Breast MRI: Are T2 IR sequences useful in the evaluation of breast lesions?

Abstract Aim To evaluate the potential role of signal intensities calculated in T2 images as an adjunctive parameter in the analysis of mass-like enhancements classified as BIRADS (Breast Imaging Reporting and Data System) assessment categories 2, 3, 4 or 5 with the standard T1 criteria. Materials a...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:European journal of radiology 2009-07, Vol.71 (1), p.96-101
Hauptverfasser: Ballesio, Laura, Savelli, Sara, Angeletti, Marco, Porfiri, Lucio Maria, D’Ambrosio, Ilaria, Maggi, Claudia, Castro, Elisabetta Di, Bennati, Paolo, Fanelli, Gloria Pasqua, Vestri, Anna Rita, Manganaro, Lucia
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Abstract Aim To evaluate the potential role of signal intensities calculated in T2 images as an adjunctive parameter in the analysis of mass-like enhancements classified as BIRADS (Breast Imaging Reporting and Data System) assessment categories 2, 3, 4 or 5 with the standard T1 criteria. Materials and methods After a retrospective review of 338-breast Magnetic Resonance Imaging (MRI) performed for the evaluation of a suspicious lesion we selected a group of 65 mass-like enhancements ranging from 5 to 20 mm, classified as BIRADS assessment categories 2, 3, 4 or 5, histologically proved. In all cases we calculated the ratio between the signal intensity (SI) of the nodule and the pectoralis major muscle (LMSIR, lesion to muscle signal intensity ratio) with a multiROIs (region of interest) analysis on T2 images. A ROC analysis was performed to test the ability of the two diagnostic parameters separately considered (BIRADS and LMSIR) and combined in a new mono-dimensional variable obtained by a computerized discriminant function. Results Histological examination assessed 34 malignant lesions (52.3%) and 31 benign lesions (47.7%). The evaluation of ROC curves gave the following results: BIRADS area under the curve (AUC) 0.913, S.E. 0.0368, LMSIR AUC 0.854, S.E. 0.0487, combined BIRADS–LMSIR AUC 0.965, S.E. 0.0191 with a definitive increase in the AUC between the overall ROC area and those of the two diagnostic modalities separately considered. Discussion T2-weighted SI assessment with LMSIR measurement improves the diagnostic information content of standard breast MRI and can be considered a promising potential tool in the differential diagnosis of mass-like enhancements judged as borderline lesions (BIRADS 3 and 4).
ISSN:0720-048X
1872-7727
DOI:10.1016/j.ejrad.2008.03.025