Tissue Doppler Imaging Measurement of Left Ventricular Systolic Function in Children: Mitral Annular Displacement Index Is Superior to Peak Velocity

Background Doppler tissue imaging (DTI)–derived mitral annular systolic peak S-wave velocity (S′) correlates with left ventricular (LV) ejection fraction (EF). The authors hypothesized that DTI mitral annular displacement, which is equal to the velocity-time integral of the DTI S′ wave, might be sup...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Journal of the American Society of Echocardiography 2009-04, Vol.22 (4), p.376-382
Hauptverfasser: Roberson, David A., MD, Cui, Wei, MD
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 382
container_issue 4
container_start_page 376
container_title Journal of the American Society of Echocardiography
container_volume 22
creator Roberson, David A., MD
Cui, Wei, MD
description Background Doppler tissue imaging (DTI)–derived mitral annular systolic peak S-wave velocity (S′) correlates with left ventricular (LV) ejection fraction (EF). The authors hypothesized that DTI mitral annular displacement, which is equal to the velocity-time integral of the DTI S′ wave, might be superior to S′ to analyze LV systolic function. Because S′ varies with age, it was expressed as S z , the z -score variance from normal S′ for each subject. Because displacement varies with heart size, it was expressed as a displacement index, or the DTI S′-wave velocity-time integral divided by the end-diastolic distance from the mitral annulus to the LV apex. The aims of this study were to (1) measure the accuracy, sensitivity, specificity, and positive and negative predictive values of displacement index compared with S z to detect systolic dysfunction; (2) compare displacement index with other quantitative parameters of longitudinal systolic function, including color DTI–derived strain and two-dimensional speckle-tracking echocardiography (2D)–derived mitral annular displacement and strain; and (3) determine the effects of age, heart rate (HR), and body surface area (BSA) on displacement index. Methods Displacement index and S z results were compared with EF and with each other using statistical tests, including independent t tests, linear regression, receiver operating characteristic curve analysis, and 2 × 2 probability tables. Displacement index was also compared with other parameters of longitudinal systolic function, age, HR, and BSA using regression analysis. Results Forty-six patients had normal (EF ≥ 55%) and 34 abnormal (EF < 55%) LV function. Groups were statistically equivalent ( P > .05) for age, HR, and BSA and statistically different ( P < .001) for all measured parameters of systolic function. Displacement index and EF were linearly related. Receiver operating characteristic curve analysis showed the sensitivity of displacement index to be greater than that of S z throughout the study range. Probability table analysis demonstrated that for predicting EF < 55%, the sensitivity, accuracy, and negative predictive value were greater for displacement index than for S z . Displacement index was linearly correlated with 2D mitral annular longitudinal displacement, 2D LV basal segment longitudinal strain, and color DTI LV basal segment longitudinal strain. Displacement index was not affected by age, HR, or BSA. Conclusions Displacement index is linearly
doi_str_mv 10.1016/j.echo.2009.01.008
format Article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_67113064</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><els_id>S0894731709000431</els_id><sourcerecordid>67113064</sourcerecordid><originalsourceid>FETCH-LOGICAL-c475t-8cb06e3681cd2198b66cad2989576074a0ef3bd4516a1832389c3a689dd460513</originalsourceid><addsrcrecordid>eNp9klGL1DAUhYso7uzqH_BB8uRb603TJo2IsMy6OjCLwqy-hkx6u5vZTFKTVpz_sT_Y1hkQfPApXPjOueSek2WvKBQUKH-7K9Dch6IEkAXQAqB5ki0oSJFzIeun2QIaWeWCUXGWnae0A4C6AXienVFZcimEXGSPtzalEclV6HuHkaz2-s76O3KDOo0R9-gHEjqyxm4g36chWjM6HcnmkIbgrCHXozeDDZ5YT5b31rUR_TtyY4eoHbn0_g99ZVPvtDnarXyLv8gqkc3YY7QhkiGQr6gfpgUuGDscXmTPOu0Svjy9F9m364-3y8_5-sun1fJynZtK1EPemC1wZLyhpi2pbLacG92WspG14CAqDdixbVvVlGvasJI10jDNG9m2FYeasovszdG3j-HHiGlQe5sMOqc9hjEpLihlwKsJLI-giSGliJ3qo93reFAU1JyF2qk5CzVnoYCqKYtJ9PrkPm732P6VnI4_Ae-PAE5__GkxqmQseoOtjWgG1Qb7f_8P_8iNs94a7R7wgGkXxuin6ymqUqlAbeY2zGUAORWhYpT9Blm_sPQ</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>67113064</pqid></control><display><type>article</type><title>Tissue Doppler Imaging Measurement of Left Ventricular Systolic Function in Children: Mitral Annular Displacement Index Is Superior to Peak Velocity</title><source>MEDLINE</source><source>Elsevier ScienceDirect Journals Complete</source><creator>Roberson, David A., MD ; Cui, Wei, MD</creator><creatorcontrib>Roberson, David A., MD ; Cui, Wei, MD</creatorcontrib><description>Background Doppler tissue imaging (DTI)–derived mitral annular systolic peak S-wave velocity (S′) correlates with left ventricular (LV) ejection fraction (EF). The authors hypothesized that DTI mitral annular displacement, which is equal to the velocity-time integral of the DTI S′ wave, might be superior to S′ to analyze LV systolic function. Because S′ varies with age, it was expressed as S z , the z -score variance from normal S′ for each subject. Because displacement varies with heart size, it was expressed as a displacement index, or the DTI S′-wave velocity-time integral divided by the end-diastolic distance from the mitral annulus to the LV apex. The aims of this study were to (1) measure the accuracy, sensitivity, specificity, and positive and negative predictive values of displacement index compared with S z to detect systolic dysfunction; (2) compare displacement index with other quantitative parameters of longitudinal systolic function, including color DTI–derived strain and two-dimensional speckle-tracking echocardiography (2D)–derived mitral annular displacement and strain; and (3) determine the effects of age, heart rate (HR), and body surface area (BSA) on displacement index. Methods Displacement index and S z results were compared with EF and with each other using statistical tests, including independent t tests, linear regression, receiver operating characteristic curve analysis, and 2 × 2 probability tables. Displacement index was also compared with other parameters of longitudinal systolic function, age, HR, and BSA using regression analysis. Results Forty-six patients had normal (EF ≥ 55%) and 34 abnormal (EF &lt; 55%) LV function. Groups were statistically equivalent ( P &gt; .05) for age, HR, and BSA and statistically different ( P &lt; .001) for all measured parameters of systolic function. Displacement index and EF were linearly related. Receiver operating characteristic curve analysis showed the sensitivity of displacement index to be greater than that of S z throughout the study range. Probability table analysis demonstrated that for predicting EF &lt; 55%, the sensitivity, accuracy, and negative predictive value were greater for displacement index than for S z . Displacement index was linearly correlated with 2D mitral annular longitudinal displacement, 2D LV basal segment longitudinal strain, and color DTI LV basal segment longitudinal strain. Displacement index was not affected by age, HR, or BSA. Conclusions Displacement index is linearly related to EF and also to other parameters of longitudinal systolic function. Displacement index has some advantages over S z for assessing ventricular systolic function and should prove useful in measuring longitudinal and global LV systolic function.</description><identifier>ISSN: 0894-7317</identifier><identifier>EISSN: 1097-6795</identifier><identifier>DOI: 10.1016/j.echo.2009.01.008</identifier><identifier>PMID: 19269779</identifier><language>eng</language><publisher>United States: Mosby, Inc</publisher><subject>Adolescent ; Algorithms ; Cardiovascular ; Child ; Child, Preschool ; Doppler tissue imaging ; Echocardiography, Doppler - methods ; Elasticity Imaging Techniques - methods ; Female ; Humans ; Image Enhancement - methods ; Image Interpretation, Computer-Assisted - methods ; Infant ; Male ; Mitral annular displacement ; Mitral Valve - diagnostic imaging ; Myocardial strain ; Reproducibility of Results ; Sensitivity and Specificity ; Systolic function ; Ventricular Dysfunction, Left - diagnostic imaging</subject><ispartof>Journal of the American Society of Echocardiography, 2009-04, Vol.22 (4), p.376-382</ispartof><rights>American Society of Echocardiography</rights><rights>2009 American Society of Echocardiography</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c475t-8cb06e3681cd2198b66cad2989576074a0ef3bd4516a1832389c3a689dd460513</citedby><cites>FETCH-LOGICAL-c475t-8cb06e3681cd2198b66cad2989576074a0ef3bd4516a1832389c3a689dd460513</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://dx.doi.org/10.1016/j.echo.2009.01.008$$EHTML$$P50$$Gelsevier$$H</linktohtml><link.rule.ids>314,780,784,3550,27924,27925,45995</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/19269779$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Roberson, David A., MD</creatorcontrib><creatorcontrib>Cui, Wei, MD</creatorcontrib><title>Tissue Doppler Imaging Measurement of Left Ventricular Systolic Function in Children: Mitral Annular Displacement Index Is Superior to Peak Velocity</title><title>Journal of the American Society of Echocardiography</title><addtitle>J Am Soc Echocardiogr</addtitle><description>Background Doppler tissue imaging (DTI)–derived mitral annular systolic peak S-wave velocity (S′) correlates with left ventricular (LV) ejection fraction (EF). The authors hypothesized that DTI mitral annular displacement, which is equal to the velocity-time integral of the DTI S′ wave, might be superior to S′ to analyze LV systolic function. Because S′ varies with age, it was expressed as S z , the z -score variance from normal S′ for each subject. Because displacement varies with heart size, it was expressed as a displacement index, or the DTI S′-wave velocity-time integral divided by the end-diastolic distance from the mitral annulus to the LV apex. The aims of this study were to (1) measure the accuracy, sensitivity, specificity, and positive and negative predictive values of displacement index compared with S z to detect systolic dysfunction; (2) compare displacement index with other quantitative parameters of longitudinal systolic function, including color DTI–derived strain and two-dimensional speckle-tracking echocardiography (2D)–derived mitral annular displacement and strain; and (3) determine the effects of age, heart rate (HR), and body surface area (BSA) on displacement index. Methods Displacement index and S z results were compared with EF and with each other using statistical tests, including independent t tests, linear regression, receiver operating characteristic curve analysis, and 2 × 2 probability tables. Displacement index was also compared with other parameters of longitudinal systolic function, age, HR, and BSA using regression analysis. Results Forty-six patients had normal (EF ≥ 55%) and 34 abnormal (EF &lt; 55%) LV function. Groups were statistically equivalent ( P &gt; .05) for age, HR, and BSA and statistically different ( P &lt; .001) for all measured parameters of systolic function. Displacement index and EF were linearly related. Receiver operating characteristic curve analysis showed the sensitivity of displacement index to be greater than that of S z throughout the study range. Probability table analysis demonstrated that for predicting EF &lt; 55%, the sensitivity, accuracy, and negative predictive value were greater for displacement index than for S z . Displacement index was linearly correlated with 2D mitral annular longitudinal displacement, 2D LV basal segment longitudinal strain, and color DTI LV basal segment longitudinal strain. Displacement index was not affected by age, HR, or BSA. Conclusions Displacement index is linearly related to EF and also to other parameters of longitudinal systolic function. Displacement index has some advantages over S z for assessing ventricular systolic function and should prove useful in measuring longitudinal and global LV systolic function.</description><subject>Adolescent</subject><subject>Algorithms</subject><subject>Cardiovascular</subject><subject>Child</subject><subject>Child, Preschool</subject><subject>Doppler tissue imaging</subject><subject>Echocardiography, Doppler - methods</subject><subject>Elasticity Imaging Techniques - methods</subject><subject>Female</subject><subject>Humans</subject><subject>Image Enhancement - methods</subject><subject>Image Interpretation, Computer-Assisted - methods</subject><subject>Infant</subject><subject>Male</subject><subject>Mitral annular displacement</subject><subject>Mitral Valve - diagnostic imaging</subject><subject>Myocardial strain</subject><subject>Reproducibility of Results</subject><subject>Sensitivity and Specificity</subject><subject>Systolic function</subject><subject>Ventricular Dysfunction, Left - diagnostic imaging</subject><issn>0894-7317</issn><issn>1097-6795</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2009</creationdate><recordtype>article</recordtype><sourceid>EIF</sourceid><recordid>eNp9klGL1DAUhYso7uzqH_BB8uRb603TJo2IsMy6OjCLwqy-hkx6u5vZTFKTVpz_sT_Y1hkQfPApXPjOueSek2WvKBQUKH-7K9Dch6IEkAXQAqB5ki0oSJFzIeun2QIaWeWCUXGWnae0A4C6AXienVFZcimEXGSPtzalEclV6HuHkaz2-s76O3KDOo0R9-gHEjqyxm4g36chWjM6HcnmkIbgrCHXozeDDZ5YT5b31rUR_TtyY4eoHbn0_g99ZVPvtDnarXyLv8gqkc3YY7QhkiGQr6gfpgUuGDscXmTPOu0Svjy9F9m364-3y8_5-sun1fJynZtK1EPemC1wZLyhpi2pbLacG92WspG14CAqDdixbVvVlGvasJI10jDNG9m2FYeasovszdG3j-HHiGlQe5sMOqc9hjEpLihlwKsJLI-giSGliJ3qo93reFAU1JyF2qk5CzVnoYCqKYtJ9PrkPm732P6VnI4_Ae-PAE5__GkxqmQseoOtjWgG1Qb7f_8P_8iNs94a7R7wgGkXxuin6ymqUqlAbeY2zGUAORWhYpT9Blm_sPQ</recordid><startdate>20090401</startdate><enddate>20090401</enddate><creator>Roberson, David A., MD</creator><creator>Cui, Wei, MD</creator><general>Mosby, Inc</general><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope></search><sort><creationdate>20090401</creationdate><title>Tissue Doppler Imaging Measurement of Left Ventricular Systolic Function in Children: Mitral Annular Displacement Index Is Superior to Peak Velocity</title><author>Roberson, David A., MD ; Cui, Wei, MD</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c475t-8cb06e3681cd2198b66cad2989576074a0ef3bd4516a1832389c3a689dd460513</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2009</creationdate><topic>Adolescent</topic><topic>Algorithms</topic><topic>Cardiovascular</topic><topic>Child</topic><topic>Child, Preschool</topic><topic>Doppler tissue imaging</topic><topic>Echocardiography, Doppler - methods</topic><topic>Elasticity Imaging Techniques - methods</topic><topic>Female</topic><topic>Humans</topic><topic>Image Enhancement - methods</topic><topic>Image Interpretation, Computer-Assisted - methods</topic><topic>Infant</topic><topic>Male</topic><topic>Mitral annular displacement</topic><topic>Mitral Valve - diagnostic imaging</topic><topic>Myocardial strain</topic><topic>Reproducibility of Results</topic><topic>Sensitivity and Specificity</topic><topic>Systolic function</topic><topic>Ventricular Dysfunction, Left - diagnostic imaging</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Roberson, David A., MD</creatorcontrib><creatorcontrib>Cui, Wei, MD</creatorcontrib><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><jtitle>Journal of the American Society of Echocardiography</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Roberson, David A., MD</au><au>Cui, Wei, MD</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Tissue Doppler Imaging Measurement of Left Ventricular Systolic Function in Children: Mitral Annular Displacement Index Is Superior to Peak Velocity</atitle><jtitle>Journal of the American Society of Echocardiography</jtitle><addtitle>J Am Soc Echocardiogr</addtitle><date>2009-04-01</date><risdate>2009</risdate><volume>22</volume><issue>4</issue><spage>376</spage><epage>382</epage><pages>376-382</pages><issn>0894-7317</issn><eissn>1097-6795</eissn><abstract>Background Doppler tissue imaging (DTI)–derived mitral annular systolic peak S-wave velocity (S′) correlates with left ventricular (LV) ejection fraction (EF). The authors hypothesized that DTI mitral annular displacement, which is equal to the velocity-time integral of the DTI S′ wave, might be superior to S′ to analyze LV systolic function. Because S′ varies with age, it was expressed as S z , the z -score variance from normal S′ for each subject. Because displacement varies with heart size, it was expressed as a displacement index, or the DTI S′-wave velocity-time integral divided by the end-diastolic distance from the mitral annulus to the LV apex. The aims of this study were to (1) measure the accuracy, sensitivity, specificity, and positive and negative predictive values of displacement index compared with S z to detect systolic dysfunction; (2) compare displacement index with other quantitative parameters of longitudinal systolic function, including color DTI–derived strain and two-dimensional speckle-tracking echocardiography (2D)–derived mitral annular displacement and strain; and (3) determine the effects of age, heart rate (HR), and body surface area (BSA) on displacement index. Methods Displacement index and S z results were compared with EF and with each other using statistical tests, including independent t tests, linear regression, receiver operating characteristic curve analysis, and 2 × 2 probability tables. Displacement index was also compared with other parameters of longitudinal systolic function, age, HR, and BSA using regression analysis. Results Forty-six patients had normal (EF ≥ 55%) and 34 abnormal (EF &lt; 55%) LV function. Groups were statistically equivalent ( P &gt; .05) for age, HR, and BSA and statistically different ( P &lt; .001) for all measured parameters of systolic function. Displacement index and EF were linearly related. Receiver operating characteristic curve analysis showed the sensitivity of displacement index to be greater than that of S z throughout the study range. Probability table analysis demonstrated that for predicting EF &lt; 55%, the sensitivity, accuracy, and negative predictive value were greater for displacement index than for S z . Displacement index was linearly correlated with 2D mitral annular longitudinal displacement, 2D LV basal segment longitudinal strain, and color DTI LV basal segment longitudinal strain. Displacement index was not affected by age, HR, or BSA. Conclusions Displacement index is linearly related to EF and also to other parameters of longitudinal systolic function. Displacement index has some advantages over S z for assessing ventricular systolic function and should prove useful in measuring longitudinal and global LV systolic function.</abstract><cop>United States</cop><pub>Mosby, Inc</pub><pmid>19269779</pmid><doi>10.1016/j.echo.2009.01.008</doi><tpages>7</tpages></addata></record>
fulltext fulltext
identifier ISSN: 0894-7317
ispartof Journal of the American Society of Echocardiography, 2009-04, Vol.22 (4), p.376-382
issn 0894-7317
1097-6795
language eng
recordid cdi_proquest_miscellaneous_67113064
source MEDLINE; Elsevier ScienceDirect Journals Complete
subjects Adolescent
Algorithms
Cardiovascular
Child
Child, Preschool
Doppler tissue imaging
Echocardiography, Doppler - methods
Elasticity Imaging Techniques - methods
Female
Humans
Image Enhancement - methods
Image Interpretation, Computer-Assisted - methods
Infant
Male
Mitral annular displacement
Mitral Valve - diagnostic imaging
Myocardial strain
Reproducibility of Results
Sensitivity and Specificity
Systolic function
Ventricular Dysfunction, Left - diagnostic imaging
title Tissue Doppler Imaging Measurement of Left Ventricular Systolic Function in Children: Mitral Annular Displacement Index Is Superior to Peak Velocity
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-04T18%3A42%3A34IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Tissue%20Doppler%20Imaging%20Measurement%20of%20Left%20Ventricular%20Systolic%20Function%20in%20Children:%20Mitral%20Annular%20Displacement%20Index%20Is%20Superior%20to%20Peak%20Velocity&rft.jtitle=Journal%20of%20the%20American%20Society%20of%20Echocardiography&rft.au=Roberson,%20David%20A.,%20MD&rft.date=2009-04-01&rft.volume=22&rft.issue=4&rft.spage=376&rft.epage=382&rft.pages=376-382&rft.issn=0894-7317&rft.eissn=1097-6795&rft_id=info:doi/10.1016/j.echo.2009.01.008&rft_dat=%3Cproquest_cross%3E67113064%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=67113064&rft_id=info:pmid/19269779&rft_els_id=S0894731709000431&rfr_iscdi=true