A comparison of the mechanical performance characteristics of seven drug-eluting stent systems

Objectives: Mechanical properties of drug eluting stents (DES) will be measured to provide comparable numerical data to assess deliverability, and thus clinical performance. Background: DES are routinely used in coronary interventions to reduce the rates of restenosis and target vessel revasculariza...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Catheterization and cardiovascular interventions 2009-02, Vol.73 (3), p.350-360
Hauptverfasser: Schmidt, W., Lanzer, P., Behrens, P., Topoleski, L.D.T., Schmitz, K.-P.
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 360
container_issue 3
container_start_page 350
container_title Catheterization and cardiovascular interventions
container_volume 73
creator Schmidt, W.
Lanzer, P.
Behrens, P.
Topoleski, L.D.T.
Schmitz, K.-P.
description Objectives: Mechanical properties of drug eluting stents (DES) will be measured to provide comparable numerical data to assess deliverability, and thus clinical performance. Background: DES are routinely used in coronary interventions to reduce the rates of restenosis and target vessel revascularizations. Current research is primarily concerned with issues related to late stent thrombosis. However, mechanical properties of DES are a critical determinant of deliverability, and consequently the ultimate arbiter of their clinical performance. Methods: Mechanical properties (pushability, trackability, crossability) were measured under standardized in‐vitro conditions. The vessel models were derived from typical vessel anatomy but adapted to the individual tests. Additionally, profile and bending forces of the stent segment of the delivery system were measured. Seven different commercially available balloon‐expandable coronary DES systems were included. All stents were 3.0 mm diameter with a stent length from 14 to 18 mm. Results: The pushability expressed as the ratio of distal force at a specific proximal push force (4N) ranged between 38.66 and 18.53%. The trackability as the mean track‐forces ranged from 0.551 N to 1.137 N. One stent system could not pass this test. The mean crossing forces at a 1.4 mm stenosis model ranged from 0.038 N up to 0.103 N. The mean crimped stent profiles ranged from 1.055 mm to 1.198 mm and the bending stiffness of the crimped stent was 17.22 to 47.20 Nmm2. Conclusion: Better understanding of mechanical properties of DES shall improve tactile skills of the interventionists during PCI and to improve criteria for DES selection in specific clinical settings. © 2008 Wiley‐Liss, Inc.
doi_str_mv 10.1002/ccd.21832
format Article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_66940950</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>66940950</sourcerecordid><originalsourceid>FETCH-LOGICAL-c3612-e349876871dd877843b87f9204cd6fd5f2c1c9b77965f1007c23f8de3098a54d3</originalsourceid><addsrcrecordid>eNp1kElPHDEQRq0IFJbkkD-AfIrEoQcv3V6OaFijUSIlIHKK5bHL0KSXwe4G5t_jyQzkxKlKpfd9Uj2EvlAyoYSwI-f8hFHF2Qe0SyvGCsnE763NTnUpdtBeSveEEC2Y_oh2qCaq0lTuoj_H2PXtwsY69R3uAx7uALfg7mxXO9vgBcTQx9Z2DnA-RusGyOxQu7SiEzxCh30cbwtoxqHubnEaoBtwWubZpk9oO9gmwefN3EfXZ6dX04ti9uP8cno8KxwXlBXAS62kUJJ6r6RUJZ8rGTQjpfMi-CowR52eS6lFFfLL0jEelAdOtLJV6fk--rruXcT-YYQ0mLZODprGdtCPyQihS6IrksHDNehin1KEYBaxbm1cGkrMSqbJMs0_mZk92JSO8xb8f3JjLwNHa-CpbmD5fpOZTk9eK4t1IiuE57eEjX-NkFxW5ub7uZn9PFNX336VhvAXFyuNtA</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>66940950</pqid></control><display><type>article</type><title>A comparison of the mechanical performance characteristics of seven drug-eluting stent systems</title><source>MEDLINE</source><source>Wiley Online Library All Journals</source><creator>Schmidt, W. ; Lanzer, P. ; Behrens, P. ; Topoleski, L.D.T. ; Schmitz, K.-P.</creator><creatorcontrib>Schmidt, W. ; Lanzer, P. ; Behrens, P. ; Topoleski, L.D.T. ; Schmitz, K.-P.</creatorcontrib><description>Objectives: Mechanical properties of drug eluting stents (DES) will be measured to provide comparable numerical data to assess deliverability, and thus clinical performance. Background: DES are routinely used in coronary interventions to reduce the rates of restenosis and target vessel revascularizations. Current research is primarily concerned with issues related to late stent thrombosis. However, mechanical properties of DES are a critical determinant of deliverability, and consequently the ultimate arbiter of their clinical performance. Methods: Mechanical properties (pushability, trackability, crossability) were measured under standardized in‐vitro conditions. The vessel models were derived from typical vessel anatomy but adapted to the individual tests. Additionally, profile and bending forces of the stent segment of the delivery system were measured. Seven different commercially available balloon‐expandable coronary DES systems were included. All stents were 3.0 mm diameter with a stent length from 14 to 18 mm. Results: The pushability expressed as the ratio of distal force at a specific proximal push force (4N) ranged between 38.66 and 18.53%. The trackability as the mean track‐forces ranged from 0.551 N to 1.137 N. One stent system could not pass this test. The mean crossing forces at a 1.4 mm stenosis model ranged from 0.038 N up to 0.103 N. The mean crimped stent profiles ranged from 1.055 mm to 1.198 mm and the bending stiffness of the crimped stent was 17.22 to 47.20 Nmm2. Conclusion: Better understanding of mechanical properties of DES shall improve tactile skills of the interventionists during PCI and to improve criteria for DES selection in specific clinical settings. © 2008 Wiley‐Liss, Inc.</description><identifier>ISSN: 1522-1946</identifier><identifier>EISSN: 1522-726X</identifier><identifier>DOI: 10.1002/ccd.21832</identifier><identifier>PMID: 19085917</identifier><language>eng</language><publisher>Hoboken: Wiley Subscription Services, Inc., A Wiley Company</publisher><subject>Angioplasty, Balloon - instrumentation ; Biomechanical Phenomena ; clinical impact ; Drug-Eluting Stents ; Elasticity ; Humans ; In Vitro Techniques ; invasive cardiology ; Materials Testing ; Mathematics ; mechanical performance ; Radiology, Interventional ; Stress, Mechanical</subject><ispartof>Catheterization and cardiovascular interventions, 2009-02, Vol.73 (3), p.350-360</ispartof><rights>Copyright © 2008 Wiley‐Liss, Inc.</rights><rights>Copyright 2009 Wiley-Liss, Inc.</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c3612-e349876871dd877843b87f9204cd6fd5f2c1c9b77965f1007c23f8de3098a54d3</citedby><cites>FETCH-LOGICAL-c3612-e349876871dd877843b87f9204cd6fd5f2c1c9b77965f1007c23f8de3098a54d3</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktopdf>$$Uhttps://onlinelibrary.wiley.com/doi/pdf/10.1002%2Fccd.21832$$EPDF$$P50$$Gwiley$$H</linktopdf><linktohtml>$$Uhttps://onlinelibrary.wiley.com/doi/full/10.1002%2Fccd.21832$$EHTML$$P50$$Gwiley$$H</linktohtml><link.rule.ids>314,780,784,1417,27924,27925,45574,45575</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/19085917$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Schmidt, W.</creatorcontrib><creatorcontrib>Lanzer, P.</creatorcontrib><creatorcontrib>Behrens, P.</creatorcontrib><creatorcontrib>Topoleski, L.D.T.</creatorcontrib><creatorcontrib>Schmitz, K.-P.</creatorcontrib><title>A comparison of the mechanical performance characteristics of seven drug-eluting stent systems</title><title>Catheterization and cardiovascular interventions</title><addtitle>Cathet. Cardiovasc. Intervent</addtitle><description>Objectives: Mechanical properties of drug eluting stents (DES) will be measured to provide comparable numerical data to assess deliverability, and thus clinical performance. Background: DES are routinely used in coronary interventions to reduce the rates of restenosis and target vessel revascularizations. Current research is primarily concerned with issues related to late stent thrombosis. However, mechanical properties of DES are a critical determinant of deliverability, and consequently the ultimate arbiter of their clinical performance. Methods: Mechanical properties (pushability, trackability, crossability) were measured under standardized in‐vitro conditions. The vessel models were derived from typical vessel anatomy but adapted to the individual tests. Additionally, profile and bending forces of the stent segment of the delivery system were measured. Seven different commercially available balloon‐expandable coronary DES systems were included. All stents were 3.0 mm diameter with a stent length from 14 to 18 mm. Results: The pushability expressed as the ratio of distal force at a specific proximal push force (4N) ranged between 38.66 and 18.53%. The trackability as the mean track‐forces ranged from 0.551 N to 1.137 N. One stent system could not pass this test. The mean crossing forces at a 1.4 mm stenosis model ranged from 0.038 N up to 0.103 N. The mean crimped stent profiles ranged from 1.055 mm to 1.198 mm and the bending stiffness of the crimped stent was 17.22 to 47.20 Nmm2. Conclusion: Better understanding of mechanical properties of DES shall improve tactile skills of the interventionists during PCI and to improve criteria for DES selection in specific clinical settings. © 2008 Wiley‐Liss, Inc.</description><subject>Angioplasty, Balloon - instrumentation</subject><subject>Biomechanical Phenomena</subject><subject>clinical impact</subject><subject>Drug-Eluting Stents</subject><subject>Elasticity</subject><subject>Humans</subject><subject>In Vitro Techniques</subject><subject>invasive cardiology</subject><subject>Materials Testing</subject><subject>Mathematics</subject><subject>mechanical performance</subject><subject>Radiology, Interventional</subject><subject>Stress, Mechanical</subject><issn>1522-1946</issn><issn>1522-726X</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2009</creationdate><recordtype>article</recordtype><sourceid>EIF</sourceid><recordid>eNp1kElPHDEQRq0IFJbkkD-AfIrEoQcv3V6OaFijUSIlIHKK5bHL0KSXwe4G5t_jyQzkxKlKpfd9Uj2EvlAyoYSwI-f8hFHF2Qe0SyvGCsnE763NTnUpdtBeSveEEC2Y_oh2qCaq0lTuoj_H2PXtwsY69R3uAx7uALfg7mxXO9vgBcTQx9Z2DnA-RusGyOxQu7SiEzxCh30cbwtoxqHubnEaoBtwWubZpk9oO9gmwefN3EfXZ6dX04ti9uP8cno8KxwXlBXAS62kUJJ6r6RUJZ8rGTQjpfMi-CowR52eS6lFFfLL0jEelAdOtLJV6fk--rruXcT-YYQ0mLZODprGdtCPyQihS6IrksHDNehin1KEYBaxbm1cGkrMSqbJMs0_mZk92JSO8xb8f3JjLwNHa-CpbmD5fpOZTk9eK4t1IiuE57eEjX-NkFxW5ub7uZn9PFNX336VhvAXFyuNtA</recordid><startdate>20090215</startdate><enddate>20090215</enddate><creator>Schmidt, W.</creator><creator>Lanzer, P.</creator><creator>Behrens, P.</creator><creator>Topoleski, L.D.T.</creator><creator>Schmitz, K.-P.</creator><general>Wiley Subscription Services, Inc., A Wiley Company</general><scope>BSCLL</scope><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope></search><sort><creationdate>20090215</creationdate><title>A comparison of the mechanical performance characteristics of seven drug-eluting stent systems</title><author>Schmidt, W. ; Lanzer, P. ; Behrens, P. ; Topoleski, L.D.T. ; Schmitz, K.-P.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c3612-e349876871dd877843b87f9204cd6fd5f2c1c9b77965f1007c23f8de3098a54d3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2009</creationdate><topic>Angioplasty, Balloon - instrumentation</topic><topic>Biomechanical Phenomena</topic><topic>clinical impact</topic><topic>Drug-Eluting Stents</topic><topic>Elasticity</topic><topic>Humans</topic><topic>In Vitro Techniques</topic><topic>invasive cardiology</topic><topic>Materials Testing</topic><topic>Mathematics</topic><topic>mechanical performance</topic><topic>Radiology, Interventional</topic><topic>Stress, Mechanical</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Schmidt, W.</creatorcontrib><creatorcontrib>Lanzer, P.</creatorcontrib><creatorcontrib>Behrens, P.</creatorcontrib><creatorcontrib>Topoleski, L.D.T.</creatorcontrib><creatorcontrib>Schmitz, K.-P.</creatorcontrib><collection>Istex</collection><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><jtitle>Catheterization and cardiovascular interventions</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Schmidt, W.</au><au>Lanzer, P.</au><au>Behrens, P.</au><au>Topoleski, L.D.T.</au><au>Schmitz, K.-P.</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>A comparison of the mechanical performance characteristics of seven drug-eluting stent systems</atitle><jtitle>Catheterization and cardiovascular interventions</jtitle><addtitle>Cathet. Cardiovasc. Intervent</addtitle><date>2009-02-15</date><risdate>2009</risdate><volume>73</volume><issue>3</issue><spage>350</spage><epage>360</epage><pages>350-360</pages><issn>1522-1946</issn><eissn>1522-726X</eissn><abstract>Objectives: Mechanical properties of drug eluting stents (DES) will be measured to provide comparable numerical data to assess deliverability, and thus clinical performance. Background: DES are routinely used in coronary interventions to reduce the rates of restenosis and target vessel revascularizations. Current research is primarily concerned with issues related to late stent thrombosis. However, mechanical properties of DES are a critical determinant of deliverability, and consequently the ultimate arbiter of their clinical performance. Methods: Mechanical properties (pushability, trackability, crossability) were measured under standardized in‐vitro conditions. The vessel models were derived from typical vessel anatomy but adapted to the individual tests. Additionally, profile and bending forces of the stent segment of the delivery system were measured. Seven different commercially available balloon‐expandable coronary DES systems were included. All stents were 3.0 mm diameter with a stent length from 14 to 18 mm. Results: The pushability expressed as the ratio of distal force at a specific proximal push force (4N) ranged between 38.66 and 18.53%. The trackability as the mean track‐forces ranged from 0.551 N to 1.137 N. One stent system could not pass this test. The mean crossing forces at a 1.4 mm stenosis model ranged from 0.038 N up to 0.103 N. The mean crimped stent profiles ranged from 1.055 mm to 1.198 mm and the bending stiffness of the crimped stent was 17.22 to 47.20 Nmm2. Conclusion: Better understanding of mechanical properties of DES shall improve tactile skills of the interventionists during PCI and to improve criteria for DES selection in specific clinical settings. © 2008 Wiley‐Liss, Inc.</abstract><cop>Hoboken</cop><pub>Wiley Subscription Services, Inc., A Wiley Company</pub><pmid>19085917</pmid><doi>10.1002/ccd.21832</doi><tpages>11</tpages></addata></record>
fulltext fulltext
identifier ISSN: 1522-1946
ispartof Catheterization and cardiovascular interventions, 2009-02, Vol.73 (3), p.350-360
issn 1522-1946
1522-726X
language eng
recordid cdi_proquest_miscellaneous_66940950
source MEDLINE; Wiley Online Library All Journals
subjects Angioplasty, Balloon - instrumentation
Biomechanical Phenomena
clinical impact
Drug-Eluting Stents
Elasticity
Humans
In Vitro Techniques
invasive cardiology
Materials Testing
Mathematics
mechanical performance
Radiology, Interventional
Stress, Mechanical
title A comparison of the mechanical performance characteristics of seven drug-eluting stent systems
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-08T01%3A39%3A13IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=A%20comparison%20of%20the%20mechanical%20performance%20characteristics%20of%20seven%20drug-eluting%20stent%20systems&rft.jtitle=Catheterization%20and%20cardiovascular%20interventions&rft.au=Schmidt,%20W.&rft.date=2009-02-15&rft.volume=73&rft.issue=3&rft.spage=350&rft.epage=360&rft.pages=350-360&rft.issn=1522-1946&rft.eissn=1522-726X&rft_id=info:doi/10.1002/ccd.21832&rft_dat=%3Cproquest_cross%3E66940950%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=66940950&rft_id=info:pmid/19085917&rfr_iscdi=true