Development and validation of a targeted mass spectrometry method for the quantification of milk protein allergens in multiple complex food matrices using matrix-independent calibration

Quantitative detection of food allergens is crucial in assessing the risk of allergic responses in susceptible individuals and ensuring regulatory compliance. Targeted mass spectrometry methods provide an opportunity to analyze allergens from complex, processed food matrices. However, probable inter...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Food control 2024-08, Vol.162, p.110444, Article 110444
Hauptverfasser: Ramachandran, Bini, Downs, Melanie L.
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page
container_issue
container_start_page 110444
container_title Food control
container_volume 162
creator Ramachandran, Bini
Downs, Melanie L.
description Quantitative detection of food allergens is crucial in assessing the risk of allergic responses in susceptible individuals and ensuring regulatory compliance. Targeted mass spectrometry methods provide an opportunity to analyze allergens from complex, processed food matrices. However, probable interferences of diverse food matrices mandates preparation of matrix-matched calibration curves, challenging adaptation of methods into multiple matrices. In this study, we have developed a novel matrix-independent calibration strategy employing exogenous carrier proteins as background and demonstrated its adaptability in quantification of milk from multiple food matrices at concentrations relevant for risk assessment applications. Peptides representing casein or whey fractions of milk were detectable from concentrations as low as 1 ppm nonfat dry milk (NFDM) in baked cookie matrix at 46–99% accuracy, 0.5 ppm total milk protein (TMP) in pasteurized beverages at 94–138% accuracy, and 1 ppm casein in chocolate at 35–51% accuracy. Quantitative estimations of milk from matrix-independent calibration curves in the background of egg white powder as exogenous carrier were comparable to those from a matrix-matched calibration curve, and the quantitative precision was within 30% CV across the inter-day replicates. The sensitivity, accuracy, and precision of this matrix-independent approach ensure robustness of the method for high throughput food allergen analysis as required in routine testing labs. [Display omitted] •LC-MS/MS detected milk protein in matrices at levels relevant for risk assessment.•Matrix-independent calibration was developed for total milk protein quantification.•The method had good quantitative recovery of milk protein from processed matrices.•Longitudinal data demonstrated good within-lab method stability and performance.
doi_str_mv 10.1016/j.foodcont.2024.110444
format Article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_3153793069</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><els_id>S0956713524001610</els_id><sourcerecordid>3153793069</sourcerecordid><originalsourceid>FETCH-LOGICAL-c292t-eff00cbdea5c5e4be48f426fc73a3295ea33e5dea12cbd44caa0d84a1f4d62143</originalsourceid><addsrcrecordid>eNqFUU1P3DAQtaoidQv9C5WPXLL4K8nmBqKFIiH1Us6W1x6Dt44dbGfF_rT-O7xN4drLjEfz5s08P4S-UrKmhHYXu7WN0egYypoRJtaUEiHEB7Sim543PWXDR7QiQ9vVN28_oc857wihPaFkhf58gz34OI0QClbB4L3yzqjiYsDRYoWLSo9QwOBR5YzzBLqkOEJJB1zjUzTYxoTLE-DnWYXirNPv06Pzv_GUYgEXsPIeKlXIuBbj7IubPGAdx5pe8FFCXVGS05DxnF14XMqXxgUDE9RQL9T1um36u-AMnVjlM3z5l0_Rw833X9c_mvuft3fXV_eNZgMrDVhLiN4aUK1uQWxBbKxgndU9V5wNLSjOoa1tyipKCK0UMRuhqBWmY1TwU3S-8FYhzzPkIkeXNXivAsQ5S05b3g-cdEOFdgtUp5hzAiun5EaVDpISefRK7uSbV_LolVy8qoOXyyBUIXsHSWbtIGgwLtUPlya6_1G8As-CqFs</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>3153793069</pqid></control><display><type>article</type><title>Development and validation of a targeted mass spectrometry method for the quantification of milk protein allergens in multiple complex food matrices using matrix-independent calibration</title><source>Elsevier ScienceDirect Journals</source><creator>Ramachandran, Bini ; Downs, Melanie L.</creator><creatorcontrib>Ramachandran, Bini ; Downs, Melanie L.</creatorcontrib><description>Quantitative detection of food allergens is crucial in assessing the risk of allergic responses in susceptible individuals and ensuring regulatory compliance. Targeted mass spectrometry methods provide an opportunity to analyze allergens from complex, processed food matrices. However, probable interferences of diverse food matrices mandates preparation of matrix-matched calibration curves, challenging adaptation of methods into multiple matrices. In this study, we have developed a novel matrix-independent calibration strategy employing exogenous carrier proteins as background and demonstrated its adaptability in quantification of milk from multiple food matrices at concentrations relevant for risk assessment applications. Peptides representing casein or whey fractions of milk were detectable from concentrations as low as 1 ppm nonfat dry milk (NFDM) in baked cookie matrix at 46–99% accuracy, 0.5 ppm total milk protein (TMP) in pasteurized beverages at 94–138% accuracy, and 1 ppm casein in chocolate at 35–51% accuracy. Quantitative estimations of milk from matrix-independent calibration curves in the background of egg white powder as exogenous carrier were comparable to those from a matrix-matched calibration curve, and the quantitative precision was within 30% CV across the inter-day replicates. The sensitivity, accuracy, and precision of this matrix-independent approach ensure robustness of the method for high throughput food allergen analysis as required in routine testing labs. [Display omitted] •LC-MS/MS detected milk protein in matrices at levels relevant for risk assessment.•Matrix-independent calibration was developed for total milk protein quantification.•The method had good quantitative recovery of milk protein from processed matrices.•Longitudinal data demonstrated good within-lab method stability and performance.</description><identifier>ISSN: 0956-7135</identifier><identifier>EISSN: 1873-7129</identifier><identifier>DOI: 10.1016/j.foodcont.2024.110444</identifier><language>eng</language><publisher>Elsevier Ltd</publisher><subject>calibration ; casein ; chocolate ; compliance ; cookies ; dried skim milk ; egg albumen ; Food allergen ; food allergens ; food safety ; mass spectrometry ; Matrix-independent calibration ; milk ; Milk protein quantification ; pasteurization ; peptides ; risk ; Risk assessment ; Tandem mass spectrometry ; Targeted proteomics ; whey</subject><ispartof>Food control, 2024-08, Vol.162, p.110444, Article 110444</ispartof><rights>2024 Elsevier Ltd</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><cites>FETCH-LOGICAL-c292t-eff00cbdea5c5e4be48f426fc73a3295ea33e5dea12cbd44caa0d84a1f4d62143</cites><orcidid>0000-0001-8346-6540</orcidid></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://www.sciencedirect.com/science/article/pii/S0956713524001610$$EHTML$$P50$$Gelsevier$$H</linktohtml><link.rule.ids>314,776,780,3537,27901,27902,65534</link.rule.ids></links><search><creatorcontrib>Ramachandran, Bini</creatorcontrib><creatorcontrib>Downs, Melanie L.</creatorcontrib><title>Development and validation of a targeted mass spectrometry method for the quantification of milk protein allergens in multiple complex food matrices using matrix-independent calibration</title><title>Food control</title><description>Quantitative detection of food allergens is crucial in assessing the risk of allergic responses in susceptible individuals and ensuring regulatory compliance. Targeted mass spectrometry methods provide an opportunity to analyze allergens from complex, processed food matrices. However, probable interferences of diverse food matrices mandates preparation of matrix-matched calibration curves, challenging adaptation of methods into multiple matrices. In this study, we have developed a novel matrix-independent calibration strategy employing exogenous carrier proteins as background and demonstrated its adaptability in quantification of milk from multiple food matrices at concentrations relevant for risk assessment applications. Peptides representing casein or whey fractions of milk were detectable from concentrations as low as 1 ppm nonfat dry milk (NFDM) in baked cookie matrix at 46–99% accuracy, 0.5 ppm total milk protein (TMP) in pasteurized beverages at 94–138% accuracy, and 1 ppm casein in chocolate at 35–51% accuracy. Quantitative estimations of milk from matrix-independent calibration curves in the background of egg white powder as exogenous carrier were comparable to those from a matrix-matched calibration curve, and the quantitative precision was within 30% CV across the inter-day replicates. The sensitivity, accuracy, and precision of this matrix-independent approach ensure robustness of the method for high throughput food allergen analysis as required in routine testing labs. [Display omitted] •LC-MS/MS detected milk protein in matrices at levels relevant for risk assessment.•Matrix-independent calibration was developed for total milk protein quantification.•The method had good quantitative recovery of milk protein from processed matrices.•Longitudinal data demonstrated good within-lab method stability and performance.</description><subject>calibration</subject><subject>casein</subject><subject>chocolate</subject><subject>compliance</subject><subject>cookies</subject><subject>dried skim milk</subject><subject>egg albumen</subject><subject>Food allergen</subject><subject>food allergens</subject><subject>food safety</subject><subject>mass spectrometry</subject><subject>Matrix-independent calibration</subject><subject>milk</subject><subject>Milk protein quantification</subject><subject>pasteurization</subject><subject>peptides</subject><subject>risk</subject><subject>Risk assessment</subject><subject>Tandem mass spectrometry</subject><subject>Targeted proteomics</subject><subject>whey</subject><issn>0956-7135</issn><issn>1873-7129</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2024</creationdate><recordtype>article</recordtype><recordid>eNqFUU1P3DAQtaoidQv9C5WPXLL4K8nmBqKFIiH1Us6W1x6Dt44dbGfF_rT-O7xN4drLjEfz5s08P4S-UrKmhHYXu7WN0egYypoRJtaUEiHEB7Sim543PWXDR7QiQ9vVN28_oc857wihPaFkhf58gz34OI0QClbB4L3yzqjiYsDRYoWLSo9QwOBR5YzzBLqkOEJJB1zjUzTYxoTLE-DnWYXirNPv06Pzv_GUYgEXsPIeKlXIuBbj7IubPGAdx5pe8FFCXVGS05DxnF14XMqXxgUDE9RQL9T1um36u-AMnVjlM3z5l0_Rw833X9c_mvuft3fXV_eNZgMrDVhLiN4aUK1uQWxBbKxgndU9V5wNLSjOoa1tyipKCK0UMRuhqBWmY1TwU3S-8FYhzzPkIkeXNXivAsQ5S05b3g-cdEOFdgtUp5hzAiun5EaVDpISefRK7uSbV_LolVy8qoOXyyBUIXsHSWbtIGgwLtUPlya6_1G8As-CqFs</recordid><startdate>202408</startdate><enddate>202408</enddate><creator>Ramachandran, Bini</creator><creator>Downs, Melanie L.</creator><general>Elsevier Ltd</general><scope>AAYXX</scope><scope>CITATION</scope><scope>7S9</scope><scope>L.6</scope><orcidid>https://orcid.org/0000-0001-8346-6540</orcidid></search><sort><creationdate>202408</creationdate><title>Development and validation of a targeted mass spectrometry method for the quantification of milk protein allergens in multiple complex food matrices using matrix-independent calibration</title><author>Ramachandran, Bini ; Downs, Melanie L.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c292t-eff00cbdea5c5e4be48f426fc73a3295ea33e5dea12cbd44caa0d84a1f4d62143</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2024</creationdate><topic>calibration</topic><topic>casein</topic><topic>chocolate</topic><topic>compliance</topic><topic>cookies</topic><topic>dried skim milk</topic><topic>egg albumen</topic><topic>Food allergen</topic><topic>food allergens</topic><topic>food safety</topic><topic>mass spectrometry</topic><topic>Matrix-independent calibration</topic><topic>milk</topic><topic>Milk protein quantification</topic><topic>pasteurization</topic><topic>peptides</topic><topic>risk</topic><topic>Risk assessment</topic><topic>Tandem mass spectrometry</topic><topic>Targeted proteomics</topic><topic>whey</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Ramachandran, Bini</creatorcontrib><creatorcontrib>Downs, Melanie L.</creatorcontrib><collection>CrossRef</collection><collection>AGRICOLA</collection><collection>AGRICOLA - Academic</collection><jtitle>Food control</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Ramachandran, Bini</au><au>Downs, Melanie L.</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Development and validation of a targeted mass spectrometry method for the quantification of milk protein allergens in multiple complex food matrices using matrix-independent calibration</atitle><jtitle>Food control</jtitle><date>2024-08</date><risdate>2024</risdate><volume>162</volume><spage>110444</spage><pages>110444-</pages><artnum>110444</artnum><issn>0956-7135</issn><eissn>1873-7129</eissn><abstract>Quantitative detection of food allergens is crucial in assessing the risk of allergic responses in susceptible individuals and ensuring regulatory compliance. Targeted mass spectrometry methods provide an opportunity to analyze allergens from complex, processed food matrices. However, probable interferences of diverse food matrices mandates preparation of matrix-matched calibration curves, challenging adaptation of methods into multiple matrices. In this study, we have developed a novel matrix-independent calibration strategy employing exogenous carrier proteins as background and demonstrated its adaptability in quantification of milk from multiple food matrices at concentrations relevant for risk assessment applications. Peptides representing casein or whey fractions of milk were detectable from concentrations as low as 1 ppm nonfat dry milk (NFDM) in baked cookie matrix at 46–99% accuracy, 0.5 ppm total milk protein (TMP) in pasteurized beverages at 94–138% accuracy, and 1 ppm casein in chocolate at 35–51% accuracy. Quantitative estimations of milk from matrix-independent calibration curves in the background of egg white powder as exogenous carrier were comparable to those from a matrix-matched calibration curve, and the quantitative precision was within 30% CV across the inter-day replicates. The sensitivity, accuracy, and precision of this matrix-independent approach ensure robustness of the method for high throughput food allergen analysis as required in routine testing labs. [Display omitted] •LC-MS/MS detected milk protein in matrices at levels relevant for risk assessment.•Matrix-independent calibration was developed for total milk protein quantification.•The method had good quantitative recovery of milk protein from processed matrices.•Longitudinal data demonstrated good within-lab method stability and performance.</abstract><pub>Elsevier Ltd</pub><doi>10.1016/j.foodcont.2024.110444</doi><orcidid>https://orcid.org/0000-0001-8346-6540</orcidid></addata></record>
fulltext fulltext
identifier ISSN: 0956-7135
ispartof Food control, 2024-08, Vol.162, p.110444, Article 110444
issn 0956-7135
1873-7129
language eng
recordid cdi_proquest_miscellaneous_3153793069
source Elsevier ScienceDirect Journals
subjects calibration
casein
chocolate
compliance
cookies
dried skim milk
egg albumen
Food allergen
food allergens
food safety
mass spectrometry
Matrix-independent calibration
milk
Milk protein quantification
pasteurization
peptides
risk
Risk assessment
Tandem mass spectrometry
Targeted proteomics
whey
title Development and validation of a targeted mass spectrometry method for the quantification of milk protein allergens in multiple complex food matrices using matrix-independent calibration
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-02-19T02%3A59%3A29IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Development%20and%20validation%20of%20a%20targeted%20mass%20spectrometry%20method%20for%20the%20quantification%20of%20milk%20protein%20allergens%20in%20multiple%20complex%20food%20matrices%20using%20matrix-independent%20calibration&rft.jtitle=Food%20control&rft.au=Ramachandran,%20Bini&rft.date=2024-08&rft.volume=162&rft.spage=110444&rft.pages=110444-&rft.artnum=110444&rft.issn=0956-7135&rft.eissn=1873-7129&rft_id=info:doi/10.1016/j.foodcont.2024.110444&rft_dat=%3Cproquest_cross%3E3153793069%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=3153793069&rft_id=info:pmid/&rft_els_id=S0956713524001610&rfr_iscdi=true