Progranulin measurement with a new automated method: a step forward in the diagnostic approach to neurodegenerative disorders

Mutations in the gene encoded glycoprotein progranulin (PGRN), cause 5-10 % of all cases of frontotemporal lobar degeneration (FTLD). The aim of our study was to verify the analytical and clinical performance of an automated chemiluminescent immunoassay method for PGRN measurement recently developed...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Clinical chemistry and laboratory medicine 2025-01
Hauptverfasser: Cosma, Chiara, Talli, Ilaria, Pangrazzi, Elisa, Padoan, Andrea, Cerutti, Helena, Zaninotto, Martina, Gabelli, Carlo, Plebani, Mario
Format: Artikel
Sprache:eng
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Mutations in the gene encoded glycoprotein progranulin (PGRN), cause 5-10 % of all cases of frontotemporal lobar degeneration (FTLD). The aim of our study was to verify the analytical and clinical performance of an automated chemiluminescent immunoassay method for PGRN measurement recently developed (Chorus Evo, Diesse Diagnostica, Italy). Five plasma pools and residual plasma samples (K EDTA) from 25 control subjects (11 males, 62-79 years; 14 females, 54-76 years) and 151 patients (70 males, 53-81 years; 81 females, 44-82 years) with different neurodegenerative disorders (NDs), were assayed. In 61 out of 151 patients, genetic screening was carried. Within-run imprecision (CV%) ranged from 3.8 % (11.5 pg/L) to 10.8 % (2.5 pg/L), and between-run, from 5.6 % (68.7 pg/L) to 10.7 % (2.8 pg/L). At genetic screening, 3 out of 61 patients were classified as + carriers, 18 as "other mutations" and 40 as "no-mutations" carriers. The PGRN median level in + carriers (15.9 pg/L) was significantly lower than that in control subjects (32.8 pg/L; p=0.006), in - (27.50 pg/L; p=0.007), in other mutation carriers (24.80 pg/L; p=0.05) and in NDs patients (22.40 pg/L; p=0.05) ROC analysis, demonstrates the accuracy of progranulin levels in discriminating between " +" and " -" carriers (AUC 0.985) as well as " +" and "other mutations" carriers (AUC 0.870). The new automated progranulin method, for robust analytical performance, is suitable for use in the clinical setting, supporting clinicians in making a differential diagnosis in patients with neurodegenerative disorder.
ISSN:1434-6621
1437-4331
1437-4331
DOI:10.1515/cclm-2024-1143