VOCs MEASUREMENT USING SAMPLING BAG

In the improvement of the air quality of indoors, it is necessary to determine the kind and the concentration of the chemical substances that emit from building products and production parts. In this paper, the investigation of the following three items was executed. 1. The background concentration...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Journal of Environmental Engineering (Transactions of AIJ) 2008/07/30, Vol.73(629), pp.911-916
Hauptverfasser: TATSU, Kouichi, TANABE, Shin-ichi, HOSHINO, Kunihiro, SATO, Katsuji
Format: Artikel
Sprache:jpn
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 916
container_issue 629
container_start_page 911
container_title Journal of Environmental Engineering (Transactions of AIJ)
container_volume 73
creator TATSU, Kouichi
TANABE, Shin-ichi
HOSHINO, Kunihiro
SATO, Katsuji
description In the improvement of the air quality of indoors, it is necessary to determine the kind and the concentration of the chemical substances that emit from building products and production parts. In this paper, the investigation of the following three items was executed. 1. The background concentration and the background substances of three kinds of bags (PVF, FEP, ALF) were evaluated. 2. A standard solution was dropped to the bag and the collection rate of each VOC substances was measured. 3. The calculation of the Emission rate was tried by measuring VOC emitted from permeate tube using the Bag method. In these experiments we found that the background concentration of FEP was the lowest in three kinds of bags. It was confirmed that collection rate of DEHP was low. But Some VOCs such as toluene was a high collection rate. Moreover, emission rate from the bag method is steady from stirring it when sampling it.
doi_str_mv 10.3130/aije.73.911
format Article
fullrecord <record><control><sourceid>proquest_jstag</sourceid><recordid>TN_cdi_proquest_miscellaneous_34626889</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>34626889</sourcerecordid><originalsourceid>FETCH-LOGICAL-j251t-e7d8ec8e4b310dc45da87a59c4b89b52c20c4cc17afd621f58e070967f5b553d3</originalsourceid><addsrcrecordid>eNo9kEtLw0AYRQdRsNSu_AMBwV3qfDOZR5axprGQtmIacTdMJhNNSB9m0oX_3pSqq3PgXu7iInQLeEqB4gddN3Yq6DQEuEAjkBJ8CeL9cnAaSB9zya7RxLm6wIQCx5zDCN29rWfOW8ZRlr_Gy3i18fJssUq8LFq-pCd5jJIbdFXp1tnJL8con8eb2bOfrpPFLEr9hjDofStKaY20QUEBlyZgpZZCs9AEhQwLRgzBJjAGhK5KTqBi0mKBQy4qVjBGSzpG9-fdQ7f_OlrXq23tjG1bvbP7o1M04IRLGQ7Fp3Oxcb3-sOrQ1VvdfSvd9bVprTo9oQRVnIR_GE75j82n7pTd0R-dMVem</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>34626889</pqid></control><display><type>article</type><title>VOCs MEASUREMENT USING SAMPLING BAG</title><source>J-STAGE (Japan Science &amp; Technology Information Aggregator, Electronic) Freely Available Titles - Japanese</source><source>EZB-FREE-00999 freely available EZB journals</source><creator>TATSU, Kouichi ; TANABE, Shin-ichi ; HOSHINO, Kunihiro ; SATO, Katsuji</creator><creatorcontrib>TATSU, Kouichi ; TANABE, Shin-ichi ; HOSHINO, Kunihiro ; SATO, Katsuji</creatorcontrib><description>In the improvement of the air quality of indoors, it is necessary to determine the kind and the concentration of the chemical substances that emit from building products and production parts. In this paper, the investigation of the following three items was executed. 1. The background concentration and the background substances of three kinds of bags (PVF, FEP, ALF) were evaluated. 2. A standard solution was dropped to the bag and the collection rate of each VOC substances was measured. 3. The calculation of the Emission rate was tried by measuring VOC emitted from permeate tube using the Bag method. In these experiments we found that the background concentration of FEP was the lowest in three kinds of bags. It was confirmed that collection rate of DEHP was low. But Some VOCs such as toluene was a high collection rate. Moreover, emission rate from the bag method is steady from stirring it when sampling it.</description><identifier>ISSN: 1348-0685</identifier><identifier>EISSN: 1881-817X</identifier><identifier>DOI: 10.3130/aije.73.911</identifier><language>jpn</language><publisher>Architectural Institute of Japan</publisher><subject>Bag method ; Emission Rate ; Ventilation Rate ; VOC</subject><ispartof>Journal of Environmental Engineering (Transactions of AIJ), 2008/07/30, Vol.73(629), pp.911-916</ispartof><rights>2008 Architectural Institute of Japan</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,780,784,1883,27924,27925</link.rule.ids></links><search><creatorcontrib>TATSU, Kouichi</creatorcontrib><creatorcontrib>TANABE, Shin-ichi</creatorcontrib><creatorcontrib>HOSHINO, Kunihiro</creatorcontrib><creatorcontrib>SATO, Katsuji</creatorcontrib><title>VOCs MEASUREMENT USING SAMPLING BAG</title><title>Journal of Environmental Engineering (Transactions of AIJ)</title><addtitle>J. Environ. Eng.</addtitle><description>In the improvement of the air quality of indoors, it is necessary to determine the kind and the concentration of the chemical substances that emit from building products and production parts. In this paper, the investigation of the following three items was executed. 1. The background concentration and the background substances of three kinds of bags (PVF, FEP, ALF) were evaluated. 2. A standard solution was dropped to the bag and the collection rate of each VOC substances was measured. 3. The calculation of the Emission rate was tried by measuring VOC emitted from permeate tube using the Bag method. In these experiments we found that the background concentration of FEP was the lowest in three kinds of bags. It was confirmed that collection rate of DEHP was low. But Some VOCs such as toluene was a high collection rate. Moreover, emission rate from the bag method is steady from stirring it when sampling it.</description><subject>Bag method</subject><subject>Emission Rate</subject><subject>Ventilation Rate</subject><subject>VOC</subject><issn>1348-0685</issn><issn>1881-817X</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2008</creationdate><recordtype>article</recordtype><recordid>eNo9kEtLw0AYRQdRsNSu_AMBwV3qfDOZR5axprGQtmIacTdMJhNNSB9m0oX_3pSqq3PgXu7iInQLeEqB4gddN3Yq6DQEuEAjkBJ8CeL9cnAaSB9zya7RxLm6wIQCx5zDCN29rWfOW8ZRlr_Gy3i18fJssUq8LFq-pCd5jJIbdFXp1tnJL8con8eb2bOfrpPFLEr9hjDofStKaY20QUEBlyZgpZZCs9AEhQwLRgzBJjAGhK5KTqBi0mKBQy4qVjBGSzpG9-fdQ7f_OlrXq23tjG1bvbP7o1M04IRLGQ7Fp3Oxcb3-sOrQ1VvdfSvd9bVprTo9oQRVnIR_GE75j82n7pTd0R-dMVem</recordid><startdate>200807</startdate><enddate>200807</enddate><creator>TATSU, Kouichi</creator><creator>TANABE, Shin-ichi</creator><creator>HOSHINO, Kunihiro</creator><creator>SATO, Katsuji</creator><general>Architectural Institute of Japan</general><scope>8FD</scope><scope>FR3</scope><scope>KR7</scope></search><sort><creationdate>200807</creationdate><title>VOCs MEASUREMENT USING SAMPLING BAG</title><author>TATSU, Kouichi ; TANABE, Shin-ichi ; HOSHINO, Kunihiro ; SATO, Katsuji</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-j251t-e7d8ec8e4b310dc45da87a59c4b89b52c20c4cc17afd621f58e070967f5b553d3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>jpn</language><creationdate>2008</creationdate><topic>Bag method</topic><topic>Emission Rate</topic><topic>Ventilation Rate</topic><topic>VOC</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>TATSU, Kouichi</creatorcontrib><creatorcontrib>TANABE, Shin-ichi</creatorcontrib><creatorcontrib>HOSHINO, Kunihiro</creatorcontrib><creatorcontrib>SATO, Katsuji</creatorcontrib><collection>Technology Research Database</collection><collection>Engineering Research Database</collection><collection>Civil Engineering Abstracts</collection><jtitle>Journal of Environmental Engineering (Transactions of AIJ)</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>TATSU, Kouichi</au><au>TANABE, Shin-ichi</au><au>HOSHINO, Kunihiro</au><au>SATO, Katsuji</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>VOCs MEASUREMENT USING SAMPLING BAG</atitle><jtitle>Journal of Environmental Engineering (Transactions of AIJ)</jtitle><addtitle>J. Environ. Eng.</addtitle><date>2008-07</date><risdate>2008</risdate><volume>73</volume><issue>629</issue><spage>911</spage><epage>916</epage><pages>911-916</pages><issn>1348-0685</issn><eissn>1881-817X</eissn><abstract>In the improvement of the air quality of indoors, it is necessary to determine the kind and the concentration of the chemical substances that emit from building products and production parts. In this paper, the investigation of the following three items was executed. 1. The background concentration and the background substances of three kinds of bags (PVF, FEP, ALF) were evaluated. 2. A standard solution was dropped to the bag and the collection rate of each VOC substances was measured. 3. The calculation of the Emission rate was tried by measuring VOC emitted from permeate tube using the Bag method. In these experiments we found that the background concentration of FEP was the lowest in three kinds of bags. It was confirmed that collection rate of DEHP was low. But Some VOCs such as toluene was a high collection rate. Moreover, emission rate from the bag method is steady from stirring it when sampling it.</abstract><pub>Architectural Institute of Japan</pub><doi>10.3130/aije.73.911</doi><tpages>6</tpages><oa>free_for_read</oa></addata></record>
fulltext fulltext
identifier ISSN: 1348-0685
ispartof Journal of Environmental Engineering (Transactions of AIJ), 2008/07/30, Vol.73(629), pp.911-916
issn 1348-0685
1881-817X
language jpn
recordid cdi_proquest_miscellaneous_34626889
source J-STAGE (Japan Science & Technology Information Aggregator, Electronic) Freely Available Titles - Japanese; EZB-FREE-00999 freely available EZB journals
subjects Bag method
Emission Rate
Ventilation Rate
VOC
title VOCs MEASUREMENT USING SAMPLING BAG
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-23T09%3A12%3A51IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_jstag&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=VOCs%20MEASUREMENT%20USING%20SAMPLING%20BAG&rft.jtitle=Journal%20of%20Environmental%20Engineering%20(Transactions%20of%20AIJ)&rft.au=TATSU,%20Kouichi&rft.date=2008-07&rft.volume=73&rft.issue=629&rft.spage=911&rft.epage=916&rft.pages=911-916&rft.issn=1348-0685&rft.eissn=1881-817X&rft_id=info:doi/10.3130/aije.73.911&rft_dat=%3Cproquest_jstag%3E34626889%3C/proquest_jstag%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=34626889&rft_id=info:pmid/&rfr_iscdi=true