A novel method to evaluate protein solubility using a high throughput screening approach

Protein solubility is a key parameter affecting the performance of every biotechnological downstream processing operation. Current methods used to determine protein solubility data, however, are often characterized by the need of pure protein crystals and long experimental time frames lying in the r...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Chemical engineering science 2009-09, Vol.64 (17), p.3778-3788
Hauptverfasser: Wiendahl, Matthias, Völker, Christiane, Husemann, Ilka, Krarup, Janus, Staby, Arne, Scholl, Stephan, Hubbuch, Jürgen
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 3788
container_issue 17
container_start_page 3778
container_title Chemical engineering science
container_volume 64
creator Wiendahl, Matthias
Völker, Christiane
Husemann, Ilka
Krarup, Janus
Staby, Arne
Scholl, Stephan
Hubbuch, Jürgen
description Protein solubility is a key parameter affecting the performance of every biotechnological downstream processing operation. Current methods used to determine protein solubility data, however, are often characterized by the need of pure protein crystals and long experimental time frames lying in the range of weeks to months, while other methods often fail to reach the solubility limits due to a too high dilution during the generation of the respective experimental solutions. This article presents an efficient, high throughput compatible method—based on photometric turbidity measurements—which allows a gentle and controlled concentration of the solution while constantly analyzing the solution state. All experimental tools were developed using the robotic liquid handling station Tecan Freedom Evo 200. The ability to combine sample concentration and solution state analysis acts as a basis for the determination of process relevant solubility phase diagrams and analysis of relevant kinetic effects during precipitation. Effects of several buffers on protein solubility and solubility curves of different insulin variants are shown as examples of relevant screening parameters.
doi_str_mv 10.1016/j.ces.2009.05.029
format Article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_34647867</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><els_id>S0009250909003364</els_id><sourcerecordid>34647867</sourcerecordid><originalsourceid>FETCH-LOGICAL-c395t-72780b638c6b16a5bc6f1d8dbe367e0076371ee4d74239662fe14063037f92cd3</originalsourceid><addsrcrecordid>eNp9UM1LwzAUD6LgnP4B3nLRW2vStEmLpzH8goEXBW8hTV_XjK6pSTrYf2_mhkdPj8fv670fQreUpJRQ_rBJNfg0I6RKSZGSrDpDM1oKluQ5Kc7RjEQkyQpSXaIr7zdxFYKSGfpa4MHuoMdbCJ1tcLAYdqqfVAA8OhvADNjbfqpNb8IeT94Ma6xwZ9YdDp2z07obp4C9dgDDLzZGmdLdNbpoVe_h5jTn6PP56WP5mqzeX96Wi1WiWVWERGSiJDVnpeY15aqoNW9pUzY1MC4gXsmZoAB5I_KMVZxnLdCccEaYaKtMN2yO7o--MfZ7Ah_k1ngNfa8GsJOXLOe5KLmIRHokame9d9DK0ZmtcntJiTx0KDcydigPHUpSyNhh1NydzJXXqm-dGrTxf8KMlrQieRF5j0cexE93Bpz02sCgoTEOdJCNNf-k_AB3UYcT</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>34647867</pqid></control><display><type>article</type><title>A novel method to evaluate protein solubility using a high throughput screening approach</title><source>Access via ScienceDirect (Elsevier)</source><creator>Wiendahl, Matthias ; Völker, Christiane ; Husemann, Ilka ; Krarup, Janus ; Staby, Arne ; Scholl, Stephan ; Hubbuch, Jürgen</creator><creatorcontrib>Wiendahl, Matthias ; Völker, Christiane ; Husemann, Ilka ; Krarup, Janus ; Staby, Arne ; Scholl, Stephan ; Hubbuch, Jürgen</creatorcontrib><description>Protein solubility is a key parameter affecting the performance of every biotechnological downstream processing operation. Current methods used to determine protein solubility data, however, are often characterized by the need of pure protein crystals and long experimental time frames lying in the range of weeks to months, while other methods often fail to reach the solubility limits due to a too high dilution during the generation of the respective experimental solutions. This article presents an efficient, high throughput compatible method—based on photometric turbidity measurements—which allows a gentle and controlled concentration of the solution while constantly analyzing the solution state. All experimental tools were developed using the robotic liquid handling station Tecan Freedom Evo 200. The ability to combine sample concentration and solution state analysis acts as a basis for the determination of process relevant solubility phase diagrams and analysis of relevant kinetic effects during precipitation. Effects of several buffers on protein solubility and solubility curves of different insulin variants are shown as examples of relevant screening parameters.</description><identifier>ISSN: 0009-2509</identifier><identifier>EISSN: 1873-4405</identifier><identifier>DOI: 10.1016/j.ces.2009.05.029</identifier><identifier>CODEN: CESCAC</identifier><language>eng</language><publisher>Kidlington: Elsevier Ltd</publisher><subject>Applied sciences ; Chemical engineering ; Evaporation ; Exact sciences and technology ; High throughput screening ; Insulin ; Precipitation ; Process development ; Protein solubility</subject><ispartof>Chemical engineering science, 2009-09, Vol.64 (17), p.3778-3788</ispartof><rights>2009 Elsevier Ltd</rights><rights>2009 INIST-CNRS</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c395t-72780b638c6b16a5bc6f1d8dbe367e0076371ee4d74239662fe14063037f92cd3</citedby><cites>FETCH-LOGICAL-c395t-72780b638c6b16a5bc6f1d8dbe367e0076371ee4d74239662fe14063037f92cd3</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://dx.doi.org/10.1016/j.ces.2009.05.029$$EHTML$$P50$$Gelsevier$$H</linktohtml><link.rule.ids>314,780,784,3550,27924,27925,45995</link.rule.ids><backlink>$$Uhttp://pascal-francis.inist.fr/vibad/index.php?action=getRecordDetail&amp;idt=21819045$$DView record in Pascal Francis$$Hfree_for_read</backlink></links><search><creatorcontrib>Wiendahl, Matthias</creatorcontrib><creatorcontrib>Völker, Christiane</creatorcontrib><creatorcontrib>Husemann, Ilka</creatorcontrib><creatorcontrib>Krarup, Janus</creatorcontrib><creatorcontrib>Staby, Arne</creatorcontrib><creatorcontrib>Scholl, Stephan</creatorcontrib><creatorcontrib>Hubbuch, Jürgen</creatorcontrib><title>A novel method to evaluate protein solubility using a high throughput screening approach</title><title>Chemical engineering science</title><description>Protein solubility is a key parameter affecting the performance of every biotechnological downstream processing operation. Current methods used to determine protein solubility data, however, are often characterized by the need of pure protein crystals and long experimental time frames lying in the range of weeks to months, while other methods often fail to reach the solubility limits due to a too high dilution during the generation of the respective experimental solutions. This article presents an efficient, high throughput compatible method—based on photometric turbidity measurements—which allows a gentle and controlled concentration of the solution while constantly analyzing the solution state. All experimental tools were developed using the robotic liquid handling station Tecan Freedom Evo 200. The ability to combine sample concentration and solution state analysis acts as a basis for the determination of process relevant solubility phase diagrams and analysis of relevant kinetic effects during precipitation. Effects of several buffers on protein solubility and solubility curves of different insulin variants are shown as examples of relevant screening parameters.</description><subject>Applied sciences</subject><subject>Chemical engineering</subject><subject>Evaporation</subject><subject>Exact sciences and technology</subject><subject>High throughput screening</subject><subject>Insulin</subject><subject>Precipitation</subject><subject>Process development</subject><subject>Protein solubility</subject><issn>0009-2509</issn><issn>1873-4405</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2009</creationdate><recordtype>article</recordtype><recordid>eNp9UM1LwzAUD6LgnP4B3nLRW2vStEmLpzH8goEXBW8hTV_XjK6pSTrYf2_mhkdPj8fv670fQreUpJRQ_rBJNfg0I6RKSZGSrDpDM1oKluQ5Kc7RjEQkyQpSXaIr7zdxFYKSGfpa4MHuoMdbCJ1tcLAYdqqfVAA8OhvADNjbfqpNb8IeT94Ma6xwZ9YdDp2z07obp4C9dgDDLzZGmdLdNbpoVe_h5jTn6PP56WP5mqzeX96Wi1WiWVWERGSiJDVnpeY15aqoNW9pUzY1MC4gXsmZoAB5I_KMVZxnLdCccEaYaKtMN2yO7o--MfZ7Ah_k1ngNfa8GsJOXLOe5KLmIRHokame9d9DK0ZmtcntJiTx0KDcydigPHUpSyNhh1NydzJXXqm-dGrTxf8KMlrQieRF5j0cexE93Bpz02sCgoTEOdJCNNf-k_AB3UYcT</recordid><startdate>20090901</startdate><enddate>20090901</enddate><creator>Wiendahl, Matthias</creator><creator>Völker, Christiane</creator><creator>Husemann, Ilka</creator><creator>Krarup, Janus</creator><creator>Staby, Arne</creator><creator>Scholl, Stephan</creator><creator>Hubbuch, Jürgen</creator><general>Elsevier Ltd</general><general>Elsevier</general><scope>IQODW</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7U5</scope><scope>8FD</scope><scope>F28</scope><scope>FR3</scope><scope>L7M</scope></search><sort><creationdate>20090901</creationdate><title>A novel method to evaluate protein solubility using a high throughput screening approach</title><author>Wiendahl, Matthias ; Völker, Christiane ; Husemann, Ilka ; Krarup, Janus ; Staby, Arne ; Scholl, Stephan ; Hubbuch, Jürgen</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c395t-72780b638c6b16a5bc6f1d8dbe367e0076371ee4d74239662fe14063037f92cd3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2009</creationdate><topic>Applied sciences</topic><topic>Chemical engineering</topic><topic>Evaporation</topic><topic>Exact sciences and technology</topic><topic>High throughput screening</topic><topic>Insulin</topic><topic>Precipitation</topic><topic>Process development</topic><topic>Protein solubility</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Wiendahl, Matthias</creatorcontrib><creatorcontrib>Völker, Christiane</creatorcontrib><creatorcontrib>Husemann, Ilka</creatorcontrib><creatorcontrib>Krarup, Janus</creatorcontrib><creatorcontrib>Staby, Arne</creatorcontrib><creatorcontrib>Scholl, Stephan</creatorcontrib><creatorcontrib>Hubbuch, Jürgen</creatorcontrib><collection>Pascal-Francis</collection><collection>CrossRef</collection><collection>Solid State and Superconductivity Abstracts</collection><collection>Technology Research Database</collection><collection>ANTE: Abstracts in New Technology &amp; Engineering</collection><collection>Engineering Research Database</collection><collection>Advanced Technologies Database with Aerospace</collection><jtitle>Chemical engineering science</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Wiendahl, Matthias</au><au>Völker, Christiane</au><au>Husemann, Ilka</au><au>Krarup, Janus</au><au>Staby, Arne</au><au>Scholl, Stephan</au><au>Hubbuch, Jürgen</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>A novel method to evaluate protein solubility using a high throughput screening approach</atitle><jtitle>Chemical engineering science</jtitle><date>2009-09-01</date><risdate>2009</risdate><volume>64</volume><issue>17</issue><spage>3778</spage><epage>3788</epage><pages>3778-3788</pages><issn>0009-2509</issn><eissn>1873-4405</eissn><coden>CESCAC</coden><abstract>Protein solubility is a key parameter affecting the performance of every biotechnological downstream processing operation. Current methods used to determine protein solubility data, however, are often characterized by the need of pure protein crystals and long experimental time frames lying in the range of weeks to months, while other methods often fail to reach the solubility limits due to a too high dilution during the generation of the respective experimental solutions. This article presents an efficient, high throughput compatible method—based on photometric turbidity measurements—which allows a gentle and controlled concentration of the solution while constantly analyzing the solution state. All experimental tools were developed using the robotic liquid handling station Tecan Freedom Evo 200. The ability to combine sample concentration and solution state analysis acts as a basis for the determination of process relevant solubility phase diagrams and analysis of relevant kinetic effects during precipitation. Effects of several buffers on protein solubility and solubility curves of different insulin variants are shown as examples of relevant screening parameters.</abstract><cop>Kidlington</cop><pub>Elsevier Ltd</pub><doi>10.1016/j.ces.2009.05.029</doi><tpages>11</tpages></addata></record>
fulltext fulltext
identifier ISSN: 0009-2509
ispartof Chemical engineering science, 2009-09, Vol.64 (17), p.3778-3788
issn 0009-2509
1873-4405
language eng
recordid cdi_proquest_miscellaneous_34647867
source Access via ScienceDirect (Elsevier)
subjects Applied sciences
Chemical engineering
Evaporation
Exact sciences and technology
High throughput screening
Insulin
Precipitation
Process development
Protein solubility
title A novel method to evaluate protein solubility using a high throughput screening approach
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-01T03%3A56%3A19IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=A%20novel%20method%20to%20evaluate%20protein%20solubility%20using%20a%20high%20throughput%20screening%20approach&rft.jtitle=Chemical%20engineering%20science&rft.au=Wiendahl,%20Matthias&rft.date=2009-09-01&rft.volume=64&rft.issue=17&rft.spage=3778&rft.epage=3788&rft.pages=3778-3788&rft.issn=0009-2509&rft.eissn=1873-4405&rft.coden=CESCAC&rft_id=info:doi/10.1016/j.ces.2009.05.029&rft_dat=%3Cproquest_cross%3E34647867%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=34647867&rft_id=info:pmid/&rft_els_id=S0009250909003364&rfr_iscdi=true