NO(2) sensors with room temperature operation and long term stability using copper phthalocyanine thin films

Effect of substrate temperature on microstructure of copper phthalocyanine (CuPc) thin films deposited on quartz and polycrystalline alumina substrates by vacuum sublimation technique has been studied. The films undergo a transition from a phase at lower substrate temperatures to b phase for tempera...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Sensors and actuators. B, Chemical Chemical, 2009-12, Vol.143 (1), p.246-252
Hauptverfasser: Padma, N, Joshi, A, Singh, A, Deshpande, S K, Aswal, D K, Gupta, S K, Yakhmi, J V
Format: Artikel
Sprache:eng
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 252
container_issue 1
container_start_page 246
container_title Sensors and actuators. B, Chemical
container_volume 143
creator Padma, N
Joshi, A
Singh, A
Deshpande, S K
Aswal, D K
Gupta, S K
Yakhmi, J V
description Effect of substrate temperature on microstructure of copper phthalocyanine (CuPc) thin films deposited on quartz and polycrystalline alumina substrates by vacuum sublimation technique has been studied. The films undergo a transition from a phase at lower substrate temperatures to b phase for temperatures above 200(o)C. A simultaneous change in morphology from granular to nano-fibrous films was observed. Resistance of a phase films increased by more than one order of magnitude on initial application of electric field requiring stabilization for several hours, while b phase films did not show any drift. This behavior was attributed to oxygen absorption/desorption under applied field. Sensitivity of films for detection of NO(2) gas at room temperature was found to be higher for films in the a-phase with nano-fibrous morphology. Methodology was devised for measurement of NO(2) concentration in ppm range with good response and recovery times. With this methodology, the sensors showed very good stability in response (at room temperature) for a period of 1 year.
doi_str_mv 10.1016/j.snb.2009.07.044
format Article
fullrecord <record><control><sourceid>proquest</sourceid><recordid>TN_cdi_proquest_miscellaneous_36507272</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>36507272</sourcerecordid><originalsourceid>FETCH-proquest_miscellaneous_365072723</originalsourceid><addsrcrecordid>eNqNirtOAzEQRV2ARHh8AN1UCIqYWe9LqRGIijT0kbM47ET2zOLxCuXvWSE-gOpcnXuMua3QVlh1j0ervLcOcWOxt9g0Z2aFG9euG8T2wlyqHhGxqTtcmfi2vXcPoIFVssI3lRGySIIS0hSyL3MOIL-LhMHzB0Thz-XOCbT4PUUqJ5iVFjnItJQwjWX0UYaTZ-IAZSSGA8Wk1-b84KOGmz9embuX5_en1_WU5WsOWnaJdAgxeg4y667uWuxd7-p_hz-8bVJY</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>36507272</pqid></control><display><type>article</type><title>NO(2) sensors with room temperature operation and long term stability using copper phthalocyanine thin films</title><source>Elsevier ScienceDirect Journals</source><creator>Padma, N ; Joshi, A ; Singh, A ; Deshpande, S K ; Aswal, D K ; Gupta, S K ; Yakhmi, J V</creator><creatorcontrib>Padma, N ; Joshi, A ; Singh, A ; Deshpande, S K ; Aswal, D K ; Gupta, S K ; Yakhmi, J V</creatorcontrib><description>Effect of substrate temperature on microstructure of copper phthalocyanine (CuPc) thin films deposited on quartz and polycrystalline alumina substrates by vacuum sublimation technique has been studied. The films undergo a transition from a phase at lower substrate temperatures to b phase for temperatures above 200(o)C. A simultaneous change in morphology from granular to nano-fibrous films was observed. Resistance of a phase films increased by more than one order of magnitude on initial application of electric field requiring stabilization for several hours, while b phase films did not show any drift. This behavior was attributed to oxygen absorption/desorption under applied field. Sensitivity of films for detection of NO(2) gas at room temperature was found to be higher for films in the a-phase with nano-fibrous morphology. Methodology was devised for measurement of NO(2) concentration in ppm range with good response and recovery times. With this methodology, the sensors showed very good stability in response (at room temperature) for a period of 1 year.</description><identifier>ISSN: 0925-4005</identifier><identifier>DOI: 10.1016/j.snb.2009.07.044</identifier><language>eng</language><ispartof>Sensors and actuators. B, Chemical, 2009-12, Vol.143 (1), p.246-252</ispartof><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,776,780,27901,27902</link.rule.ids></links><search><creatorcontrib>Padma, N</creatorcontrib><creatorcontrib>Joshi, A</creatorcontrib><creatorcontrib>Singh, A</creatorcontrib><creatorcontrib>Deshpande, S K</creatorcontrib><creatorcontrib>Aswal, D K</creatorcontrib><creatorcontrib>Gupta, S K</creatorcontrib><creatorcontrib>Yakhmi, J V</creatorcontrib><title>NO(2) sensors with room temperature operation and long term stability using copper phthalocyanine thin films</title><title>Sensors and actuators. B, Chemical</title><description>Effect of substrate temperature on microstructure of copper phthalocyanine (CuPc) thin films deposited on quartz and polycrystalline alumina substrates by vacuum sublimation technique has been studied. The films undergo a transition from a phase at lower substrate temperatures to b phase for temperatures above 200(o)C. A simultaneous change in morphology from granular to nano-fibrous films was observed. Resistance of a phase films increased by more than one order of magnitude on initial application of electric field requiring stabilization for several hours, while b phase films did not show any drift. This behavior was attributed to oxygen absorption/desorption under applied field. Sensitivity of films for detection of NO(2) gas at room temperature was found to be higher for films in the a-phase with nano-fibrous morphology. Methodology was devised for measurement of NO(2) concentration in ppm range with good response and recovery times. With this methodology, the sensors showed very good stability in response (at room temperature) for a period of 1 year.</description><issn>0925-4005</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2009</creationdate><recordtype>article</recordtype><recordid>eNqNirtOAzEQRV2ARHh8AN1UCIqYWe9LqRGIijT0kbM47ET2zOLxCuXvWSE-gOpcnXuMua3QVlh1j0ervLcOcWOxt9g0Z2aFG9euG8T2wlyqHhGxqTtcmfi2vXcPoIFVssI3lRGySIIS0hSyL3MOIL-LhMHzB0Thz-XOCbT4PUUqJ5iVFjnItJQwjWX0UYaTZ-IAZSSGA8Wk1-b84KOGmz9embuX5_en1_WU5WsOWnaJdAgxeg4y667uWuxd7-p_hz-8bVJY</recordid><startdate>20091204</startdate><enddate>20091204</enddate><creator>Padma, N</creator><creator>Joshi, A</creator><creator>Singh, A</creator><creator>Deshpande, S K</creator><creator>Aswal, D K</creator><creator>Gupta, S K</creator><creator>Yakhmi, J V</creator><scope>7TB</scope><scope>7U5</scope><scope>8FD</scope><scope>FR3</scope><scope>L7M</scope></search><sort><creationdate>20091204</creationdate><title>NO(2) sensors with room temperature operation and long term stability using copper phthalocyanine thin films</title><author>Padma, N ; Joshi, A ; Singh, A ; Deshpande, S K ; Aswal, D K ; Gupta, S K ; Yakhmi, J V</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-proquest_miscellaneous_365072723</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2009</creationdate><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Padma, N</creatorcontrib><creatorcontrib>Joshi, A</creatorcontrib><creatorcontrib>Singh, A</creatorcontrib><creatorcontrib>Deshpande, S K</creatorcontrib><creatorcontrib>Aswal, D K</creatorcontrib><creatorcontrib>Gupta, S K</creatorcontrib><creatorcontrib>Yakhmi, J V</creatorcontrib><collection>Mechanical &amp; Transportation Engineering Abstracts</collection><collection>Solid State and Superconductivity Abstracts</collection><collection>Technology Research Database</collection><collection>Engineering Research Database</collection><collection>Advanced Technologies Database with Aerospace</collection><jtitle>Sensors and actuators. B, Chemical</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Padma, N</au><au>Joshi, A</au><au>Singh, A</au><au>Deshpande, S K</au><au>Aswal, D K</au><au>Gupta, S K</au><au>Yakhmi, J V</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>NO(2) sensors with room temperature operation and long term stability using copper phthalocyanine thin films</atitle><jtitle>Sensors and actuators. B, Chemical</jtitle><date>2009-12-04</date><risdate>2009</risdate><volume>143</volume><issue>1</issue><spage>246</spage><epage>252</epage><pages>246-252</pages><issn>0925-4005</issn><abstract>Effect of substrate temperature on microstructure of copper phthalocyanine (CuPc) thin films deposited on quartz and polycrystalline alumina substrates by vacuum sublimation technique has been studied. The films undergo a transition from a phase at lower substrate temperatures to b phase for temperatures above 200(o)C. A simultaneous change in morphology from granular to nano-fibrous films was observed. Resistance of a phase films increased by more than one order of magnitude on initial application of electric field requiring stabilization for several hours, while b phase films did not show any drift. This behavior was attributed to oxygen absorption/desorption under applied field. Sensitivity of films for detection of NO(2) gas at room temperature was found to be higher for films in the a-phase with nano-fibrous morphology. Methodology was devised for measurement of NO(2) concentration in ppm range with good response and recovery times. With this methodology, the sensors showed very good stability in response (at room temperature) for a period of 1 year.</abstract><doi>10.1016/j.snb.2009.07.044</doi></addata></record>
fulltext fulltext
identifier ISSN: 0925-4005
ispartof Sensors and actuators. B, Chemical, 2009-12, Vol.143 (1), p.246-252
issn 0925-4005
language eng
recordid cdi_proquest_miscellaneous_36507272
source Elsevier ScienceDirect Journals
title NO(2) sensors with room temperature operation and long term stability using copper phthalocyanine thin films
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-28T19%3A40%3A18IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=NO(2)%20sensors%20with%20room%20temperature%20operation%20and%20long%20term%20stability%20using%20copper%20phthalocyanine%20thin%20films&rft.jtitle=Sensors%20and%20actuators.%20B,%20Chemical&rft.au=Padma,%20N&rft.date=2009-12-04&rft.volume=143&rft.issue=1&rft.spage=246&rft.epage=252&rft.pages=246-252&rft.issn=0925-4005&rft_id=info:doi/10.1016/j.snb.2009.07.044&rft_dat=%3Cproquest%3E36507272%3C/proquest%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=36507272&rft_id=info:pmid/&rfr_iscdi=true