Determination of Radiation Energy Response for Thermoluminescent Dosimeter TLD-100: Determination of Organ Dose in Diagnostic Radiology (abstract)
TLD-100 (thermoluminescent dosimeter) cards (chips) were calibrated using X-rays with energies of 25-250 kV produced by a Cs-137 source. The energy responses of lithium fluoride crystals for different energies of X-rays were studied. QA/QC was then performed in the Albanian Ionizing Radiation Metrol...
Gespeichert in:
Veröffentlicht in: | AIP conference proceedings 2008-10, Vol.1119, p.209b-209b |
---|---|
Hauptverfasser: | , |
Format: | Artikel |
Sprache: | eng |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
container_end_page | 209b |
---|---|
container_issue | |
container_start_page | 209b |
container_title | AIP conference proceedings |
container_volume | 1119 |
creator | Deda, Antoneta Telhaj, Ervis |
description | TLD-100 (thermoluminescent dosimeter) cards (chips) were calibrated using X-rays with energies of 25-250 kV produced by a Cs-137 source. The energy responses of lithium fluoride crystals for different energies of X-rays were studied. QA/QC was then performed in the Albanian Ionizing Radiation Metrology Laboratory. Based on the QA/QC results, the chips were used to study the doses to different organs in diagnostic radiology. Organ dose was evaluated after calculation of e dose in air (Kair), using an ionizing chamber. |
format | Article |
fullrecord | <record><control><sourceid>proquest</sourceid><recordid>TN_cdi_proquest_miscellaneous_34976323</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>34976323</sourcerecordid><originalsourceid>FETCH-proquest_miscellaneous_349763233</originalsourceid><addsrcrecordid>eNqNjb1uwjAUhT0UCUp5hzshGCK5cURI1wbUAakSytANueEmGDm-1NcZ-ho8cc3P1oXp6EjfOd-TGElZZEmaqa-heGY-SpkWeb4ciXOJAX1nnA6GHFADW703t7Jy6Ntf2CKfyDFCQx6qQ6TJ9nGBXKMLUBKb7nIC1aZMXqV8g3-fn77V7kIimJhGt444mPoqI0vRMtPfHLyuw_xFDBptGSf3HIvpelW9fyQnTz89cth1Jqqt1Q6p553KinyhUqUeBv8ADAJZgA</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>34976323</pqid></control><display><type>article</type><title>Determination of Radiation Energy Response for Thermoluminescent Dosimeter TLD-100: Determination of Organ Dose in Diagnostic Radiology (abstract)</title><source>AIP Journals Complete</source><creator>Deda, Antoneta ; Telhaj, Ervis</creator><creatorcontrib>Deda, Antoneta ; Telhaj, Ervis</creatorcontrib><description>TLD-100 (thermoluminescent dosimeter) cards (chips) were calibrated using X-rays with energies of 25-250 kV produced by a Cs-137 source. The energy responses of lithium fluoride crystals for different energies of X-rays were studied. QA/QC was then performed in the Albanian Ionizing Radiation Metrology Laboratory. Based on the QA/QC results, the chips were used to study the doses to different organs in diagnostic radiology. Organ dose was evaluated after calculation of e dose in air (Kair), using an ionizing chamber.</description><identifier>ISSN: 0094-243X</identifier><language>eng</language><ispartof>AIP conference proceedings, 2008-10, Vol.1119, p.209b-209b</ispartof><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,780,784</link.rule.ids></links><search><creatorcontrib>Deda, Antoneta</creatorcontrib><creatorcontrib>Telhaj, Ervis</creatorcontrib><title>Determination of Radiation Energy Response for Thermoluminescent Dosimeter TLD-100: Determination of Organ Dose in Diagnostic Radiology (abstract)</title><title>AIP conference proceedings</title><description>TLD-100 (thermoluminescent dosimeter) cards (chips) were calibrated using X-rays with energies of 25-250 kV produced by a Cs-137 source. The energy responses of lithium fluoride crystals for different energies of X-rays were studied. QA/QC was then performed in the Albanian Ionizing Radiation Metrology Laboratory. Based on the QA/QC results, the chips were used to study the doses to different organs in diagnostic radiology. Organ dose was evaluated after calculation of e dose in air (Kair), using an ionizing chamber.</description><issn>0094-243X</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2008</creationdate><recordtype>article</recordtype><recordid>eNqNjb1uwjAUhT0UCUp5hzshGCK5cURI1wbUAakSytANueEmGDm-1NcZ-ho8cc3P1oXp6EjfOd-TGElZZEmaqa-heGY-SpkWeb4ciXOJAX1nnA6GHFADW703t7Jy6Ntf2CKfyDFCQx6qQ6TJ9nGBXKMLUBKb7nIC1aZMXqV8g3-fn77V7kIimJhGt444mPoqI0vRMtPfHLyuw_xFDBptGSf3HIvpelW9fyQnTz89cth1Jqqt1Q6p553KinyhUqUeBv8ADAJZgA</recordid><startdate>20081010</startdate><enddate>20081010</enddate><creator>Deda, Antoneta</creator><creator>Telhaj, Ervis</creator><scope>7U5</scope><scope>8FD</scope><scope>L7M</scope></search><sort><creationdate>20081010</creationdate><title>Determination of Radiation Energy Response for Thermoluminescent Dosimeter TLD-100: Determination of Organ Dose in Diagnostic Radiology (abstract)</title><author>Deda, Antoneta ; Telhaj, Ervis</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-proquest_miscellaneous_349763233</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2008</creationdate><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Deda, Antoneta</creatorcontrib><creatorcontrib>Telhaj, Ervis</creatorcontrib><collection>Solid State and Superconductivity Abstracts</collection><collection>Technology Research Database</collection><collection>Advanced Technologies Database with Aerospace</collection><jtitle>AIP conference proceedings</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Deda, Antoneta</au><au>Telhaj, Ervis</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Determination of Radiation Energy Response for Thermoluminescent Dosimeter TLD-100: Determination of Organ Dose in Diagnostic Radiology (abstract)</atitle><jtitle>AIP conference proceedings</jtitle><date>2008-10-10</date><risdate>2008</risdate><volume>1119</volume><spage>209b</spage><epage>209b</epage><pages>209b-209b</pages><issn>0094-243X</issn><abstract>TLD-100 (thermoluminescent dosimeter) cards (chips) were calibrated using X-rays with energies of 25-250 kV produced by a Cs-137 source. The energy responses of lithium fluoride crystals for different energies of X-rays were studied. QA/QC was then performed in the Albanian Ionizing Radiation Metrology Laboratory. Based on the QA/QC results, the chips were used to study the doses to different organs in diagnostic radiology. Organ dose was evaluated after calculation of e dose in air (Kair), using an ionizing chamber.</abstract></addata></record> |
fulltext | fulltext |
identifier | ISSN: 0094-243X |
ispartof | AIP conference proceedings, 2008-10, Vol.1119, p.209b-209b |
issn | 0094-243X |
language | eng |
recordid | cdi_proquest_miscellaneous_34976323 |
source | AIP Journals Complete |
title | Determination of Radiation Energy Response for Thermoluminescent Dosimeter TLD-100: Determination of Organ Dose in Diagnostic Radiology (abstract) |
url | https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-14T22%3A15%3A33IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Determination%20of%20Radiation%20Energy%20Response%20for%20Thermoluminescent%20Dosimeter%20TLD-100:%20Determination%20of%20Organ%20Dose%20in%20Diagnostic%20Radiology%20(abstract)&rft.jtitle=AIP%20conference%20proceedings&rft.au=Deda,%20Antoneta&rft.date=2008-10-10&rft.volume=1119&rft.spage=209b&rft.epage=209b&rft.pages=209b-209b&rft.issn=0094-243X&rft_id=info:doi/&rft_dat=%3Cproquest%3E34976323%3C/proquest%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=34976323&rft_id=info:pmid/&rfr_iscdi=true |