Stent-graft repair for thoracic aortic disease: Results of an independent nationwide study in France from 1999 to 2001

The purpose of this study was to assess the overall short-term outcome of stent-graft repair for thoracic aortic disease in France between June 1999 and May 2001. This retrospective study was designed by the French National Health Insurance Fund for Salaried Workers. To ensure objectivity, data were...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:The Journal of thoracic and cardiovascular surgery 2006, Vol.131 (1), p.131-137
Hauptverfasser: Ricco, Jean-Baptiste, Cau, Jérome, Marchand, Christophe, Marty, Michel, Rodde-Dunet, Marie-Hélène, Fender, Pierre, Allemand, Hubert, Corsini, Andrew
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:The purpose of this study was to assess the overall short-term outcome of stent-graft repair for thoracic aortic disease in France between June 1999 and May 2001. This retrospective study was designed by the French National Health Insurance Fund for Salaried Workers. To ensure objectivity, data were retrieved at each center and checked by a team of medical advisors. Between June 1999 and May 2001, a total of 166 stent-graft repairs for thoracic aortic disease were performed in 166 patients, mainly by surgeons in the operating room (88%). Patients were classified according to the American Society of Anesthesiologists as status I or II in 24% of cases, status III in 56%, and status IV or V in 20%. The diameter of the thoracic aneurysm was less than 50 mm in 17% of cases. Seventeen patients (10%) died during the first 3 months, including 8 within the first 30 days after the procedure. A total of 49 complications were noted in 34 patients (20.5%). Endoleaks occurred in 27 patients (16.3%), including 8 that necessitated further treatment. Other stent-related complications included rupture (n = 3), aortoesophageal or tracheal fistula (n = 3), paraplegia (n = 6), stent migration (n = 2), visceral embolism (n = 5), and cerebral embolism (n = 2). There were 14 delivery-related complications (8%) at the catheterization site. Non–stent-related complications occurred in 14 (8%). This nationwide study demonstrates that stent-graft repair for thoracic aortic disease can be performed with acceptable postoperative morbidity. However, it is not a risk-free procedure and should continue to be used in an investigative setting.
ISSN:0022-5223
1097-685X