Martin’s Rule for High-Performance Liquid Chromatography Retention of Polystyrene Oligomers
The liquid chromatographic retention of polystyrene (PS) oligomer was examined taking the column hold-up volume as an adjustable parameter based on the assumption that Martin’s rule is valid, i.e., ln k (retention factor) is proportional to the degree of polymerization (DP). In both bare silica and...
Gespeichert in:
Veröffentlicht in: | Analytical chemistry (Washington) 2009-07, Vol.81 (14), p.5902-5909 |
---|---|
Hauptverfasser: | , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
container_end_page | 5909 |
---|---|
container_issue | 14 |
container_start_page | 5902 |
container_title | Analytical chemistry (Washington) |
container_volume | 81 |
creator | Kim, Youngtak Ahn, Seonyoung Chang, Taihyun |
description | The liquid chromatographic retention of polystyrene (PS) oligomer was examined taking the column hold-up volume as an adjustable parameter based on the assumption that Martin’s rule is valid, i.e., ln k (retention factor) is proportional to the degree of polymerization (DP). In both bare silica and C18-bonded silica columns, thus determined column hold-up volume is systematically smaller than the elution volume of the injection solvent. When the column hold-up volume was taken as an adjustable parameter, the retention of PS oligomer in organic mobile phase follows Martin’s rule (ln k ∝ DP) near perfectly. In addition, the enthalpy and entropy changes associated with the solute transfer, determined from the temperature dependence of the PS oligomer retention, also show excellent linear dependence on the degree of polymerization if the adjustable column hold-up volume was used. When we compare the retention behavior of PS and hydroxyl terminated PS, the repeating (styrene) unit exhibits the same enthalpy and entropy change while the end group shows the corresponding difference. All observations conform to Martin’s rule regardless of the columns used, but the physical nature of the adjustable column hold-up volume remains to be elucidated. |
doi_str_mv | 10.1021/ac900621f |
format | Article |
fullrecord | <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_67486462</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>1793139871</sourcerecordid><originalsourceid>FETCH-LOGICAL-a436t-e0e551f6aced5b30b0392f104e8d07f0448fd6adfb29815033768df5b33552973</originalsourceid><addsrcrecordid>eNpl0MFqGzEQBmARGhLHzSEvEESghR62HUm7kvYYTBsHHBJCeyyLvDuyFXZXjrR78C2v0dfrk0Qlxob0NHP4mPn5Cblg8JUBZ99MXQJIzuwRmbCCQya15h_IBABExhXAKTmL8QmAMWDyhJyyshBKaZiQ33cmDK7_-_In0sexRWp9oHO3WmcPGNLemb5GunDPo2vobB18Zwa_Cmaz3tJHHLAfnO-pt_TBt9s4bAP2SO9bt_IdhviRHFvTRjzfzSn59eP7z9k8W9zf3M6uF5nJhRwyBCwKZqWpsSmWApYgSm4Z5KgbUBbyXNtGmsYuealZAUIoqRubqCgKXioxJZ_f7m6Cfx4xDlXnYo1ta3r0Y6ykyrXMJU_w6h188mPoU7aKM6VViiMT-vKG6uBjDGirTXCdCduKQfWv8GpfeLKXu4PjssPmIHcNJ_BpB0ysTWtDKtTFveMc0lfFD87U8RDq_4evpjqUNw</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>217874366</pqid></control><display><type>article</type><title>Martin’s Rule for High-Performance Liquid Chromatography Retention of Polystyrene Oligomers</title><source>ACS Publications</source><creator>Kim, Youngtak ; Ahn, Seonyoung ; Chang, Taihyun</creator><creatorcontrib>Kim, Youngtak ; Ahn, Seonyoung ; Chang, Taihyun</creatorcontrib><description>The liquid chromatographic retention of polystyrene (PS) oligomer was examined taking the column hold-up volume as an adjustable parameter based on the assumption that Martin’s rule is valid, i.e., ln k (retention factor) is proportional to the degree of polymerization (DP). In both bare silica and C18-bonded silica columns, thus determined column hold-up volume is systematically smaller than the elution volume of the injection solvent. When the column hold-up volume was taken as an adjustable parameter, the retention of PS oligomer in organic mobile phase follows Martin’s rule (ln k ∝ DP) near perfectly. In addition, the enthalpy and entropy changes associated with the solute transfer, determined from the temperature dependence of the PS oligomer retention, also show excellent linear dependence on the degree of polymerization if the adjustable column hold-up volume was used. When we compare the retention behavior of PS and hydroxyl terminated PS, the repeating (styrene) unit exhibits the same enthalpy and entropy change while the end group shows the corresponding difference. All observations conform to Martin’s rule regardless of the columns used, but the physical nature of the adjustable column hold-up volume remains to be elucidated.</description><identifier>ISSN: 0003-2700</identifier><identifier>EISSN: 1520-6882</identifier><identifier>DOI: 10.1021/ac900621f</identifier><identifier>PMID: 19537780</identifier><identifier>CODEN: ANCHAM</identifier><language>eng</language><publisher>Washington, DC: American Chemical Society</publisher><subject>Analytical chemistry ; Chemistry ; Chromatographic methods and physical methods associated with chromatography ; Chromatography ; Entropy ; Exact sciences and technology ; Other chromatographic methods ; Polystyrene ; Silica ; Thermodynamics</subject><ispartof>Analytical chemistry (Washington), 2009-07, Vol.81 (14), p.5902-5909</ispartof><rights>Copyright © 2009 American Chemical Society</rights><rights>2015 INIST-CNRS</rights><rights>Copyright American Chemical Society Jul 15, 2009</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-a436t-e0e551f6aced5b30b0392f104e8d07f0448fd6adfb29815033768df5b33552973</citedby><cites>FETCH-LOGICAL-a436t-e0e551f6aced5b30b0392f104e8d07f0448fd6adfb29815033768df5b33552973</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktopdf>$$Uhttps://pubs.acs.org/doi/pdf/10.1021/ac900621f$$EPDF$$P50$$Gacs$$H</linktopdf><linktohtml>$$Uhttps://pubs.acs.org/doi/10.1021/ac900621f$$EHTML$$P50$$Gacs$$H</linktohtml><link.rule.ids>314,776,780,2752,27053,27901,27902,56713,56763</link.rule.ids><backlink>$$Uhttp://pascal-francis.inist.fr/vibad/index.php?action=getRecordDetail&idt=22087472$$DView record in Pascal Francis$$Hfree_for_read</backlink><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/19537780$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Kim, Youngtak</creatorcontrib><creatorcontrib>Ahn, Seonyoung</creatorcontrib><creatorcontrib>Chang, Taihyun</creatorcontrib><title>Martin’s Rule for High-Performance Liquid Chromatography Retention of Polystyrene Oligomers</title><title>Analytical chemistry (Washington)</title><addtitle>Anal. Chem</addtitle><description>The liquid chromatographic retention of polystyrene (PS) oligomer was examined taking the column hold-up volume as an adjustable parameter based on the assumption that Martin’s rule is valid, i.e., ln k (retention factor) is proportional to the degree of polymerization (DP). In both bare silica and C18-bonded silica columns, thus determined column hold-up volume is systematically smaller than the elution volume of the injection solvent. When the column hold-up volume was taken as an adjustable parameter, the retention of PS oligomer in organic mobile phase follows Martin’s rule (ln k ∝ DP) near perfectly. In addition, the enthalpy and entropy changes associated with the solute transfer, determined from the temperature dependence of the PS oligomer retention, also show excellent linear dependence on the degree of polymerization if the adjustable column hold-up volume was used. When we compare the retention behavior of PS and hydroxyl terminated PS, the repeating (styrene) unit exhibits the same enthalpy and entropy change while the end group shows the corresponding difference. All observations conform to Martin’s rule regardless of the columns used, but the physical nature of the adjustable column hold-up volume remains to be elucidated.</description><subject>Analytical chemistry</subject><subject>Chemistry</subject><subject>Chromatographic methods and physical methods associated with chromatography</subject><subject>Chromatography</subject><subject>Entropy</subject><subject>Exact sciences and technology</subject><subject>Other chromatographic methods</subject><subject>Polystyrene</subject><subject>Silica</subject><subject>Thermodynamics</subject><issn>0003-2700</issn><issn>1520-6882</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2009</creationdate><recordtype>article</recordtype><recordid>eNpl0MFqGzEQBmARGhLHzSEvEESghR62HUm7kvYYTBsHHBJCeyyLvDuyFXZXjrR78C2v0dfrk0Qlxob0NHP4mPn5Cblg8JUBZ99MXQJIzuwRmbCCQya15h_IBABExhXAKTmL8QmAMWDyhJyyshBKaZiQ33cmDK7_-_In0sexRWp9oHO3WmcPGNLemb5GunDPo2vobB18Zwa_Cmaz3tJHHLAfnO-pt_TBt9s4bAP2SO9bt_IdhviRHFvTRjzfzSn59eP7z9k8W9zf3M6uF5nJhRwyBCwKZqWpsSmWApYgSm4Z5KgbUBbyXNtGmsYuealZAUIoqRubqCgKXioxJZ_f7m6Cfx4xDlXnYo1ta3r0Y6ykyrXMJU_w6h188mPoU7aKM6VViiMT-vKG6uBjDGirTXCdCduKQfWv8GpfeLKXu4PjssPmIHcNJ_BpB0ysTWtDKtTFveMc0lfFD87U8RDq_4evpjqUNw</recordid><startdate>20090715</startdate><enddate>20090715</enddate><creator>Kim, Youngtak</creator><creator>Ahn, Seonyoung</creator><creator>Chang, Taihyun</creator><general>American Chemical Society</general><scope>IQODW</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7QF</scope><scope>7QO</scope><scope>7QQ</scope><scope>7SC</scope><scope>7SE</scope><scope>7SP</scope><scope>7SR</scope><scope>7TA</scope><scope>7TB</scope><scope>7TM</scope><scope>7U5</scope><scope>7U7</scope><scope>7U9</scope><scope>8BQ</scope><scope>8FD</scope><scope>C1K</scope><scope>F28</scope><scope>FR3</scope><scope>H8D</scope><scope>H8G</scope><scope>H94</scope><scope>JG9</scope><scope>JQ2</scope><scope>KR7</scope><scope>L7M</scope><scope>L~C</scope><scope>L~D</scope><scope>P64</scope><scope>7X8</scope></search><sort><creationdate>20090715</creationdate><title>Martin’s Rule for High-Performance Liquid Chromatography Retention of Polystyrene Oligomers</title><author>Kim, Youngtak ; Ahn, Seonyoung ; Chang, Taihyun</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-a436t-e0e551f6aced5b30b0392f104e8d07f0448fd6adfb29815033768df5b33552973</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2009</creationdate><topic>Analytical chemistry</topic><topic>Chemistry</topic><topic>Chromatographic methods and physical methods associated with chromatography</topic><topic>Chromatography</topic><topic>Entropy</topic><topic>Exact sciences and technology</topic><topic>Other chromatographic methods</topic><topic>Polystyrene</topic><topic>Silica</topic><topic>Thermodynamics</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Kim, Youngtak</creatorcontrib><creatorcontrib>Ahn, Seonyoung</creatorcontrib><creatorcontrib>Chang, Taihyun</creatorcontrib><collection>Pascal-Francis</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>Aluminium Industry Abstracts</collection><collection>Biotechnology Research Abstracts</collection><collection>Ceramic Abstracts</collection><collection>Computer and Information Systems Abstracts</collection><collection>Corrosion Abstracts</collection><collection>Electronics & Communications Abstracts</collection><collection>Engineered Materials Abstracts</collection><collection>Materials Business File</collection><collection>Mechanical & Transportation Engineering Abstracts</collection><collection>Nucleic Acids Abstracts</collection><collection>Solid State and Superconductivity Abstracts</collection><collection>Toxicology Abstracts</collection><collection>Virology and AIDS Abstracts</collection><collection>METADEX</collection><collection>Technology Research Database</collection><collection>Environmental Sciences and Pollution Management</collection><collection>ANTE: Abstracts in New Technology & Engineering</collection><collection>Engineering Research Database</collection><collection>Aerospace Database</collection><collection>Copper Technical Reference Library</collection><collection>AIDS and Cancer Research Abstracts</collection><collection>Materials Research Database</collection><collection>ProQuest Computer Science Collection</collection><collection>Civil Engineering Abstracts</collection><collection>Advanced Technologies Database with Aerospace</collection><collection>Computer and Information Systems Abstracts Academic</collection><collection>Computer and Information Systems Abstracts Professional</collection><collection>Biotechnology and BioEngineering Abstracts</collection><collection>MEDLINE - Academic</collection><jtitle>Analytical chemistry (Washington)</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Kim, Youngtak</au><au>Ahn, Seonyoung</au><au>Chang, Taihyun</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Martin’s Rule for High-Performance Liquid Chromatography Retention of Polystyrene Oligomers</atitle><jtitle>Analytical chemistry (Washington)</jtitle><addtitle>Anal. Chem</addtitle><date>2009-07-15</date><risdate>2009</risdate><volume>81</volume><issue>14</issue><spage>5902</spage><epage>5909</epage><pages>5902-5909</pages><issn>0003-2700</issn><eissn>1520-6882</eissn><coden>ANCHAM</coden><abstract>The liquid chromatographic retention of polystyrene (PS) oligomer was examined taking the column hold-up volume as an adjustable parameter based on the assumption that Martin’s rule is valid, i.e., ln k (retention factor) is proportional to the degree of polymerization (DP). In both bare silica and C18-bonded silica columns, thus determined column hold-up volume is systematically smaller than the elution volume of the injection solvent. When the column hold-up volume was taken as an adjustable parameter, the retention of PS oligomer in organic mobile phase follows Martin’s rule (ln k ∝ DP) near perfectly. In addition, the enthalpy and entropy changes associated with the solute transfer, determined from the temperature dependence of the PS oligomer retention, also show excellent linear dependence on the degree of polymerization if the adjustable column hold-up volume was used. When we compare the retention behavior of PS and hydroxyl terminated PS, the repeating (styrene) unit exhibits the same enthalpy and entropy change while the end group shows the corresponding difference. All observations conform to Martin’s rule regardless of the columns used, but the physical nature of the adjustable column hold-up volume remains to be elucidated.</abstract><cop>Washington, DC</cop><pub>American Chemical Society</pub><pmid>19537780</pmid><doi>10.1021/ac900621f</doi><tpages>8</tpages></addata></record> |
fulltext | fulltext |
identifier | ISSN: 0003-2700 |
ispartof | Analytical chemistry (Washington), 2009-07, Vol.81 (14), p.5902-5909 |
issn | 0003-2700 1520-6882 |
language | eng |
recordid | cdi_proquest_miscellaneous_67486462 |
source | ACS Publications |
subjects | Analytical chemistry Chemistry Chromatographic methods and physical methods associated with chromatography Chromatography Entropy Exact sciences and technology Other chromatographic methods Polystyrene Silica Thermodynamics |
title | Martin’s Rule for High-Performance Liquid Chromatography Retention of Polystyrene Oligomers |
url | https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-28T13%3A14%3A27IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Martin%E2%80%99s%20Rule%20for%20High-Performance%20Liquid%20Chromatography%20Retention%20of%20Polystyrene%20Oligomers&rft.jtitle=Analytical%20chemistry%20(Washington)&rft.au=Kim,%20Youngtak&rft.date=2009-07-15&rft.volume=81&rft.issue=14&rft.spage=5902&rft.epage=5909&rft.pages=5902-5909&rft.issn=0003-2700&rft.eissn=1520-6882&rft.coden=ANCHAM&rft_id=info:doi/10.1021/ac900621f&rft_dat=%3Cproquest_cross%3E1793139871%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=217874366&rft_id=info:pmid/19537780&rfr_iscdi=true |