Risk-Adjusted Outcome Analysis of Endovascular Abdominal Aortic Aneurysm Repair in a Large Population: How Do Stent-Grafts Compare?

Purpose: To compare differences in the applicability and incidence of postoperative adverse events among stent-grafts used for repair of infrarenal aortic aneurysms. Methods: An analysis of 6787 patients from the EUROSTAR Registry database was conducted to compare aneurysm morphological features, pa...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Journal of endovascular therapy 2005-08, Vol.12 (4), p.417-429
Hauptverfasser: van Marrewijk, Corine J., Leurs, Lina J., Vallabhaneni, Srinivasa R., Harris, Peter L., Buth, Jacob, Laheij, Robert J.F.
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!