A comparative structural investigation of GaN implanted with rare earth ions at room temperature and 500 deg C

The crystallographic damage induced in GaN by 300keV rare earth ions implantation has been investigated as a function of the implantation temperature. The defect structure of GaN thin films implanted at 500 deg C with Eu or Er ions with fluences ranging between 1X1015 and 2X1016at./cm2 has been comp...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Materials science & engineering. B, Solid-state materials for advanced technology Solid-state materials for advanced technology, 2008-01, Vol.146 (1-3), p.204-207
Hauptverfasser: Gloux, F, Ruterana, P, Lorenz, K, Alves, E
Format: Artikel
Sprache:eng
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 207
container_issue 1-3
container_start_page 204
container_title Materials science & engineering. B, Solid-state materials for advanced technology
container_volume 146
creator Gloux, F
Ruterana, P
Lorenz, K
Alves, E
description The crystallographic damage induced in GaN by 300keV rare earth ions implantation has been investigated as a function of the implantation temperature. The defect structure of GaN thin films implanted at 500 deg C with Eu or Er ions with fluences ranging between 1X1015 and 2X1016at./cm2 has been compared with the case of implantation performed at room temperature (RT). Transmission electron microscopy (TEM) investigation shows that less damage is formed during implantation at the higher temperature: basal stacking faults with a majority of I1 type and prismatic stacking faults have been observed as in GaN implanted at RT, but with a lower density. The nanocrystalline layer observed when GaN was implanted at RT with rare earth ion fluences higher than 3X1015at./cm2, did not form for fluences up to 2X1016at./cm2. Implantation of GaN at 500 deg C through an ultrathin AlN cap points out the protective role of this cap against the GaN surface erosion that occurs from 8X1015at./cm2. This method appears as a promising way to reduce the induced damage during the GaN implantation process.
doi_str_mv 10.1016/j.mseb.2007.07.019
format Article
fullrecord <record><control><sourceid>proquest</sourceid><recordid>TN_cdi_proquest_miscellaneous_31722841</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>31722841</sourcerecordid><originalsourceid>FETCH-proquest_miscellaneous_317228413</originalsourceid><addsrcrecordid>eNqNjb1OAzEQhF0EiUB4Aaqt6HLsOoRLShTxU1HRR5u7TXB0tg-vnbx-jMQDII00I32jGWPuCRtCen48Nl5l11jEtvkVrSdmimtL8yVhe21uVI-ISNbaqQkv0EU_cuLsTgKaU-lySTyACyfR7A4VxABxD-_8Cc6PA4csPZxd_obESUA41VhLCpwhxeghix-lTpaKOfSwRIReDrCZmas9Dyp3f35rHt5evzYf8zHFn1L_tt5pJ0M9kVh0u6DW2tUTLf5dvAB8SlIY</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>31722841</pqid></control><display><type>article</type><title>A comparative structural investigation of GaN implanted with rare earth ions at room temperature and 500 deg C</title><source>Elsevier ScienceDirect Journals</source><creator>Gloux, F ; Ruterana, P ; Lorenz, K ; Alves, E</creator><creatorcontrib>Gloux, F ; Ruterana, P ; Lorenz, K ; Alves, E</creatorcontrib><description>The crystallographic damage induced in GaN by 300keV rare earth ions implantation has been investigated as a function of the implantation temperature. The defect structure of GaN thin films implanted at 500 deg C with Eu or Er ions with fluences ranging between 1X1015 and 2X1016at./cm2 has been compared with the case of implantation performed at room temperature (RT). Transmission electron microscopy (TEM) investigation shows that less damage is formed during implantation at the higher temperature: basal stacking faults with a majority of I1 type and prismatic stacking faults have been observed as in GaN implanted at RT, but with a lower density. The nanocrystalline layer observed when GaN was implanted at RT with rare earth ion fluences higher than 3X1015at./cm2, did not form for fluences up to 2X1016at./cm2. Implantation of GaN at 500 deg C through an ultrathin AlN cap points out the protective role of this cap against the GaN surface erosion that occurs from 8X1015at./cm2. This method appears as a promising way to reduce the induced damage during the GaN implantation process.</description><identifier>ISSN: 0921-5107</identifier><identifier>DOI: 10.1016/j.mseb.2007.07.019</identifier><language>eng</language><ispartof>Materials science &amp; engineering. B, Solid-state materials for advanced technology, 2008-01, Vol.146 (1-3), p.204-207</ispartof><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,777,781,27905,27906</link.rule.ids></links><search><creatorcontrib>Gloux, F</creatorcontrib><creatorcontrib>Ruterana, P</creatorcontrib><creatorcontrib>Lorenz, K</creatorcontrib><creatorcontrib>Alves, E</creatorcontrib><title>A comparative structural investigation of GaN implanted with rare earth ions at room temperature and 500 deg C</title><title>Materials science &amp; engineering. B, Solid-state materials for advanced technology</title><description>The crystallographic damage induced in GaN by 300keV rare earth ions implantation has been investigated as a function of the implantation temperature. The defect structure of GaN thin films implanted at 500 deg C with Eu or Er ions with fluences ranging between 1X1015 and 2X1016at./cm2 has been compared with the case of implantation performed at room temperature (RT). Transmission electron microscopy (TEM) investigation shows that less damage is formed during implantation at the higher temperature: basal stacking faults with a majority of I1 type and prismatic stacking faults have been observed as in GaN implanted at RT, but with a lower density. The nanocrystalline layer observed when GaN was implanted at RT with rare earth ion fluences higher than 3X1015at./cm2, did not form for fluences up to 2X1016at./cm2. Implantation of GaN at 500 deg C through an ultrathin AlN cap points out the protective role of this cap against the GaN surface erosion that occurs from 8X1015at./cm2. This method appears as a promising way to reduce the induced damage during the GaN implantation process.</description><issn>0921-5107</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2008</creationdate><recordtype>article</recordtype><recordid>eNqNjb1OAzEQhF0EiUB4Aaqt6HLsOoRLShTxU1HRR5u7TXB0tg-vnbx-jMQDII00I32jGWPuCRtCen48Nl5l11jEtvkVrSdmimtL8yVhe21uVI-ISNbaqQkv0EU_cuLsTgKaU-lySTyACyfR7A4VxABxD-_8Cc6PA4csPZxd_obESUA41VhLCpwhxeghix-lTpaKOfSwRIReDrCZmas9Dyp3f35rHt5evzYf8zHFn1L_tt5pJ0M9kVh0u6DW2tUTLf5dvAB8SlIY</recordid><startdate>20080115</startdate><enddate>20080115</enddate><creator>Gloux, F</creator><creator>Ruterana, P</creator><creator>Lorenz, K</creator><creator>Alves, E</creator><scope>7QF</scope><scope>7SR</scope><scope>8BQ</scope><scope>8FD</scope><scope>JG9</scope></search><sort><creationdate>20080115</creationdate><title>A comparative structural investigation of GaN implanted with rare earth ions at room temperature and 500 deg C</title><author>Gloux, F ; Ruterana, P ; Lorenz, K ; Alves, E</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-proquest_miscellaneous_317228413</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2008</creationdate><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Gloux, F</creatorcontrib><creatorcontrib>Ruterana, P</creatorcontrib><creatorcontrib>Lorenz, K</creatorcontrib><creatorcontrib>Alves, E</creatorcontrib><collection>Aluminium Industry Abstracts</collection><collection>Engineered Materials Abstracts</collection><collection>METADEX</collection><collection>Technology Research Database</collection><collection>Materials Research Database</collection><jtitle>Materials science &amp; engineering. B, Solid-state materials for advanced technology</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Gloux, F</au><au>Ruterana, P</au><au>Lorenz, K</au><au>Alves, E</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>A comparative structural investigation of GaN implanted with rare earth ions at room temperature and 500 deg C</atitle><jtitle>Materials science &amp; engineering. B, Solid-state materials for advanced technology</jtitle><date>2008-01-15</date><risdate>2008</risdate><volume>146</volume><issue>1-3</issue><spage>204</spage><epage>207</epage><pages>204-207</pages><issn>0921-5107</issn><abstract>The crystallographic damage induced in GaN by 300keV rare earth ions implantation has been investigated as a function of the implantation temperature. The defect structure of GaN thin films implanted at 500 deg C with Eu or Er ions with fluences ranging between 1X1015 and 2X1016at./cm2 has been compared with the case of implantation performed at room temperature (RT). Transmission electron microscopy (TEM) investigation shows that less damage is formed during implantation at the higher temperature: basal stacking faults with a majority of I1 type and prismatic stacking faults have been observed as in GaN implanted at RT, but with a lower density. The nanocrystalline layer observed when GaN was implanted at RT with rare earth ion fluences higher than 3X1015at./cm2, did not form for fluences up to 2X1016at./cm2. Implantation of GaN at 500 deg C through an ultrathin AlN cap points out the protective role of this cap against the GaN surface erosion that occurs from 8X1015at./cm2. This method appears as a promising way to reduce the induced damage during the GaN implantation process.</abstract><doi>10.1016/j.mseb.2007.07.019</doi></addata></record>
fulltext fulltext
identifier ISSN: 0921-5107
ispartof Materials science & engineering. B, Solid-state materials for advanced technology, 2008-01, Vol.146 (1-3), p.204-207
issn 0921-5107
language eng
recordid cdi_proquest_miscellaneous_31722841
source Elsevier ScienceDirect Journals
title A comparative structural investigation of GaN implanted with rare earth ions at room temperature and 500 deg C
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-20T16%3A54%3A16IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=A%20comparative%20structural%20investigation%20of%20GaN%20implanted%20with%20rare%20earth%20ions%20at%20room%20temperature%20and%20500%20deg%20C&rft.jtitle=Materials%20science%20&%20engineering.%20B,%20Solid-state%20materials%20for%20advanced%20technology&rft.au=Gloux,%20F&rft.date=2008-01-15&rft.volume=146&rft.issue=1-3&rft.spage=204&rft.epage=207&rft.pages=204-207&rft.issn=0921-5107&rft_id=info:doi/10.1016/j.mseb.2007.07.019&rft_dat=%3Cproquest%3E31722841%3C/proquest%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=31722841&rft_id=info:pmid/&rfr_iscdi=true