Effect of peroxide-based bleaching agents on enamel ultimate tensile strength
This study evaluated the effects of peroxide bleaching regimens on the ultimate tensile strength (UTS) of human enamel. A resin composite block was built-up on the bonded occlusal surface of 14 extracted, sound, erupted third molars to enable posterior preparation for the microtensile test. The bond...
Gespeichert in:
Veröffentlicht in: | Operative dentistry 2005-05, Vol.30 (3), p.318-324 |
---|---|
Hauptverfasser: | , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
container_end_page | 324 |
---|---|
container_issue | 3 |
container_start_page | 318 |
container_title | Operative dentistry |
container_volume | 30 |
creator | da Silva, Alessandra Peres de Oliveira, Rogério Cavalli, Vanessa Arrais, César Augusto Galvão Giannini, Marcelo de Carvalho, Ricardo Marins |
description | This study evaluated the effects of peroxide bleaching regimens on the ultimate tensile strength (UTS) of human enamel. A resin composite block was built-up on the bonded occlusal surface of 14 extracted, sound, erupted third molars to enable posterior preparation for the microtensile test. The bonded teeth were serially sectioned in a buccal-lingual direction into approximately 0.7-mm thick slices. Each slice was trimmed with a fine diamond bur to reduce the area of the buccal, internal slope of the cusps to a dumb-bell shape with a cross-sectional area of less than 1 mm2. The samples were randomly divided into seven groups (n = 10): unbleached control group and bleached groups treated with six bleaching regimens. The specimens were tested in tension at 0.5 mm/minute and the data were analyzed by ANOVA and Tukey test. Specimens from the control group presented 51.3 +/- 8.6 MPa, while the UTS of bleached enamel ranged from 22.0 +/- 5.6 to 36.3 +/- 9.1 MPa. All bleaching procedures significantly reduced enamel UTS (p < 0.05). Differences were also observed among treatments. The results suggested that bleaching regimens can significantly reduce enamel UTS. |
format | Article |
fullrecord | <record><control><sourceid>proquest_pubme</sourceid><recordid>TN_cdi_proquest_miscellaneous_67982821</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>67982821</sourcerecordid><originalsourceid>FETCH-LOGICAL-p209t-21a006755577aa85dc923ae67b5edf8c7053fe414b3fa3909ecba2108fd312f73</originalsourceid><addsrcrecordid>eNo1kL1OwzAYRT2AaCm8AvLEFsk_cRyPqCo_UhELzNFn-3Mb5DghdiR4eypRprMcHV3dC7JmsuGV1rJekeucPxmrVa3UFVlxZdrGKL4mr7sQ0BU6BjrhPH73HisLGT21EcEd-3SgcMBUMh0TxQQDRrrE0g9QkBZMuY9Ic5kxHcrxhlwGiBlvz9yQj8fd-_a52r89vWwf9tUkmCmV4MBYo5VSWgO0yjsjJGCjrUIfWqeZkgFrXlsZQBpm0FkQnLXBSy6Clhty_9ed5vFrwVy6oc8OY4SE45K7RptWtIKfxLuzuNgBfTfNp-HzT_d_gPwFtclWpQ</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>67982821</pqid></control><display><type>article</type><title>Effect of peroxide-based bleaching agents on enamel ultimate tensile strength</title><source>MEDLINE</source><source>Allen Press Journals</source><source>Elektronische Zeitschriftenbibliothek - Frei zugängliche E-Journals</source><source>Alma/SFX Local Collection</source><creator>da Silva, Alessandra Peres ; de Oliveira, Rogério ; Cavalli, Vanessa ; Arrais, César Augusto Galvão ; Giannini, Marcelo ; de Carvalho, Ricardo Marins</creator><creatorcontrib>da Silva, Alessandra Peres ; de Oliveira, Rogério ; Cavalli, Vanessa ; Arrais, César Augusto Galvão ; Giannini, Marcelo ; de Carvalho, Ricardo Marins</creatorcontrib><description>This study evaluated the effects of peroxide bleaching regimens on the ultimate tensile strength (UTS) of human enamel. A resin composite block was built-up on the bonded occlusal surface of 14 extracted, sound, erupted third molars to enable posterior preparation for the microtensile test. The bonded teeth were serially sectioned in a buccal-lingual direction into approximately 0.7-mm thick slices. Each slice was trimmed with a fine diamond bur to reduce the area of the buccal, internal slope of the cusps to a dumb-bell shape with a cross-sectional area of less than 1 mm2. The samples were randomly divided into seven groups (n = 10): unbleached control group and bleached groups treated with six bleaching regimens. The specimens were tested in tension at 0.5 mm/minute and the data were analyzed by ANOVA and Tukey test. Specimens from the control group presented 51.3 +/- 8.6 MPa, while the UTS of bleached enamel ranged from 22.0 +/- 5.6 to 36.3 +/- 9.1 MPa. All bleaching procedures significantly reduced enamel UTS (p < 0.05). Differences were also observed among treatments. The results suggested that bleaching regimens can significantly reduce enamel UTS.</description><identifier>ISSN: 0361-7734</identifier><identifier>PMID: 15986951</identifier><language>eng</language><publisher>United States</publisher><subject>Analysis of Variance ; Dental Enamel - chemistry ; Dental Enamel - drug effects ; Dentistry ; Drug Combinations ; Humans ; Hydrogen Peroxide - pharmacology ; Molar, Third - chemistry ; Molar, Third - drug effects ; Peroxides - pharmacology ; Tensile Strength - drug effects ; Tooth Bleaching ; Urea - analogs & derivatives ; Urea - pharmacology</subject><ispartof>Operative dentistry, 2005-05, Vol.30 (3), p.318-324</ispartof><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,777,781</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/15986951$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>da Silva, Alessandra Peres</creatorcontrib><creatorcontrib>de Oliveira, Rogério</creatorcontrib><creatorcontrib>Cavalli, Vanessa</creatorcontrib><creatorcontrib>Arrais, César Augusto Galvão</creatorcontrib><creatorcontrib>Giannini, Marcelo</creatorcontrib><creatorcontrib>de Carvalho, Ricardo Marins</creatorcontrib><title>Effect of peroxide-based bleaching agents on enamel ultimate tensile strength</title><title>Operative dentistry</title><addtitle>Oper Dent</addtitle><description>This study evaluated the effects of peroxide bleaching regimens on the ultimate tensile strength (UTS) of human enamel. A resin composite block was built-up on the bonded occlusal surface of 14 extracted, sound, erupted third molars to enable posterior preparation for the microtensile test. The bonded teeth were serially sectioned in a buccal-lingual direction into approximately 0.7-mm thick slices. Each slice was trimmed with a fine diamond bur to reduce the area of the buccal, internal slope of the cusps to a dumb-bell shape with a cross-sectional area of less than 1 mm2. The samples were randomly divided into seven groups (n = 10): unbleached control group and bleached groups treated with six bleaching regimens. The specimens were tested in tension at 0.5 mm/minute and the data were analyzed by ANOVA and Tukey test. Specimens from the control group presented 51.3 +/- 8.6 MPa, while the UTS of bleached enamel ranged from 22.0 +/- 5.6 to 36.3 +/- 9.1 MPa. All bleaching procedures significantly reduced enamel UTS (p < 0.05). Differences were also observed among treatments. The results suggested that bleaching regimens can significantly reduce enamel UTS.</description><subject>Analysis of Variance</subject><subject>Dental Enamel - chemistry</subject><subject>Dental Enamel - drug effects</subject><subject>Dentistry</subject><subject>Drug Combinations</subject><subject>Humans</subject><subject>Hydrogen Peroxide - pharmacology</subject><subject>Molar, Third - chemistry</subject><subject>Molar, Third - drug effects</subject><subject>Peroxides - pharmacology</subject><subject>Tensile Strength - drug effects</subject><subject>Tooth Bleaching</subject><subject>Urea - analogs & derivatives</subject><subject>Urea - pharmacology</subject><issn>0361-7734</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2005</creationdate><recordtype>article</recordtype><sourceid>EIF</sourceid><recordid>eNo1kL1OwzAYRT2AaCm8AvLEFsk_cRyPqCo_UhELzNFn-3Mb5DghdiR4eypRprMcHV3dC7JmsuGV1rJekeucPxmrVa3UFVlxZdrGKL4mr7sQ0BU6BjrhPH73HisLGT21EcEd-3SgcMBUMh0TxQQDRrrE0g9QkBZMuY9Ic5kxHcrxhlwGiBlvz9yQj8fd-_a52r89vWwf9tUkmCmV4MBYo5VSWgO0yjsjJGCjrUIfWqeZkgFrXlsZQBpm0FkQnLXBSy6Clhty_9ed5vFrwVy6oc8OY4SE45K7RptWtIKfxLuzuNgBfTfNp-HzT_d_gPwFtclWpQ</recordid><startdate>200505</startdate><enddate>200505</enddate><creator>da Silva, Alessandra Peres</creator><creator>de Oliveira, Rogério</creator><creator>Cavalli, Vanessa</creator><creator>Arrais, César Augusto Galvão</creator><creator>Giannini, Marcelo</creator><creator>de Carvalho, Ricardo Marins</creator><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>7X8</scope></search><sort><creationdate>200505</creationdate><title>Effect of peroxide-based bleaching agents on enamel ultimate tensile strength</title><author>da Silva, Alessandra Peres ; de Oliveira, Rogério ; Cavalli, Vanessa ; Arrais, César Augusto Galvão ; Giannini, Marcelo ; de Carvalho, Ricardo Marins</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-p209t-21a006755577aa85dc923ae67b5edf8c7053fe414b3fa3909ecba2108fd312f73</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2005</creationdate><topic>Analysis of Variance</topic><topic>Dental Enamel - chemistry</topic><topic>Dental Enamel - drug effects</topic><topic>Dentistry</topic><topic>Drug Combinations</topic><topic>Humans</topic><topic>Hydrogen Peroxide - pharmacology</topic><topic>Molar, Third - chemistry</topic><topic>Molar, Third - drug effects</topic><topic>Peroxides - pharmacology</topic><topic>Tensile Strength - drug effects</topic><topic>Tooth Bleaching</topic><topic>Urea - analogs & derivatives</topic><topic>Urea - pharmacology</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>da Silva, Alessandra Peres</creatorcontrib><creatorcontrib>de Oliveira, Rogério</creatorcontrib><creatorcontrib>Cavalli, Vanessa</creatorcontrib><creatorcontrib>Arrais, César Augusto Galvão</creatorcontrib><creatorcontrib>Giannini, Marcelo</creatorcontrib><creatorcontrib>de Carvalho, Ricardo Marins</creatorcontrib><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>MEDLINE - Academic</collection><jtitle>Operative dentistry</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>da Silva, Alessandra Peres</au><au>de Oliveira, Rogério</au><au>Cavalli, Vanessa</au><au>Arrais, César Augusto Galvão</au><au>Giannini, Marcelo</au><au>de Carvalho, Ricardo Marins</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Effect of peroxide-based bleaching agents on enamel ultimate tensile strength</atitle><jtitle>Operative dentistry</jtitle><addtitle>Oper Dent</addtitle><date>2005-05</date><risdate>2005</risdate><volume>30</volume><issue>3</issue><spage>318</spage><epage>324</epage><pages>318-324</pages><issn>0361-7734</issn><abstract>This study evaluated the effects of peroxide bleaching regimens on the ultimate tensile strength (UTS) of human enamel. A resin composite block was built-up on the bonded occlusal surface of 14 extracted, sound, erupted third molars to enable posterior preparation for the microtensile test. The bonded teeth were serially sectioned in a buccal-lingual direction into approximately 0.7-mm thick slices. Each slice was trimmed with a fine diamond bur to reduce the area of the buccal, internal slope of the cusps to a dumb-bell shape with a cross-sectional area of less than 1 mm2. The samples were randomly divided into seven groups (n = 10): unbleached control group and bleached groups treated with six bleaching regimens. The specimens were tested in tension at 0.5 mm/minute and the data were analyzed by ANOVA and Tukey test. Specimens from the control group presented 51.3 +/- 8.6 MPa, while the UTS of bleached enamel ranged from 22.0 +/- 5.6 to 36.3 +/- 9.1 MPa. All bleaching procedures significantly reduced enamel UTS (p < 0.05). Differences were also observed among treatments. The results suggested that bleaching regimens can significantly reduce enamel UTS.</abstract><cop>United States</cop><pmid>15986951</pmid><tpages>7</tpages></addata></record> |
fulltext | fulltext |
identifier | ISSN: 0361-7734 |
ispartof | Operative dentistry, 2005-05, Vol.30 (3), p.318-324 |
issn | 0361-7734 |
language | eng |
recordid | cdi_proquest_miscellaneous_67982821 |
source | MEDLINE; Allen Press Journals; Elektronische Zeitschriftenbibliothek - Frei zugängliche E-Journals; Alma/SFX Local Collection |
subjects | Analysis of Variance Dental Enamel - chemistry Dental Enamel - drug effects Dentistry Drug Combinations Humans Hydrogen Peroxide - pharmacology Molar, Third - chemistry Molar, Third - drug effects Peroxides - pharmacology Tensile Strength - drug effects Tooth Bleaching Urea - analogs & derivatives Urea - pharmacology |
title | Effect of peroxide-based bleaching agents on enamel ultimate tensile strength |
url | https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-21T05%3A32%3A18IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_pubme&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Effect%20of%20peroxide-based%20bleaching%20agents%20on%20enamel%20ultimate%20tensile%20strength&rft.jtitle=Operative%20dentistry&rft.au=da%20Silva,%20Alessandra%20Peres&rft.date=2005-05&rft.volume=30&rft.issue=3&rft.spage=318&rft.epage=324&rft.pages=318-324&rft.issn=0361-7734&rft_id=info:doi/&rft_dat=%3Cproquest_pubme%3E67982821%3C/proquest_pubme%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=67982821&rft_id=info:pmid/15986951&rfr_iscdi=true |