Rapid ultrasensitive measurement of salivary cortisol using nano-linker chemistry coupled with surface plasmon resonance detection
Cortisol detection in saliva is of great interest for the diagnosis of various disease states and the monitoring of stress in humans. Currently, measurements are performed predominantly by radioimmunoassay (RIA) which is expensive, labour intensive, uses hazardous radioisotopes and involves extensiv...
Gespeichert in:
Veröffentlicht in: | Analyst (London) 2009-02, Vol.134 (2), p.380-386 |
---|---|
Hauptverfasser: | , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
container_end_page | 386 |
---|---|
container_issue | 2 |
container_start_page | 380 |
container_title | Analyst (London) |
container_volume | 134 |
creator | MITCHELL, John S LOWE, Tim E INGRAM, John R |
description | Cortisol detection in saliva is of great interest for the diagnosis of various disease states and the monitoring of stress in humans. Currently, measurements are performed predominantly by radioimmunoassay (RIA) which is expensive, labour intensive, uses hazardous radioisotopes and involves extensive delays in obtaining results. A rationally designed cortisol-linker conjugate allowing high assay sensitivity was employed as a coating antigen in a microfluidic surface plasmon resonance (SPR) biosensor immunoassay for the ultrasensitive and rapid detection of salivary cortisol. Detection of cortisol is by competitive immunoassay using a secondary antibody for signal enhancement. The method requires no chemical extraction or complex sample pre-treatment despite high saliva viscosity. The cortisol assay was optimized for maximum sensitivity in buffer before being adapted for the salivary matrix, where it showed a limit of detection of 49 pg/mL. The results showed good correlation to RIA (r = 0.94). The biosensor assays showed an inter-assay coefficient of variation (CV) of 13.5% and recoveries close to 100%. The covalently immobilized sensor surface provided stable responses for more than 140 binding and regeneration cycles, enabling re-use. Cortisol in saliva was detected across the physiologically relevant range using the SPR immunobiosensor by employing a rationally designed assay format including signal enhancement for maximum sensitivity. The system can handle saliva matrix effects by use of chemical treatment during the assay to reduce non-specific binding to sensor surfaces. This sensor system provides an automated, high sensitivity analytical tool capable of yielding results in approximately 15 min. This biosensor could potentially be used for active stress-monitoring and in the diagnosis of disease. |
doi_str_mv | 10.1039/b817083p |
format | Article |
fullrecord | <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_66862331</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>33484173</sourcerecordid><originalsourceid>FETCH-LOGICAL-c381t-fcd1657ade61505f3375e75aca814e4279ce319d760d433d6c6bbe23380b1c153</originalsourceid><addsrcrecordid>eNqF0U2L1TAUBuAgDs51FPwFko3ipmNO06S9S2fwCwZGRNclTU6daJrUnHTErb_c6L3oclYh4TmH8L6MPQFxDkLuX04D9GKQ6z22A6m7Rql2uM92QgjZtFp1p-wh0dd6BaHEA3YKe-il0HrHfn00q3d8CyUbwki--FvkCxraMi4YC08zJxP8rck_uU25eEqBb-TjFx5NTE3w8Rtmbm9w8VT-om0N6PgPX254XTMbi3wNhpYUeUZKday-OCxoi0_xETuZTSB8fDzP2Oc3rz9dvmuurt--v3x11Vg5QGlm60Cr3jjUoISapewV9spYM0CHXdvvLUrYu14L10nptNXThK2Ug5jAgpJn7Plh75rT9w2pjPXDFkMwEdNGo9aDrhzuhFJ2Q1cDrPDFAdqciDLO45r9UoMaQYx_ihkvDsV8qPTpcec2Lej-w2MTFTw7AkPWhDnXkDz9cy1AO4Do5G_7cJgm</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>33484173</pqid></control><display><type>article</type><title>Rapid ultrasensitive measurement of salivary cortisol using nano-linker chemistry coupled with surface plasmon resonance detection</title><source>MEDLINE</source><source>Royal Society of Chemistry Journals Archive (1841-2007)</source><source>Royal Society Of Chemistry Journals 2008-</source><source>Alma/SFX Local Collection</source><creator>MITCHELL, John S ; LOWE, Tim E ; INGRAM, John R</creator><creatorcontrib>MITCHELL, John S ; LOWE, Tim E ; INGRAM, John R</creatorcontrib><description>Cortisol detection in saliva is of great interest for the diagnosis of various disease states and the monitoring of stress in humans. Currently, measurements are performed predominantly by radioimmunoassay (RIA) which is expensive, labour intensive, uses hazardous radioisotopes and involves extensive delays in obtaining results. A rationally designed cortisol-linker conjugate allowing high assay sensitivity was employed as a coating antigen in a microfluidic surface plasmon resonance (SPR) biosensor immunoassay for the ultrasensitive and rapid detection of salivary cortisol. Detection of cortisol is by competitive immunoassay using a secondary antibody for signal enhancement. The method requires no chemical extraction or complex sample pre-treatment despite high saliva viscosity. The cortisol assay was optimized for maximum sensitivity in buffer before being adapted for the salivary matrix, where it showed a limit of detection of 49 pg/mL. The results showed good correlation to RIA (r = 0.94). The biosensor assays showed an inter-assay coefficient of variation (CV) of 13.5% and recoveries close to 100%. The covalently immobilized sensor surface provided stable responses for more than 140 binding and regeneration cycles, enabling re-use. Cortisol in saliva was detected across the physiologically relevant range using the SPR immunobiosensor by employing a rationally designed assay format including signal enhancement for maximum sensitivity. The system can handle saliva matrix effects by use of chemical treatment during the assay to reduce non-specific binding to sensor surfaces. This sensor system provides an automated, high sensitivity analytical tool capable of yielding results in approximately 15 min. This biosensor could potentially be used for active stress-monitoring and in the diagnosis of disease.</description><identifier>ISSN: 0003-2654</identifier><identifier>EISSN: 1364-5528</identifier><identifier>DOI: 10.1039/b817083p</identifier><identifier>PMID: 19173066</identifier><identifier>CODEN: ANALAO</identifier><language>eng</language><publisher>Cambridge: Royal Society of Chemistry</publisher><subject>Analytical chemistry ; Biological and medical sciences ; Biosensing Techniques - methods ; Biosensors ; Biotechnology ; Chemistry ; Exact sciences and technology ; Flow Injection Analysis - methods ; Fundamental and applied biological sciences. Psychology ; General, instrumentation ; Humans ; Hydrocortisone - analysis ; Male ; Methods. Procedures. Technologies ; Miscellaneous ; Radioimmunoassay - methods ; Saliva - chemistry ; Sensitivity and Specificity ; Surface Plasmon Resonance - methods ; Various methods and equipments</subject><ispartof>Analyst (London), 2009-02, Vol.134 (2), p.380-386</ispartof><rights>2009 INIST-CNRS</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c381t-fcd1657ade61505f3375e75aca814e4279ce319d760d433d6c6bbe23380b1c153</citedby><cites>FETCH-LOGICAL-c381t-fcd1657ade61505f3375e75aca814e4279ce319d760d433d6c6bbe23380b1c153</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,780,784,2831,27924,27925</link.rule.ids><backlink>$$Uhttp://pascal-francis.inist.fr/vibad/index.php?action=getRecordDetail&idt=21128104$$DView record in Pascal Francis$$Hfree_for_read</backlink><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/19173066$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>MITCHELL, John S</creatorcontrib><creatorcontrib>LOWE, Tim E</creatorcontrib><creatorcontrib>INGRAM, John R</creatorcontrib><title>Rapid ultrasensitive measurement of salivary cortisol using nano-linker chemistry coupled with surface plasmon resonance detection</title><title>Analyst (London)</title><addtitle>Analyst</addtitle><description>Cortisol detection in saliva is of great interest for the diagnosis of various disease states and the monitoring of stress in humans. Currently, measurements are performed predominantly by radioimmunoassay (RIA) which is expensive, labour intensive, uses hazardous radioisotopes and involves extensive delays in obtaining results. A rationally designed cortisol-linker conjugate allowing high assay sensitivity was employed as a coating antigen in a microfluidic surface plasmon resonance (SPR) biosensor immunoassay for the ultrasensitive and rapid detection of salivary cortisol. Detection of cortisol is by competitive immunoassay using a secondary antibody for signal enhancement. The method requires no chemical extraction or complex sample pre-treatment despite high saliva viscosity. The cortisol assay was optimized for maximum sensitivity in buffer before being adapted for the salivary matrix, where it showed a limit of detection of 49 pg/mL. The results showed good correlation to RIA (r = 0.94). The biosensor assays showed an inter-assay coefficient of variation (CV) of 13.5% and recoveries close to 100%. The covalently immobilized sensor surface provided stable responses for more than 140 binding and regeneration cycles, enabling re-use. Cortisol in saliva was detected across the physiologically relevant range using the SPR immunobiosensor by employing a rationally designed assay format including signal enhancement for maximum sensitivity. The system can handle saliva matrix effects by use of chemical treatment during the assay to reduce non-specific binding to sensor surfaces. This sensor system provides an automated, high sensitivity analytical tool capable of yielding results in approximately 15 min. This biosensor could potentially be used for active stress-monitoring and in the diagnosis of disease.</description><subject>Analytical chemistry</subject><subject>Biological and medical sciences</subject><subject>Biosensing Techniques - methods</subject><subject>Biosensors</subject><subject>Biotechnology</subject><subject>Chemistry</subject><subject>Exact sciences and technology</subject><subject>Flow Injection Analysis - methods</subject><subject>Fundamental and applied biological sciences. Psychology</subject><subject>General, instrumentation</subject><subject>Humans</subject><subject>Hydrocortisone - analysis</subject><subject>Male</subject><subject>Methods. Procedures. Technologies</subject><subject>Miscellaneous</subject><subject>Radioimmunoassay - methods</subject><subject>Saliva - chemistry</subject><subject>Sensitivity and Specificity</subject><subject>Surface Plasmon Resonance - methods</subject><subject>Various methods and equipments</subject><issn>0003-2654</issn><issn>1364-5528</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2009</creationdate><recordtype>article</recordtype><sourceid>EIF</sourceid><recordid>eNqF0U2L1TAUBuAgDs51FPwFko3ipmNO06S9S2fwCwZGRNclTU6daJrUnHTErb_c6L3oclYh4TmH8L6MPQFxDkLuX04D9GKQ6z22A6m7Rql2uM92QgjZtFp1p-wh0dd6BaHEA3YKe-il0HrHfn00q3d8CyUbwki--FvkCxraMi4YC08zJxP8rck_uU25eEqBb-TjFx5NTE3w8Rtmbm9w8VT-om0N6PgPX254XTMbi3wNhpYUeUZKday-OCxoi0_xETuZTSB8fDzP2Oc3rz9dvmuurt--v3x11Vg5QGlm60Cr3jjUoISapewV9spYM0CHXdvvLUrYu14L10nptNXThK2Ug5jAgpJn7Plh75rT9w2pjPXDFkMwEdNGo9aDrhzuhFJ2Q1cDrPDFAdqciDLO45r9UoMaQYx_ihkvDsV8qPTpcec2Lej-w2MTFTw7AkPWhDnXkDz9cy1AO4Do5G_7cJgm</recordid><startdate>200902</startdate><enddate>200902</enddate><creator>MITCHELL, John S</creator><creator>LOWE, Tim E</creator><creator>INGRAM, John R</creator><general>Royal Society of Chemistry</general><scope>IQODW</scope><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7SR</scope><scope>7U5</scope><scope>8BQ</scope><scope>8FD</scope><scope>JG9</scope><scope>L7M</scope><scope>7X8</scope></search><sort><creationdate>200902</creationdate><title>Rapid ultrasensitive measurement of salivary cortisol using nano-linker chemistry coupled with surface plasmon resonance detection</title><author>MITCHELL, John S ; LOWE, Tim E ; INGRAM, John R</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c381t-fcd1657ade61505f3375e75aca814e4279ce319d760d433d6c6bbe23380b1c153</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2009</creationdate><topic>Analytical chemistry</topic><topic>Biological and medical sciences</topic><topic>Biosensing Techniques - methods</topic><topic>Biosensors</topic><topic>Biotechnology</topic><topic>Chemistry</topic><topic>Exact sciences and technology</topic><topic>Flow Injection Analysis - methods</topic><topic>Fundamental and applied biological sciences. Psychology</topic><topic>General, instrumentation</topic><topic>Humans</topic><topic>Hydrocortisone - analysis</topic><topic>Male</topic><topic>Methods. Procedures. Technologies</topic><topic>Miscellaneous</topic><topic>Radioimmunoassay - methods</topic><topic>Saliva - chemistry</topic><topic>Sensitivity and Specificity</topic><topic>Surface Plasmon Resonance - methods</topic><topic>Various methods and equipments</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>MITCHELL, John S</creatorcontrib><creatorcontrib>LOWE, Tim E</creatorcontrib><creatorcontrib>INGRAM, John R</creatorcontrib><collection>Pascal-Francis</collection><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>Engineered Materials Abstracts</collection><collection>Solid State and Superconductivity Abstracts</collection><collection>METADEX</collection><collection>Technology Research Database</collection><collection>Materials Research Database</collection><collection>Advanced Technologies Database with Aerospace</collection><collection>MEDLINE - Academic</collection><jtitle>Analyst (London)</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>MITCHELL, John S</au><au>LOWE, Tim E</au><au>INGRAM, John R</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Rapid ultrasensitive measurement of salivary cortisol using nano-linker chemistry coupled with surface plasmon resonance detection</atitle><jtitle>Analyst (London)</jtitle><addtitle>Analyst</addtitle><date>2009-02</date><risdate>2009</risdate><volume>134</volume><issue>2</issue><spage>380</spage><epage>386</epage><pages>380-386</pages><issn>0003-2654</issn><eissn>1364-5528</eissn><coden>ANALAO</coden><abstract>Cortisol detection in saliva is of great interest for the diagnosis of various disease states and the monitoring of stress in humans. Currently, measurements are performed predominantly by radioimmunoassay (RIA) which is expensive, labour intensive, uses hazardous radioisotopes and involves extensive delays in obtaining results. A rationally designed cortisol-linker conjugate allowing high assay sensitivity was employed as a coating antigen in a microfluidic surface plasmon resonance (SPR) biosensor immunoassay for the ultrasensitive and rapid detection of salivary cortisol. Detection of cortisol is by competitive immunoassay using a secondary antibody for signal enhancement. The method requires no chemical extraction or complex sample pre-treatment despite high saliva viscosity. The cortisol assay was optimized for maximum sensitivity in buffer before being adapted for the salivary matrix, where it showed a limit of detection of 49 pg/mL. The results showed good correlation to RIA (r = 0.94). The biosensor assays showed an inter-assay coefficient of variation (CV) of 13.5% and recoveries close to 100%. The covalently immobilized sensor surface provided stable responses for more than 140 binding and regeneration cycles, enabling re-use. Cortisol in saliva was detected across the physiologically relevant range using the SPR immunobiosensor by employing a rationally designed assay format including signal enhancement for maximum sensitivity. The system can handle saliva matrix effects by use of chemical treatment during the assay to reduce non-specific binding to sensor surfaces. This sensor system provides an automated, high sensitivity analytical tool capable of yielding results in approximately 15 min. This biosensor could potentially be used for active stress-monitoring and in the diagnosis of disease.</abstract><cop>Cambridge</cop><pub>Royal Society of Chemistry</pub><pmid>19173066</pmid><doi>10.1039/b817083p</doi><tpages>7</tpages></addata></record> |
fulltext | fulltext |
identifier | ISSN: 0003-2654 |
ispartof | Analyst (London), 2009-02, Vol.134 (2), p.380-386 |
issn | 0003-2654 1364-5528 |
language | eng |
recordid | cdi_proquest_miscellaneous_66862331 |
source | MEDLINE; Royal Society of Chemistry Journals Archive (1841-2007); Royal Society Of Chemistry Journals 2008-; Alma/SFX Local Collection |
subjects | Analytical chemistry Biological and medical sciences Biosensing Techniques - methods Biosensors Biotechnology Chemistry Exact sciences and technology Flow Injection Analysis - methods Fundamental and applied biological sciences. Psychology General, instrumentation Humans Hydrocortisone - analysis Male Methods. Procedures. Technologies Miscellaneous Radioimmunoassay - methods Saliva - chemistry Sensitivity and Specificity Surface Plasmon Resonance - methods Various methods and equipments |
title | Rapid ultrasensitive measurement of salivary cortisol using nano-linker chemistry coupled with surface plasmon resonance detection |
url | https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-04T02%3A28%3A20IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Rapid%20ultrasensitive%20measurement%20of%20salivary%20cortisol%20using%20nano-linker%20chemistry%20coupled%20with%20surface%20plasmon%20resonance%20detection&rft.jtitle=Analyst%20(London)&rft.au=MITCHELL,%20John%20S&rft.date=2009-02&rft.volume=134&rft.issue=2&rft.spage=380&rft.epage=386&rft.pages=380-386&rft.issn=0003-2654&rft.eissn=1364-5528&rft.coden=ANALAO&rft_id=info:doi/10.1039/b817083p&rft_dat=%3Cproquest_cross%3E33484173%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=33484173&rft_id=info:pmid/19173066&rfr_iscdi=true |