Safety of Contrast Venography prior to Caval Interruption in Patients with Renal Insufficiency

We undertook this study to determine whether the use of contrast venography would adversely affect renal function in patients with renal insufficiency requiring caval interruption. We conducted a retrospective review of all inferior vena cava (IVC) filters inserted at our institution over a 2-year p...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Annals of vascular surgery 2005-05, Vol.19 (3), p.347-351
Hauptverfasser: D'Ayala, Marcus, Nguyen, Eric T., Deitch, Jonathan S., Degraft-Johnson, John B., Wise, Leslie
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 351
container_issue 3
container_start_page 347
container_title Annals of vascular surgery
container_volume 19
creator D'Ayala, Marcus
Nguyen, Eric T.
Deitch, Jonathan S.
Degraft-Johnson, John B.
Wise, Leslie
description We undertook this study to determine whether the use of contrast venography would adversely affect renal function in patients with renal insufficiency requiring caval interruption. We conducted a retrospective review of all inferior vena cava (IVC) filters inserted at our institution over a 2-year period (January 2002 to January 2004). The indication for caval interruption, insertion technique, type of filter used, pre- and postintervention creatinine level, and the presence of diabetes and hypertension were analyzed. A total of 282 IVC filters were inserted, with 38 of them placed in patients with renal insufficiency as defined by a serum creatinine level of > 1.5 mg/dL. Contrast venography with 15 to 30 mL of iohexol (Omnipaque 300) was used in all cases, and no special measures other than proper hydration were used for renal protection. All filters were successfully deployed. The mean ± SD preintervention creatinine level was 2.38 ± 0.79 mg/dL. The mean ± SD postintervention creatinine levels at 2 and 30 days were 2.26 ± 0.45 mg/dL and 2.12 ± 0.94 mg/dL, respectively. No patients required hemodialysis following caval interruption, and no adverse effect on renal function was noted. Contrast venography accurately delineates venous anatomy and facilitates proper caval filter placement with no apparent adverse effect on renal function. We believe contrast venography is safe even in the presence of renal insufficiency.
doi_str_mv 10.1007/s10016-005-0009-1
format Article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_67866680</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><els_id>S0890509606613368</els_id><sourcerecordid>931209131</sourcerecordid><originalsourceid>FETCH-LOGICAL-c378t-622145421d6f3f56b3a8eb29520f162f2d67d8e0bfcdbf18ca74725dea17c42e3</originalsourceid><addsrcrecordid>eNp9kMlKBDEQhoMoOi4P4EWCB2-tSaaTTuNJBjcQFLejIZ2uOJGZzpiklXl7MwsIHjxU1aG--ik-hA4pOaWEVGcxdyoKQnguUhd0Aw2ooLzgdVltogGRNSk4qcUO2o3xI8NMlnIb7VAuqSw5G6C3J20hzbG3eOS7FHRM-BU6_x70bDzHs-B8wMnjkf7SE3zbJQihnyXnO-w6_KCTgy5F_O3SGD9Ct2Rib60zeWHm-2jL6kmEg_XcQy9Xl8-jm-Lu_vp2dHFXmGElUyEYoyUvGW2FHVoumqGW0LCaM2KpYJa1omolkMaatrFUGl2VFeMtaFqZksFwD52scmfBf_YQk5q6aGAy0R34PipRSSGEJBk8_gN--D7kv6NavMClrGmG6AoywccYwKrsYarDXFGiFubVyrzK5tXCvFrcHK2D-2YK7e_FWnUGzlcAZA9fDoKKS0fQugAmqda7f-J_ALkTke8</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>214558891</pqid></control><display><type>article</type><title>Safety of Contrast Venography prior to Caval Interruption in Patients with Renal Insufficiency</title><source>MEDLINE</source><source>Elsevier ScienceDirect Journals</source><source>Springer Nature - Complete Springer Journals</source><creator>D'Ayala, Marcus ; Nguyen, Eric T. ; Deitch, Jonathan S. ; Degraft-Johnson, John B. ; Wise, Leslie</creator><creatorcontrib>D'Ayala, Marcus ; Nguyen, Eric T. ; Deitch, Jonathan S. ; Degraft-Johnson, John B. ; Wise, Leslie</creatorcontrib><description>We undertook this study to determine whether the use of contrast venography would adversely affect renal function in patients with renal insufficiency requiring caval interruption. We conducted a retrospective review of all inferior vena cava (IVC) filters inserted at our institution over a 2-year period (January 2002 to January 2004). The indication for caval interruption, insertion technique, type of filter used, pre- and postintervention creatinine level, and the presence of diabetes and hypertension were analyzed. A total of 282 IVC filters were inserted, with 38 of them placed in patients with renal insufficiency as defined by a serum creatinine level of &gt; 1.5 mg/dL. Contrast venography with 15 to 30 mL of iohexol (Omnipaque 300) was used in all cases, and no special measures other than proper hydration were used for renal protection. All filters were successfully deployed. The mean ± SD preintervention creatinine level was 2.38 ± 0.79 mg/dL. The mean ± SD postintervention creatinine levels at 2 and 30 days were 2.26 ± 0.45 mg/dL and 2.12 ± 0.94 mg/dL, respectively. No patients required hemodialysis following caval interruption, and no adverse effect on renal function was noted. Contrast venography accurately delineates venous anatomy and facilitates proper caval filter placement with no apparent adverse effect on renal function. We believe contrast venography is safe even in the presence of renal insufficiency.</description><identifier>ISSN: 0890-5096</identifier><identifier>EISSN: 1615-5947</identifier><identifier>DOI: 10.1007/s10016-005-0009-1</identifier><identifier>PMID: 15818452</identifier><identifier>CODEN: AVSUEV</identifier><language>eng</language><publisher>Netherlands: Elsevier Inc</publisher><subject>Adult ; Aged ; Aged, 80 and over ; Creatinine - blood ; Female ; Humans ; Male ; Middle Aged ; Phlebography ; Renal Insufficiency - blood ; Renal Insufficiency - diagnostic imaging ; Vena Cava Filters ; Vena Cava, Inferior - diagnostic imaging</subject><ispartof>Annals of vascular surgery, 2005-05, Vol.19 (3), p.347-351</ispartof><rights>2005 Annals of Vascular Surgery, Inc.</rights><rights>Annals of Vascular Surgery Inc. 2005</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c378t-622145421d6f3f56b3a8eb29520f162f2d67d8e0bfcdbf18ca74725dea17c42e3</citedby><cites>FETCH-LOGICAL-c378t-622145421d6f3f56b3a8eb29520f162f2d67d8e0bfcdbf18ca74725dea17c42e3</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://dx.doi.org/10.1007/s10016-005-0009-1$$EHTML$$P50$$Gelsevier$$H</linktohtml><link.rule.ids>314,777,781,3537,27905,27906,45976</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/15818452$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>D'Ayala, Marcus</creatorcontrib><creatorcontrib>Nguyen, Eric T.</creatorcontrib><creatorcontrib>Deitch, Jonathan S.</creatorcontrib><creatorcontrib>Degraft-Johnson, John B.</creatorcontrib><creatorcontrib>Wise, Leslie</creatorcontrib><title>Safety of Contrast Venography prior to Caval Interruption in Patients with Renal Insufficiency</title><title>Annals of vascular surgery</title><addtitle>Ann Vasc Surg</addtitle><description>We undertook this study to determine whether the use of contrast venography would adversely affect renal function in patients with renal insufficiency requiring caval interruption. We conducted a retrospective review of all inferior vena cava (IVC) filters inserted at our institution over a 2-year period (January 2002 to January 2004). The indication for caval interruption, insertion technique, type of filter used, pre- and postintervention creatinine level, and the presence of diabetes and hypertension were analyzed. A total of 282 IVC filters were inserted, with 38 of them placed in patients with renal insufficiency as defined by a serum creatinine level of &gt; 1.5 mg/dL. Contrast venography with 15 to 30 mL of iohexol (Omnipaque 300) was used in all cases, and no special measures other than proper hydration were used for renal protection. All filters were successfully deployed. The mean ± SD preintervention creatinine level was 2.38 ± 0.79 mg/dL. The mean ± SD postintervention creatinine levels at 2 and 30 days were 2.26 ± 0.45 mg/dL and 2.12 ± 0.94 mg/dL, respectively. No patients required hemodialysis following caval interruption, and no adverse effect on renal function was noted. Contrast venography accurately delineates venous anatomy and facilitates proper caval filter placement with no apparent adverse effect on renal function. We believe contrast venography is safe even in the presence of renal insufficiency.</description><subject>Adult</subject><subject>Aged</subject><subject>Aged, 80 and over</subject><subject>Creatinine - blood</subject><subject>Female</subject><subject>Humans</subject><subject>Male</subject><subject>Middle Aged</subject><subject>Phlebography</subject><subject>Renal Insufficiency - blood</subject><subject>Renal Insufficiency - diagnostic imaging</subject><subject>Vena Cava Filters</subject><subject>Vena Cava, Inferior - diagnostic imaging</subject><issn>0890-5096</issn><issn>1615-5947</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2005</creationdate><recordtype>article</recordtype><sourceid>EIF</sourceid><recordid>eNp9kMlKBDEQhoMoOi4P4EWCB2-tSaaTTuNJBjcQFLejIZ2uOJGZzpiklXl7MwsIHjxU1aG--ik-hA4pOaWEVGcxdyoKQnguUhd0Aw2ooLzgdVltogGRNSk4qcUO2o3xI8NMlnIb7VAuqSw5G6C3J20hzbG3eOS7FHRM-BU6_x70bDzHs-B8wMnjkf7SE3zbJQihnyXnO-w6_KCTgy5F_O3SGD9Ct2Rib60zeWHm-2jL6kmEg_XcQy9Xl8-jm-Lu_vp2dHFXmGElUyEYoyUvGW2FHVoumqGW0LCaM2KpYJa1omolkMaatrFUGl2VFeMtaFqZksFwD52scmfBf_YQk5q6aGAy0R34PipRSSGEJBk8_gN--D7kv6NavMClrGmG6AoywccYwKrsYarDXFGiFubVyrzK5tXCvFrcHK2D-2YK7e_FWnUGzlcAZA9fDoKKS0fQugAmqda7f-J_ALkTke8</recordid><startdate>20050501</startdate><enddate>20050501</enddate><creator>D'Ayala, Marcus</creator><creator>Nguyen, Eric T.</creator><creator>Deitch, Jonathan S.</creator><creator>Degraft-Johnson, John B.</creator><creator>Wise, Leslie</creator><general>Elsevier Inc</general><general>Elsevier Limited</general><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>K9.</scope><scope>7X8</scope></search><sort><creationdate>20050501</creationdate><title>Safety of Contrast Venography prior to Caval Interruption in Patients with Renal Insufficiency</title><author>D'Ayala, Marcus ; Nguyen, Eric T. ; Deitch, Jonathan S. ; Degraft-Johnson, John B. ; Wise, Leslie</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c378t-622145421d6f3f56b3a8eb29520f162f2d67d8e0bfcdbf18ca74725dea17c42e3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2005</creationdate><topic>Adult</topic><topic>Aged</topic><topic>Aged, 80 and over</topic><topic>Creatinine - blood</topic><topic>Female</topic><topic>Humans</topic><topic>Male</topic><topic>Middle Aged</topic><topic>Phlebography</topic><topic>Renal Insufficiency - blood</topic><topic>Renal Insufficiency - diagnostic imaging</topic><topic>Vena Cava Filters</topic><topic>Vena Cava, Inferior - diagnostic imaging</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>D'Ayala, Marcus</creatorcontrib><creatorcontrib>Nguyen, Eric T.</creatorcontrib><creatorcontrib>Deitch, Jonathan S.</creatorcontrib><creatorcontrib>Degraft-Johnson, John B.</creatorcontrib><creatorcontrib>Wise, Leslie</creatorcontrib><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>ProQuest Health &amp; Medical Complete (Alumni)</collection><collection>MEDLINE - Academic</collection><jtitle>Annals of vascular surgery</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>D'Ayala, Marcus</au><au>Nguyen, Eric T.</au><au>Deitch, Jonathan S.</au><au>Degraft-Johnson, John B.</au><au>Wise, Leslie</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Safety of Contrast Venography prior to Caval Interruption in Patients with Renal Insufficiency</atitle><jtitle>Annals of vascular surgery</jtitle><addtitle>Ann Vasc Surg</addtitle><date>2005-05-01</date><risdate>2005</risdate><volume>19</volume><issue>3</issue><spage>347</spage><epage>351</epage><pages>347-351</pages><issn>0890-5096</issn><eissn>1615-5947</eissn><coden>AVSUEV</coden><abstract>We undertook this study to determine whether the use of contrast venography would adversely affect renal function in patients with renal insufficiency requiring caval interruption. We conducted a retrospective review of all inferior vena cava (IVC) filters inserted at our institution over a 2-year period (January 2002 to January 2004). The indication for caval interruption, insertion technique, type of filter used, pre- and postintervention creatinine level, and the presence of diabetes and hypertension were analyzed. A total of 282 IVC filters were inserted, with 38 of them placed in patients with renal insufficiency as defined by a serum creatinine level of &gt; 1.5 mg/dL. Contrast venography with 15 to 30 mL of iohexol (Omnipaque 300) was used in all cases, and no special measures other than proper hydration were used for renal protection. All filters were successfully deployed. The mean ± SD preintervention creatinine level was 2.38 ± 0.79 mg/dL. The mean ± SD postintervention creatinine levels at 2 and 30 days were 2.26 ± 0.45 mg/dL and 2.12 ± 0.94 mg/dL, respectively. No patients required hemodialysis following caval interruption, and no adverse effect on renal function was noted. Contrast venography accurately delineates venous anatomy and facilitates proper caval filter placement with no apparent adverse effect on renal function. We believe contrast venography is safe even in the presence of renal insufficiency.</abstract><cop>Netherlands</cop><pub>Elsevier Inc</pub><pmid>15818452</pmid><doi>10.1007/s10016-005-0009-1</doi><tpages>5</tpages></addata></record>
fulltext fulltext
identifier ISSN: 0890-5096
ispartof Annals of vascular surgery, 2005-05, Vol.19 (3), p.347-351
issn 0890-5096
1615-5947
language eng
recordid cdi_proquest_miscellaneous_67866680
source MEDLINE; Elsevier ScienceDirect Journals; Springer Nature - Complete Springer Journals
subjects Adult
Aged
Aged, 80 and over
Creatinine - blood
Female
Humans
Male
Middle Aged
Phlebography
Renal Insufficiency - blood
Renal Insufficiency - diagnostic imaging
Vena Cava Filters
Vena Cava, Inferior - diagnostic imaging
title Safety of Contrast Venography prior to Caval Interruption in Patients with Renal Insufficiency
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-20T13%3A23%3A47IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Safety%20of%20Contrast%20Venography%20prior%20to%20Caval%20Interruption%20in%20Patients%20with%20Renal%20Insufficiency&rft.jtitle=Annals%20of%20vascular%20surgery&rft.au=D'Ayala,%20Marcus&rft.date=2005-05-01&rft.volume=19&rft.issue=3&rft.spage=347&rft.epage=351&rft.pages=347-351&rft.issn=0890-5096&rft.eissn=1615-5947&rft.coden=AVSUEV&rft_id=info:doi/10.1007/s10016-005-0009-1&rft_dat=%3Cproquest_cross%3E931209131%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=214558891&rft_id=info:pmid/15818452&rft_els_id=S0890509606613368&rfr_iscdi=true