Line laser beam based laser-induced fluorescence detection system for microfluidic chip electrophoresis analysis
In this work, a new laser-induced fluorescence (LIF) detection system based on a line laser beam for microfluidic chip electrophoresis analysis was developed. This detection system had the advantages of simple optical structure, compactness, and ease in constructing. Highly sensitive detection was r...
Gespeichert in:
Veröffentlicht in: | Sensors and actuators. A. Physical. 2009-06, Vol.152 (2), p.168-175 |
---|---|
Hauptverfasser: | , , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
container_end_page | 175 |
---|---|
container_issue | 2 |
container_start_page | 168 |
container_title | Sensors and actuators. A. Physical. |
container_volume | 152 |
creator | Xu, Baojian Yang, Mo Wang, Hua Zhang, Honglian Jin, Qinghui Zhao, Jianlong Wang, Huimin |
description | In this work, a new laser-induced fluorescence (LIF) detection system based on a line laser beam for microfluidic chip electrophoresis analysis was developed. This detection system had the advantages of simple optical structure, compactness, and ease in constructing. Highly sensitive detection was realized by detecting the fluorescence light emitted in the micro-channel through the vertical intersection between the line laser source and micro-channel. The filtered line source was established by a bevel laser beam and a micro-gap which could facilitate the alignment of line laser beam with the microfluidic channel. Both the theoretical analysis and experimental study demonstrated that the detection system with a 0.07 mm-width micro-gap had enough sensitivity and adequate separation efficiency. By this system, a detection limit (S/N
>
12) of 1.284
×
10
−10
M fluorescein isothiocyanate was obtained, and the plate number could reach to 6100, which were comparable to those of optimized confocal or orthogonal LIF systems for microchip based capillary electrophoresis. The reproductibility of the detection system was evaluated by Sybr Green labeled DNA markers contained five fragments. Finally, the multi-PCR products including 165
bp, 266
bp, 378
bp and 881
bp fragments could be successfully achieved for baseline separation by this system within 4
min. The work undertaken can gear toward a semi-automated handheld system with substantial time and cost saving. |
doi_str_mv | 10.1016/j.sna.2009.04.005 |
format | Article |
fullrecord | <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_34494093</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><els_id>S0924424709001812</els_id><sourcerecordid>34494093</sourcerecordid><originalsourceid>FETCH-LOGICAL-c328t-10ed2bf8c12fad631d84ffa1fe5aa42e2c8e2850fb05b110f5c5d2098565678b3</originalsourceid><addsrcrecordid>eNp9kElLBDEQhYMoOI7-AG85eeu2svSGJxE3GPCi55BOKkyG3ky6hfn3ZmjPnupV8V7B-wi5ZZAzYOX9IY-DzjlAk4PMAYozsmF1JTIBZXNONtBwmUkuq0tyFeMBAISoqg2Zdn5A2umIgbaoe9omaddD5ge7mLS5bhkDRoODQWpxRjP7caDxGGfsqRsD7b0JY7J56w01ez9R7JIrjNP-lPSR6kF3xySuyYXTXcSbv7klXy_Pn09v2e7j9f3pcZcZwes5Y4CWt642jDttS8FsLZ3TzGGhteTITY28LsC1ULSMgStMYTk0dVEWZVW3Ykvu1r9TGL8XjLPqfWrQdXrAcYlKSNlIaEQystWYGsQY0Kkp-F6Ho2KgTmzVQSW26sRWgVSJbco8rBlMDX48BhWNP9GxPqTayo7-n_QvmaWE3g</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>34494093</pqid></control><display><type>article</type><title>Line laser beam based laser-induced fluorescence detection system for microfluidic chip electrophoresis analysis</title><source>ScienceDirect Journals (5 years ago - present)</source><creator>Xu, Baojian ; Yang, Mo ; Wang, Hua ; Zhang, Honglian ; Jin, Qinghui ; Zhao, Jianlong ; Wang, Huimin</creator><creatorcontrib>Xu, Baojian ; Yang, Mo ; Wang, Hua ; Zhang, Honglian ; Jin, Qinghui ; Zhao, Jianlong ; Wang, Huimin</creatorcontrib><description>In this work, a new laser-induced fluorescence (LIF) detection system based on a line laser beam for microfluidic chip electrophoresis analysis was developed. This detection system had the advantages of simple optical structure, compactness, and ease in constructing. Highly sensitive detection was realized by detecting the fluorescence light emitted in the micro-channel through the vertical intersection between the line laser source and micro-channel. The filtered line source was established by a bevel laser beam and a micro-gap which could facilitate the alignment of line laser beam with the microfluidic channel. Both the theoretical analysis and experimental study demonstrated that the detection system with a 0.07 mm-width micro-gap had enough sensitivity and adequate separation efficiency. By this system, a detection limit (S/N
>
12) of 1.284
×
10
−10
M fluorescein isothiocyanate was obtained, and the plate number could reach to 6100, which were comparable to those of optimized confocal or orthogonal LIF systems for microchip based capillary electrophoresis. The reproductibility of the detection system was evaluated by Sybr Green labeled DNA markers contained five fragments. Finally, the multi-PCR products including 165
bp, 266
bp, 378
bp and 881
bp fragments could be successfully achieved for baseline separation by this system within 4
min. The work undertaken can gear toward a semi-automated handheld system with substantial time and cost saving.</description><identifier>ISSN: 0924-4247</identifier><identifier>EISSN: 1873-3069</identifier><identifier>DOI: 10.1016/j.sna.2009.04.005</identifier><language>eng</language><publisher>Elsevier B.V</publisher><subject>Electrophoresis ; Laser-induced fluorescence ; Line laser beam ; Microfluidic chip</subject><ispartof>Sensors and actuators. A. Physical., 2009-06, Vol.152 (2), p.168-175</ispartof><rights>2009 Elsevier B.V.</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c328t-10ed2bf8c12fad631d84ffa1fe5aa42e2c8e2850fb05b110f5c5d2098565678b3</citedby><cites>FETCH-LOGICAL-c328t-10ed2bf8c12fad631d84ffa1fe5aa42e2c8e2850fb05b110f5c5d2098565678b3</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://dx.doi.org/10.1016/j.sna.2009.04.005$$EHTML$$P50$$Gelsevier$$H</linktohtml><link.rule.ids>314,778,782,3539,27913,27914,45984</link.rule.ids></links><search><creatorcontrib>Xu, Baojian</creatorcontrib><creatorcontrib>Yang, Mo</creatorcontrib><creatorcontrib>Wang, Hua</creatorcontrib><creatorcontrib>Zhang, Honglian</creatorcontrib><creatorcontrib>Jin, Qinghui</creatorcontrib><creatorcontrib>Zhao, Jianlong</creatorcontrib><creatorcontrib>Wang, Huimin</creatorcontrib><title>Line laser beam based laser-induced fluorescence detection system for microfluidic chip electrophoresis analysis</title><title>Sensors and actuators. A. Physical.</title><description>In this work, a new laser-induced fluorescence (LIF) detection system based on a line laser beam for microfluidic chip electrophoresis analysis was developed. This detection system had the advantages of simple optical structure, compactness, and ease in constructing. Highly sensitive detection was realized by detecting the fluorescence light emitted in the micro-channel through the vertical intersection between the line laser source and micro-channel. The filtered line source was established by a bevel laser beam and a micro-gap which could facilitate the alignment of line laser beam with the microfluidic channel. Both the theoretical analysis and experimental study demonstrated that the detection system with a 0.07 mm-width micro-gap had enough sensitivity and adequate separation efficiency. By this system, a detection limit (S/N
>
12) of 1.284
×
10
−10
M fluorescein isothiocyanate was obtained, and the plate number could reach to 6100, which were comparable to those of optimized confocal or orthogonal LIF systems for microchip based capillary electrophoresis. The reproductibility of the detection system was evaluated by Sybr Green labeled DNA markers contained five fragments. Finally, the multi-PCR products including 165
bp, 266
bp, 378
bp and 881
bp fragments could be successfully achieved for baseline separation by this system within 4
min. The work undertaken can gear toward a semi-automated handheld system with substantial time and cost saving.</description><subject>Electrophoresis</subject><subject>Laser-induced fluorescence</subject><subject>Line laser beam</subject><subject>Microfluidic chip</subject><issn>0924-4247</issn><issn>1873-3069</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2009</creationdate><recordtype>article</recordtype><recordid>eNp9kElLBDEQhYMoOI7-AG85eeu2svSGJxE3GPCi55BOKkyG3ky6hfn3ZmjPnupV8V7B-wi5ZZAzYOX9IY-DzjlAk4PMAYozsmF1JTIBZXNONtBwmUkuq0tyFeMBAISoqg2Zdn5A2umIgbaoe9omaddD5ge7mLS5bhkDRoODQWpxRjP7caDxGGfsqRsD7b0JY7J56w01ez9R7JIrjNP-lPSR6kF3xySuyYXTXcSbv7klXy_Pn09v2e7j9f3pcZcZwes5Y4CWt642jDttS8FsLZ3TzGGhteTITY28LsC1ULSMgStMYTk0dVEWZVW3Ykvu1r9TGL8XjLPqfWrQdXrAcYlKSNlIaEQystWYGsQY0Kkp-F6Ho2KgTmzVQSW26sRWgVSJbco8rBlMDX48BhWNP9GxPqTayo7-n_QvmaWE3g</recordid><startdate>20090618</startdate><enddate>20090618</enddate><creator>Xu, Baojian</creator><creator>Yang, Mo</creator><creator>Wang, Hua</creator><creator>Zhang, Honglian</creator><creator>Jin, Qinghui</creator><creator>Zhao, Jianlong</creator><creator>Wang, Huimin</creator><general>Elsevier B.V</general><scope>AAYXX</scope><scope>CITATION</scope><scope>7TB</scope><scope>7U5</scope><scope>8FD</scope><scope>FR3</scope><scope>L7M</scope></search><sort><creationdate>20090618</creationdate><title>Line laser beam based laser-induced fluorescence detection system for microfluidic chip electrophoresis analysis</title><author>Xu, Baojian ; Yang, Mo ; Wang, Hua ; Zhang, Honglian ; Jin, Qinghui ; Zhao, Jianlong ; Wang, Huimin</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c328t-10ed2bf8c12fad631d84ffa1fe5aa42e2c8e2850fb05b110f5c5d2098565678b3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2009</creationdate><topic>Electrophoresis</topic><topic>Laser-induced fluorescence</topic><topic>Line laser beam</topic><topic>Microfluidic chip</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Xu, Baojian</creatorcontrib><creatorcontrib>Yang, Mo</creatorcontrib><creatorcontrib>Wang, Hua</creatorcontrib><creatorcontrib>Zhang, Honglian</creatorcontrib><creatorcontrib>Jin, Qinghui</creatorcontrib><creatorcontrib>Zhao, Jianlong</creatorcontrib><creatorcontrib>Wang, Huimin</creatorcontrib><collection>CrossRef</collection><collection>Mechanical & Transportation Engineering Abstracts</collection><collection>Solid State and Superconductivity Abstracts</collection><collection>Technology Research Database</collection><collection>Engineering Research Database</collection><collection>Advanced Technologies Database with Aerospace</collection><jtitle>Sensors and actuators. A. Physical.</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Xu, Baojian</au><au>Yang, Mo</au><au>Wang, Hua</au><au>Zhang, Honglian</au><au>Jin, Qinghui</au><au>Zhao, Jianlong</au><au>Wang, Huimin</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Line laser beam based laser-induced fluorescence detection system for microfluidic chip electrophoresis analysis</atitle><jtitle>Sensors and actuators. A. Physical.</jtitle><date>2009-06-18</date><risdate>2009</risdate><volume>152</volume><issue>2</issue><spage>168</spage><epage>175</epage><pages>168-175</pages><issn>0924-4247</issn><eissn>1873-3069</eissn><abstract>In this work, a new laser-induced fluorescence (LIF) detection system based on a line laser beam for microfluidic chip electrophoresis analysis was developed. This detection system had the advantages of simple optical structure, compactness, and ease in constructing. Highly sensitive detection was realized by detecting the fluorescence light emitted in the micro-channel through the vertical intersection between the line laser source and micro-channel. The filtered line source was established by a bevel laser beam and a micro-gap which could facilitate the alignment of line laser beam with the microfluidic channel. Both the theoretical analysis and experimental study demonstrated that the detection system with a 0.07 mm-width micro-gap had enough sensitivity and adequate separation efficiency. By this system, a detection limit (S/N
>
12) of 1.284
×
10
−10
M fluorescein isothiocyanate was obtained, and the plate number could reach to 6100, which were comparable to those of optimized confocal or orthogonal LIF systems for microchip based capillary electrophoresis. The reproductibility of the detection system was evaluated by Sybr Green labeled DNA markers contained five fragments. Finally, the multi-PCR products including 165
bp, 266
bp, 378
bp and 881
bp fragments could be successfully achieved for baseline separation by this system within 4
min. The work undertaken can gear toward a semi-automated handheld system with substantial time and cost saving.</abstract><pub>Elsevier B.V</pub><doi>10.1016/j.sna.2009.04.005</doi><tpages>8</tpages></addata></record> |
fulltext | fulltext |
identifier | ISSN: 0924-4247 |
ispartof | Sensors and actuators. A. Physical., 2009-06, Vol.152 (2), p.168-175 |
issn | 0924-4247 1873-3069 |
language | eng |
recordid | cdi_proquest_miscellaneous_34494093 |
source | ScienceDirect Journals (5 years ago - present) |
subjects | Electrophoresis Laser-induced fluorescence Line laser beam Microfluidic chip |
title | Line laser beam based laser-induced fluorescence detection system for microfluidic chip electrophoresis analysis |
url | https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-15T10%3A00%3A07IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Line%20laser%20beam%20based%20laser-induced%20fluorescence%20detection%20system%20for%20microfluidic%20chip%20electrophoresis%20analysis&rft.jtitle=Sensors%20and%20actuators.%20A.%20Physical.&rft.au=Xu,%20Baojian&rft.date=2009-06-18&rft.volume=152&rft.issue=2&rft.spage=168&rft.epage=175&rft.pages=168-175&rft.issn=0924-4247&rft.eissn=1873-3069&rft_id=info:doi/10.1016/j.sna.2009.04.005&rft_dat=%3Cproquest_cross%3E34494093%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=34494093&rft_id=info:pmid/&rft_els_id=S0924424709001812&rfr_iscdi=true |