Spiral imaging artifact reduction: A comparison of two k-trajectory measurement methods

Purpose To compare an external sensor‐based k‐space calibration technique with a routine precalibration method for quantification of method accuracy and reduction of spiral imaging artifacts to obtain improved image quality. Materials and Methods Recently, magnetic field monitoring (MFM) has been in...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Journal of magnetic resonance imaging 2009-06, Vol.29 (6), p.1485-1492
Hauptverfasser: Lechner, Silke M., Sipilä, Pekka T., Wiesinger, Florian, Kerr, Adam B., Vogel, Mika W.
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 1492
container_issue 6
container_start_page 1485
container_title Journal of magnetic resonance imaging
container_volume 29
creator Lechner, Silke M.
Sipilä, Pekka T.
Wiesinger, Florian
Kerr, Adam B.
Vogel, Mika W.
description Purpose To compare an external sensor‐based k‐space calibration technique with a routine precalibration method for quantification of method accuracy and reduction of spiral imaging artifacts to obtain improved image quality. Materials and Methods Recently, magnetic field monitoring (MFM) has been introduced as a new calibration technique of gradient field‐related imperfections. External sensors are placed near the observed object to measure magnetic field variations during image acquisition. The measured field data are used to determine the actual k‐space trajectory and for image reconstruction to reduce artifacts. In the past, precalibration techniques have been proposed where the k‐space trajectory is measured by means of special calibration sequences directly in the object of interest. In this study, MFM is introduced as an effective correction technique for spiral imaging. On the basis of a comparison, whether MFM is as viable as the chosen reference method presented by Duyn et al (J Magn Reson [1998] 132:150–153) is analyzed in terms of detecting imperfections of spatial encoding gradients in order to correct for these in image reconstruction. As this technique is used as a reference method, it is given the acronym Duyn calibration technique (DCT). MFM and DCT are compared and timing delays, k‐space offsets, eddy current effects, k‐trajectory error propagation, image distortions, and signal‐to‐noise ratio were determined for different spiral sequences in two different phantoms. Results Both techniques effectively detect k‐space offsets and k‐trajectory error propagation and correct for general error sources like timing delays. In object border areas, artifacts such as deformations and blurring were dramatically reduced. Within all tested categories, MFM performed as well as DCT. In terms of k‐trajectory error propagation and image distortion quantification, MFM was more accurate. Conclusion We introduce MFM as an effective and accurate correction technique for spiral imaging, where a comparison of MFM and DCT has shown that both techniques are accurate correction techniques for spiral imaging. J. Magn. Reson. Imaging 2009;29:1485–1492. © 2009 Wiley‐Liss, Inc.
doi_str_mv 10.1002/jmri.21782
format Article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_67323067</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>67323067</sourcerecordid><originalsourceid>FETCH-LOGICAL-c4012-8d558ed7399cf63034351cdd8c26ef317e9775bc045c5359e634ec239ac9449a3</originalsourceid><addsrcrecordid>eNp9kE9P3DAQxa2KqsC2l34A5BMHpFD_jePe0AooCFotUCH1YhlnQr0k8WI7gv32zbIL3HqZeYffe5p5CH2l5JASwr7Nu-gPGVUV-4B2qGSsYLIqt0ZNJC9oRdQ22k1pTgjRWshPaJtqoZhg5Q66vV74aFvsO3vv-3tsY_aNdRlHqAeXfei_4yPsQrew0afQ49Dg_BTwQ5GjnYPLIS5xBzYNETro86jz31Cnz-hjY9sEXzZ7gn6fHN9MfxQXv07PpkcXhROEsqKqpaygVlxr15SccMEldXVdOVZCw6kCrZS8c0RIJ7nUUHIBjnFtnRZCWz5B--vcRQyPA6RsOp8ctK3tIQzJlIozTsY5QQdr0MWQUoTGLOL4dFwaSsyqRrOq0bzUOMJ7m9ThroP6Hd30NgJ0DTz5Fpb_iTLnl1dnr6HF2uNThuc3j40PqyuVNLc_Tw25-TOb8UtiZvwf7f2M4w</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>67323067</pqid></control><display><type>article</type><title>Spiral imaging artifact reduction: A comparison of two k-trajectory measurement methods</title><source>MEDLINE</source><source>Wiley Online Library Free Content</source><source>Access via Wiley Online Library</source><creator>Lechner, Silke M. ; Sipilä, Pekka T. ; Wiesinger, Florian ; Kerr, Adam B. ; Vogel, Mika W.</creator><creatorcontrib>Lechner, Silke M. ; Sipilä, Pekka T. ; Wiesinger, Florian ; Kerr, Adam B. ; Vogel, Mika W.</creatorcontrib><description>Purpose To compare an external sensor‐based k‐space calibration technique with a routine precalibration method for quantification of method accuracy and reduction of spiral imaging artifacts to obtain improved image quality. Materials and Methods Recently, magnetic field monitoring (MFM) has been introduced as a new calibration technique of gradient field‐related imperfections. External sensors are placed near the observed object to measure magnetic field variations during image acquisition. The measured field data are used to determine the actual k‐space trajectory and for image reconstruction to reduce artifacts. In the past, precalibration techniques have been proposed where the k‐space trajectory is measured by means of special calibration sequences directly in the object of interest. In this study, MFM is introduced as an effective correction technique for spiral imaging. On the basis of a comparison, whether MFM is as viable as the chosen reference method presented by Duyn et al (J Magn Reson [1998] 132:150–153) is analyzed in terms of detecting imperfections of spatial encoding gradients in order to correct for these in image reconstruction. As this technique is used as a reference method, it is given the acronym Duyn calibration technique (DCT). MFM and DCT are compared and timing delays, k‐space offsets, eddy current effects, k‐trajectory error propagation, image distortions, and signal‐to‐noise ratio were determined for different spiral sequences in two different phantoms. Results Both techniques effectively detect k‐space offsets and k‐trajectory error propagation and correct for general error sources like timing delays. In object border areas, artifacts such as deformations and blurring were dramatically reduced. Within all tested categories, MFM performed as well as DCT. In terms of k‐trajectory error propagation and image distortion quantification, MFM was more accurate. Conclusion We introduce MFM as an effective and accurate correction technique for spiral imaging, where a comparison of MFM and DCT has shown that both techniques are accurate correction techniques for spiral imaging. J. Magn. Reson. Imaging 2009;29:1485–1492. © 2009 Wiley‐Liss, Inc.</description><identifier>ISSN: 1053-1807</identifier><identifier>EISSN: 1522-2586</identifier><identifier>DOI: 10.1002/jmri.21782</identifier><identifier>PMID: 19472426</identifier><language>eng</language><publisher>Hoboken: Wiley Subscription Services, Inc., A Wiley Company</publisher><subject>artifact reduction ; Brain Mapping - methods ; Calibration ; eddy currents ; Image Enhancement - methods ; Image Processing, Computer-Assisted ; k-space trajectory correction ; magnetic field monitoring ; Magnetic Resonance Imaging - methods ; phantom studies ; Phantoms, Imaging ; spiral MRI</subject><ispartof>Journal of magnetic resonance imaging, 2009-06, Vol.29 (6), p.1485-1492</ispartof><rights>Copyright © 2009 Wiley‐Liss, Inc.</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c4012-8d558ed7399cf63034351cdd8c26ef317e9775bc045c5359e634ec239ac9449a3</citedby><cites>FETCH-LOGICAL-c4012-8d558ed7399cf63034351cdd8c26ef317e9775bc045c5359e634ec239ac9449a3</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktopdf>$$Uhttps://onlinelibrary.wiley.com/doi/pdf/10.1002%2Fjmri.21782$$EPDF$$P50$$Gwiley$$H</linktopdf><linktohtml>$$Uhttps://onlinelibrary.wiley.com/doi/full/10.1002%2Fjmri.21782$$EHTML$$P50$$Gwiley$$H</linktohtml><link.rule.ids>314,780,784,1417,1433,27924,27925,45574,45575,46409,46833</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/19472426$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Lechner, Silke M.</creatorcontrib><creatorcontrib>Sipilä, Pekka T.</creatorcontrib><creatorcontrib>Wiesinger, Florian</creatorcontrib><creatorcontrib>Kerr, Adam B.</creatorcontrib><creatorcontrib>Vogel, Mika W.</creatorcontrib><title>Spiral imaging artifact reduction: A comparison of two k-trajectory measurement methods</title><title>Journal of magnetic resonance imaging</title><addtitle>J. Magn. Reson. Imaging</addtitle><description>Purpose To compare an external sensor‐based k‐space calibration technique with a routine precalibration method for quantification of method accuracy and reduction of spiral imaging artifacts to obtain improved image quality. Materials and Methods Recently, magnetic field monitoring (MFM) has been introduced as a new calibration technique of gradient field‐related imperfections. External sensors are placed near the observed object to measure magnetic field variations during image acquisition. The measured field data are used to determine the actual k‐space trajectory and for image reconstruction to reduce artifacts. In the past, precalibration techniques have been proposed where the k‐space trajectory is measured by means of special calibration sequences directly in the object of interest. In this study, MFM is introduced as an effective correction technique for spiral imaging. On the basis of a comparison, whether MFM is as viable as the chosen reference method presented by Duyn et al (J Magn Reson [1998] 132:150–153) is analyzed in terms of detecting imperfections of spatial encoding gradients in order to correct for these in image reconstruction. As this technique is used as a reference method, it is given the acronym Duyn calibration technique (DCT). MFM and DCT are compared and timing delays, k‐space offsets, eddy current effects, k‐trajectory error propagation, image distortions, and signal‐to‐noise ratio were determined for different spiral sequences in two different phantoms. Results Both techniques effectively detect k‐space offsets and k‐trajectory error propagation and correct for general error sources like timing delays. In object border areas, artifacts such as deformations and blurring were dramatically reduced. Within all tested categories, MFM performed as well as DCT. In terms of k‐trajectory error propagation and image distortion quantification, MFM was more accurate. Conclusion We introduce MFM as an effective and accurate correction technique for spiral imaging, where a comparison of MFM and DCT has shown that both techniques are accurate correction techniques for spiral imaging. J. Magn. Reson. Imaging 2009;29:1485–1492. © 2009 Wiley‐Liss, Inc.</description><subject>artifact reduction</subject><subject>Brain Mapping - methods</subject><subject>Calibration</subject><subject>eddy currents</subject><subject>Image Enhancement - methods</subject><subject>Image Processing, Computer-Assisted</subject><subject>k-space trajectory correction</subject><subject>magnetic field monitoring</subject><subject>Magnetic Resonance Imaging - methods</subject><subject>phantom studies</subject><subject>Phantoms, Imaging</subject><subject>spiral MRI</subject><issn>1053-1807</issn><issn>1522-2586</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2009</creationdate><recordtype>article</recordtype><sourceid>EIF</sourceid><recordid>eNp9kE9P3DAQxa2KqsC2l34A5BMHpFD_jePe0AooCFotUCH1YhlnQr0k8WI7gv32zbIL3HqZeYffe5p5CH2l5JASwr7Nu-gPGVUV-4B2qGSsYLIqt0ZNJC9oRdQ22k1pTgjRWshPaJtqoZhg5Q66vV74aFvsO3vv-3tsY_aNdRlHqAeXfei_4yPsQrew0afQ49Dg_BTwQ5GjnYPLIS5xBzYNETro86jz31Cnz-hjY9sEXzZ7gn6fHN9MfxQXv07PpkcXhROEsqKqpaygVlxr15SccMEldXVdOVZCw6kCrZS8c0RIJ7nUUHIBjnFtnRZCWz5B--vcRQyPA6RsOp8ctK3tIQzJlIozTsY5QQdr0MWQUoTGLOL4dFwaSsyqRrOq0bzUOMJ7m9ThroP6Hd30NgJ0DTz5Fpb_iTLnl1dnr6HF2uNThuc3j40PqyuVNLc_Tw25-TOb8UtiZvwf7f2M4w</recordid><startdate>200906</startdate><enddate>200906</enddate><creator>Lechner, Silke M.</creator><creator>Sipilä, Pekka T.</creator><creator>Wiesinger, Florian</creator><creator>Kerr, Adam B.</creator><creator>Vogel, Mika W.</creator><general>Wiley Subscription Services, Inc., A Wiley Company</general><scope>BSCLL</scope><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope></search><sort><creationdate>200906</creationdate><title>Spiral imaging artifact reduction: A comparison of two k-trajectory measurement methods</title><author>Lechner, Silke M. ; Sipilä, Pekka T. ; Wiesinger, Florian ; Kerr, Adam B. ; Vogel, Mika W.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c4012-8d558ed7399cf63034351cdd8c26ef317e9775bc045c5359e634ec239ac9449a3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2009</creationdate><topic>artifact reduction</topic><topic>Brain Mapping - methods</topic><topic>Calibration</topic><topic>eddy currents</topic><topic>Image Enhancement - methods</topic><topic>Image Processing, Computer-Assisted</topic><topic>k-space trajectory correction</topic><topic>magnetic field monitoring</topic><topic>Magnetic Resonance Imaging - methods</topic><topic>phantom studies</topic><topic>Phantoms, Imaging</topic><topic>spiral MRI</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Lechner, Silke M.</creatorcontrib><creatorcontrib>Sipilä, Pekka T.</creatorcontrib><creatorcontrib>Wiesinger, Florian</creatorcontrib><creatorcontrib>Kerr, Adam B.</creatorcontrib><creatorcontrib>Vogel, Mika W.</creatorcontrib><collection>Istex</collection><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><jtitle>Journal of magnetic resonance imaging</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Lechner, Silke M.</au><au>Sipilä, Pekka T.</au><au>Wiesinger, Florian</au><au>Kerr, Adam B.</au><au>Vogel, Mika W.</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Spiral imaging artifact reduction: A comparison of two k-trajectory measurement methods</atitle><jtitle>Journal of magnetic resonance imaging</jtitle><addtitle>J. Magn. Reson. Imaging</addtitle><date>2009-06</date><risdate>2009</risdate><volume>29</volume><issue>6</issue><spage>1485</spage><epage>1492</epage><pages>1485-1492</pages><issn>1053-1807</issn><eissn>1522-2586</eissn><abstract>Purpose To compare an external sensor‐based k‐space calibration technique with a routine precalibration method for quantification of method accuracy and reduction of spiral imaging artifacts to obtain improved image quality. Materials and Methods Recently, magnetic field monitoring (MFM) has been introduced as a new calibration technique of gradient field‐related imperfections. External sensors are placed near the observed object to measure magnetic field variations during image acquisition. The measured field data are used to determine the actual k‐space trajectory and for image reconstruction to reduce artifacts. In the past, precalibration techniques have been proposed where the k‐space trajectory is measured by means of special calibration sequences directly in the object of interest. In this study, MFM is introduced as an effective correction technique for spiral imaging. On the basis of a comparison, whether MFM is as viable as the chosen reference method presented by Duyn et al (J Magn Reson [1998] 132:150–153) is analyzed in terms of detecting imperfections of spatial encoding gradients in order to correct for these in image reconstruction. As this technique is used as a reference method, it is given the acronym Duyn calibration technique (DCT). MFM and DCT are compared and timing delays, k‐space offsets, eddy current effects, k‐trajectory error propagation, image distortions, and signal‐to‐noise ratio were determined for different spiral sequences in two different phantoms. Results Both techniques effectively detect k‐space offsets and k‐trajectory error propagation and correct for general error sources like timing delays. In object border areas, artifacts such as deformations and blurring were dramatically reduced. Within all tested categories, MFM performed as well as DCT. In terms of k‐trajectory error propagation and image distortion quantification, MFM was more accurate. Conclusion We introduce MFM as an effective and accurate correction technique for spiral imaging, where a comparison of MFM and DCT has shown that both techniques are accurate correction techniques for spiral imaging. J. Magn. Reson. Imaging 2009;29:1485–1492. © 2009 Wiley‐Liss, Inc.</abstract><cop>Hoboken</cop><pub>Wiley Subscription Services, Inc., A Wiley Company</pub><pmid>19472426</pmid><doi>10.1002/jmri.21782</doi><tpages>8</tpages><oa>free_for_read</oa></addata></record>
fulltext fulltext
identifier ISSN: 1053-1807
ispartof Journal of magnetic resonance imaging, 2009-06, Vol.29 (6), p.1485-1492
issn 1053-1807
1522-2586
language eng
recordid cdi_proquest_miscellaneous_67323067
source MEDLINE; Wiley Online Library Free Content; Access via Wiley Online Library
subjects artifact reduction
Brain Mapping - methods
Calibration
eddy currents
Image Enhancement - methods
Image Processing, Computer-Assisted
k-space trajectory correction
magnetic field monitoring
Magnetic Resonance Imaging - methods
phantom studies
Phantoms, Imaging
spiral MRI
title Spiral imaging artifact reduction: A comparison of two k-trajectory measurement methods
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-26T13%3A34%3A16IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Spiral%20imaging%20artifact%20reduction:%20A%20comparison%20of%20two%20k-trajectory%20measurement%20methods&rft.jtitle=Journal%20of%20magnetic%20resonance%20imaging&rft.au=Lechner,%20Silke%20M.&rft.date=2009-06&rft.volume=29&rft.issue=6&rft.spage=1485&rft.epage=1492&rft.pages=1485-1492&rft.issn=1053-1807&rft.eissn=1522-2586&rft_id=info:doi/10.1002/jmri.21782&rft_dat=%3Cproquest_cross%3E67323067%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=67323067&rft_id=info:pmid/19472426&rfr_iscdi=true