Picosecond time-resolved laser pump/X-ray probe experiments using a gated single-photon-counting area detector
The recent developments in X‐ray detectors have opened new possibilities in the area of time‐resolved pump/probe X‐ray experiments; this article presents the novel use of a PILATUS detector to achieve X‐ray pulse duration limited time‐resolution at the Advanced Photon Source (APS), USA. The capabili...
Gespeichert in:
Veröffentlicht in: | Journal of synchrotron radiation 2009-05, Vol.16 (3), p.387-390 |
---|---|
Hauptverfasser: | , , , , , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext bestellen |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
container_end_page | 390 |
---|---|
container_issue | 3 |
container_start_page | 387 |
container_title | Journal of synchrotron radiation |
container_volume | 16 |
creator | Ejdrup, T. Lemke, H. T. Haldrup, K. Nielsen, T. N. Arms, D. A. Walko, D. A. Miceli, A. Landahl, E. C. Dufresne, E. M. Nielsen, M. M. |
description | The recent developments in X‐ray detectors have opened new possibilities in the area of time‐resolved pump/probe X‐ray experiments; this article presents the novel use of a PILATUS detector to achieve X‐ray pulse duration limited time‐resolution at the Advanced Photon Source (APS), USA. The capability of the gated PILATUS detector to selectively detect the signal from a given X‐ray pulse in 24 bunch mode at the APS storage ring is demonstrated. A test experiment performed on polycrystalline organic thin films of α‐perylene illustrates the possibility of reaching an X‐ray pulse duration limited time‐resolution of 60 ps using the gated PILATUS detector. This is the first demonstration of X‐ray pulse duration limited data recorded using an area detector without the use of a mechanical chopper array at the beamline. |
doi_str_mv | 10.1107/S0909049509004658 |
format | Article |
fullrecord | <record><control><sourceid>proquest_24P</sourceid><recordid>TN_cdi_proquest_miscellaneous_34288251</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>34288251</sourcerecordid><originalsourceid>FETCH-LOGICAL-c4609-d3a8528f7bf1701c2828898ccc6b7fa5c7d6524e246b5301803b9e8e504764203</originalsourceid><addsrcrecordid>eNqFkE9P3DAQxS1UBHTLB-BS-dSbix3Hf3JEqLsUrVoQtIWT5TgTGpqNU9sp7LfHdFctUg-VpfFY835PnofQEaPvGaPq-IpW-ZSVyJWWUugddMAkpUQoJV696PfR6xjvKWVSFXwP7bOKV0JTfoCGi875CM4PDU7dCkiA6Ptf0ODeRgh4nFbj8Q0Jdo3H4GvA8DhCyMIhRTzFbrjDFt_ZlIHnRw9k_O6TH4jz05B-jwNY3EACl3x4g3Zb20c43N4z9GX-4fr0jCw_Lz6eniyJKyWtSMOtFoVuVd0yRZkrdKF1pZ1zslatFU41UhQlFKWsBacsr1JXoEHQUsmyoHyG3m1886d_ThCTWXXRQd_bAfwUDS-zYSFYFrKN0AUfY4DWjHk7G9aGUfMcsvkn5My83ZpP9Qqav8Q21SzQG8FD18P6_47m_Op2MRc0G8wQ2aBdTPD4B7Xhh5GKK2G-fVoYerb8ei3m5-aSPwHG4Zc0</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>34288251</pqid></control><display><type>article</type><title>Picosecond time-resolved laser pump/X-ray probe experiments using a gated single-photon-counting area detector</title><source>Wiley Online Library Open Access</source><creator>Ejdrup, T. ; Lemke, H. T. ; Haldrup, K. ; Nielsen, T. N. ; Arms, D. A. ; Walko, D. A. ; Miceli, A. ; Landahl, E. C. ; Dufresne, E. M. ; Nielsen, M. M.</creator><creatorcontrib>Ejdrup, T. ; Lemke, H. T. ; Haldrup, K. ; Nielsen, T. N. ; Arms, D. A. ; Walko, D. A. ; Miceli, A. ; Landahl, E. C. ; Dufresne, E. M. ; Nielsen, M. M.</creatorcontrib><description>The recent developments in X‐ray detectors have opened new possibilities in the area of time‐resolved pump/probe X‐ray experiments; this article presents the novel use of a PILATUS detector to achieve X‐ray pulse duration limited time‐resolution at the Advanced Photon Source (APS), USA. The capability of the gated PILATUS detector to selectively detect the signal from a given X‐ray pulse in 24 bunch mode at the APS storage ring is demonstrated. A test experiment performed on polycrystalline organic thin films of α‐perylene illustrates the possibility of reaching an X‐ray pulse duration limited time‐resolution of 60 ps using the gated PILATUS detector. This is the first demonstration of X‐ray pulse duration limited data recorded using an area detector without the use of a mechanical chopper array at the beamline.</description><identifier>ISSN: 1600-5775</identifier><identifier>ISSN: 0909-0495</identifier><identifier>EISSN: 1600-5775</identifier><identifier>DOI: 10.1107/S0909049509004658</identifier><identifier>PMID: 19395803</identifier><language>eng</language><publisher>5 Abbey Square, Chester, Cheshire CH1 2HU, England: International Union of Crystallography</publisher><subject>Computer-Aided Design ; Equipment Design ; Equipment Failure Analysis ; Lasers, Solid-State ; Photometry - instrumentation ; PILATUS ; pixel detector ; Radiation Dosage ; Radiometry - instrumentation ; Reproducibility of Results ; Sensitivity and Specificity ; time-resolved X-ray diffraction ; Transducers ; X-Ray Diffraction - instrumentation ; α-perylene</subject><ispartof>Journal of synchrotron radiation, 2009-05, Vol.16 (3), p.387-390</ispartof><rights>International Union of Crystallography, 2009</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c4609-d3a8528f7bf1701c2828898ccc6b7fa5c7d6524e246b5301803b9e8e504764203</citedby></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktopdf>$$Uhttps://onlinelibrary.wiley.com/doi/pdf/10.1107%2FS0909049509004658$$EPDF$$P50$$Gwiley$$H</linktopdf><linktohtml>$$Uhttps://onlinelibrary.wiley.com/doi/full/10.1107%2FS0909049509004658$$EHTML$$P50$$Gwiley$$H</linktohtml><link.rule.ids>314,776,780,1411,11541,27901,27902,45550,45551,46027,46451</link.rule.ids><linktorsrc>$$Uhttps://onlinelibrary.wiley.com/doi/abs/10.1107%2FS0909049509004658$$EView_record_in_Wiley-Blackwell$$FView_record_in_$$GWiley-Blackwell</linktorsrc><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/19395803$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Ejdrup, T.</creatorcontrib><creatorcontrib>Lemke, H. T.</creatorcontrib><creatorcontrib>Haldrup, K.</creatorcontrib><creatorcontrib>Nielsen, T. N.</creatorcontrib><creatorcontrib>Arms, D. A.</creatorcontrib><creatorcontrib>Walko, D. A.</creatorcontrib><creatorcontrib>Miceli, A.</creatorcontrib><creatorcontrib>Landahl, E. C.</creatorcontrib><creatorcontrib>Dufresne, E. M.</creatorcontrib><creatorcontrib>Nielsen, M. M.</creatorcontrib><title>Picosecond time-resolved laser pump/X-ray probe experiments using a gated single-photon-counting area detector</title><title>Journal of synchrotron radiation</title><addtitle>J. Synchrotron Rad</addtitle><description>The recent developments in X‐ray detectors have opened new possibilities in the area of time‐resolved pump/probe X‐ray experiments; this article presents the novel use of a PILATUS detector to achieve X‐ray pulse duration limited time‐resolution at the Advanced Photon Source (APS), USA. The capability of the gated PILATUS detector to selectively detect the signal from a given X‐ray pulse in 24 bunch mode at the APS storage ring is demonstrated. A test experiment performed on polycrystalline organic thin films of α‐perylene illustrates the possibility of reaching an X‐ray pulse duration limited time‐resolution of 60 ps using the gated PILATUS detector. This is the first demonstration of X‐ray pulse duration limited data recorded using an area detector without the use of a mechanical chopper array at the beamline.</description><subject>Computer-Aided Design</subject><subject>Equipment Design</subject><subject>Equipment Failure Analysis</subject><subject>Lasers, Solid-State</subject><subject>Photometry - instrumentation</subject><subject>PILATUS</subject><subject>pixel detector</subject><subject>Radiation Dosage</subject><subject>Radiometry - instrumentation</subject><subject>Reproducibility of Results</subject><subject>Sensitivity and Specificity</subject><subject>time-resolved X-ray diffraction</subject><subject>Transducers</subject><subject>X-Ray Diffraction - instrumentation</subject><subject>α-perylene</subject><issn>1600-5775</issn><issn>0909-0495</issn><issn>1600-5775</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2009</creationdate><recordtype>article</recordtype><sourceid>EIF</sourceid><recordid>eNqFkE9P3DAQxS1UBHTLB-BS-dSbix3Hf3JEqLsUrVoQtIWT5TgTGpqNU9sp7LfHdFctUg-VpfFY835PnofQEaPvGaPq-IpW-ZSVyJWWUugddMAkpUQoJV696PfR6xjvKWVSFXwP7bOKV0JTfoCGi875CM4PDU7dCkiA6Ptf0ODeRgh4nFbj8Q0Jdo3H4GvA8DhCyMIhRTzFbrjDFt_ZlIHnRw9k_O6TH4jz05B-jwNY3EACl3x4g3Zb20c43N4z9GX-4fr0jCw_Lz6eniyJKyWtSMOtFoVuVd0yRZkrdKF1pZ1zslatFU41UhQlFKWsBacsr1JXoEHQUsmyoHyG3m1886d_ThCTWXXRQd_bAfwUDS-zYSFYFrKN0AUfY4DWjHk7G9aGUfMcsvkn5My83ZpP9Qqav8Q21SzQG8FD18P6_47m_Op2MRc0G8wQ2aBdTPD4B7Xhh5GKK2G-fVoYerb8ei3m5-aSPwHG4Zc0</recordid><startdate>200905</startdate><enddate>200905</enddate><creator>Ejdrup, T.</creator><creator>Lemke, H. T.</creator><creator>Haldrup, K.</creator><creator>Nielsen, T. N.</creator><creator>Arms, D. A.</creator><creator>Walko, D. A.</creator><creator>Miceli, A.</creator><creator>Landahl, E. C.</creator><creator>Dufresne, E. M.</creator><creator>Nielsen, M. M.</creator><general>International Union of Crystallography</general><scope>BSCLL</scope><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7U5</scope><scope>8FD</scope><scope>L7M</scope></search><sort><creationdate>200905</creationdate><title>Picosecond time-resolved laser pump/X-ray probe experiments using a gated single-photon-counting area detector</title><author>Ejdrup, T. ; Lemke, H. T. ; Haldrup, K. ; Nielsen, T. N. ; Arms, D. A. ; Walko, D. A. ; Miceli, A. ; Landahl, E. C. ; Dufresne, E. M. ; Nielsen, M. M.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c4609-d3a8528f7bf1701c2828898ccc6b7fa5c7d6524e246b5301803b9e8e504764203</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2009</creationdate><topic>Computer-Aided Design</topic><topic>Equipment Design</topic><topic>Equipment Failure Analysis</topic><topic>Lasers, Solid-State</topic><topic>Photometry - instrumentation</topic><topic>PILATUS</topic><topic>pixel detector</topic><topic>Radiation Dosage</topic><topic>Radiometry - instrumentation</topic><topic>Reproducibility of Results</topic><topic>Sensitivity and Specificity</topic><topic>time-resolved X-ray diffraction</topic><topic>Transducers</topic><topic>X-Ray Diffraction - instrumentation</topic><topic>α-perylene</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Ejdrup, T.</creatorcontrib><creatorcontrib>Lemke, H. T.</creatorcontrib><creatorcontrib>Haldrup, K.</creatorcontrib><creatorcontrib>Nielsen, T. N.</creatorcontrib><creatorcontrib>Arms, D. A.</creatorcontrib><creatorcontrib>Walko, D. A.</creatorcontrib><creatorcontrib>Miceli, A.</creatorcontrib><creatorcontrib>Landahl, E. C.</creatorcontrib><creatorcontrib>Dufresne, E. M.</creatorcontrib><creatorcontrib>Nielsen, M. M.</creatorcontrib><collection>Istex</collection><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>Solid State and Superconductivity Abstracts</collection><collection>Technology Research Database</collection><collection>Advanced Technologies Database with Aerospace</collection><jtitle>Journal of synchrotron radiation</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext_linktorsrc</fulltext></delivery><addata><au>Ejdrup, T.</au><au>Lemke, H. T.</au><au>Haldrup, K.</au><au>Nielsen, T. N.</au><au>Arms, D. A.</au><au>Walko, D. A.</au><au>Miceli, A.</au><au>Landahl, E. C.</au><au>Dufresne, E. M.</au><au>Nielsen, M. M.</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Picosecond time-resolved laser pump/X-ray probe experiments using a gated single-photon-counting area detector</atitle><jtitle>Journal of synchrotron radiation</jtitle><addtitle>J. Synchrotron Rad</addtitle><date>2009-05</date><risdate>2009</risdate><volume>16</volume><issue>3</issue><spage>387</spage><epage>390</epage><pages>387-390</pages><issn>1600-5775</issn><issn>0909-0495</issn><eissn>1600-5775</eissn><abstract>The recent developments in X‐ray detectors have opened new possibilities in the area of time‐resolved pump/probe X‐ray experiments; this article presents the novel use of a PILATUS detector to achieve X‐ray pulse duration limited time‐resolution at the Advanced Photon Source (APS), USA. The capability of the gated PILATUS detector to selectively detect the signal from a given X‐ray pulse in 24 bunch mode at the APS storage ring is demonstrated. A test experiment performed on polycrystalline organic thin films of α‐perylene illustrates the possibility of reaching an X‐ray pulse duration limited time‐resolution of 60 ps using the gated PILATUS detector. This is the first demonstration of X‐ray pulse duration limited data recorded using an area detector without the use of a mechanical chopper array at the beamline.</abstract><cop>5 Abbey Square, Chester, Cheshire CH1 2HU, England</cop><pub>International Union of Crystallography</pub><pmid>19395803</pmid><doi>10.1107/S0909049509004658</doi><tpages>4</tpages><oa>free_for_read</oa></addata></record> |
fulltext | fulltext_linktorsrc |
identifier | ISSN: 1600-5775 |
ispartof | Journal of synchrotron radiation, 2009-05, Vol.16 (3), p.387-390 |
issn | 1600-5775 0909-0495 1600-5775 |
language | eng |
recordid | cdi_proquest_miscellaneous_34288251 |
source | Wiley Online Library Open Access |
subjects | Computer-Aided Design Equipment Design Equipment Failure Analysis Lasers, Solid-State Photometry - instrumentation PILATUS pixel detector Radiation Dosage Radiometry - instrumentation Reproducibility of Results Sensitivity and Specificity time-resolved X-ray diffraction Transducers X-Ray Diffraction - instrumentation α-perylene |
title | Picosecond time-resolved laser pump/X-ray probe experiments using a gated single-photon-counting area detector |
url | https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-02-20T20%3A38%3A04IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_24P&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Picosecond%20time-resolved%20laser%20pump/X-ray%20probe%20experiments%20using%20a%20gated%20single-photon-counting%20area%20detector&rft.jtitle=Journal%20of%20synchrotron%20radiation&rft.au=Ejdrup,%20T.&rft.date=2009-05&rft.volume=16&rft.issue=3&rft.spage=387&rft.epage=390&rft.pages=387-390&rft.issn=1600-5775&rft.eissn=1600-5775&rft_id=info:doi/10.1107/S0909049509004658&rft_dat=%3Cproquest_24P%3E34288251%3C/proquest_24P%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=34288251&rft_id=info:pmid/19395803&rfr_iscdi=true |