Development of an analytical reversed-phase high-performance liquid chromatography-electrospray ionization mass spectrometry method for characterization of recombinant antibodies
Analytical characterization of monoclonal antibodies has been hindered by the lack of appropriate chromatographic methods to be used in conjunction with high-resolution MS. Current methodologies for standard RP-HPLC are incompatible with antibodies due to irreproducibility, low recovery, short colum...
Gespeichert in:
Veröffentlicht in: | Journal of Chromatography A 2004-10, Vol.1053 (1-2), p.299-305 |
---|---|
Hauptverfasser: | , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
container_end_page | 305 |
---|---|
container_issue | 1-2 |
container_start_page | 299 |
container_title | Journal of Chromatography A |
container_volume | 1053 |
creator | Dillon, Thomas M Bondarenko, Pavel V Speed Ricci, Margaret |
description | Analytical characterization of monoclonal antibodies has been hindered by the lack of appropriate chromatographic methods to be used in conjunction with high-resolution MS. Current methodologies for standard RP-HPLC are incompatible with antibodies due to irreproducibility, low recovery, short column lifetimes, and poor resolution of degradation products. An analytical RP-HPLC-MS method was developed for monitoring and characterizing intact IgG1antibodies. Key parameters required for improved chromatographic resolution included long alkyl chains of the stationary phase (Zorbax SB300 C8), column temperatures elevated to 65-70 degrees C and combination of trifluoroacetic acid and heptafluorobutyric acid ion-pairing agents. RP chromatographic separation of degradation species and C-terminal lysine variants along with the characterization of glycosylation profile by mass spectrometry demonstrates the capability of this method for whole antibody analysis. |
doi_str_mv | 10.1016/s0021-9673(04)01410-4 |
format | Article |
fullrecord | <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_67070252</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>67070252</sourcerecordid><originalsourceid>FETCH-LOGICAL-c2186-e32b9a3b48adf430119ecc8276a08731de67d1b355209a384b330c55b678c3ea3</originalsourceid><addsrcrecordid>eNpFkc1O3TAQhb1oVSj0EVp5hegiZRw7f8sKaKmExKKwtibOhBjFcbBzkcJj8YT1vdyCZHskz5kzY3-MfRXwQ4AozyJALrKmrOQpqO8glIBMfWCHb9cH7HOMDwCigir_xA5EUSjZNOUhe7mgJxr97GhauO85TmnhuC7W4MhDSoZIXTYPGIkP9n7IZgq9Dw4nQ3y0jxvbcTME73Dx9wHnYc1oJLMEH-eAK7d-ss-4pMAdxsjjvEs6WsLK0zn4jie_5IEBzULhvzoNE8h419oJ02xp29Z3luIx-9jjGOnLPh6xu1-Xt-dX2fXN7z_nP68zk4u6zEjmbYOyVTV2vZIgREPG1HlVItSVFB2VVSdaWRQ5JF2tWinBFEVbVrWRhPKInbz6zsE_bigu2tloaBxxIr-JukyfCXmRJ2HxKjTp0TFQr-dgHYZVC9BbQPrvloTektCg9A6QVqnu277BpnXUvVft6ch_Z3qUXQ</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>67070252</pqid></control><display><type>article</type><title>Development of an analytical reversed-phase high-performance liquid chromatography-electrospray ionization mass spectrometry method for characterization of recombinant antibodies</title><source>MEDLINE</source><source>Access via ScienceDirect (Elsevier)</source><creator>Dillon, Thomas M ; Bondarenko, Pavel V ; Speed Ricci, Margaret</creator><creatorcontrib>Dillon, Thomas M ; Bondarenko, Pavel V ; Speed Ricci, Margaret</creatorcontrib><description>Analytical characterization of monoclonal antibodies has been hindered by the lack of appropriate chromatographic methods to be used in conjunction with high-resolution MS. Current methodologies for standard RP-HPLC are incompatible with antibodies due to irreproducibility, low recovery, short column lifetimes, and poor resolution of degradation products. An analytical RP-HPLC-MS method was developed for monitoring and characterizing intact IgG1antibodies. Key parameters required for improved chromatographic resolution included long alkyl chains of the stationary phase (Zorbax SB300 C8), column temperatures elevated to 65-70 degrees C and combination of trifluoroacetic acid and heptafluorobutyric acid ion-pairing agents. RP chromatographic separation of degradation species and C-terminal lysine variants along with the characterization of glycosylation profile by mass spectrometry demonstrates the capability of this method for whole antibody analysis.</description><identifier>ISSN: 0021-9673</identifier><identifier>DOI: 10.1016/s0021-9673(04)01410-4</identifier><identifier>PMID: 15543996</identifier><language>eng</language><publisher>Netherlands</publisher><subject>Antibodies - chemistry ; Chromatography, Gel - methods ; Chromatography, High Pressure Liquid - methods ; Recombinant Proteins - chemistry ; Spectrometry, Mass, Electrospray Ionization - methods</subject><ispartof>Journal of Chromatography A, 2004-10, Vol.1053 (1-2), p.299-305</ispartof><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c2186-e32b9a3b48adf430119ecc8276a08731de67d1b355209a384b330c55b678c3ea3</citedby></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,780,784,27924,27925</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/15543996$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Dillon, Thomas M</creatorcontrib><creatorcontrib>Bondarenko, Pavel V</creatorcontrib><creatorcontrib>Speed Ricci, Margaret</creatorcontrib><title>Development of an analytical reversed-phase high-performance liquid chromatography-electrospray ionization mass spectrometry method for characterization of recombinant antibodies</title><title>Journal of Chromatography A</title><addtitle>J Chromatogr A</addtitle><description>Analytical characterization of monoclonal antibodies has been hindered by the lack of appropriate chromatographic methods to be used in conjunction with high-resolution MS. Current methodologies for standard RP-HPLC are incompatible with antibodies due to irreproducibility, low recovery, short column lifetimes, and poor resolution of degradation products. An analytical RP-HPLC-MS method was developed for monitoring and characterizing intact IgG1antibodies. Key parameters required for improved chromatographic resolution included long alkyl chains of the stationary phase (Zorbax SB300 C8), column temperatures elevated to 65-70 degrees C and combination of trifluoroacetic acid and heptafluorobutyric acid ion-pairing agents. RP chromatographic separation of degradation species and C-terminal lysine variants along with the characterization of glycosylation profile by mass spectrometry demonstrates the capability of this method for whole antibody analysis.</description><subject>Antibodies - chemistry</subject><subject>Chromatography, Gel - methods</subject><subject>Chromatography, High Pressure Liquid - methods</subject><subject>Recombinant Proteins - chemistry</subject><subject>Spectrometry, Mass, Electrospray Ionization - methods</subject><issn>0021-9673</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2004</creationdate><recordtype>article</recordtype><sourceid>EIF</sourceid><recordid>eNpFkc1O3TAQhb1oVSj0EVp5hegiZRw7f8sKaKmExKKwtibOhBjFcbBzkcJj8YT1vdyCZHskz5kzY3-MfRXwQ4AozyJALrKmrOQpqO8glIBMfWCHb9cH7HOMDwCigir_xA5EUSjZNOUhe7mgJxr97GhauO85TmnhuC7W4MhDSoZIXTYPGIkP9n7IZgq9Dw4nQ3y0jxvbcTME73Dx9wHnYc1oJLMEH-eAK7d-ss-4pMAdxsjjvEs6WsLK0zn4jie_5IEBzULhvzoNE8h419oJ02xp29Z3luIx-9jjGOnLPh6xu1-Xt-dX2fXN7z_nP68zk4u6zEjmbYOyVTV2vZIgREPG1HlVItSVFB2VVSdaWRQ5JF2tWinBFEVbVrWRhPKInbz6zsE_bigu2tloaBxxIr-JukyfCXmRJ2HxKjTp0TFQr-dgHYZVC9BbQPrvloTektCg9A6QVqnu277BpnXUvVft6ch_Z3qUXQ</recordid><startdate>20041022</startdate><enddate>20041022</enddate><creator>Dillon, Thomas M</creator><creator>Bondarenko, Pavel V</creator><creator>Speed Ricci, Margaret</creator><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope></search><sort><creationdate>20041022</creationdate><title>Development of an analytical reversed-phase high-performance liquid chromatography-electrospray ionization mass spectrometry method for characterization of recombinant antibodies</title><author>Dillon, Thomas M ; Bondarenko, Pavel V ; Speed Ricci, Margaret</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c2186-e32b9a3b48adf430119ecc8276a08731de67d1b355209a384b330c55b678c3ea3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2004</creationdate><topic>Antibodies - chemistry</topic><topic>Chromatography, Gel - methods</topic><topic>Chromatography, High Pressure Liquid - methods</topic><topic>Recombinant Proteins - chemistry</topic><topic>Spectrometry, Mass, Electrospray Ionization - methods</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Dillon, Thomas M</creatorcontrib><creatorcontrib>Bondarenko, Pavel V</creatorcontrib><creatorcontrib>Speed Ricci, Margaret</creatorcontrib><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><jtitle>Journal of Chromatography A</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Dillon, Thomas M</au><au>Bondarenko, Pavel V</au><au>Speed Ricci, Margaret</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Development of an analytical reversed-phase high-performance liquid chromatography-electrospray ionization mass spectrometry method for characterization of recombinant antibodies</atitle><jtitle>Journal of Chromatography A</jtitle><addtitle>J Chromatogr A</addtitle><date>2004-10-22</date><risdate>2004</risdate><volume>1053</volume><issue>1-2</issue><spage>299</spage><epage>305</epage><pages>299-305</pages><issn>0021-9673</issn><abstract>Analytical characterization of monoclonal antibodies has been hindered by the lack of appropriate chromatographic methods to be used in conjunction with high-resolution MS. Current methodologies for standard RP-HPLC are incompatible with antibodies due to irreproducibility, low recovery, short column lifetimes, and poor resolution of degradation products. An analytical RP-HPLC-MS method was developed for monitoring and characterizing intact IgG1antibodies. Key parameters required for improved chromatographic resolution included long alkyl chains of the stationary phase (Zorbax SB300 C8), column temperatures elevated to 65-70 degrees C and combination of trifluoroacetic acid and heptafluorobutyric acid ion-pairing agents. RP chromatographic separation of degradation species and C-terminal lysine variants along with the characterization of glycosylation profile by mass spectrometry demonstrates the capability of this method for whole antibody analysis.</abstract><cop>Netherlands</cop><pmid>15543996</pmid><doi>10.1016/s0021-9673(04)01410-4</doi><tpages>7</tpages></addata></record> |
fulltext | fulltext |
identifier | ISSN: 0021-9673 |
ispartof | Journal of Chromatography A, 2004-10, Vol.1053 (1-2), p.299-305 |
issn | 0021-9673 |
language | eng |
recordid | cdi_proquest_miscellaneous_67070252 |
source | MEDLINE; Access via ScienceDirect (Elsevier) |
subjects | Antibodies - chemistry Chromatography, Gel - methods Chromatography, High Pressure Liquid - methods Recombinant Proteins - chemistry Spectrometry, Mass, Electrospray Ionization - methods |
title | Development of an analytical reversed-phase high-performance liquid chromatography-electrospray ionization mass spectrometry method for characterization of recombinant antibodies |
url | https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-22T07%3A42%3A23IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Development%20of%20an%20analytical%20reversed-phase%20high-performance%20liquid%20chromatography-electrospray%20ionization%20mass%20spectrometry%20method%20for%20characterization%20of%20recombinant%20antibodies&rft.jtitle=Journal%20of%20Chromatography%20A&rft.au=Dillon,%20Thomas%20M&rft.date=2004-10-22&rft.volume=1053&rft.issue=1-2&rft.spage=299&rft.epage=305&rft.pages=299-305&rft.issn=0021-9673&rft_id=info:doi/10.1016/s0021-9673(04)01410-4&rft_dat=%3Cproquest_cross%3E67070252%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=67070252&rft_id=info:pmid/15543996&rfr_iscdi=true |