Torque capacity of metal and polycarbonate brackets with and without a metal slot
The aim of the present study was to investigate slot deformation and the equivalent torque capacity of polycarbonate brackets with and without a metal slot in comparison with those of a metal bracket. For this purpose, the expansion characteristics and, in a further investigation, the labial crown t...
Gespeichert in:
Veröffentlicht in: | European journal of orthodontics 2004-08, Vol.26 (4), p.435-441 |
---|---|
Hauptverfasser: | , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
container_end_page | 441 |
---|---|
container_issue | 4 |
container_start_page | 435 |
container_title | European journal of orthodontics |
container_volume | 26 |
creator | Harzer, Winfried Bourauel, Christoph Gmyrek, Henner |
description | The aim of the present study was to investigate slot deformation and the equivalent torque capacity of polycarbonate brackets with and without a metal slot in comparison with those of a metal bracket. For this purpose, the expansion characteristics and, in a further investigation, the labial crown torque of an upper central incisor, were measured in a simulated intra-oral clinical situation, using the orthodontic measuring and simulation system (OMSS). Three types of bracket with a 0.018 inch slot were tested: polycarbonate Brillant® without a metal slot, Elegance® with a metal slot and the metal bracket, Mini-Mono®. For testing purposes the brackets were torqued with 0.016 × 0.022 inch (0.41 × 0.56 mm) and 0.018 × 0.022 inch (0.46 × 0.56 mm) ideal stainless steel archwires. In the activating experiments, significantly higher torque losses and lower torquing moments were registered with both rectangular archwires with the polycarbonate brackets than with the metal bracket. In the simulation tests, significantly higher torquing moments were registered with the metal bracket than with the polycarbonate brackets. The values for the Elegance® bracket were between those of the Mini-Mono® and Brillant® brackets. The OMSS model approximates the clinical situation, with the torque loss being notably higher than in the in vitro activating experiments. This is due to the adjacent teeth giving the archwire additional play. In addition, the torquing process may twist the archwire, resulting in subsidiary forces. On the basis of the present results, all three brackets can be recommended for torquing. However, in view of the high torque losses, the torques programmed in the straightwire technique must be seen as questionable. Data should be provided by the manufacturer on the bending to be expected in polycarbonate brackets, which has to be offset by additional torque, or the bracket torque should be omitted from the technical specifications. |
doi_str_mv | 10.1093/ejo/26.4.435 |
format | Article |
fullrecord | <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_66873413</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>66873413</sourcerecordid><originalsourceid>FETCH-LOGICAL-c390t-1ed17d88856438ca0e2f49728dc7dc462aa96bc0b92ac7efe9b5dbded81c88613</originalsourceid><addsrcrecordid>eNpdkE1rGzEQhkVJaRy3t57LkkNPWWf0sfo4hpAmAUNocYvxRWglLV1nbTmSlsT_Ppt4SSCnGZhnXmYehL5jmGFQ9NyvwznhMzZjtPqEJphxKAnBcIQmgBkuKyrFMTpJaQ0AVDLxBR3jinJOpZqg34sQH3pfWLMzts37IjTFxmfTFWbril3o9tbEOmxN9kUdjb33ORWPbf7_On9pQp8LM-6kLuSv6HNjuuS_jXWK_v66WlzelPO769vLi3lpqYJcYu-wcFLKijMqrQFPGqYEkc4KZxknxiheW6gVMVb4xqu6crXzTmIrJcd0in4ecncxDB-krDdtsr7rzNaHPmnOpaAM0wE8_QCuQx-3w22agALgCuQAnR0gG0NK0Td6F9uNiXuNQb941oNnTbhmevA84D_GzL7eePcOj2IHoDwAbcr-6W1u4r3mgopK3yxXeoE5kNWfpf5HnwFy0oh_</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>209006908</pqid></control><display><type>article</type><title>Torque capacity of metal and polycarbonate brackets with and without a metal slot</title><source>MEDLINE</source><source>Elektronische Zeitschriftenbibliothek - Frei zugängliche E-Journals</source><source>Oxford University Press Journals All Titles (1996-Current)</source><creator>Harzer, Winfried ; Bourauel, Christoph ; Gmyrek, Henner</creator><creatorcontrib>Harzer, Winfried ; Bourauel, Christoph ; Gmyrek, Henner</creatorcontrib><description>The aim of the present study was to investigate slot deformation and the equivalent torque capacity of polycarbonate brackets with and without a metal slot in comparison with those of a metal bracket. For this purpose, the expansion characteristics and, in a further investigation, the labial crown torque of an upper central incisor, were measured in a simulated intra-oral clinical situation, using the orthodontic measuring and simulation system (OMSS). Three types of bracket with a 0.018 inch slot were tested: polycarbonate Brillant® without a metal slot, Elegance® with a metal slot and the metal bracket, Mini-Mono®. For testing purposes the brackets were torqued with 0.016 × 0.022 inch (0.41 × 0.56 mm) and 0.018 × 0.022 inch (0.46 × 0.56 mm) ideal stainless steel archwires. In the activating experiments, significantly higher torque losses and lower torquing moments were registered with both rectangular archwires with the polycarbonate brackets than with the metal bracket. In the simulation tests, significantly higher torquing moments were registered with the metal bracket than with the polycarbonate brackets. The values for the Elegance® bracket were between those of the Mini-Mono® and Brillant® brackets. The OMSS model approximates the clinical situation, with the torque loss being notably higher than in the in vitro activating experiments. This is due to the adjacent teeth giving the archwire additional play. In addition, the torquing process may twist the archwire, resulting in subsidiary forces. On the basis of the present results, all three brackets can be recommended for torquing. However, in view of the high torque losses, the torques programmed in the straightwire technique must be seen as questionable. Data should be provided by the manufacturer on the bending to be expected in polycarbonate brackets, which has to be offset by additional torque, or the bracket torque should be omitted from the technical specifications.</description><identifier>ISSN: 0141-5387</identifier><identifier>EISSN: 1460-2210</identifier><identifier>DOI: 10.1093/ejo/26.4.435</identifier><identifier>PMID: 15366389</identifier><identifier>CODEN: EJOODK</identifier><language>eng</language><publisher>England: Oxford University Press</publisher><subject>Dental Alloys - chemistry ; Dentistry ; Humans ; Incisor ; Materials Testing ; Orthodontic Appliance Design ; Orthodontic Brackets ; Polymers - chemistry ; Stainless Steel - chemistry ; Stress, Mechanical ; Surface Properties ; Torque ; Transducers</subject><ispartof>European journal of orthodontics, 2004-08, Vol.26 (4), p.435-441</ispartof><rights>Copyright Oxford University Press(England) Aug 2004</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c390t-1ed17d88856438ca0e2f49728dc7dc462aa96bc0b92ac7efe9b5dbded81c88613</citedby></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,777,781,27905,27906</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/15366389$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Harzer, Winfried</creatorcontrib><creatorcontrib>Bourauel, Christoph</creatorcontrib><creatorcontrib>Gmyrek, Henner</creatorcontrib><title>Torque capacity of metal and polycarbonate brackets with and without a metal slot</title><title>European journal of orthodontics</title><addtitle>Eur J Orthod</addtitle><description>The aim of the present study was to investigate slot deformation and the equivalent torque capacity of polycarbonate brackets with and without a metal slot in comparison with those of a metal bracket. For this purpose, the expansion characteristics and, in a further investigation, the labial crown torque of an upper central incisor, were measured in a simulated intra-oral clinical situation, using the orthodontic measuring and simulation system (OMSS). Three types of bracket with a 0.018 inch slot were tested: polycarbonate Brillant® without a metal slot, Elegance® with a metal slot and the metal bracket, Mini-Mono®. For testing purposes the brackets were torqued with 0.016 × 0.022 inch (0.41 × 0.56 mm) and 0.018 × 0.022 inch (0.46 × 0.56 mm) ideal stainless steel archwires. In the activating experiments, significantly higher torque losses and lower torquing moments were registered with both rectangular archwires with the polycarbonate brackets than with the metal bracket. In the simulation tests, significantly higher torquing moments were registered with the metal bracket than with the polycarbonate brackets. The values for the Elegance® bracket were between those of the Mini-Mono® and Brillant® brackets. The OMSS model approximates the clinical situation, with the torque loss being notably higher than in the in vitro activating experiments. This is due to the adjacent teeth giving the archwire additional play. In addition, the torquing process may twist the archwire, resulting in subsidiary forces. On the basis of the present results, all three brackets can be recommended for torquing. However, in view of the high torque losses, the torques programmed in the straightwire technique must be seen as questionable. Data should be provided by the manufacturer on the bending to be expected in polycarbonate brackets, which has to be offset by additional torque, or the bracket torque should be omitted from the technical specifications.</description><subject>Dental Alloys - chemistry</subject><subject>Dentistry</subject><subject>Humans</subject><subject>Incisor</subject><subject>Materials Testing</subject><subject>Orthodontic Appliance Design</subject><subject>Orthodontic Brackets</subject><subject>Polymers - chemistry</subject><subject>Stainless Steel - chemistry</subject><subject>Stress, Mechanical</subject><subject>Surface Properties</subject><subject>Torque</subject><subject>Transducers</subject><issn>0141-5387</issn><issn>1460-2210</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2004</creationdate><recordtype>article</recordtype><sourceid>EIF</sourceid><recordid>eNpdkE1rGzEQhkVJaRy3t57LkkNPWWf0sfo4hpAmAUNocYvxRWglLV1nbTmSlsT_Ppt4SSCnGZhnXmYehL5jmGFQ9NyvwznhMzZjtPqEJphxKAnBcIQmgBkuKyrFMTpJaQ0AVDLxBR3jinJOpZqg34sQH3pfWLMzts37IjTFxmfTFWbril3o9tbEOmxN9kUdjb33ORWPbf7_On9pQp8LM-6kLuSv6HNjuuS_jXWK_v66WlzelPO769vLi3lpqYJcYu-wcFLKijMqrQFPGqYEkc4KZxknxiheW6gVMVb4xqu6crXzTmIrJcd0in4ecncxDB-krDdtsr7rzNaHPmnOpaAM0wE8_QCuQx-3w22agALgCuQAnR0gG0NK0Td6F9uNiXuNQb941oNnTbhmevA84D_GzL7eePcOj2IHoDwAbcr-6W1u4r3mgopK3yxXeoE5kNWfpf5HnwFy0oh_</recordid><startdate>20040801</startdate><enddate>20040801</enddate><creator>Harzer, Winfried</creator><creator>Bourauel, Christoph</creator><creator>Gmyrek, Henner</creator><general>Oxford University Press</general><general>Oxford Publishing Limited (England)</general><scope>BSCLL</scope><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7QP</scope><scope>K9.</scope><scope>7X8</scope></search><sort><creationdate>20040801</creationdate><title>Torque capacity of metal and polycarbonate brackets with and without a metal slot</title><author>Harzer, Winfried ; Bourauel, Christoph ; Gmyrek, Henner</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c390t-1ed17d88856438ca0e2f49728dc7dc462aa96bc0b92ac7efe9b5dbded81c88613</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2004</creationdate><topic>Dental Alloys - chemistry</topic><topic>Dentistry</topic><topic>Humans</topic><topic>Incisor</topic><topic>Materials Testing</topic><topic>Orthodontic Appliance Design</topic><topic>Orthodontic Brackets</topic><topic>Polymers - chemistry</topic><topic>Stainless Steel - chemistry</topic><topic>Stress, Mechanical</topic><topic>Surface Properties</topic><topic>Torque</topic><topic>Transducers</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Harzer, Winfried</creatorcontrib><creatorcontrib>Bourauel, Christoph</creatorcontrib><creatorcontrib>Gmyrek, Henner</creatorcontrib><collection>Istex</collection><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>Calcium & Calcified Tissue Abstracts</collection><collection>ProQuest Health & Medical Complete (Alumni)</collection><collection>MEDLINE - Academic</collection><jtitle>European journal of orthodontics</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Harzer, Winfried</au><au>Bourauel, Christoph</au><au>Gmyrek, Henner</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Torque capacity of metal and polycarbonate brackets with and without a metal slot</atitle><jtitle>European journal of orthodontics</jtitle><addtitle>Eur J Orthod</addtitle><date>2004-08-01</date><risdate>2004</risdate><volume>26</volume><issue>4</issue><spage>435</spage><epage>441</epage><pages>435-441</pages><issn>0141-5387</issn><eissn>1460-2210</eissn><coden>EJOODK</coden><abstract>The aim of the present study was to investigate slot deformation and the equivalent torque capacity of polycarbonate brackets with and without a metal slot in comparison with those of a metal bracket. For this purpose, the expansion characteristics and, in a further investigation, the labial crown torque of an upper central incisor, were measured in a simulated intra-oral clinical situation, using the orthodontic measuring and simulation system (OMSS). Three types of bracket with a 0.018 inch slot were tested: polycarbonate Brillant® without a metal slot, Elegance® with a metal slot and the metal bracket, Mini-Mono®. For testing purposes the brackets were torqued with 0.016 × 0.022 inch (0.41 × 0.56 mm) and 0.018 × 0.022 inch (0.46 × 0.56 mm) ideal stainless steel archwires. In the activating experiments, significantly higher torque losses and lower torquing moments were registered with both rectangular archwires with the polycarbonate brackets than with the metal bracket. In the simulation tests, significantly higher torquing moments were registered with the metal bracket than with the polycarbonate brackets. The values for the Elegance® bracket were between those of the Mini-Mono® and Brillant® brackets. The OMSS model approximates the clinical situation, with the torque loss being notably higher than in the in vitro activating experiments. This is due to the adjacent teeth giving the archwire additional play. In addition, the torquing process may twist the archwire, resulting in subsidiary forces. On the basis of the present results, all three brackets can be recommended for torquing. However, in view of the high torque losses, the torques programmed in the straightwire technique must be seen as questionable. Data should be provided by the manufacturer on the bending to be expected in polycarbonate brackets, which has to be offset by additional torque, or the bracket torque should be omitted from the technical specifications.</abstract><cop>England</cop><pub>Oxford University Press</pub><pmid>15366389</pmid><doi>10.1093/ejo/26.4.435</doi><tpages>7</tpages><oa>free_for_read</oa></addata></record> |
fulltext | fulltext |
identifier | ISSN: 0141-5387 |
ispartof | European journal of orthodontics, 2004-08, Vol.26 (4), p.435-441 |
issn | 0141-5387 1460-2210 |
language | eng |
recordid | cdi_proquest_miscellaneous_66873413 |
source | MEDLINE; Elektronische Zeitschriftenbibliothek - Frei zugängliche E-Journals; Oxford University Press Journals All Titles (1996-Current) |
subjects | Dental Alloys - chemistry Dentistry Humans Incisor Materials Testing Orthodontic Appliance Design Orthodontic Brackets Polymers - chemistry Stainless Steel - chemistry Stress, Mechanical Surface Properties Torque Transducers |
title | Torque capacity of metal and polycarbonate brackets with and without a metal slot |
url | https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-20T17%3A56%3A21IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Torque%20capacity%20of%20metal%20and%20polycarbonate%20brackets%20with%20and%20without%20a%20metal%20slot&rft.jtitle=European%20journal%20of%20orthodontics&rft.au=Harzer,%20Winfried&rft.date=2004-08-01&rft.volume=26&rft.issue=4&rft.spage=435&rft.epage=441&rft.pages=435-441&rft.issn=0141-5387&rft.eissn=1460-2210&rft.coden=EJOODK&rft_id=info:doi/10.1093/ejo/26.4.435&rft_dat=%3Cproquest_cross%3E66873413%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=209006908&rft_id=info:pmid/15366389&rfr_iscdi=true |