A Comparison of Laser-Ultrasound Detection System Sensitivity with a Broad-Band Ultrasonic Source for Biomedical Applications

Laser ultrasound detection systems are used for noninvasive imaging of internal structures and function of soft tissues. The detection systems with a high sensitivity can be used for detecting small tumors located deeply in human tissues, such as the breast. In this study, the sensitivity of existin...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Archives of medical research 2006-04, Vol.37 (3), p.322-327
Hauptverfasser: Hejazi, Marjaneh, Abolhassani, Mohamad D., Ahmadian, Alireza, Frenz, M., Jaeger, M., Niederhauser, J.J., Amjadi, A.
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 327
container_issue 3
container_start_page 322
container_title Archives of medical research
container_volume 37
creator Hejazi, Marjaneh
Abolhassani, Mohamad D.
Ahmadian, Alireza
Frenz, M.
Jaeger, M.
Niederhauser, J.J.
Amjadi, A.
description Laser ultrasound detection systems are used for noninvasive imaging of internal structures and function of soft tissues. The detection systems with a high sensitivity can be used for detecting small tumors located deeply in human tissues, such as the breast. In this study, the sensitivity of existing ultrasonic detection systems has been compared experimentally by using thermoelastic waves as a broadband ultrasonic source. For the comparison, an optical stress transducer, a polyvinylidene difluoride (PVDF) sheet and a calibrated PVDF needle hydrophone were used. To ensure that all detection systems were interrogated by the same ultrasonic field, a small optical instrument was constructed to fix the generating laser head. The sensitivity was evaluated by measuring signal-to-noise ratios (SNRs) and noise equivalent pressures (NEPs). The PVDF system, with a 4 kPa NEP, has a 22-dB better performance than the optical stress transducer. The optical stress transducer showed nearly the same sensitivity as the hydrophone for detecting ultrasound waves at a 1-cm distance. PVDF detection system provides a useful tool for imaging of soft tissues because of its high sensitivity and broadband detection range.
doi_str_mv 10.1016/j.arcmed.2005.07.008
format Article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_67713136</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><els_id>S0188440905003048</els_id><sourcerecordid>67713136</sourcerecordid><originalsourceid>FETCH-LOGICAL-c360t-72eda6f55bcafffc1dbe6c61d520b45d9aa89bdfce18183b01c45dc7b4e54eef3</originalsourceid><addsrcrecordid>eNp9kE9v2yAYh1G1ak2zfYNp4rSbXYgxOJdJSdZ_UqQe0pwRhheVyDYe4FY57LuPKNGOO4F4n98PeBD6RklJCeV3h1IF3YMpF4TUJRElIc0VmtFGVEXNGvEJzQhtmoIxsrxBtzEeSCYYF5_RDeU1rZhYztCfFd74flTBRT9gb_FWRQjFvktBRT8NBv-CBDq5PN0dY4Ie72CILrl3l474w6U3rPA6eGWKtcr4JTk4jXd-Chqw9QGvnc9PdVp1eDWOXd6cGuMXdG1VF-HrZZ2j_cP96-ap2L48Pm9W20JXnKRCLMAobuu61cpaq6lpgWtOTb0gLavNUqlm2RqrgTa0qVpCdT7VomVQMwBbzdGPc-8Y_O8JYpK9ixq6Tg3gpyi5ELSiFc8gO4M6-BgDWDkG16twlJTIk3Z5kGft8qRdEiGz1Bz7fumf2tPsX-jiOQM_zwDkX747CDJqB4POTkK2K413_7_hL7dMmSI</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>67713136</pqid></control><display><type>article</type><title>A Comparison of Laser-Ultrasound Detection System Sensitivity with a Broad-Band Ultrasonic Source for Biomedical Applications</title><source>MEDLINE</source><source>Access via ScienceDirect (Elsevier)</source><creator>Hejazi, Marjaneh ; Abolhassani, Mohamad D. ; Ahmadian, Alireza ; Frenz, M. ; Jaeger, M. ; Niederhauser, J.J. ; Amjadi, A.</creator><creatorcontrib>Hejazi, Marjaneh ; Abolhassani, Mohamad D. ; Ahmadian, Alireza ; Frenz, M. ; Jaeger, M. ; Niederhauser, J.J. ; Amjadi, A.</creatorcontrib><description>Laser ultrasound detection systems are used for noninvasive imaging of internal structures and function of soft tissues. The detection systems with a high sensitivity can be used for detecting small tumors located deeply in human tissues, such as the breast. In this study, the sensitivity of existing ultrasonic detection systems has been compared experimentally by using thermoelastic waves as a broadband ultrasonic source. For the comparison, an optical stress transducer, a polyvinylidene difluoride (PVDF) sheet and a calibrated PVDF needle hydrophone were used. To ensure that all detection systems were interrogated by the same ultrasonic field, a small optical instrument was constructed to fix the generating laser head. The sensitivity was evaluated by measuring signal-to-noise ratios (SNRs) and noise equivalent pressures (NEPs). The PVDF system, with a 4 kPa NEP, has a 22-dB better performance than the optical stress transducer. The optical stress transducer showed nearly the same sensitivity as the hydrophone for detecting ultrasound waves at a 1-cm distance. PVDF detection system provides a useful tool for imaging of soft tissues because of its high sensitivity and broadband detection range.</description><identifier>ISSN: 0188-4409</identifier><identifier>EISSN: 1873-5487</identifier><identifier>DOI: 10.1016/j.arcmed.2005.07.008</identifier><identifier>PMID: 16513479</identifier><language>eng</language><publisher>United States: Elsevier Inc</publisher><subject>Biomedical Technology - instrumentation ; Biomedical Technology - methods ; Equipment Design ; Lasers ; Optical stress transducer ; Photoacoustic ; Polyvinylidene difluoride sheet ; Pressure ; Sensitivity ; Sensitivity and Specificity ; Ultrasonics ; Ultrasound laser detection system</subject><ispartof>Archives of medical research, 2006-04, Vol.37 (3), p.322-327</ispartof><rights>2006 IMSS</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c360t-72eda6f55bcafffc1dbe6c61d520b45d9aa89bdfce18183b01c45dc7b4e54eef3</citedby><cites>FETCH-LOGICAL-c360t-72eda6f55bcafffc1dbe6c61d520b45d9aa89bdfce18183b01c45dc7b4e54eef3</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://dx.doi.org/10.1016/j.arcmed.2005.07.008$$EHTML$$P50$$Gelsevier$$H</linktohtml><link.rule.ids>315,782,786,3552,27931,27932,46002</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/16513479$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Hejazi, Marjaneh</creatorcontrib><creatorcontrib>Abolhassani, Mohamad D.</creatorcontrib><creatorcontrib>Ahmadian, Alireza</creatorcontrib><creatorcontrib>Frenz, M.</creatorcontrib><creatorcontrib>Jaeger, M.</creatorcontrib><creatorcontrib>Niederhauser, J.J.</creatorcontrib><creatorcontrib>Amjadi, A.</creatorcontrib><title>A Comparison of Laser-Ultrasound Detection System Sensitivity with a Broad-Band Ultrasonic Source for Biomedical Applications</title><title>Archives of medical research</title><addtitle>Arch Med Res</addtitle><description>Laser ultrasound detection systems are used for noninvasive imaging of internal structures and function of soft tissues. The detection systems with a high sensitivity can be used for detecting small tumors located deeply in human tissues, such as the breast. In this study, the sensitivity of existing ultrasonic detection systems has been compared experimentally by using thermoelastic waves as a broadband ultrasonic source. For the comparison, an optical stress transducer, a polyvinylidene difluoride (PVDF) sheet and a calibrated PVDF needle hydrophone were used. To ensure that all detection systems were interrogated by the same ultrasonic field, a small optical instrument was constructed to fix the generating laser head. The sensitivity was evaluated by measuring signal-to-noise ratios (SNRs) and noise equivalent pressures (NEPs). The PVDF system, with a 4 kPa NEP, has a 22-dB better performance than the optical stress transducer. The optical stress transducer showed nearly the same sensitivity as the hydrophone for detecting ultrasound waves at a 1-cm distance. PVDF detection system provides a useful tool for imaging of soft tissues because of its high sensitivity and broadband detection range.</description><subject>Biomedical Technology - instrumentation</subject><subject>Biomedical Technology - methods</subject><subject>Equipment Design</subject><subject>Lasers</subject><subject>Optical stress transducer</subject><subject>Photoacoustic</subject><subject>Polyvinylidene difluoride sheet</subject><subject>Pressure</subject><subject>Sensitivity</subject><subject>Sensitivity and Specificity</subject><subject>Ultrasonics</subject><subject>Ultrasound laser detection system</subject><issn>0188-4409</issn><issn>1873-5487</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2006</creationdate><recordtype>article</recordtype><sourceid>EIF</sourceid><recordid>eNp9kE9v2yAYh1G1ak2zfYNp4rSbXYgxOJdJSdZ_UqQe0pwRhheVyDYe4FY57LuPKNGOO4F4n98PeBD6RklJCeV3h1IF3YMpF4TUJRElIc0VmtFGVEXNGvEJzQhtmoIxsrxBtzEeSCYYF5_RDeU1rZhYztCfFd74flTBRT9gb_FWRQjFvktBRT8NBv-CBDq5PN0dY4Ie72CILrl3l474w6U3rPA6eGWKtcr4JTk4jXd-Chqw9QGvnc9PdVp1eDWOXd6cGuMXdG1VF-HrZZ2j_cP96-ap2L48Pm9W20JXnKRCLMAobuu61cpaq6lpgWtOTb0gLavNUqlm2RqrgTa0qVpCdT7VomVQMwBbzdGPc-8Y_O8JYpK9ixq6Tg3gpyi5ELSiFc8gO4M6-BgDWDkG16twlJTIk3Z5kGft8qRdEiGz1Bz7fumf2tPsX-jiOQM_zwDkX747CDJqB4POTkK2K413_7_hL7dMmSI</recordid><startdate>20060401</startdate><enddate>20060401</enddate><creator>Hejazi, Marjaneh</creator><creator>Abolhassani, Mohamad D.</creator><creator>Ahmadian, Alireza</creator><creator>Frenz, M.</creator><creator>Jaeger, M.</creator><creator>Niederhauser, J.J.</creator><creator>Amjadi, A.</creator><general>Elsevier Inc</general><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope></search><sort><creationdate>20060401</creationdate><title>A Comparison of Laser-Ultrasound Detection System Sensitivity with a Broad-Band Ultrasonic Source for Biomedical Applications</title><author>Hejazi, Marjaneh ; Abolhassani, Mohamad D. ; Ahmadian, Alireza ; Frenz, M. ; Jaeger, M. ; Niederhauser, J.J. ; Amjadi, A.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c360t-72eda6f55bcafffc1dbe6c61d520b45d9aa89bdfce18183b01c45dc7b4e54eef3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2006</creationdate><topic>Biomedical Technology - instrumentation</topic><topic>Biomedical Technology - methods</topic><topic>Equipment Design</topic><topic>Lasers</topic><topic>Optical stress transducer</topic><topic>Photoacoustic</topic><topic>Polyvinylidene difluoride sheet</topic><topic>Pressure</topic><topic>Sensitivity</topic><topic>Sensitivity and Specificity</topic><topic>Ultrasonics</topic><topic>Ultrasound laser detection system</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Hejazi, Marjaneh</creatorcontrib><creatorcontrib>Abolhassani, Mohamad D.</creatorcontrib><creatorcontrib>Ahmadian, Alireza</creatorcontrib><creatorcontrib>Frenz, M.</creatorcontrib><creatorcontrib>Jaeger, M.</creatorcontrib><creatorcontrib>Niederhauser, J.J.</creatorcontrib><creatorcontrib>Amjadi, A.</creatorcontrib><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><jtitle>Archives of medical research</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Hejazi, Marjaneh</au><au>Abolhassani, Mohamad D.</au><au>Ahmadian, Alireza</au><au>Frenz, M.</au><au>Jaeger, M.</au><au>Niederhauser, J.J.</au><au>Amjadi, A.</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>A Comparison of Laser-Ultrasound Detection System Sensitivity with a Broad-Band Ultrasonic Source for Biomedical Applications</atitle><jtitle>Archives of medical research</jtitle><addtitle>Arch Med Res</addtitle><date>2006-04-01</date><risdate>2006</risdate><volume>37</volume><issue>3</issue><spage>322</spage><epage>327</epage><pages>322-327</pages><issn>0188-4409</issn><eissn>1873-5487</eissn><abstract>Laser ultrasound detection systems are used for noninvasive imaging of internal structures and function of soft tissues. The detection systems with a high sensitivity can be used for detecting small tumors located deeply in human tissues, such as the breast. In this study, the sensitivity of existing ultrasonic detection systems has been compared experimentally by using thermoelastic waves as a broadband ultrasonic source. For the comparison, an optical stress transducer, a polyvinylidene difluoride (PVDF) sheet and a calibrated PVDF needle hydrophone were used. To ensure that all detection systems were interrogated by the same ultrasonic field, a small optical instrument was constructed to fix the generating laser head. The sensitivity was evaluated by measuring signal-to-noise ratios (SNRs) and noise equivalent pressures (NEPs). The PVDF system, with a 4 kPa NEP, has a 22-dB better performance than the optical stress transducer. The optical stress transducer showed nearly the same sensitivity as the hydrophone for detecting ultrasound waves at a 1-cm distance. PVDF detection system provides a useful tool for imaging of soft tissues because of its high sensitivity and broadband detection range.</abstract><cop>United States</cop><pub>Elsevier Inc</pub><pmid>16513479</pmid><doi>10.1016/j.arcmed.2005.07.008</doi><tpages>6</tpages></addata></record>
fulltext fulltext
identifier ISSN: 0188-4409
ispartof Archives of medical research, 2006-04, Vol.37 (3), p.322-327
issn 0188-4409
1873-5487
language eng
recordid cdi_proquest_miscellaneous_67713136
source MEDLINE; Access via ScienceDirect (Elsevier)
subjects Biomedical Technology - instrumentation
Biomedical Technology - methods
Equipment Design
Lasers
Optical stress transducer
Photoacoustic
Polyvinylidene difluoride sheet
Pressure
Sensitivity
Sensitivity and Specificity
Ultrasonics
Ultrasound laser detection system
title A Comparison of Laser-Ultrasound Detection System Sensitivity with a Broad-Band Ultrasonic Source for Biomedical Applications
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-04T12%3A56%3A21IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=A%20Comparison%20of%20Laser-Ultrasound%20Detection%20System%20Sensitivity%20with%20a%20Broad-Band%20Ultrasonic%20Source%20for%20Biomedical%20Applications&rft.jtitle=Archives%20of%20medical%20research&rft.au=Hejazi,%20Marjaneh&rft.date=2006-04-01&rft.volume=37&rft.issue=3&rft.spage=322&rft.epage=327&rft.pages=322-327&rft.issn=0188-4409&rft.eissn=1873-5487&rft_id=info:doi/10.1016/j.arcmed.2005.07.008&rft_dat=%3Cproquest_cross%3E67713136%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=67713136&rft_id=info:pmid/16513479&rft_els_id=S0188440905003048&rfr_iscdi=true