The Relationship of Audiometric Thresholds Elicited with Pulsed, Warbled, and Pulsed-Warbled Tones in Adults with Normal Hearing

OBJECTIVE:American Speech-Language-Hearing Association (ASHA) guidelines allow pulsed and warbled tones in measuring audiometric thresholds and include test frequencies of 3000 and 6000 Hz. However, no research has examined the relationship between thresholds obtained with these stimuli at these fre...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Ear and hearing 2009-08, Vol.30 (4), p.485-487
Hauptverfasser: Franklin, Clifford, Johnson, Kasey, Smith-Olinde, Laura, Nicholson, Nannette
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:OBJECTIVE:American Speech-Language-Hearing Association (ASHA) guidelines allow pulsed and warbled tones in measuring audiometric thresholds and include test frequencies of 3000 and 6000 Hz. However, no research has examined the relationship between thresholds obtained with these stimuli at these frequencies. This study investigated the relationship between thresholds obtained with pulsed, warbled, and pulsed-warbled tones. DESIGN:Thresholds from 25 listeners were obtained using pulsed, warbled, and pulsed-warbled tones at test frequencies recommended by ASHA. RESULTS:Thresholds elicited with pulsed, warbled, and pulsed-warbled tones did not significantly differ. CONCLUSIONS:Findings support using pulsed, warbled, and pulsed-warbled tones for threshold measurements at the frequencies recommended by ASHA.
ISSN:0196-0202
1538-4667
DOI:10.1097/AUD.0b013e3181a16366