SPECT/CT Fusion Imaging in Radionuclide Cisternography for Localization of Liquor Leakage Sites
ABSTRACT OBJECTIVE We report our experience with radionuclide cisternography (RC) with 111In‐diethylenthriamine penta‐acetic acid (DTPA) using a computed tomography (CT) mounted hybrid gamma camera in patients with cerebrospinal liquor leakage. METHODS SPECT/CT fusion imaging was performed in case...
Gespeichert in:
Veröffentlicht in: | Journal of neuroimaging 2009-07, Vol.19 (3), p.227-234 |
---|---|
Hauptverfasser: | , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | ABSTRACT
OBJECTIVE
We report our experience with radionuclide cisternography (RC) with 111In‐diethylenthriamine penta‐acetic acid (DTPA) using a computed tomography (CT) mounted hybrid gamma camera in patients with cerebrospinal liquor leakage.
METHODS
SPECT/CT fusion imaging was performed in case of suspected tracer egress on planar or SPECT images in order to obtain a detailed correlation of the leakage site.
RESULTS
Leakage was detected in all 3 patients. Using SPECT/CT, the extradural tracer accumulation could be correlated to an anatomical structure, which had not been possible by evaluation of the scintigraphic studies alone.
CONCLUSION
Introducing SPECT/CT for radionuclide cisternography seems to be a valuable tool to facilitate the diagnosis of cerebrospinal liquor leakage. |
---|---|
ISSN: | 1051-2284 1552-6569 |
DOI: | 10.1111/j.1552-6569.2008.00270.x |