Accuracy of Contrast-to-noise Ratio Measurement for Magnetic Resonance Clinical Images
The contrast-to-noise ratio (CNR.) is often used to evaluate magnetic resonance images, because it has two components, contrast and SNR, and indicates the detectability of clinical lesions. Two methods (using a phantom and using clinical images) are employed to measure CNR. In addition, there are so...
Gespeichert in:
Veröffentlicht in: | Japanese Journal of Radiological Technology 2004/11/20, Vol.60(11), pp.1543-1549 |
---|---|
Hauptverfasser: | , , , |
Format: | Artikel |
Sprache: | eng ; jpn |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
container_end_page | 1549 |
---|---|
container_issue | 11 |
container_start_page | 1543 |
container_title | Japanese Journal of Radiological Technology |
container_volume | 60 |
creator | OGURA, AKIO MAEDA, FUMIE MIYAI, AKIRA HONGOH, TAKAHARU |
description | The contrast-to-noise ratio (CNR.) is often used to evaluate magnetic resonance images, because it has two components, contrast and SNR, and indicates the detectability of clinical lesions. Two methods (using a phantom and using clinical images) are employed to measure CNR. In addition, there are some methods of measurement that use clinical images. In this report, the accuracy of measurement and correlation for signal detectability were evaluated in four methods of measuring CNR using clinical images. The results indicated that the inter-tissue method using an air signal provided good accuracy and was consistent with signal detectability using observer performance. In addition, a small region of interest (ROI) was better suited as the target for CNR measurement using clinical images. |
doi_str_mv | 10.6009/jjrt.KJ00003326578 |
format | Article |
fullrecord | <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_67138426</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>67138426</sourcerecordid><originalsourceid>FETCH-LOGICAL-c3268-15a5d19a69c9b95b509b0ea494f9b7143f36e042f6f84a392ca4e21827f15623</originalsourceid><addsrcrecordid>eNpVkE1LXDEUhkOp1MH6B7ooWXV3bXLzMclShlanVQoibsO58cTe4d7EJrkL_30zzKCYRQLheV_OeQj5wtmFZsx-3-1yvfj9i7UjRK_V2nwgK24M76Qx4iNZMaFtJwVTp-S8lHFooG1fTH4ip1wpbRjTK_Jw6f2Swb_QFOgmxZqh1K6mLqaxIL2DOiZ6i1CWjDPGSkPK9BaeItbR0zssKUL0SDfTGEcPE93O8ITlMzkJMBU8P75n5P7nj_vNdXfz52q7ubzpfJvZdFyBeuQWtPV2sGpQzA4MQVoZ7LDmUgShkck-6GAkCNt7kNhz068DV7oXZ-TbofY5p38LlurmsXicJoiYluL0mgsje93A_gD6nErJGNxzHmfIL44zt_fp9j7dO58t9PXYvgwzPr5FjvYasD0Au1Lb1q8A5CZnwkOnZo7z_f2u_JXxfyE7jOI_9fGKbA</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>67138426</pqid></control><display><type>article</type><title>Accuracy of Contrast-to-noise Ratio Measurement for Magnetic Resonance Clinical Images</title><source>MEDLINE</source><source>Elektronische Zeitschriftenbibliothek - Frei zugängliche E-Journals</source><creator>OGURA, AKIO ; MAEDA, FUMIE ; MIYAI, AKIRA ; HONGOH, TAKAHARU</creator><creatorcontrib>OGURA, AKIO ; MAEDA, FUMIE ; MIYAI, AKIRA ; HONGOH, TAKAHARU</creatorcontrib><description>The contrast-to-noise ratio (CNR.) is often used to evaluate magnetic resonance images, because it has two components, contrast and SNR, and indicates the detectability of clinical lesions. Two methods (using a phantom and using clinical images) are employed to measure CNR. In addition, there are some methods of measurement that use clinical images. In this report, the accuracy of measurement and correlation for signal detectability were evaluated in four methods of measuring CNR using clinical images. The results indicated that the inter-tissue method using an air signal provided good accuracy and was consistent with signal detectability using observer performance. In addition, a small region of interest (ROI) was better suited as the target for CNR measurement using clinical images.</description><identifier>ISSN: 0369-4305</identifier><identifier>EISSN: 1881-4883</identifier><identifier>DOI: 10.6009/jjrt.KJ00003326578</identifier><identifier>PMID: 15568006</identifier><language>eng ; jpn</language><publisher>Japan: Japanese Society of Radiological Technology</publisher><subject>Brain - anatomy & histology ; Contrast-to-noise ratio (CNR) ; Detectability ; Humans ; Magnetic resonance imaging ; Magnetic Resonance Imaging - methods ; Phantoms, Imaging ; Sensitivity and Specificity</subject><ispartof>Japanese Journal of Radiological Technology, 2004/11/20, Vol.60(11), pp.1543-1549</ispartof><rights>2004 Japanese Society of Radiological Technology</rights><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c3268-15a5d19a69c9b95b509b0ea494f9b7143f36e042f6f84a392ca4e21827f15623</citedby><cites>FETCH-LOGICAL-c3268-15a5d19a69c9b95b509b0ea494f9b7143f36e042f6f84a392ca4e21827f15623</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,776,780,27901,27902</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/15568006$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>OGURA, AKIO</creatorcontrib><creatorcontrib>MAEDA, FUMIE</creatorcontrib><creatorcontrib>MIYAI, AKIRA</creatorcontrib><creatorcontrib>HONGOH, TAKAHARU</creatorcontrib><title>Accuracy of Contrast-to-noise Ratio Measurement for Magnetic Resonance Clinical Images</title><title>Japanese Journal of Radiological Technology</title><addtitle>Jpn. J. Radiol. Technol.</addtitle><description>The contrast-to-noise ratio (CNR.) is often used to evaluate magnetic resonance images, because it has two components, contrast and SNR, and indicates the detectability of clinical lesions. Two methods (using a phantom and using clinical images) are employed to measure CNR. In addition, there are some methods of measurement that use clinical images. In this report, the accuracy of measurement and correlation for signal detectability were evaluated in four methods of measuring CNR using clinical images. The results indicated that the inter-tissue method using an air signal provided good accuracy and was consistent with signal detectability using observer performance. In addition, a small region of interest (ROI) was better suited as the target for CNR measurement using clinical images.</description><subject>Brain - anatomy & histology</subject><subject>Contrast-to-noise ratio (CNR)</subject><subject>Detectability</subject><subject>Humans</subject><subject>Magnetic resonance imaging</subject><subject>Magnetic Resonance Imaging - methods</subject><subject>Phantoms, Imaging</subject><subject>Sensitivity and Specificity</subject><issn>0369-4305</issn><issn>1881-4883</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2004</creationdate><recordtype>article</recordtype><sourceid>EIF</sourceid><recordid>eNpVkE1LXDEUhkOp1MH6B7ooWXV3bXLzMclShlanVQoibsO58cTe4d7EJrkL_30zzKCYRQLheV_OeQj5wtmFZsx-3-1yvfj9i7UjRK_V2nwgK24M76Qx4iNZMaFtJwVTp-S8lHFooG1fTH4ip1wpbRjTK_Jw6f2Swb_QFOgmxZqh1K6mLqaxIL2DOiZ6i1CWjDPGSkPK9BaeItbR0zssKUL0SDfTGEcPE93O8ITlMzkJMBU8P75n5P7nj_vNdXfz52q7ubzpfJvZdFyBeuQWtPV2sGpQzA4MQVoZ7LDmUgShkck-6GAkCNt7kNhz068DV7oXZ-TbofY5p38LlurmsXicJoiYluL0mgsje93A_gD6nErJGNxzHmfIL44zt_fp9j7dO58t9PXYvgwzPr5FjvYasD0Au1Lb1q8A5CZnwkOnZo7z_f2u_JXxfyE7jOI_9fGKbA</recordid><startdate>200411</startdate><enddate>200411</enddate><creator>OGURA, AKIO</creator><creator>MAEDA, FUMIE</creator><creator>MIYAI, AKIRA</creator><creator>HONGOH, TAKAHARU</creator><general>Japanese Society of Radiological Technology</general><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope></search><sort><creationdate>200411</creationdate><title>Accuracy of Contrast-to-noise Ratio Measurement for Magnetic Resonance Clinical Images</title><author>OGURA, AKIO ; MAEDA, FUMIE ; MIYAI, AKIRA ; HONGOH, TAKAHARU</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c3268-15a5d19a69c9b95b509b0ea494f9b7143f36e042f6f84a392ca4e21827f15623</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng ; jpn</language><creationdate>2004</creationdate><topic>Brain - anatomy & histology</topic><topic>Contrast-to-noise ratio (CNR)</topic><topic>Detectability</topic><topic>Humans</topic><topic>Magnetic resonance imaging</topic><topic>Magnetic Resonance Imaging - methods</topic><topic>Phantoms, Imaging</topic><topic>Sensitivity and Specificity</topic><toplevel>online_resources</toplevel><creatorcontrib>OGURA, AKIO</creatorcontrib><creatorcontrib>MAEDA, FUMIE</creatorcontrib><creatorcontrib>MIYAI, AKIRA</creatorcontrib><creatorcontrib>HONGOH, TAKAHARU</creatorcontrib><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><jtitle>Japanese Journal of Radiological Technology</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>OGURA, AKIO</au><au>MAEDA, FUMIE</au><au>MIYAI, AKIRA</au><au>HONGOH, TAKAHARU</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Accuracy of Contrast-to-noise Ratio Measurement for Magnetic Resonance Clinical Images</atitle><jtitle>Japanese Journal of Radiological Technology</jtitle><addtitle>Jpn. J. Radiol. Technol.</addtitle><date>2004-11</date><risdate>2004</risdate><volume>60</volume><issue>11</issue><spage>1543</spage><epage>1549</epage><pages>1543-1549</pages><issn>0369-4305</issn><eissn>1881-4883</eissn><abstract>The contrast-to-noise ratio (CNR.) is often used to evaluate magnetic resonance images, because it has two components, contrast and SNR, and indicates the detectability of clinical lesions. Two methods (using a phantom and using clinical images) are employed to measure CNR. In addition, there are some methods of measurement that use clinical images. In this report, the accuracy of measurement and correlation for signal detectability were evaluated in four methods of measuring CNR using clinical images. The results indicated that the inter-tissue method using an air signal provided good accuracy and was consistent with signal detectability using observer performance. In addition, a small region of interest (ROI) was better suited as the target for CNR measurement using clinical images.</abstract><cop>Japan</cop><pub>Japanese Society of Radiological Technology</pub><pmid>15568006</pmid><doi>10.6009/jjrt.KJ00003326578</doi><tpages>7</tpages><oa>free_for_read</oa></addata></record> |
fulltext | fulltext |
identifier | ISSN: 0369-4305 |
ispartof | Japanese Journal of Radiological Technology, 2004/11/20, Vol.60(11), pp.1543-1549 |
issn | 0369-4305 1881-4883 |
language | eng ; jpn |
recordid | cdi_proquest_miscellaneous_67138426 |
source | MEDLINE; Elektronische Zeitschriftenbibliothek - Frei zugängliche E-Journals |
subjects | Brain - anatomy & histology Contrast-to-noise ratio (CNR) Detectability Humans Magnetic resonance imaging Magnetic Resonance Imaging - methods Phantoms, Imaging Sensitivity and Specificity |
title | Accuracy of Contrast-to-noise Ratio Measurement for Magnetic Resonance Clinical Images |
url | https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-02-01T22%3A55%3A00IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Accuracy%20of%20Contrast-to-noise%20Ratio%20Measurement%20for%20Magnetic%20Resonance%20Clinical%20Images&rft.jtitle=Japanese%20Journal%20of%20Radiological%20Technology&rft.au=OGURA,%20AKIO&rft.date=2004-11&rft.volume=60&rft.issue=11&rft.spage=1543&rft.epage=1549&rft.pages=1543-1549&rft.issn=0369-4305&rft.eissn=1881-4883&rft_id=info:doi/10.6009/jjrt.KJ00003326578&rft_dat=%3Cproquest_cross%3E67138426%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=67138426&rft_id=info:pmid/15568006&rfr_iscdi=true |