506</startdate><enddate>200506</enddate><creator>Segtnan, Vegard H.</creator><creator>Mevik, Bjørn-Helge</creator><creator>Isaksson, Tomas</creator><creator>Næs, Tormod</creator><general>SAGE Publications</general><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope></search><sort><creationdate>200506</creationdate><title>Low-Cost Approaches to Robust Temperature Compensation in Near-Infrared Calibration and Prediction Situations</title><author>Segtnan, Vegard H. ; Mevik, Bjørn-Helge ; Isaksson, Tomas ; Næs, Tormod</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c335t-1a534f000cd509d1fae99136125a877c4ac6e0450abcce41e997b556d88a7e553</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2005</creationdate><topic>Algorithms</topic><topic>Animals</topic><topic>Calibration</topic><topic>Carbohydrates - analysis</topic><topic>Cattle</topic><topic>Computer Simulation</topic><topic>Meat - analysis</topic><topic>Models, Chemical</topic><topic>Spectroscopy, Fourier Transform Infrared - instrumentation</topic><topic>Spectroscopy, Fourier Transform Infrared - methods</topic><topic>Spectroscopy, Fourier Transform Infrared - standards</topic><topic>Temperature</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Segtnan, Vegard H.</creatorcontrib><creatorcontrib>Mevik, Bjørn-Helge</creatorcontrib><creatorcontrib>Isaksson, Tomas</creatorcontrib><creatorcontrib>Næs, Tormod</creatorcontrib><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><jtitle>Applied spectroscopy</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Segtnan, Vegard H.</au><au>Mevik, Bjørn-Helge</au><au>Isaksson, Tomas</au><au>Næs, Tormod</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Low-Cost Approaches to Robust Temperature Compensation in Near-Infrared Calibration and Prediction Situations</atitle><jtitle>Applied spectroscopy</jtitle><addtitle>Appl Spectrosc</addtitle><date>2005-06</date><risdate>2005</risdate><volume>59</volume><issue>6</issue><spage>816</spage><epage>825</epage><pages>816-825</pages><issn>0003-7028</issn><eissn>1943-3530</eissn><abstract>The traditional way of handling temperature shifts and other perturbations in calibration situations is to incorporate the non-relevant spectral variation in the calibration set by measuring the samples at various conditions. The present paper proposes two low-cost approaches based on simulation and prior knowledge about the perturbations, and these are compared to traditional methods. The first approach is based on augmentation of the calibration matrix through adding simulated noise on the spectra. The second approach is a correction method that removes the non-relevant variation from new spectra. Neither method demands exact knowledge of the perturbation levels. Using the augmentation method it was found that a few, in this case four, selected samples run under different conditions gave approximately the same robustness as running all the calibration samples under different conditions. For the carbohydrate data set, all robustification methods investigated worked well, including the use of pure water spectra for temperature compensation. For the more complex meat data set, only the augmentation method gave comparable results to the full global model.</abstract><cop>London, England</cop><pub>SAGE Publications</pub><pmid>16053548</pmid><doi>10.1366/0003702054280586</doi><tpages>10</tpages></addata></record> |
fulltext | fulltext |
identifier | ISSN: 0003-7028 |
ispartof | Applied spectroscopy, 2005-06, Vol.59 (6), p.816-825 |
issn | 0003-7028 1943-3530 |
language | eng |
recordid | cdi_proquest_miscellaneous_68094536 |
source | MEDLINE; SAGE Complete A-Z List |
subjects | Algorithms Animals Calibration Carbohydrates - analysis Cattle Computer Simulation Meat - analysis Models, Chemical Spectroscopy, Fourier Transform Infrared - instrumentation Spectroscopy, Fourier Transform Infrared - methods Spectroscopy, Fourier Transform Infrared - standards Temperature |
title | Low-Cost Approaches to Robust Temperature Compensation in Near-Infrared Calibration and Prediction Situations |
url | https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-19T13%3A22%3A43IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Low-Cost%20Approaches%20to%20Robust%20Temperature%20Compensation%20in%20Near-Infrared%20Calibration%20and%20Prediction%20Situations&rft.jtitle=Applied%20spectroscopy&rft.au=Segtnan,%20Vegard%20H.&rft.date=2005-06&rft.volume=59&rft.issue=6&rft.spage=816&rft.epage=825&rft.pages=816-825&rft.issn=0003-7028&rft.eissn=1943-3530&rft_id=info:doi/10.1366/0003702054280586&rft_dat=%3Cproquest_cross%3E68094536%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=68094536&rft_id=info:pmid/16053548&rft_sage_id=10.1366_0003702054280586&rfr_iscdi=true |