Another use of the Foley catheter: retraction for operations on the floor of mouth and ventral aspect of the tongue

A Foley catheter that is passed through the nose and sutured to the tip of the tongue can be used to facilitate retraction for operations on lesions on the ventral aspect of the tongue and the floor of the mouth. It provides excellent access and is simple, inexpensive, atraumatic, minimises frustrat...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:British journal of oral & maxillofacial surgery 2005-02, Vol.43 (1), p.83-84
Hauptverfasser: Ramchandani, P.L., Sabesan, T., Peters, W.J.N., Wilson, A.W.
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 84
container_issue 1
container_start_page 83
container_title British journal of oral & maxillofacial surgery
container_volume 43
creator Ramchandani, P.L.
Sabesan, T.
Peters, W.J.N.
Wilson, A.W.
description A Foley catheter that is passed through the nose and sutured to the tip of the tongue can be used to facilitate retraction for operations on lesions on the ventral aspect of the tongue and the floor of the mouth. It provides excellent access and is simple, inexpensive, atraumatic, minimises frustration, reduces the operating time, and eliminates some of the difficulties associated with the use of metal retractors.
doi_str_mv 10.1016/j.bjoms.2004.09.007
format Article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_67342809</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><els_id>S0266435604001809</els_id><sourcerecordid>67342809</sourcerecordid><originalsourceid>FETCH-LOGICAL-c337t-1780c836a2494d9131ed08d780ce1170740ec61a37bf566ca1d65fde0cd901653</originalsourceid><addsrcrecordid>eNp9kMFq3DAQhkVISbbbPEGh6JLc7I4sWbYLPYSlaQuBXNKz0EqjxIttbSQ5kLePnN2QW08a_Xz_MHyEfGVQMmDy-67c7vwYywpAlNCVAM0JWbGaVwXrBJySFVRSFoLX8px8jnEHAHXF6jNyzmpZQdOKFYnXk0-PGOgckXpH80xv_IAv1Og8Jww_aMAUtEm9n6jzgfo9Br38Is3JUnCDX3JHRz-nR6onS59xyqWB6rhHk943Jz89zPiFfHJ6iHhxfNfk382v-82f4vbu99_N9W1hOG9SwZoWTMulrkQnbMc4QwutXVJkrIFGABrJNG-2rpbSaGZl7SyCsV32U_M1uTrs3Qf_NGNMauyjwWHQE_o5KtlwUbXQZZAfQBN8jAGd2od-1OFFMVCLa7VTb67V4lpBp7Lr3Pp2XD9vR7QfnaPcDFweAR2NHlzQk-njBycFiFZUmft54DDLeO4xqGh6nAzaPmR5yvr-v4e8Aioknlg</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>67342809</pqid></control><display><type>article</type><title>Another use of the Foley catheter: retraction for operations on the floor of mouth and ventral aspect of the tongue</title><source>MEDLINE</source><source>Elsevier ScienceDirect Journals</source><creator>Ramchandani, P.L. ; Sabesan, T. ; Peters, W.J.N. ; Wilson, A.W.</creator><creatorcontrib>Ramchandani, P.L. ; Sabesan, T. ; Peters, W.J.N. ; Wilson, A.W.</creatorcontrib><description>A Foley catheter that is passed through the nose and sutured to the tip of the tongue can be used to facilitate retraction for operations on lesions on the ventral aspect of the tongue and the floor of the mouth. It provides excellent access and is simple, inexpensive, atraumatic, minimises frustration, reduces the operating time, and eliminates some of the difficulties associated with the use of metal retractors.</description><identifier>ISSN: 0266-4356</identifier><identifier>EISSN: 1532-1940</identifier><identifier>DOI: 10.1016/j.bjoms.2004.09.007</identifier><identifier>PMID: 15620784</identifier><identifier>CODEN: BJOSEY</identifier><language>eng</language><publisher>Londonc: Elsevier Ltd</publisher><subject>Biological and medical sciences ; Catheterization - instrumentation ; Dentistry ; Foley catheter ; Humans ; Medical sciences ; Mouth floor ; Mouth Floor - surgery ; Oral Surgical Procedures - instrumentation ; Otorhinolaryngology. Stomatology ; Surgical instruments ; Tongue ; Tongue - surgery</subject><ispartof>British journal of oral &amp; maxillofacial surgery, 2005-02, Vol.43 (1), p.83-84</ispartof><rights>2004 The British Association of Oral and Maxillofacial Surgeons</rights><rights>2005 INIST-CNRS</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><cites>FETCH-LOGICAL-c337t-1780c836a2494d9131ed08d780ce1170740ec61a37bf566ca1d65fde0cd901653</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://www.sciencedirect.com/science/article/pii/S0266435604001809$$EHTML$$P50$$Gelsevier$$H</linktohtml><link.rule.ids>314,776,780,3537,27901,27902,65306</link.rule.ids><backlink>$$Uhttp://pascal-francis.inist.fr/vibad/index.php?action=getRecordDetail&amp;idt=16404842$$DView record in Pascal Francis$$Hfree_for_read</backlink><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/15620784$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Ramchandani, P.L.</creatorcontrib><creatorcontrib>Sabesan, T.</creatorcontrib><creatorcontrib>Peters, W.J.N.</creatorcontrib><creatorcontrib>Wilson, A.W.</creatorcontrib><title>Another use of the Foley catheter: retraction for operations on the floor of mouth and ventral aspect of the tongue</title><title>British journal of oral &amp; maxillofacial surgery</title><addtitle>Br J Oral Maxillofac Surg</addtitle><description>A Foley catheter that is passed through the nose and sutured to the tip of the tongue can be used to facilitate retraction for operations on lesions on the ventral aspect of the tongue and the floor of the mouth. It provides excellent access and is simple, inexpensive, atraumatic, minimises frustration, reduces the operating time, and eliminates some of the difficulties associated with the use of metal retractors.</description><subject>Biological and medical sciences</subject><subject>Catheterization - instrumentation</subject><subject>Dentistry</subject><subject>Foley catheter</subject><subject>Humans</subject><subject>Medical sciences</subject><subject>Mouth floor</subject><subject>Mouth Floor - surgery</subject><subject>Oral Surgical Procedures - instrumentation</subject><subject>Otorhinolaryngology. Stomatology</subject><subject>Surgical instruments</subject><subject>Tongue</subject><subject>Tongue - surgery</subject><issn>0266-4356</issn><issn>1532-1940</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2005</creationdate><recordtype>article</recordtype><sourceid>EIF</sourceid><recordid>eNp9kMFq3DAQhkVISbbbPEGh6JLc7I4sWbYLPYSlaQuBXNKz0EqjxIttbSQ5kLePnN2QW08a_Xz_MHyEfGVQMmDy-67c7vwYywpAlNCVAM0JWbGaVwXrBJySFVRSFoLX8px8jnEHAHXF6jNyzmpZQdOKFYnXk0-PGOgckXpH80xv_IAv1Og8Jww_aMAUtEm9n6jzgfo9Br38Is3JUnCDX3JHRz-nR6onS59xyqWB6rhHk943Jz89zPiFfHJ6iHhxfNfk382v-82f4vbu99_N9W1hOG9SwZoWTMulrkQnbMc4QwutXVJkrIFGABrJNG-2rpbSaGZl7SyCsV32U_M1uTrs3Qf_NGNMauyjwWHQE_o5KtlwUbXQZZAfQBN8jAGd2od-1OFFMVCLa7VTb67V4lpBp7Lr3Pp2XD9vR7QfnaPcDFweAR2NHlzQk-njBycFiFZUmft54DDLeO4xqGh6nAzaPmR5yvr-v4e8Aioknlg</recordid><startdate>20050201</startdate><enddate>20050201</enddate><creator>Ramchandani, P.L.</creator><creator>Sabesan, T.</creator><creator>Peters, W.J.N.</creator><creator>Wilson, A.W.</creator><general>Elsevier Ltd</general><general>Elsevier</general><scope>IQODW</scope><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope></search><sort><creationdate>20050201</creationdate><title>Another use of the Foley catheter: retraction for operations on the floor of mouth and ventral aspect of the tongue</title><author>Ramchandani, P.L. ; Sabesan, T. ; Peters, W.J.N. ; Wilson, A.W.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c337t-1780c836a2494d9131ed08d780ce1170740ec61a37bf566ca1d65fde0cd901653</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2005</creationdate><topic>Biological and medical sciences</topic><topic>Catheterization - instrumentation</topic><topic>Dentistry</topic><topic>Foley catheter</topic><topic>Humans</topic><topic>Medical sciences</topic><topic>Mouth floor</topic><topic>Mouth Floor - surgery</topic><topic>Oral Surgical Procedures - instrumentation</topic><topic>Otorhinolaryngology. Stomatology</topic><topic>Surgical instruments</topic><topic>Tongue</topic><topic>Tongue - surgery</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Ramchandani, P.L.</creatorcontrib><creatorcontrib>Sabesan, T.</creatorcontrib><creatorcontrib>Peters, W.J.N.</creatorcontrib><creatorcontrib>Wilson, A.W.</creatorcontrib><collection>Pascal-Francis</collection><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><jtitle>British journal of oral &amp; maxillofacial surgery</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Ramchandani, P.L.</au><au>Sabesan, T.</au><au>Peters, W.J.N.</au><au>Wilson, A.W.</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Another use of the Foley catheter: retraction for operations on the floor of mouth and ventral aspect of the tongue</atitle><jtitle>British journal of oral &amp; maxillofacial surgery</jtitle><addtitle>Br J Oral Maxillofac Surg</addtitle><date>2005-02-01</date><risdate>2005</risdate><volume>43</volume><issue>1</issue><spage>83</spage><epage>84</epage><pages>83-84</pages><issn>0266-4356</issn><eissn>1532-1940</eissn><coden>BJOSEY</coden><abstract>A Foley catheter that is passed through the nose and sutured to the tip of the tongue can be used to facilitate retraction for operations on lesions on the ventral aspect of the tongue and the floor of the mouth. It provides excellent access and is simple, inexpensive, atraumatic, minimises frustration, reduces the operating time, and eliminates some of the difficulties associated with the use of metal retractors.</abstract><cop>Londonc</cop><pub>Elsevier Ltd</pub><pmid>15620784</pmid><doi>10.1016/j.bjoms.2004.09.007</doi><tpages>2</tpages></addata></record>
fulltext fulltext
identifier ISSN: 0266-4356
ispartof British journal of oral & maxillofacial surgery, 2005-02, Vol.43 (1), p.83-84
issn 0266-4356
1532-1940
language eng
recordid cdi_proquest_miscellaneous_67342809
source MEDLINE; Elsevier ScienceDirect Journals
subjects Biological and medical sciences
Catheterization - instrumentation
Dentistry
Foley catheter
Humans
Medical sciences
Mouth floor
Mouth Floor - surgery
Oral Surgical Procedures - instrumentation
Otorhinolaryngology. Stomatology
Surgical instruments
Tongue
Tongue - surgery
title Another use of the Foley catheter: retraction for operations on the floor of mouth and ventral aspect of the tongue
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-02-03T18%3A27%3A38IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Another%20use%20of%20the%20Foley%20catheter:%20retraction%20for%20operations%20on%20the%20floor%20of%20mouth%20and%20ventral%20aspect%20of%20the%20tongue&rft.jtitle=British%20journal%20of%20oral%20&%20maxillofacial%20surgery&rft.au=Ramchandani,%20P.L.&rft.date=2005-02-01&rft.volume=43&rft.issue=1&rft.spage=83&rft.epage=84&rft.pages=83-84&rft.issn=0266-4356&rft.eissn=1532-1940&rft.coden=BJOSEY&rft_id=info:doi/10.1016/j.bjoms.2004.09.007&rft_dat=%3Cproquest_cross%3E67342809%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=67342809&rft_id=info:pmid/15620784&rft_els_id=S0266435604001809&rfr_iscdi=true