A clinical investigation of the fit of removable partial dental prosthesis clasp assemblies
Removable partial denture frameworks are complex castings fabricated from high-shrinkage alloys. This may result in difficulty in achieving accurate fit. The purpose of this study was to evaluate which component(s) of the clasp assembly contact the abutment tooth clinically. New and existing framewo...
Gespeichert in:
Veröffentlicht in: | The Journal of prosthetic dentistry 2006-04, Vol.95 (4), p.323-326 |
---|---|
Hauptverfasser: | , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
container_end_page | 326 |
---|---|
container_issue | 4 |
container_start_page | 323 |
container_title | The Journal of prosthetic dentistry |
container_volume | 95 |
creator | Dunham, Daniel Brudvik, James S. Morris, W. Jack Plummer, Kevin D. Cameron, Stephen M. |
description | Removable partial denture frameworks are complex castings fabricated from high-shrinkage alloys. This may result in difficulty in achieving accurate fit.
The purpose of this study was to evaluate which component(s) of the clasp assembly contact the abutment tooth clinically.
New and existing frameworks with at least 1 conventional prepared occlusal rest were evaluated for fit. The spacing between the bottom of each of the rests of the 50 clasp assemblies and the corresponding rest seat were recorded with vinyl polysiloxane. The fit of each rest was determined with the use of a dial caliper by measuring, in micrometers, the thickness of the record between the rest and the bottom of the rest seat. The Kennedy classification was also recorded. A 2-sample
t test was used to evaluate the difference in fit between tooth-tissue supported and tooth-supported designs (α=.05).
The average space between the rest and prepared rest seat was 193 ± 203 μm, with a range of 0 to 828 μm. Twenty tooth-tissue frameworks had an average space of 136 ± 160 μm and 30 tooth-supported frameworks had an average space of 230 ± 222 μm. The 2-sample
t test showed no significant difference for fit between tooth-tissue supported and tooth-supported frameworks (
P=.1081). Twenty-four percent of rests had contact in the prepared rest seat.
The majority of rests evaluated did not contact the intended surfaces. |
doi_str_mv | 10.1016/j.prosdent.2006.02.001 |
format | Article |
fullrecord | <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_67860335</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><els_id>S0022391306000576</els_id><sourcerecordid>67860335</sourcerecordid><originalsourceid>FETCH-LOGICAL-c463t-cc472a89fa13dce650167b052f0e661a85d3cc59cf0093bda8e6d017162b65183</originalsourceid><addsrcrecordid>eNqFkEtPwzAQhC0EoqXwF6qcuCXs2o2T3KgqXlIlLnDiYDnOBlzlUWK3Ev8eRy3i2NPu4duZnWFsjpAgoLzbJNuhdxV1PuEAMgGeAOAZmyIUWSzzBZ6zKQDnsShQTNiVcxsAyNMML9kEpUSJAqfsYxmZxnbW6Cay3Z6ct5_a276L-jryXxTV1o_rQG2_12VD0VYP3gZ69A5jfCNwzrogpN020s5RWzaW3DW7qHXj6OY4Z-z98eFt9RyvX59eVst1bBZS-NiYRcZ1XtQaRWVIpiFfVkLKa6Dwp87TShiTFqYGKERZ6ZxkBZih5KVMMRczdnvQDb9870IE1VpnqGl0R_3OKZnlEoRIT4K8SEUQ5gGUB9CEdG6gWm0H2-rhRyGosX-1UX_9q7F_BVyF_sPh_OiwK1uq_s-OhQfg_gBQKGRvaVDOWOoMVXYg41XV21MevzX_mvg</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>29530172</pqid></control><display><type>article</type><title>A clinical investigation of the fit of removable partial dental prosthesis clasp assemblies</title><source>MEDLINE</source><source>Elsevier ScienceDirect Journals</source><creator>Dunham, Daniel ; Brudvik, James S. ; Morris, W. Jack ; Plummer, Kevin D. ; Cameron, Stephen M.</creator><creatorcontrib>Dunham, Daniel ; Brudvik, James S. ; Morris, W. Jack ; Plummer, Kevin D. ; Cameron, Stephen M.</creatorcontrib><description>Removable partial denture frameworks are complex castings fabricated from high-shrinkage alloys. This may result in difficulty in achieving accurate fit.
The purpose of this study was to evaluate which component(s) of the clasp assembly contact the abutment tooth clinically.
New and existing frameworks with at least 1 conventional prepared occlusal rest were evaluated for fit. The spacing between the bottom of each of the rests of the 50 clasp assemblies and the corresponding rest seat were recorded with vinyl polysiloxane. The fit of each rest was determined with the use of a dial caliper by measuring, in micrometers, the thickness of the record between the rest and the bottom of the rest seat. The Kennedy classification was also recorded. A 2-sample
t test was used to evaluate the difference in fit between tooth-tissue supported and tooth-supported designs (α=.05).
The average space between the rest and prepared rest seat was 193 ± 203 μm, with a range of 0 to 828 μm. Twenty tooth-tissue frameworks had an average space of 136 ± 160 μm and 30 tooth-supported frameworks had an average space of 230 ± 222 μm. The 2-sample
t test showed no significant difference for fit between tooth-tissue supported and tooth-supported frameworks (
P=.1081). Twenty-four percent of rests had contact in the prepared rest seat.
The majority of rests evaluated did not contact the intended surfaces.</description><identifier>ISSN: 0022-3913</identifier><identifier>EISSN: 1097-6841</identifier><identifier>DOI: 10.1016/j.prosdent.2006.02.001</identifier><identifier>PMID: 16616131</identifier><language>eng</language><publisher>United States: Mosby, Inc</publisher><subject>Dental Abutments ; Dental Prosthesis Retention - methods ; Dentistry ; Denture Design ; Denture, Partial, Removable ; Humans</subject><ispartof>The Journal of prosthetic dentistry, 2006-04, Vol.95 (4), p.323-326</ispartof><rights>2006 The Editorial Council of The Journal of Prosthetic Dentistry</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c463t-cc472a89fa13dce650167b052f0e661a85d3cc59cf0093bda8e6d017162b65183</citedby><cites>FETCH-LOGICAL-c463t-cc472a89fa13dce650167b052f0e661a85d3cc59cf0093bda8e6d017162b65183</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://www.sciencedirect.com/science/article/pii/S0022391306000576$$EHTML$$P50$$Gelsevier$$H</linktohtml><link.rule.ids>314,776,780,3537,27901,27902,65306</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/16616131$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Dunham, Daniel</creatorcontrib><creatorcontrib>Brudvik, James S.</creatorcontrib><creatorcontrib>Morris, W. Jack</creatorcontrib><creatorcontrib>Plummer, Kevin D.</creatorcontrib><creatorcontrib>Cameron, Stephen M.</creatorcontrib><title>A clinical investigation of the fit of removable partial dental prosthesis clasp assemblies</title><title>The Journal of prosthetic dentistry</title><addtitle>J Prosthet Dent</addtitle><description>Removable partial denture frameworks are complex castings fabricated from high-shrinkage alloys. This may result in difficulty in achieving accurate fit.
The purpose of this study was to evaluate which component(s) of the clasp assembly contact the abutment tooth clinically.
New and existing frameworks with at least 1 conventional prepared occlusal rest were evaluated for fit. The spacing between the bottom of each of the rests of the 50 clasp assemblies and the corresponding rest seat were recorded with vinyl polysiloxane. The fit of each rest was determined with the use of a dial caliper by measuring, in micrometers, the thickness of the record between the rest and the bottom of the rest seat. The Kennedy classification was also recorded. A 2-sample
t test was used to evaluate the difference in fit between tooth-tissue supported and tooth-supported designs (α=.05).
The average space between the rest and prepared rest seat was 193 ± 203 μm, with a range of 0 to 828 μm. Twenty tooth-tissue frameworks had an average space of 136 ± 160 μm and 30 tooth-supported frameworks had an average space of 230 ± 222 μm. The 2-sample
t test showed no significant difference for fit between tooth-tissue supported and tooth-supported frameworks (
P=.1081). Twenty-four percent of rests had contact in the prepared rest seat.
The majority of rests evaluated did not contact the intended surfaces.</description><subject>Dental Abutments</subject><subject>Dental Prosthesis Retention - methods</subject><subject>Dentistry</subject><subject>Denture Design</subject><subject>Denture, Partial, Removable</subject><subject>Humans</subject><issn>0022-3913</issn><issn>1097-6841</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2006</creationdate><recordtype>article</recordtype><sourceid>EIF</sourceid><recordid>eNqFkEtPwzAQhC0EoqXwF6qcuCXs2o2T3KgqXlIlLnDiYDnOBlzlUWK3Ev8eRy3i2NPu4duZnWFsjpAgoLzbJNuhdxV1PuEAMgGeAOAZmyIUWSzzBZ6zKQDnsShQTNiVcxsAyNMML9kEpUSJAqfsYxmZxnbW6Cay3Z6ct5_a276L-jryXxTV1o_rQG2_12VD0VYP3gZ69A5jfCNwzrogpN020s5RWzaW3DW7qHXj6OY4Z-z98eFt9RyvX59eVst1bBZS-NiYRcZ1XtQaRWVIpiFfVkLKa6Dwp87TShiTFqYGKERZ6ZxkBZih5KVMMRczdnvQDb9870IE1VpnqGl0R_3OKZnlEoRIT4K8SEUQ5gGUB9CEdG6gWm0H2-rhRyGosX-1UX_9q7F_BVyF_sPh_OiwK1uq_s-OhQfg_gBQKGRvaVDOWOoMVXYg41XV21MevzX_mvg</recordid><startdate>20060401</startdate><enddate>20060401</enddate><creator>Dunham, Daniel</creator><creator>Brudvik, James S.</creator><creator>Morris, W. Jack</creator><creator>Plummer, Kevin D.</creator><creator>Cameron, Stephen M.</creator><general>Mosby, Inc</general><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7SR</scope><scope>7TB</scope><scope>7U5</scope><scope>8BQ</scope><scope>8FD</scope><scope>F28</scope><scope>FR3</scope><scope>JG9</scope><scope>L7M</scope><scope>7X8</scope></search><sort><creationdate>20060401</creationdate><title>A clinical investigation of the fit of removable partial dental prosthesis clasp assemblies</title><author>Dunham, Daniel ; Brudvik, James S. ; Morris, W. Jack ; Plummer, Kevin D. ; Cameron, Stephen M.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c463t-cc472a89fa13dce650167b052f0e661a85d3cc59cf0093bda8e6d017162b65183</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2006</creationdate><topic>Dental Abutments</topic><topic>Dental Prosthesis Retention - methods</topic><topic>Dentistry</topic><topic>Denture Design</topic><topic>Denture, Partial, Removable</topic><topic>Humans</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Dunham, Daniel</creatorcontrib><creatorcontrib>Brudvik, James S.</creatorcontrib><creatorcontrib>Morris, W. Jack</creatorcontrib><creatorcontrib>Plummer, Kevin D.</creatorcontrib><creatorcontrib>Cameron, Stephen M.</creatorcontrib><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>Engineered Materials Abstracts</collection><collection>Mechanical & Transportation Engineering Abstracts</collection><collection>Solid State and Superconductivity Abstracts</collection><collection>METADEX</collection><collection>Technology Research Database</collection><collection>ANTE: Abstracts in New Technology & Engineering</collection><collection>Engineering Research Database</collection><collection>Materials Research Database</collection><collection>Advanced Technologies Database with Aerospace</collection><collection>MEDLINE - Academic</collection><jtitle>The Journal of prosthetic dentistry</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Dunham, Daniel</au><au>Brudvik, James S.</au><au>Morris, W. Jack</au><au>Plummer, Kevin D.</au><au>Cameron, Stephen M.</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>A clinical investigation of the fit of removable partial dental prosthesis clasp assemblies</atitle><jtitle>The Journal of prosthetic dentistry</jtitle><addtitle>J Prosthet Dent</addtitle><date>2006-04-01</date><risdate>2006</risdate><volume>95</volume><issue>4</issue><spage>323</spage><epage>326</epage><pages>323-326</pages><issn>0022-3913</issn><eissn>1097-6841</eissn><abstract>Removable partial denture frameworks are complex castings fabricated from high-shrinkage alloys. This may result in difficulty in achieving accurate fit.
The purpose of this study was to evaluate which component(s) of the clasp assembly contact the abutment tooth clinically.
New and existing frameworks with at least 1 conventional prepared occlusal rest were evaluated for fit. The spacing between the bottom of each of the rests of the 50 clasp assemblies and the corresponding rest seat were recorded with vinyl polysiloxane. The fit of each rest was determined with the use of a dial caliper by measuring, in micrometers, the thickness of the record between the rest and the bottom of the rest seat. The Kennedy classification was also recorded. A 2-sample
t test was used to evaluate the difference in fit between tooth-tissue supported and tooth-supported designs (α=.05).
The average space between the rest and prepared rest seat was 193 ± 203 μm, with a range of 0 to 828 μm. Twenty tooth-tissue frameworks had an average space of 136 ± 160 μm and 30 tooth-supported frameworks had an average space of 230 ± 222 μm. The 2-sample
t test showed no significant difference for fit between tooth-tissue supported and tooth-supported frameworks (
P=.1081). Twenty-four percent of rests had contact in the prepared rest seat.
The majority of rests evaluated did not contact the intended surfaces.</abstract><cop>United States</cop><pub>Mosby, Inc</pub><pmid>16616131</pmid><doi>10.1016/j.prosdent.2006.02.001</doi><tpages>4</tpages></addata></record> |
fulltext | fulltext |
identifier | ISSN: 0022-3913 |
ispartof | The Journal of prosthetic dentistry, 2006-04, Vol.95 (4), p.323-326 |
issn | 0022-3913 1097-6841 |
language | eng |
recordid | cdi_proquest_miscellaneous_67860335 |
source | MEDLINE; Elsevier ScienceDirect Journals |
subjects | Dental Abutments Dental Prosthesis Retention - methods Dentistry Denture Design Denture, Partial, Removable Humans |
title | A clinical investigation of the fit of removable partial dental prosthesis clasp assemblies |
url | https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-02-10T16%3A36%3A51IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=A%20clinical%20investigation%20of%20the%20fit%20of%20removable%20partial%20dental%20prosthesis%20clasp%20assemblies&rft.jtitle=The%20Journal%20of%20prosthetic%20dentistry&rft.au=Dunham,%20Daniel&rft.date=2006-04-01&rft.volume=95&rft.issue=4&rft.spage=323&rft.epage=326&rft.pages=323-326&rft.issn=0022-3913&rft.eissn=1097-6841&rft_id=info:doi/10.1016/j.prosdent.2006.02.001&rft_dat=%3Cproquest_cross%3E67860335%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=29530172&rft_id=info:pmid/16616131&rft_els_id=S0022391306000576&rfr_iscdi=true |