Optimisation and analysis of microreactor designs for microfluidic gradient generation using a purpose built optical detection system for entire chip imaging

This paper presents and fully characterises a novel simplification approach for the development of microsystem based concentration gradient generators with significantly reduced microfluidic networks. Three microreactors are presented; a pair of two-inlet six-outlet (2-6) networks and a two-inlet el...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Lab on a chip 2009-01, Vol.9 (13), p.1882-1889
Hauptverfasser: Abdulla Yusuf, Hayat, Baldock, Sara J, Barber, Robert W, Fielden, Peter R, Goddard, Nick J, Mohr, Stephan, Treves Brown, Bernard J
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 1889
container_issue 13
container_start_page 1882
container_title Lab on a chip
container_volume 9
creator Abdulla Yusuf, Hayat
Baldock, Sara J
Barber, Robert W
Fielden, Peter R
Goddard, Nick J
Mohr, Stephan
Treves Brown, Bernard J
description This paper presents and fully characterises a novel simplification approach for the development of microsystem based concentration gradient generators with significantly reduced microfluidic networks. Three microreactors are presented; a pair of two-inlet six-outlet (2-6) networks and a two-inlet eleven-outlet (2-11) network design. The mathematical approach has been validated experimentally using a purpose built optical detection system. The experimental results are shown to be in very good agreement with the theoretical predictions from the model. The developed networks are proven to deliver precise linear concentration gradients (R(2) = 0.9973 and 0.9991 for the (2-6) designs) and the simplified networks are shown to provide enhanced performance over conventional designs, overcoming some of the practical issues associated with traditional networks. The optical measurements were precise enough to validate the linearity in each level of the conventional (2-6) networks (R(2) ranged from 0.9999 to 0.9973) compared to R(2) = 1 for the theoretical model. CFD results show that there is an effective upper limit on the operating flow rate. The new simplified (2-11) design was able to maintain a linear outlet profile up to 0.8 microl/s per inlet (R(2) = 0.9992). The proposed approach is widely applicable for the production of linear and arbitrary concentration profiles, with the potential for high throughput applications that span a wide range of chemical and biological studies.
doi_str_mv 10.1039/b823101j
format Article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_67388098</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>67388098</sourcerecordid><originalsourceid>FETCH-LOGICAL-c369t-f34c81f7b35744412afced4c1fddb8ed075c7b23efe8df1e9a8e607472178ca3</originalsourceid><addsrcrecordid>eNqFkU1LAzEQhoMotlbBXyA5iZfVZLO7yR6l-AWFXnpfsslkTdkvk-yhP8b_amyrHj2EGZiHJ8y8CF1Tck8JKx9qkTJK6PYEzWnGWUKoKE9_-5LP0IX3W0JonhXiHM1ombO0LNgcfa7HYDvrZbBDj2Wv45PtzluPB4M7q9zgQKowOKzB26b32MR-PzDtZLVVuHFSW-gDbqAHdzBN3vYNlnic3Dh4wPVk24CH-JmSbVQFUHvO73yAbu-MBusAq3c7YtvJJgou0ZmRrYerY12gzfPTZvmarNYvb8vHVaJYUYbEsEwJanjNcp5lGU2lUaAzRY3WtQBNeK54nTIwILShUEoBBeEZTykXSrIFuj1oRzd8TOBDFS-ioG1lD8Pkq4IzIUgp_gVZTtIiJ0UE7w5gPJP3Dkw1uriT21WUVN-RVT-RRfTm6JzqDvQfeMyIfQFtMpY9</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>35026506</pqid></control><display><type>article</type><title>Optimisation and analysis of microreactor designs for microfluidic gradient generation using a purpose built optical detection system for entire chip imaging</title><source>MEDLINE</source><source>Royal Society Of Chemistry Journals 2008-</source><source>Alma/SFX Local Collection</source><creator>Abdulla Yusuf, Hayat ; Baldock, Sara J ; Barber, Robert W ; Fielden, Peter R ; Goddard, Nick J ; Mohr, Stephan ; Treves Brown, Bernard J</creator><creatorcontrib>Abdulla Yusuf, Hayat ; Baldock, Sara J ; Barber, Robert W ; Fielden, Peter R ; Goddard, Nick J ; Mohr, Stephan ; Treves Brown, Bernard J</creatorcontrib><description>This paper presents and fully characterises a novel simplification approach for the development of microsystem based concentration gradient generators with significantly reduced microfluidic networks. Three microreactors are presented; a pair of two-inlet six-outlet (2-6) networks and a two-inlet eleven-outlet (2-11) network design. The mathematical approach has been validated experimentally using a purpose built optical detection system. The experimental results are shown to be in very good agreement with the theoretical predictions from the model. The developed networks are proven to deliver precise linear concentration gradients (R(2) = 0.9973 and 0.9991 for the (2-6) designs) and the simplified networks are shown to provide enhanced performance over conventional designs, overcoming some of the practical issues associated with traditional networks. The optical measurements were precise enough to validate the linearity in each level of the conventional (2-6) networks (R(2) ranged from 0.9999 to 0.9973) compared to R(2) = 1 for the theoretical model. CFD results show that there is an effective upper limit on the operating flow rate. The new simplified (2-11) design was able to maintain a linear outlet profile up to 0.8 microl/s per inlet (R(2) = 0.9992). The proposed approach is widely applicable for the production of linear and arbitrary concentration profiles, with the potential for high throughput applications that span a wide range of chemical and biological studies.</description><identifier>ISSN: 1473-0197</identifier><identifier>EISSN: 1473-0189</identifier><identifier>DOI: 10.1039/b823101j</identifier><identifier>PMID: 19532963</identifier><language>eng</language><publisher>England</publisher><subject>Computer Simulation ; Equipment Design ; Microfluidic Analytical Techniques - instrumentation ; Models, Theoretical ; Optical Devices ; Solutions - chemistry</subject><ispartof>Lab on a chip, 2009-01, Vol.9 (13), p.1882-1889</ispartof><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c369t-f34c81f7b35744412afced4c1fddb8ed075c7b23efe8df1e9a8e607472178ca3</citedby><cites>FETCH-LOGICAL-c369t-f34c81f7b35744412afced4c1fddb8ed075c7b23efe8df1e9a8e607472178ca3</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,780,784,27924,27925</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/19532963$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Abdulla Yusuf, Hayat</creatorcontrib><creatorcontrib>Baldock, Sara J</creatorcontrib><creatorcontrib>Barber, Robert W</creatorcontrib><creatorcontrib>Fielden, Peter R</creatorcontrib><creatorcontrib>Goddard, Nick J</creatorcontrib><creatorcontrib>Mohr, Stephan</creatorcontrib><creatorcontrib>Treves Brown, Bernard J</creatorcontrib><title>Optimisation and analysis of microreactor designs for microfluidic gradient generation using a purpose built optical detection system for entire chip imaging</title><title>Lab on a chip</title><addtitle>Lab Chip</addtitle><description>This paper presents and fully characterises a novel simplification approach for the development of microsystem based concentration gradient generators with significantly reduced microfluidic networks. Three microreactors are presented; a pair of two-inlet six-outlet (2-6) networks and a two-inlet eleven-outlet (2-11) network design. The mathematical approach has been validated experimentally using a purpose built optical detection system. The experimental results are shown to be in very good agreement with the theoretical predictions from the model. The developed networks are proven to deliver precise linear concentration gradients (R(2) = 0.9973 and 0.9991 for the (2-6) designs) and the simplified networks are shown to provide enhanced performance over conventional designs, overcoming some of the practical issues associated with traditional networks. The optical measurements were precise enough to validate the linearity in each level of the conventional (2-6) networks (R(2) ranged from 0.9999 to 0.9973) compared to R(2) = 1 for the theoretical model. CFD results show that there is an effective upper limit on the operating flow rate. The new simplified (2-11) design was able to maintain a linear outlet profile up to 0.8 microl/s per inlet (R(2) = 0.9992). The proposed approach is widely applicable for the production of linear and arbitrary concentration profiles, with the potential for high throughput applications that span a wide range of chemical and biological studies.</description><subject>Computer Simulation</subject><subject>Equipment Design</subject><subject>Microfluidic Analytical Techniques - instrumentation</subject><subject>Models, Theoretical</subject><subject>Optical Devices</subject><subject>Solutions - chemistry</subject><issn>1473-0197</issn><issn>1473-0189</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2009</creationdate><recordtype>article</recordtype><sourceid>EIF</sourceid><recordid>eNqFkU1LAzEQhoMotlbBXyA5iZfVZLO7yR6l-AWFXnpfsslkTdkvk-yhP8b_amyrHj2EGZiHJ8y8CF1Tck8JKx9qkTJK6PYEzWnGWUKoKE9_-5LP0IX3W0JonhXiHM1ombO0LNgcfa7HYDvrZbBDj2Wv45PtzluPB4M7q9zgQKowOKzB26b32MR-PzDtZLVVuHFSW-gDbqAHdzBN3vYNlnic3Dh4wPVk24CH-JmSbVQFUHvO73yAbu-MBusAq3c7YtvJJgou0ZmRrYerY12gzfPTZvmarNYvb8vHVaJYUYbEsEwJanjNcp5lGU2lUaAzRY3WtQBNeK54nTIwILShUEoBBeEZTykXSrIFuj1oRzd8TOBDFS-ioG1lD8Pkq4IzIUgp_gVZTtIiJ0UE7w5gPJP3Dkw1uriT21WUVN-RVT-RRfTm6JzqDvQfeMyIfQFtMpY9</recordid><startdate>20090101</startdate><enddate>20090101</enddate><creator>Abdulla Yusuf, Hayat</creator><creator>Baldock, Sara J</creator><creator>Barber, Robert W</creator><creator>Fielden, Peter R</creator><creator>Goddard, Nick J</creator><creator>Mohr, Stephan</creator><creator>Treves Brown, Bernard J</creator><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7SP</scope><scope>7TB</scope><scope>7U5</scope><scope>8FD</scope><scope>FR3</scope><scope>L7M</scope><scope>7X8</scope></search><sort><creationdate>20090101</creationdate><title>Optimisation and analysis of microreactor designs for microfluidic gradient generation using a purpose built optical detection system for entire chip imaging</title><author>Abdulla Yusuf, Hayat ; Baldock, Sara J ; Barber, Robert W ; Fielden, Peter R ; Goddard, Nick J ; Mohr, Stephan ; Treves Brown, Bernard J</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c369t-f34c81f7b35744412afced4c1fddb8ed075c7b23efe8df1e9a8e607472178ca3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2009</creationdate><topic>Computer Simulation</topic><topic>Equipment Design</topic><topic>Microfluidic Analytical Techniques - instrumentation</topic><topic>Models, Theoretical</topic><topic>Optical Devices</topic><topic>Solutions - chemistry</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Abdulla Yusuf, Hayat</creatorcontrib><creatorcontrib>Baldock, Sara J</creatorcontrib><creatorcontrib>Barber, Robert W</creatorcontrib><creatorcontrib>Fielden, Peter R</creatorcontrib><creatorcontrib>Goddard, Nick J</creatorcontrib><creatorcontrib>Mohr, Stephan</creatorcontrib><creatorcontrib>Treves Brown, Bernard J</creatorcontrib><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>Electronics &amp; Communications Abstracts</collection><collection>Mechanical &amp; Transportation Engineering Abstracts</collection><collection>Solid State and Superconductivity Abstracts</collection><collection>Technology Research Database</collection><collection>Engineering Research Database</collection><collection>Advanced Technologies Database with Aerospace</collection><collection>MEDLINE - Academic</collection><jtitle>Lab on a chip</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Abdulla Yusuf, Hayat</au><au>Baldock, Sara J</au><au>Barber, Robert W</au><au>Fielden, Peter R</au><au>Goddard, Nick J</au><au>Mohr, Stephan</au><au>Treves Brown, Bernard J</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Optimisation and analysis of microreactor designs for microfluidic gradient generation using a purpose built optical detection system for entire chip imaging</atitle><jtitle>Lab on a chip</jtitle><addtitle>Lab Chip</addtitle><date>2009-01-01</date><risdate>2009</risdate><volume>9</volume><issue>13</issue><spage>1882</spage><epage>1889</epage><pages>1882-1889</pages><issn>1473-0197</issn><eissn>1473-0189</eissn><abstract>This paper presents and fully characterises a novel simplification approach for the development of microsystem based concentration gradient generators with significantly reduced microfluidic networks. Three microreactors are presented; a pair of two-inlet six-outlet (2-6) networks and a two-inlet eleven-outlet (2-11) network design. The mathematical approach has been validated experimentally using a purpose built optical detection system. The experimental results are shown to be in very good agreement with the theoretical predictions from the model. The developed networks are proven to deliver precise linear concentration gradients (R(2) = 0.9973 and 0.9991 for the (2-6) designs) and the simplified networks are shown to provide enhanced performance over conventional designs, overcoming some of the practical issues associated with traditional networks. The optical measurements were precise enough to validate the linearity in each level of the conventional (2-6) networks (R(2) ranged from 0.9999 to 0.9973) compared to R(2) = 1 for the theoretical model. CFD results show that there is an effective upper limit on the operating flow rate. The new simplified (2-11) design was able to maintain a linear outlet profile up to 0.8 microl/s per inlet (R(2) = 0.9992). The proposed approach is widely applicable for the production of linear and arbitrary concentration profiles, with the potential for high throughput applications that span a wide range of chemical and biological studies.</abstract><cop>England</cop><pmid>19532963</pmid><doi>10.1039/b823101j</doi><tpages>8</tpages></addata></record>
fulltext fulltext
identifier ISSN: 1473-0197
ispartof Lab on a chip, 2009-01, Vol.9 (13), p.1882-1889
issn 1473-0197
1473-0189
language eng
recordid cdi_proquest_miscellaneous_67388098
source MEDLINE; Royal Society Of Chemistry Journals 2008-; Alma/SFX Local Collection
subjects Computer Simulation
Equipment Design
Microfluidic Analytical Techniques - instrumentation
Models, Theoretical
Optical Devices
Solutions - chemistry
title Optimisation and analysis of microreactor designs for microfluidic gradient generation using a purpose built optical detection system for entire chip imaging
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-05T10%3A30%3A54IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Optimisation%20and%20analysis%20of%20microreactor%20designs%20for%20microfluidic%20gradient%20generation%20using%20a%20purpose%20built%20optical%20detection%20system%20for%20entire%20chip%20imaging&rft.jtitle=Lab%20on%20a%20chip&rft.au=Abdulla%20Yusuf,%20Hayat&rft.date=2009-01-01&rft.volume=9&rft.issue=13&rft.spage=1882&rft.epage=1889&rft.pages=1882-1889&rft.issn=1473-0197&rft.eissn=1473-0189&rft_id=info:doi/10.1039/b823101j&rft_dat=%3Cproquest_cross%3E67388098%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=35026506&rft_id=info:pmid/19532963&rfr_iscdi=true