Measurement of the magnetic moment in a cold worked 304 stainless steel using HTS SQUID

The magnetic properties of stainless steel have been investigated using a radio frequency (RF) high-temperature superconductivity (HTS) SQUID (Superconducting QUantum Interference Device)-based susceptometer. The nuclear grade 304 stainless steel is nonmagnetic at a normal condition but it changes t...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Journal of magnetism and magnetic materials 2008-10, Vol.320 (20), p.e571-e574
Hauptverfasser: Park, D.G., Kim, D.W., Angani, C.S., Timofeev, V.P., Cheong, Y.M.
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:The magnetic properties of stainless steel have been investigated using a radio frequency (RF) high-temperature superconductivity (HTS) SQUID (Superconducting QUantum Interference Device)-based susceptometer. The nuclear grade 304 stainless steel is nonmagnetic at a normal condition but it changes to a partially ferromagnetic state associated with martensitic transformation under a plastic deformation. The magnetic moment of the 304 stainless steels was increased with an increasing cold work rate, and decreased with an increasing annealing temperature. The change of mechanical properties such as yield strength and ultimate tensile strength (UTS) are also analyzed in terms of deformation-induced martensitic transformation.
ISSN:0304-8853