Fatigue analysis of interference EMG signals obtained from biceps brachii during isometric voluntary contraction at various force levels
Abstract The aim of the present study was to test the applicability of indices of muscle fatigue to interference EMG signals detected at various distances from the end-plate region during isometric voluntary contractions at different force levels. Bar electrode with 12 leading off surfaces and 5 mm...
Gespeichert in:
Veröffentlicht in: | Journal of electromyography and kinesiology 2009-04, Vol.19 (2), p.252-258 |
---|---|
Hauptverfasser: | , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
container_end_page | 258 |
---|---|
container_issue | 2 |
container_start_page | 252 |
container_title | Journal of electromyography and kinesiology |
container_volume | 19 |
creator | Dimitrova, N.A Arabadzhiev, T.I Hogrel, J.-Y Dimitrov, G.V |
description | Abstract The aim of the present study was to test the applicability of indices of muscle fatigue to interference EMG signals detected at various distances from the end-plate region during isometric voluntary contractions at different force levels. Bar electrode with 12 leading off surfaces and 5 mm inter-pole distance was used to detect EMG from human m. biceps brachii . The sensitivity of the new spectral indices to detect muscle fatigue was higher than that of mean or median frequencies. Considerable variations in the characteristic frequencies and values of spectral indices that could reflect recruitment and/or rotation of MUs were found under submaximal efforts. The increase of the indices was considered as a sign of peripheral muscle fatigue while their decreasing could be a sign of de-recruitment of fatigued or/and recruitment of new MUs reflecting central fatigue. The sensitivity of the indices to fatigue depended on the electrode arrangement and its longitudinal position in respect of the end-plate region and ends of the muscle fibres. It was larger for the electrodes placed in the middle of the semi-fibre. To overcome the problem with inappropriate position of the electrode, one could use an electrode whose longitudinal dimension would cover the entire semi-length of the analyzed fibres. |
doi_str_mv | 10.1016/j.jelekin.2007.08.007 |
format | Article |
fullrecord | <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_66899655</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><els_id>S1050641107001459</els_id><sourcerecordid>20384718</sourcerecordid><originalsourceid>FETCH-LOGICAL-c515t-f2a2a2ab699083f4f5830b07a3351ea6ffba9c21d9bda34c0958684f984da2413</originalsourceid><addsrcrecordid>eNqFUsFu1DAQjRCIlsIngHzilmDHceJcQKhqC1IRB-BsOc54mTSxF9tZaf-gn42jXQmJS-XDszRv5o39XlG8ZbRilLUfpmqCGR7QVTWlXUVlleFZcclkx0vRMfY836mgZdswdlG8inGilHVU0pfFBet6zqRsL4vHW51wtwLRTs_HiJF4S9AlCBYCOAPk5tsdibjL5VwbkkYHI7HBL2RAA_tIhqDNb0QyrgHdjmD0C6SAhhz8vLqkw5EY71JmJfSO6EQOOqBfI7E-ZIEZDjDH18ULmyXgzRmvil-3Nz-vv5T33---Xn--L41gIpW21tsZ2r6nktvGCsnpQDvNuWCgW2sH3Zuajf0wat4Y2gvZysb2shl13TB-Vbw_zd0H_2eFmNSC0cA8awd5J9W2su9bIZ4k1pTLpmMyE8WJaIKPMYBV-4BLfrZiVG1eqUmdvVKbV4pKlSH3vTsLrMMC47-uszmZ8OlEyN8DB4SgosHNkxEDmKRGj09KfPxvgpnRodHzAxwhTn4Nm6-KqVgrqn5sgdnyQruclUb0_C8Xa7_P</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>20384718</pqid></control><display><type>article</type><title>Fatigue analysis of interference EMG signals obtained from biceps brachii during isometric voluntary contraction at various force levels</title><source>MEDLINE</source><source>Access via ScienceDirect (Elsevier)</source><creator>Dimitrova, N.A ; Arabadzhiev, T.I ; Hogrel, J.-Y ; Dimitrov, G.V</creator><creatorcontrib>Dimitrova, N.A ; Arabadzhiev, T.I ; Hogrel, J.-Y ; Dimitrov, G.V</creatorcontrib><description>Abstract The aim of the present study was to test the applicability of indices of muscle fatigue to interference EMG signals detected at various distances from the end-plate region during isometric voluntary contractions at different force levels. Bar electrode with 12 leading off surfaces and 5 mm inter-pole distance was used to detect EMG from human m. biceps brachii . The sensitivity of the new spectral indices to detect muscle fatigue was higher than that of mean or median frequencies. Considerable variations in the characteristic frequencies and values of spectral indices that could reflect recruitment and/or rotation of MUs were found under submaximal efforts. The increase of the indices was considered as a sign of peripheral muscle fatigue while their decreasing could be a sign of de-recruitment of fatigued or/and recruitment of new MUs reflecting central fatigue. The sensitivity of the indices to fatigue depended on the electrode arrangement and its longitudinal position in respect of the end-plate region and ends of the muscle fibres. It was larger for the electrodes placed in the middle of the semi-fibre. To overcome the problem with inappropriate position of the electrode, one could use an electrode whose longitudinal dimension would cover the entire semi-length of the analyzed fibres.</description><identifier>ISSN: 1050-6411</identifier><identifier>EISSN: 1873-5711</identifier><identifier>DOI: 10.1016/j.jelekin.2007.08.007</identifier><identifier>PMID: 17931886</identifier><language>eng</language><publisher>England: Elsevier Ltd</publisher><subject>Adult ; Algorithms ; Arm - physiology ; Central factors ; Electromyography - methods ; Female ; Humans ; Interference EMG ; Isometric contraction ; Isometric Contraction - physiology ; Longitudinal electrode position ; Male ; Muscle fatigue ; Muscle Fatigue - physiology ; Muscle, Skeletal - physiology ; Peripheral factors ; Physical Endurance - physiology ; Physical Medicine and Rehabilitation ; Reproducibility of Results ; Sensitivity and Specificity ; Spectral indices ; Volition - physiology</subject><ispartof>Journal of electromyography and kinesiology, 2009-04, Vol.19 (2), p.252-258</ispartof><rights>Elsevier Ltd</rights><rights>2007 Elsevier Ltd</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c515t-f2a2a2ab699083f4f5830b07a3351ea6ffba9c21d9bda34c0958684f984da2413</citedby><cites>FETCH-LOGICAL-c515t-f2a2a2ab699083f4f5830b07a3351ea6ffba9c21d9bda34c0958684f984da2413</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://dx.doi.org/10.1016/j.jelekin.2007.08.007$$EHTML$$P50$$Gelsevier$$H</linktohtml><link.rule.ids>314,780,784,3550,27924,27925,45995</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/17931886$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Dimitrova, N.A</creatorcontrib><creatorcontrib>Arabadzhiev, T.I</creatorcontrib><creatorcontrib>Hogrel, J.-Y</creatorcontrib><creatorcontrib>Dimitrov, G.V</creatorcontrib><title>Fatigue analysis of interference EMG signals obtained from biceps brachii during isometric voluntary contraction at various force levels</title><title>Journal of electromyography and kinesiology</title><addtitle>J Electromyogr Kinesiol</addtitle><description>Abstract The aim of the present study was to test the applicability of indices of muscle fatigue to interference EMG signals detected at various distances from the end-plate region during isometric voluntary contractions at different force levels. Bar electrode with 12 leading off surfaces and 5 mm inter-pole distance was used to detect EMG from human m. biceps brachii . The sensitivity of the new spectral indices to detect muscle fatigue was higher than that of mean or median frequencies. Considerable variations in the characteristic frequencies and values of spectral indices that could reflect recruitment and/or rotation of MUs were found under submaximal efforts. The increase of the indices was considered as a sign of peripheral muscle fatigue while their decreasing could be a sign of de-recruitment of fatigued or/and recruitment of new MUs reflecting central fatigue. The sensitivity of the indices to fatigue depended on the electrode arrangement and its longitudinal position in respect of the end-plate region and ends of the muscle fibres. It was larger for the electrodes placed in the middle of the semi-fibre. To overcome the problem with inappropriate position of the electrode, one could use an electrode whose longitudinal dimension would cover the entire semi-length of the analyzed fibres.</description><subject>Adult</subject><subject>Algorithms</subject><subject>Arm - physiology</subject><subject>Central factors</subject><subject>Electromyography - methods</subject><subject>Female</subject><subject>Humans</subject><subject>Interference EMG</subject><subject>Isometric contraction</subject><subject>Isometric Contraction - physiology</subject><subject>Longitudinal electrode position</subject><subject>Male</subject><subject>Muscle fatigue</subject><subject>Muscle Fatigue - physiology</subject><subject>Muscle, Skeletal - physiology</subject><subject>Peripheral factors</subject><subject>Physical Endurance - physiology</subject><subject>Physical Medicine and Rehabilitation</subject><subject>Reproducibility of Results</subject><subject>Sensitivity and Specificity</subject><subject>Spectral indices</subject><subject>Volition - physiology</subject><issn>1050-6411</issn><issn>1873-5711</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2009</creationdate><recordtype>article</recordtype><sourceid>EIF</sourceid><recordid>eNqFUsFu1DAQjRCIlsIngHzilmDHceJcQKhqC1IRB-BsOc54mTSxF9tZaf-gn42jXQmJS-XDszRv5o39XlG8ZbRilLUfpmqCGR7QVTWlXUVlleFZcclkx0vRMfY836mgZdswdlG8inGilHVU0pfFBet6zqRsL4vHW51wtwLRTs_HiJF4S9AlCBYCOAPk5tsdibjL5VwbkkYHI7HBL2RAA_tIhqDNb0QyrgHdjmD0C6SAhhz8vLqkw5EY71JmJfSO6EQOOqBfI7E-ZIEZDjDH18ULmyXgzRmvil-3Nz-vv5T33---Xn--L41gIpW21tsZ2r6nktvGCsnpQDvNuWCgW2sH3Zuajf0wat4Y2gvZysb2shl13TB-Vbw_zd0H_2eFmNSC0cA8awd5J9W2su9bIZ4k1pTLpmMyE8WJaIKPMYBV-4BLfrZiVG1eqUmdvVKbV4pKlSH3vTsLrMMC47-uszmZ8OlEyN8DB4SgosHNkxEDmKRGj09KfPxvgpnRodHzAxwhTn4Nm6-KqVgrqn5sgdnyQruclUb0_C8Xa7_P</recordid><startdate>20090401</startdate><enddate>20090401</enddate><creator>Dimitrova, N.A</creator><creator>Arabadzhiev, T.I</creator><creator>Hogrel, J.-Y</creator><creator>Dimitrov, G.V</creator><general>Elsevier Ltd</general><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7TS</scope><scope>7X8</scope></search><sort><creationdate>20090401</creationdate><title>Fatigue analysis of interference EMG signals obtained from biceps brachii during isometric voluntary contraction at various force levels</title><author>Dimitrova, N.A ; Arabadzhiev, T.I ; Hogrel, J.-Y ; Dimitrov, G.V</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c515t-f2a2a2ab699083f4f5830b07a3351ea6ffba9c21d9bda34c0958684f984da2413</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2009</creationdate><topic>Adult</topic><topic>Algorithms</topic><topic>Arm - physiology</topic><topic>Central factors</topic><topic>Electromyography - methods</topic><topic>Female</topic><topic>Humans</topic><topic>Interference EMG</topic><topic>Isometric contraction</topic><topic>Isometric Contraction - physiology</topic><topic>Longitudinal electrode position</topic><topic>Male</topic><topic>Muscle fatigue</topic><topic>Muscle Fatigue - physiology</topic><topic>Muscle, Skeletal - physiology</topic><topic>Peripheral factors</topic><topic>Physical Endurance - physiology</topic><topic>Physical Medicine and Rehabilitation</topic><topic>Reproducibility of Results</topic><topic>Sensitivity and Specificity</topic><topic>Spectral indices</topic><topic>Volition - physiology</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Dimitrova, N.A</creatorcontrib><creatorcontrib>Arabadzhiev, T.I</creatorcontrib><creatorcontrib>Hogrel, J.-Y</creatorcontrib><creatorcontrib>Dimitrov, G.V</creatorcontrib><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>Physical Education Index</collection><collection>MEDLINE - Academic</collection><jtitle>Journal of electromyography and kinesiology</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Dimitrova, N.A</au><au>Arabadzhiev, T.I</au><au>Hogrel, J.-Y</au><au>Dimitrov, G.V</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Fatigue analysis of interference EMG signals obtained from biceps brachii during isometric voluntary contraction at various force levels</atitle><jtitle>Journal of electromyography and kinesiology</jtitle><addtitle>J Electromyogr Kinesiol</addtitle><date>2009-04-01</date><risdate>2009</risdate><volume>19</volume><issue>2</issue><spage>252</spage><epage>258</epage><pages>252-258</pages><issn>1050-6411</issn><eissn>1873-5711</eissn><abstract>Abstract The aim of the present study was to test the applicability of indices of muscle fatigue to interference EMG signals detected at various distances from the end-plate region during isometric voluntary contractions at different force levels. Bar electrode with 12 leading off surfaces and 5 mm inter-pole distance was used to detect EMG from human m. biceps brachii . The sensitivity of the new spectral indices to detect muscle fatigue was higher than that of mean or median frequencies. Considerable variations in the characteristic frequencies and values of spectral indices that could reflect recruitment and/or rotation of MUs were found under submaximal efforts. The increase of the indices was considered as a sign of peripheral muscle fatigue while their decreasing could be a sign of de-recruitment of fatigued or/and recruitment of new MUs reflecting central fatigue. The sensitivity of the indices to fatigue depended on the electrode arrangement and its longitudinal position in respect of the end-plate region and ends of the muscle fibres. It was larger for the electrodes placed in the middle of the semi-fibre. To overcome the problem with inappropriate position of the electrode, one could use an electrode whose longitudinal dimension would cover the entire semi-length of the analyzed fibres.</abstract><cop>England</cop><pub>Elsevier Ltd</pub><pmid>17931886</pmid><doi>10.1016/j.jelekin.2007.08.007</doi><tpages>7</tpages></addata></record> |
fulltext | fulltext |
identifier | ISSN: 1050-6411 |
ispartof | Journal of electromyography and kinesiology, 2009-04, Vol.19 (2), p.252-258 |
issn | 1050-6411 1873-5711 |
language | eng |
recordid | cdi_proquest_miscellaneous_66899655 |
source | MEDLINE; Access via ScienceDirect (Elsevier) |
subjects | Adult Algorithms Arm - physiology Central factors Electromyography - methods Female Humans Interference EMG Isometric contraction Isometric Contraction - physiology Longitudinal electrode position Male Muscle fatigue Muscle Fatigue - physiology Muscle, Skeletal - physiology Peripheral factors Physical Endurance - physiology Physical Medicine and Rehabilitation Reproducibility of Results Sensitivity and Specificity Spectral indices Volition - physiology |
title | Fatigue analysis of interference EMG signals obtained from biceps brachii during isometric voluntary contraction at various force levels |
url | https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-19T05%3A19%3A18IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Fatigue%20analysis%20of%20interference%20EMG%20signals%20obtained%20from%20biceps%20brachii%20during%20isometric%20voluntary%20contraction%20at%20various%20force%20levels&rft.jtitle=Journal%20of%20electromyography%20and%20kinesiology&rft.au=Dimitrova,%20N.A&rft.date=2009-04-01&rft.volume=19&rft.issue=2&rft.spage=252&rft.epage=258&rft.pages=252-258&rft.issn=1050-6411&rft.eissn=1873-5711&rft_id=info:doi/10.1016/j.jelekin.2007.08.007&rft_dat=%3Cproquest_cross%3E20384718%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=20384718&rft_id=info:pmid/17931886&rft_els_id=S1050641107001459&rfr_iscdi=true |