Thermal sensation and comfort in transient non-uniform thermal environments
Most existing thermal comfort models are applicable only to steady-state, uniform thermal environments. This paper presents summary results from 109 human tests that were performed under non-uniform and transient conditions. In these tests, local body areas were independently heated or cooled while...
Gespeichert in:
Veröffentlicht in: | European journal of applied physiology 2004-09, Vol.92 (6), p.728-733 |
---|---|
Hauptverfasser: | , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | Most existing thermal comfort models are applicable only to steady-state, uniform thermal environments. This paper presents summary results from 109 human tests that were performed under non-uniform and transient conditions. In these tests, local body areas were independently heated or cooled while the rest of the body was exposed to a warm, neutral or cool environment. Skin temperatures, core temperature, thermal sensation and comfort responses were collected at 1- to 3-min intervals. Based on these tests, we have developed predictive models of local and overall thermal sensation and comfort. |
---|---|
ISSN: | 1439-6319 1439-6327 |
DOI: | 10.1007/s00421-004-1137-y |