Effect of surface treatments on fatigue life of Ti-6-22-22 alloy at room and high temperatures
Shot-peening and ion implantation were adopted to treat the surface of machined specimens of Ti-6-22-22 alloy, then stress-controlled fatigue tests were performed at room temperature and 400 °C. Experimental results indicate that the effects of shot-peening and ion implantation on the S–N curves are...
Gespeichert in:
Veröffentlicht in: | Materials science & engineering. A, Structural materials : properties, microstructure and processing Structural materials : properties, microstructure and processing, 2004-10, Vol.383 (2), p.283-288 |
---|---|
Hauptverfasser: | , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
container_end_page | 288 |
---|---|
container_issue | 2 |
container_start_page | 283 |
container_title | Materials science & engineering. A, Structural materials : properties, microstructure and processing |
container_volume | 383 |
creator | Yu, Z.L. Li, S.X. Liu, Y.Y. Zhang, Q.Y. Lei, J.F. Mu, Z.X. |
description | Shot-peening and ion implantation were adopted to treat the surface of machined specimens of Ti-6-22-22 alloy, then stress-controlled fatigue tests were performed at room temperature and 400
°C. Experimental results indicate that the effects of shot-peening and ion implantation on the S–N curves are dependent on temperature. For Ti-6-22-22 alloy fatigued at room temperature, the effects of both, shot-peening and ion implantation of carbon ions on fatigue strength at high cyclic lives are slight. At 400
°C, the fatigue strength at high cyclic lives is obviously increased for both, shot-peening and ion implantation of carbon ions in comparison with the untreated counterparts. |
doi_str_mv | 10.1016/j.msea.2004.06.026 |
format | Article |
fullrecord | <record><control><sourceid>proquest_elsev</sourceid><recordid>TN_cdi_proquest_miscellaneous_34780934</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><els_id>S0921509304008524</els_id><sourcerecordid>28179844</sourcerecordid><originalsourceid>FETCH-LOGICAL-c319t-ca00e194207a92cad0388921bbc4d7430076673e6d8845080511a486544cf1743</originalsourceid><addsrcrecordid>eNqFkE1LxDAURYMoOI7-AVdZuWt9adI0BTcy-AUDbsatIZO-zmRomzFJBf-9LeNeuPA2h8e9h5BbBjkDJu8PeR_R5AWAyEHmUMgzsmCq4pmouTwnC6gLlpVQ80tyFeMBAJiAckE-n9oWbaK-pXEMrbFIU0CTehxSpH6grUluNyLtXIsztXGZzIpiCjVd53-oSTR431MzNHTvdnuasD9iMGkMGK_JRWu6iDd_d0k-np82q9ds_f7ytnpcZ5azOmXWACCrRQGVqQtrGuBKTY23WyuaSnCASsqKo2yUEiUoKBkzQslSCNuyCViSu9PfY_BfI8akexctdp0Z0I9Rc1Gpafz_YKFYVSsxgw8nEKfa3w6DjtbhYLFxYRKmG-80Az3b1wc929ezfQ1ST_b5L3TId2U</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>28179844</pqid></control><display><type>article</type><title>Effect of surface treatments on fatigue life of Ti-6-22-22 alloy at room and high temperatures</title><source>ScienceDirect Journals (5 years ago - present)</source><creator>Yu, Z.L. ; Li, S.X. ; Liu, Y.Y. ; Zhang, Q.Y. ; Lei, J.F. ; Mu, Z.X.</creator><creatorcontrib>Yu, Z.L. ; Li, S.X. ; Liu, Y.Y. ; Zhang, Q.Y. ; Lei, J.F. ; Mu, Z.X.</creatorcontrib><description>Shot-peening and ion implantation were adopted to treat the surface of machined specimens of Ti-6-22-22 alloy, then stress-controlled fatigue tests were performed at room temperature and 400
°C. Experimental results indicate that the effects of shot-peening and ion implantation on the S–N curves are dependent on temperature. For Ti-6-22-22 alloy fatigued at room temperature, the effects of both, shot-peening and ion implantation of carbon ions on fatigue strength at high cyclic lives are slight. At 400
°C, the fatigue strength at high cyclic lives is obviously increased for both, shot-peening and ion implantation of carbon ions in comparison with the untreated counterparts.</description><identifier>ISSN: 0921-5093</identifier><identifier>EISSN: 1873-4936</identifier><identifier>DOI: 10.1016/j.msea.2004.06.026</identifier><language>eng</language><publisher>Elsevier B.V</publisher><subject>Cracks initiation ; Ion implantation ; Shot-peening ; S–N curves ; Ti-6-22-22 alloy</subject><ispartof>Materials science & engineering. A, Structural materials : properties, microstructure and processing, 2004-10, Vol.383 (2), p.283-288</ispartof><rights>2004</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c319t-ca00e194207a92cad0388921bbc4d7430076673e6d8845080511a486544cf1743</citedby></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://dx.doi.org/10.1016/j.msea.2004.06.026$$EHTML$$P50$$Gelsevier$$H</linktohtml><link.rule.ids>314,780,784,3548,27923,27924,45994</link.rule.ids></links><search><creatorcontrib>Yu, Z.L.</creatorcontrib><creatorcontrib>Li, S.X.</creatorcontrib><creatorcontrib>Liu, Y.Y.</creatorcontrib><creatorcontrib>Zhang, Q.Y.</creatorcontrib><creatorcontrib>Lei, J.F.</creatorcontrib><creatorcontrib>Mu, Z.X.</creatorcontrib><title>Effect of surface treatments on fatigue life of Ti-6-22-22 alloy at room and high temperatures</title><title>Materials science & engineering. A, Structural materials : properties, microstructure and processing</title><description>Shot-peening and ion implantation were adopted to treat the surface of machined specimens of Ti-6-22-22 alloy, then stress-controlled fatigue tests were performed at room temperature and 400
°C. Experimental results indicate that the effects of shot-peening and ion implantation on the S–N curves are dependent on temperature. For Ti-6-22-22 alloy fatigued at room temperature, the effects of both, shot-peening and ion implantation of carbon ions on fatigue strength at high cyclic lives are slight. At 400
°C, the fatigue strength at high cyclic lives is obviously increased for both, shot-peening and ion implantation of carbon ions in comparison with the untreated counterparts.</description><subject>Cracks initiation</subject><subject>Ion implantation</subject><subject>Shot-peening</subject><subject>S–N curves</subject><subject>Ti-6-22-22 alloy</subject><issn>0921-5093</issn><issn>1873-4936</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2004</creationdate><recordtype>article</recordtype><recordid>eNqFkE1LxDAURYMoOI7-AVdZuWt9adI0BTcy-AUDbsatIZO-zmRomzFJBf-9LeNeuPA2h8e9h5BbBjkDJu8PeR_R5AWAyEHmUMgzsmCq4pmouTwnC6gLlpVQ80tyFeMBAJiAckE-n9oWbaK-pXEMrbFIU0CTehxSpH6grUluNyLtXIsztXGZzIpiCjVd53-oSTR431MzNHTvdnuasD9iMGkMGK_JRWu6iDd_d0k-np82q9ds_f7ytnpcZ5azOmXWACCrRQGVqQtrGuBKTY23WyuaSnCASsqKo2yUEiUoKBkzQslSCNuyCViSu9PfY_BfI8akexctdp0Z0I9Rc1Gpafz_YKFYVSsxgw8nEKfa3w6DjtbhYLFxYRKmG-80Az3b1wc929ezfQ1ST_b5L3TId2U</recordid><startdate>20041015</startdate><enddate>20041015</enddate><creator>Yu, Z.L.</creator><creator>Li, S.X.</creator><creator>Liu, Y.Y.</creator><creator>Zhang, Q.Y.</creator><creator>Lei, J.F.</creator><creator>Mu, Z.X.</creator><general>Elsevier B.V</general><scope>8BQ</scope><scope>8FD</scope><scope>JG9</scope><scope>7SR</scope></search><sort><creationdate>20041015</creationdate><title>Effect of surface treatments on fatigue life of Ti-6-22-22 alloy at room and high temperatures</title><author>Yu, Z.L. ; Li, S.X. ; Liu, Y.Y. ; Zhang, Q.Y. ; Lei, J.F. ; Mu, Z.X.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c319t-ca00e194207a92cad0388921bbc4d7430076673e6d8845080511a486544cf1743</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2004</creationdate><topic>Cracks initiation</topic><topic>Ion implantation</topic><topic>Shot-peening</topic><topic>S–N curves</topic><topic>Ti-6-22-22 alloy</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Yu, Z.L.</creatorcontrib><creatorcontrib>Li, S.X.</creatorcontrib><creatorcontrib>Liu, Y.Y.</creatorcontrib><creatorcontrib>Zhang, Q.Y.</creatorcontrib><creatorcontrib>Lei, J.F.</creatorcontrib><creatorcontrib>Mu, Z.X.</creatorcontrib><collection>METADEX</collection><collection>Technology Research Database</collection><collection>Materials Research Database</collection><collection>Engineered Materials Abstracts</collection><jtitle>Materials science & engineering. A, Structural materials : properties, microstructure and processing</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Yu, Z.L.</au><au>Li, S.X.</au><au>Liu, Y.Y.</au><au>Zhang, Q.Y.</au><au>Lei, J.F.</au><au>Mu, Z.X.</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Effect of surface treatments on fatigue life of Ti-6-22-22 alloy at room and high temperatures</atitle><jtitle>Materials science & engineering. A, Structural materials : properties, microstructure and processing</jtitle><date>2004-10-15</date><risdate>2004</risdate><volume>383</volume><issue>2</issue><spage>283</spage><epage>288</epage><pages>283-288</pages><issn>0921-5093</issn><eissn>1873-4936</eissn><abstract>Shot-peening and ion implantation were adopted to treat the surface of machined specimens of Ti-6-22-22 alloy, then stress-controlled fatigue tests were performed at room temperature and 400
°C. Experimental results indicate that the effects of shot-peening and ion implantation on the S–N curves are dependent on temperature. For Ti-6-22-22 alloy fatigued at room temperature, the effects of both, shot-peening and ion implantation of carbon ions on fatigue strength at high cyclic lives are slight. At 400
°C, the fatigue strength at high cyclic lives is obviously increased for both, shot-peening and ion implantation of carbon ions in comparison with the untreated counterparts.</abstract><pub>Elsevier B.V</pub><doi>10.1016/j.msea.2004.06.026</doi><tpages>6</tpages></addata></record> |
fulltext | fulltext |
identifier | ISSN: 0921-5093 |
ispartof | Materials science & engineering. A, Structural materials : properties, microstructure and processing, 2004-10, Vol.383 (2), p.283-288 |
issn | 0921-5093 1873-4936 |
language | eng |
recordid | cdi_proquest_miscellaneous_34780934 |
source | ScienceDirect Journals (5 years ago - present) |
subjects | Cracks initiation Ion implantation Shot-peening S–N curves Ti-6-22-22 alloy |
title | Effect of surface treatments on fatigue life of Ti-6-22-22 alloy at room and high temperatures |
url | https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-11T09%3A00%3A36IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_elsev&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Effect%20of%20surface%20treatments%20on%20fatigue%20life%20of%20Ti-6-22-22%20alloy%20at%20room%20and%20high%20temperatures&rft.jtitle=Materials%20science%20&%20engineering.%20A,%20Structural%20materials%20:%20properties,%20microstructure%20and%20processing&rft.au=Yu,%20Z.L.&rft.date=2004-10-15&rft.volume=383&rft.issue=2&rft.spage=283&rft.epage=288&rft.pages=283-288&rft.issn=0921-5093&rft.eissn=1873-4936&rft_id=info:doi/10.1016/j.msea.2004.06.026&rft_dat=%3Cproquest_elsev%3E28179844%3C/proquest_elsev%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=28179844&rft_id=info:pmid/&rft_els_id=S0921509304008524&rfr_iscdi=true |