3D EIT for breast cancer imaging: System, measurements, and reconstruction
Electrical impedance tomography (EIT) is a developing imaging modality for early detection of breast cancer. In an EIT system, a low‐frequency current is applied sequentially between different electrode pairs while voltage measurements are made at other electrodes to arrive at the electrical impedan...
Gespeichert in:
Veröffentlicht in: | Microwave and optical technology letters 2008-12, Vol.50 (12), p.3261-3271 |
---|---|
Hauptverfasser: | , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
container_end_page | 3271 |
---|---|
container_issue | 12 |
container_start_page | 3261 |
container_title | Microwave and optical technology letters |
container_volume | 50 |
creator | Ye, Gang Lim, Kim Hwa George Jr, Rhett T. Ybarra, Gary A. Joines, William T. Liu, Qing Huo |
description | Electrical impedance tomography (EIT) is a developing imaging modality for early detection of breast cancer. In an EIT system, a low‐frequency current is applied sequentially between different electrode pairs while voltage measurements are made at other electrodes to arrive at the electrical impedance values. The set of impedance measurement data is then computed to produce a 3D electrical conductivity map of the volume to be imaged. In this work, the design, measurements, and inversion of a full 3D EIT system are discussed. Experimentally determined EIT images of phantom objects are presented. © 2008 Wiley Periodicals, Inc. Microwave Opt Technol Lett 50: 3261–3271, 2008; Published online in Wiley InterScience (www.interscience.wiley.com). DOI 10.1002/mop.23932 |
doi_str_mv | 10.1002/mop.23932 |
format | Article |
fullrecord | <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_34646215</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>34646215</sourcerecordid><originalsourceid>FETCH-LOGICAL-c4042-7d6125ec82501c8d2b3ef1bcf2d0aa957c1ced9eedb6c2a967eeb3ff78ed34f13</originalsourceid><addsrcrecordid>eNp1kMtOwzAQAC0EEqVw4A98QkIirR9JnHCDUkpRoaAW0ZvlOOsqkEexE0H_nkCAG6c97MxKOwgdUzKghLBhUW0GjMec7aAeJXHkMRGSXdQjURx4zBdiHx0490II4UKwHrrlV3g8XWJTWZxYUK7GWpUaLM4Ktc7K9TlebF0NxRku2m1joYCydmdYlSm2oKvS1bbRdVaVh2jPqNzB0c_so6fr8XJ0483mk-noYuZpn_jME2lIWQA6YgGhOkpZwsHQRBuWEqXiQGiqIY0B0iTUTMWhAEi4MSKClPuG8j466e5ubPXWgKtlkTkNea5KqBonuR_6IaNBC552oLaVcxaM3Nj2K7uVlMivWrKtJb9rteywY9-zHLb_g_Ju_vBreJ2RtXk-_gxlX2UouAjk8_1ErhaPwWoUX0rOPwGTy3uw</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>34646215</pqid></control><display><type>article</type><title>3D EIT for breast cancer imaging: System, measurements, and reconstruction</title><source>Wiley Journals</source><creator>Ye, Gang ; Lim, Kim Hwa ; George Jr, Rhett T. ; Ybarra, Gary A. ; Joines, William T. ; Liu, Qing Huo</creator><creatorcontrib>Ye, Gang ; Lim, Kim Hwa ; George Jr, Rhett T. ; Ybarra, Gary A. ; Joines, William T. ; Liu, Qing Huo</creatorcontrib><description>Electrical impedance tomography (EIT) is a developing imaging modality for early detection of breast cancer. In an EIT system, a low‐frequency current is applied sequentially between different electrode pairs while voltage measurements are made at other electrodes to arrive at the electrical impedance values. The set of impedance measurement data is then computed to produce a 3D electrical conductivity map of the volume to be imaged. In this work, the design, measurements, and inversion of a full 3D EIT system are discussed. Experimentally determined EIT images of phantom objects are presented. © 2008 Wiley Periodicals, Inc. Microwave Opt Technol Lett 50: 3261–3271, 2008; Published online in Wiley InterScience (www.interscience.wiley.com). DOI 10.1002/mop.23932</description><identifier>ISSN: 0895-2477</identifier><identifier>EISSN: 1098-2760</identifier><identifier>DOI: 10.1002/mop.23932</identifier><language>eng</language><publisher>Hoboken: Wiley Subscription Services, Inc., A Wiley Company</publisher><subject>breast cancer detection ; breast cancer imaging ; EIT ; electrical impedance tomography ; imaging ; inversion ; spectral element method</subject><ispartof>Microwave and optical technology letters, 2008-12, Vol.50 (12), p.3261-3271</ispartof><rights>Copyright © 2008 Wiley Periodicals, Inc.</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c4042-7d6125ec82501c8d2b3ef1bcf2d0aa957c1ced9eedb6c2a967eeb3ff78ed34f13</citedby><cites>FETCH-LOGICAL-c4042-7d6125ec82501c8d2b3ef1bcf2d0aa957c1ced9eedb6c2a967eeb3ff78ed34f13</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktopdf>$$Uhttps://onlinelibrary.wiley.com/doi/pdf/10.1002%2Fmop.23932$$EPDF$$P50$$Gwiley$$H</linktopdf><linktohtml>$$Uhttps://onlinelibrary.wiley.com/doi/full/10.1002%2Fmop.23932$$EHTML$$P50$$Gwiley$$H</linktohtml><link.rule.ids>314,780,784,1417,27924,27925,45574,45575</link.rule.ids></links><search><creatorcontrib>Ye, Gang</creatorcontrib><creatorcontrib>Lim, Kim Hwa</creatorcontrib><creatorcontrib>George Jr, Rhett T.</creatorcontrib><creatorcontrib>Ybarra, Gary A.</creatorcontrib><creatorcontrib>Joines, William T.</creatorcontrib><creatorcontrib>Liu, Qing Huo</creatorcontrib><title>3D EIT for breast cancer imaging: System, measurements, and reconstruction</title><title>Microwave and optical technology letters</title><addtitle>Microw. Opt. Technol. Lett</addtitle><description>Electrical impedance tomography (EIT) is a developing imaging modality for early detection of breast cancer. In an EIT system, a low‐frequency current is applied sequentially between different electrode pairs while voltage measurements are made at other electrodes to arrive at the electrical impedance values. The set of impedance measurement data is then computed to produce a 3D electrical conductivity map of the volume to be imaged. In this work, the design, measurements, and inversion of a full 3D EIT system are discussed. Experimentally determined EIT images of phantom objects are presented. © 2008 Wiley Periodicals, Inc. Microwave Opt Technol Lett 50: 3261–3271, 2008; Published online in Wiley InterScience (www.interscience.wiley.com). DOI 10.1002/mop.23932</description><subject>breast cancer detection</subject><subject>breast cancer imaging</subject><subject>EIT</subject><subject>electrical impedance tomography</subject><subject>imaging</subject><subject>inversion</subject><subject>spectral element method</subject><issn>0895-2477</issn><issn>1098-2760</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2008</creationdate><recordtype>article</recordtype><recordid>eNp1kMtOwzAQAC0EEqVw4A98QkIirR9JnHCDUkpRoaAW0ZvlOOsqkEexE0H_nkCAG6c97MxKOwgdUzKghLBhUW0GjMec7aAeJXHkMRGSXdQjURx4zBdiHx0490II4UKwHrrlV3g8XWJTWZxYUK7GWpUaLM4Ktc7K9TlebF0NxRku2m1joYCydmdYlSm2oKvS1bbRdVaVh2jPqNzB0c_so6fr8XJ0483mk-noYuZpn_jME2lIWQA6YgGhOkpZwsHQRBuWEqXiQGiqIY0B0iTUTMWhAEi4MSKClPuG8j466e5ubPXWgKtlkTkNea5KqBonuR_6IaNBC552oLaVcxaM3Nj2K7uVlMivWrKtJb9rteywY9-zHLb_g_Ju_vBreJ2RtXk-_gxlX2UouAjk8_1ErhaPwWoUX0rOPwGTy3uw</recordid><startdate>200812</startdate><enddate>200812</enddate><creator>Ye, Gang</creator><creator>Lim, Kim Hwa</creator><creator>George Jr, Rhett T.</creator><creator>Ybarra, Gary A.</creator><creator>Joines, William T.</creator><creator>Liu, Qing Huo</creator><general>Wiley Subscription Services, Inc., A Wiley Company</general><scope>BSCLL</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7SP</scope><scope>8FD</scope><scope>L7M</scope></search><sort><creationdate>200812</creationdate><title>3D EIT for breast cancer imaging: System, measurements, and reconstruction</title><author>Ye, Gang ; Lim, Kim Hwa ; George Jr, Rhett T. ; Ybarra, Gary A. ; Joines, William T. ; Liu, Qing Huo</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c4042-7d6125ec82501c8d2b3ef1bcf2d0aa957c1ced9eedb6c2a967eeb3ff78ed34f13</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2008</creationdate><topic>breast cancer detection</topic><topic>breast cancer imaging</topic><topic>EIT</topic><topic>electrical impedance tomography</topic><topic>imaging</topic><topic>inversion</topic><topic>spectral element method</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Ye, Gang</creatorcontrib><creatorcontrib>Lim, Kim Hwa</creatorcontrib><creatorcontrib>George Jr, Rhett T.</creatorcontrib><creatorcontrib>Ybarra, Gary A.</creatorcontrib><creatorcontrib>Joines, William T.</creatorcontrib><creatorcontrib>Liu, Qing Huo</creatorcontrib><collection>Istex</collection><collection>CrossRef</collection><collection>Electronics & Communications Abstracts</collection><collection>Technology Research Database</collection><collection>Advanced Technologies Database with Aerospace</collection><jtitle>Microwave and optical technology letters</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Ye, Gang</au><au>Lim, Kim Hwa</au><au>George Jr, Rhett T.</au><au>Ybarra, Gary A.</au><au>Joines, William T.</au><au>Liu, Qing Huo</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>3D EIT for breast cancer imaging: System, measurements, and reconstruction</atitle><jtitle>Microwave and optical technology letters</jtitle><addtitle>Microw. Opt. Technol. Lett</addtitle><date>2008-12</date><risdate>2008</risdate><volume>50</volume><issue>12</issue><spage>3261</spage><epage>3271</epage><pages>3261-3271</pages><issn>0895-2477</issn><eissn>1098-2760</eissn><abstract>Electrical impedance tomography (EIT) is a developing imaging modality for early detection of breast cancer. In an EIT system, a low‐frequency current is applied sequentially between different electrode pairs while voltage measurements are made at other electrodes to arrive at the electrical impedance values. The set of impedance measurement data is then computed to produce a 3D electrical conductivity map of the volume to be imaged. In this work, the design, measurements, and inversion of a full 3D EIT system are discussed. Experimentally determined EIT images of phantom objects are presented. © 2008 Wiley Periodicals, Inc. Microwave Opt Technol Lett 50: 3261–3271, 2008; Published online in Wiley InterScience (www.interscience.wiley.com). DOI 10.1002/mop.23932</abstract><cop>Hoboken</cop><pub>Wiley Subscription Services, Inc., A Wiley Company</pub><doi>10.1002/mop.23932</doi><tpages>11</tpages></addata></record> |
fulltext | fulltext |
identifier | ISSN: 0895-2477 |
ispartof | Microwave and optical technology letters, 2008-12, Vol.50 (12), p.3261-3271 |
issn | 0895-2477 1098-2760 |
language | eng |
recordid | cdi_proquest_miscellaneous_34646215 |
source | Wiley Journals |
subjects | breast cancer detection breast cancer imaging EIT electrical impedance tomography imaging inversion spectral element method |
title | 3D EIT for breast cancer imaging: System, measurements, and reconstruction |
url | https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-03T00%3A05%3A31IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=3D%20EIT%20for%20breast%20cancer%20imaging:%20System,%20measurements,%20and%20reconstruction&rft.jtitle=Microwave%20and%20optical%20technology%20letters&rft.au=Ye,%20Gang&rft.date=2008-12&rft.volume=50&rft.issue=12&rft.spage=3261&rft.epage=3271&rft.pages=3261-3271&rft.issn=0895-2477&rft.eissn=1098-2760&rft_id=info:doi/10.1002/mop.23932&rft_dat=%3Cproquest_cross%3E34646215%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=34646215&rft_id=info:pmid/&rfr_iscdi=true |