Rapid determination of trace amounts of minoxidil in hamster skin follicles with various formulations using narrow-bore LC/EC

A sensitive liquid chromatographic method with electrochemistry (LC/EC) was developed for the determination of trace of minoxidil in hamster skin follicles after topical administration of the ear using various formulations. The minoxidil in the sebaceous glands of the hamster ear was isolated from t...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Journal of pharmaceutical and biomedical analysis 2005-07, Vol.38 (3), p.532-536
Hauptverfasser: Huang, Tiehua, Garceau, Michelle E., Ramstad, Tore, Stehle, Randall G.
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 536
container_issue 3
container_start_page 532
container_title Journal of pharmaceutical and biomedical analysis
container_volume 38
creator Huang, Tiehua
Garceau, Michelle E.
Ramstad, Tore
Stehle, Randall G.
description A sensitive liquid chromatographic method with electrochemistry (LC/EC) was developed for the determination of trace of minoxidil in hamster skin follicles after topical administration of the ear using various formulations. The minoxidil in the sebaceous glands of the hamster ear was isolated from the skin and the follicles in different skin layers were treated with aqueous trichloroacetic acid followed by acetonitrile. The supernatant was directly injected into the LC/EC system and minoxidil was detected by oxidation at +800 mV versus Ag/AgCl using a glassy carbon electrode. The analytical recoveries were between 94.4 and103.1% and the linearity was excellent up to 250 μg/ml with a regression coefficient ( r 2) of 0.9988. The LC/EC and the widely used radiolabeled scintillation methods agree well and both show high sensitivities. The LC/EC method is rapid and cost-effective with a detection limit of only 1 ng/ml.
doi_str_mv 10.1016/j.jpba.2005.01.032
format Article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_67882956</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><els_id>S073170850500083X</els_id><sourcerecordid>67882956</sourcerecordid><originalsourceid>FETCH-LOGICAL-c384t-2fbcfec4706ae5a9cb209d8e0733b6e81ff238af1f0a292391ca5a7113754b683</originalsourceid><addsrcrecordid>eNp9kE-L1DAYh4Mo7rj6BTxILu6t3SRt0hS8yLD-gQFBFLyFt-kbN2PajEm7qwe_uxlnYG-eQt48vx9vHkJeclZzxtX1vt4fBqgFY7JmvGaNeEQ2XHdNJVT77THZsK7hVce0vCDPct6zAvK-fUouuOyFFFJtyJ_PcPAjHXHBNPkZFh9nGh1dElikMMV1XvJxUB7jLz_6QP1Mb2HKJUDzj3JxMQRvA2Z675dbegfJxzWXcZrW8K8w0zX7-TudIaV4Xw0xId1tr2-2z8kTByHji_N5Sb6-u_my_VDtPr3_uH27q2yj26USbrAObdsxBSiht4Ng_aix_K8ZFGrunGg0OO4YiF40PbcgoeO86WQ7KN1ckqtT7yHFnyvmxUw-WwwBZiy7GtVpLXqpCihOoE0x54TOHJKfIP02nJmjdLM3R-nmKN0wbor0Enp1bl-HCceHyNlyAV6fAcgWgkswW58fOKUV060s3JsTh8XFncdksvU4Wxx9QruYMfr_7fEXozWiTA</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>67882956</pqid></control><display><type>article</type><title>Rapid determination of trace amounts of minoxidil in hamster skin follicles with various formulations using narrow-bore LC/EC</title><source>MEDLINE</source><source>Elsevier ScienceDirect Journals</source><creator>Huang, Tiehua ; Garceau, Michelle E. ; Ramstad, Tore ; Stehle, Randall G.</creator><creatorcontrib>Huang, Tiehua ; Garceau, Michelle E. ; Ramstad, Tore ; Stehle, Randall G.</creatorcontrib><description>A sensitive liquid chromatographic method with electrochemistry (LC/EC) was developed for the determination of trace of minoxidil in hamster skin follicles after topical administration of the ear using various formulations. The minoxidil in the sebaceous glands of the hamster ear was isolated from the skin and the follicles in different skin layers were treated with aqueous trichloroacetic acid followed by acetonitrile. The supernatant was directly injected into the LC/EC system and minoxidil was detected by oxidation at +800 mV versus Ag/AgCl using a glassy carbon electrode. The analytical recoveries were between 94.4 and103.1% and the linearity was excellent up to 250 μg/ml with a regression coefficient ( r 2) of 0.9988. The LC/EC and the widely used radiolabeled scintillation methods agree well and both show high sensitivities. The LC/EC method is rapid and cost-effective with a detection limit of only 1 ng/ml.</description><identifier>ISSN: 0731-7085</identifier><identifier>EISSN: 1873-264X</identifier><identifier>DOI: 10.1016/j.jpba.2005.01.032</identifier><identifier>PMID: 15925256</identifier><identifier>CODEN: JPBADA</identifier><language>eng</language><publisher>Amsterdam: Elsevier B.V</publisher><subject>Analysis ; Analytical, structural and metabolic biochemistry ; Animals ; Biological and medical sciences ; Chromatography, High Pressure Liquid - methods ; Cricetinae ; Dermis - metabolism ; Dosage Forms ; Ear ; Electrochemical detection ; Electrochemistry - methods ; Follicles ; Formulation ; Fundamental and applied biological sciences. Psychology ; General pharmacology ; Hydrogen-Ion Concentration ; Medical sciences ; Microbore liquid chromatography ; Minoxidil ; Minoxidil - analysis ; Minoxidil - isolation &amp; purification ; Minoxidil - pharmacokinetics ; Pharmacology. Drug treatments ; Polyethylene Glycols - chemistry ; Reproducibility of Results ; Sebaceous Glands - metabolism ; Solubility ; Solvents - chemistry ; Trichloroacetic Acid - chemistry</subject><ispartof>Journal of pharmaceutical and biomedical analysis, 2005-07, Vol.38 (3), p.532-536</ispartof><rights>2005</rights><rights>2005 INIST-CNRS</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c384t-2fbcfec4706ae5a9cb209d8e0733b6e81ff238af1f0a292391ca5a7113754b683</citedby><cites>FETCH-LOGICAL-c384t-2fbcfec4706ae5a9cb209d8e0733b6e81ff238af1f0a292391ca5a7113754b683</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://dx.doi.org/10.1016/j.jpba.2005.01.032$$EHTML$$P50$$Gelsevier$$H</linktohtml><link.rule.ids>314,777,781,3537,27905,27906,45976</link.rule.ids><backlink>$$Uhttp://pascal-francis.inist.fr/vibad/index.php?action=getRecordDetail&amp;idt=16860845$$DView record in Pascal Francis$$Hfree_for_read</backlink><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/15925256$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Huang, Tiehua</creatorcontrib><creatorcontrib>Garceau, Michelle E.</creatorcontrib><creatorcontrib>Ramstad, Tore</creatorcontrib><creatorcontrib>Stehle, Randall G.</creatorcontrib><title>Rapid determination of trace amounts of minoxidil in hamster skin follicles with various formulations using narrow-bore LC/EC</title><title>Journal of pharmaceutical and biomedical analysis</title><addtitle>J Pharm Biomed Anal</addtitle><description>A sensitive liquid chromatographic method with electrochemistry (LC/EC) was developed for the determination of trace of minoxidil in hamster skin follicles after topical administration of the ear using various formulations. The minoxidil in the sebaceous glands of the hamster ear was isolated from the skin and the follicles in different skin layers were treated with aqueous trichloroacetic acid followed by acetonitrile. The supernatant was directly injected into the LC/EC system and minoxidil was detected by oxidation at +800 mV versus Ag/AgCl using a glassy carbon electrode. The analytical recoveries were between 94.4 and103.1% and the linearity was excellent up to 250 μg/ml with a regression coefficient ( r 2) of 0.9988. The LC/EC and the widely used radiolabeled scintillation methods agree well and both show high sensitivities. The LC/EC method is rapid and cost-effective with a detection limit of only 1 ng/ml.</description><subject>Analysis</subject><subject>Analytical, structural and metabolic biochemistry</subject><subject>Animals</subject><subject>Biological and medical sciences</subject><subject>Chromatography, High Pressure Liquid - methods</subject><subject>Cricetinae</subject><subject>Dermis - metabolism</subject><subject>Dosage Forms</subject><subject>Ear</subject><subject>Electrochemical detection</subject><subject>Electrochemistry - methods</subject><subject>Follicles</subject><subject>Formulation</subject><subject>Fundamental and applied biological sciences. Psychology</subject><subject>General pharmacology</subject><subject>Hydrogen-Ion Concentration</subject><subject>Medical sciences</subject><subject>Microbore liquid chromatography</subject><subject>Minoxidil</subject><subject>Minoxidil - analysis</subject><subject>Minoxidil - isolation &amp; purification</subject><subject>Minoxidil - pharmacokinetics</subject><subject>Pharmacology. Drug treatments</subject><subject>Polyethylene Glycols - chemistry</subject><subject>Reproducibility of Results</subject><subject>Sebaceous Glands - metabolism</subject><subject>Solubility</subject><subject>Solvents - chemistry</subject><subject>Trichloroacetic Acid - chemistry</subject><issn>0731-7085</issn><issn>1873-264X</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2005</creationdate><recordtype>article</recordtype><sourceid>EIF</sourceid><recordid>eNp9kE-L1DAYh4Mo7rj6BTxILu6t3SRt0hS8yLD-gQFBFLyFt-kbN2PajEm7qwe_uxlnYG-eQt48vx9vHkJeclZzxtX1vt4fBqgFY7JmvGaNeEQ2XHdNJVT77THZsK7hVce0vCDPct6zAvK-fUouuOyFFFJtyJ_PcPAjHXHBNPkZFh9nGh1dElikMMV1XvJxUB7jLz_6QP1Mb2HKJUDzj3JxMQRvA2Z675dbegfJxzWXcZrW8K8w0zX7-TudIaV4Xw0xId1tr2-2z8kTByHji_N5Sb6-u_my_VDtPr3_uH27q2yj26USbrAObdsxBSiht4Ng_aix_K8ZFGrunGg0OO4YiF40PbcgoeO86WQ7KN1ckqtT7yHFnyvmxUw-WwwBZiy7GtVpLXqpCihOoE0x54TOHJKfIP02nJmjdLM3R-nmKN0wbor0Enp1bl-HCceHyNlyAV6fAcgWgkswW58fOKUV060s3JsTh8XFncdksvU4Wxx9QruYMfr_7fEXozWiTA</recordid><startdate>20050701</startdate><enddate>20050701</enddate><creator>Huang, Tiehua</creator><creator>Garceau, Michelle E.</creator><creator>Ramstad, Tore</creator><creator>Stehle, Randall G.</creator><general>Elsevier B.V</general><general>Elsevier Science</general><scope>IQODW</scope><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope></search><sort><creationdate>20050701</creationdate><title>Rapid determination of trace amounts of minoxidil in hamster skin follicles with various formulations using narrow-bore LC/EC</title><author>Huang, Tiehua ; Garceau, Michelle E. ; Ramstad, Tore ; Stehle, Randall G.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c384t-2fbcfec4706ae5a9cb209d8e0733b6e81ff238af1f0a292391ca5a7113754b683</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2005</creationdate><topic>Analysis</topic><topic>Analytical, structural and metabolic biochemistry</topic><topic>Animals</topic><topic>Biological and medical sciences</topic><topic>Chromatography, High Pressure Liquid - methods</topic><topic>Cricetinae</topic><topic>Dermis - metabolism</topic><topic>Dosage Forms</topic><topic>Ear</topic><topic>Electrochemical detection</topic><topic>Electrochemistry - methods</topic><topic>Follicles</topic><topic>Formulation</topic><topic>Fundamental and applied biological sciences. Psychology</topic><topic>General pharmacology</topic><topic>Hydrogen-Ion Concentration</topic><topic>Medical sciences</topic><topic>Microbore liquid chromatography</topic><topic>Minoxidil</topic><topic>Minoxidil - analysis</topic><topic>Minoxidil - isolation &amp; purification</topic><topic>Minoxidil - pharmacokinetics</topic><topic>Pharmacology. Drug treatments</topic><topic>Polyethylene Glycols - chemistry</topic><topic>Reproducibility of Results</topic><topic>Sebaceous Glands - metabolism</topic><topic>Solubility</topic><topic>Solvents - chemistry</topic><topic>Trichloroacetic Acid - chemistry</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Huang, Tiehua</creatorcontrib><creatorcontrib>Garceau, Michelle E.</creatorcontrib><creatorcontrib>Ramstad, Tore</creatorcontrib><creatorcontrib>Stehle, Randall G.</creatorcontrib><collection>Pascal-Francis</collection><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><jtitle>Journal of pharmaceutical and biomedical analysis</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Huang, Tiehua</au><au>Garceau, Michelle E.</au><au>Ramstad, Tore</au><au>Stehle, Randall G.</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Rapid determination of trace amounts of minoxidil in hamster skin follicles with various formulations using narrow-bore LC/EC</atitle><jtitle>Journal of pharmaceutical and biomedical analysis</jtitle><addtitle>J Pharm Biomed Anal</addtitle><date>2005-07-01</date><risdate>2005</risdate><volume>38</volume><issue>3</issue><spage>532</spage><epage>536</epage><pages>532-536</pages><issn>0731-7085</issn><eissn>1873-264X</eissn><coden>JPBADA</coden><abstract>A sensitive liquid chromatographic method with electrochemistry (LC/EC) was developed for the determination of trace of minoxidil in hamster skin follicles after topical administration of the ear using various formulations. The minoxidil in the sebaceous glands of the hamster ear was isolated from the skin and the follicles in different skin layers were treated with aqueous trichloroacetic acid followed by acetonitrile. The supernatant was directly injected into the LC/EC system and minoxidil was detected by oxidation at +800 mV versus Ag/AgCl using a glassy carbon electrode. The analytical recoveries were between 94.4 and103.1% and the linearity was excellent up to 250 μg/ml with a regression coefficient ( r 2) of 0.9988. The LC/EC and the widely used radiolabeled scintillation methods agree well and both show high sensitivities. The LC/EC method is rapid and cost-effective with a detection limit of only 1 ng/ml.</abstract><cop>Amsterdam</cop><pub>Elsevier B.V</pub><pmid>15925256</pmid><doi>10.1016/j.jpba.2005.01.032</doi><tpages>5</tpages></addata></record>
fulltext fulltext
identifier ISSN: 0731-7085
ispartof Journal of pharmaceutical and biomedical analysis, 2005-07, Vol.38 (3), p.532-536
issn 0731-7085
1873-264X
language eng
recordid cdi_proquest_miscellaneous_67882956
source MEDLINE; Elsevier ScienceDirect Journals
subjects Analysis
Analytical, structural and metabolic biochemistry
Animals
Biological and medical sciences
Chromatography, High Pressure Liquid - methods
Cricetinae
Dermis - metabolism
Dosage Forms
Ear
Electrochemical detection
Electrochemistry - methods
Follicles
Formulation
Fundamental and applied biological sciences. Psychology
General pharmacology
Hydrogen-Ion Concentration
Medical sciences
Microbore liquid chromatography
Minoxidil
Minoxidil - analysis
Minoxidil - isolation & purification
Minoxidil - pharmacokinetics
Pharmacology. Drug treatments
Polyethylene Glycols - chemistry
Reproducibility of Results
Sebaceous Glands - metabolism
Solubility
Solvents - chemistry
Trichloroacetic Acid - chemistry
title Rapid determination of trace amounts of minoxidil in hamster skin follicles with various formulations using narrow-bore LC/EC
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-19T07%3A18%3A34IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Rapid%20determination%20of%20trace%20amounts%20of%20minoxidil%20in%20hamster%20skin%20follicles%20with%20various%20formulations%20using%20narrow-bore%20LC/EC&rft.jtitle=Journal%20of%20pharmaceutical%20and%20biomedical%20analysis&rft.au=Huang,%20Tiehua&rft.date=2005-07-01&rft.volume=38&rft.issue=3&rft.spage=532&rft.epage=536&rft.pages=532-536&rft.issn=0731-7085&rft.eissn=1873-264X&rft.coden=JPBADA&rft_id=info:doi/10.1016/j.jpba.2005.01.032&rft_dat=%3Cproquest_cross%3E67882956%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=67882956&rft_id=info:pmid/15925256&rft_els_id=S073170850500083X&rfr_iscdi=true