Enhancing thermal comfort and natural ventilation in residential buildings: A design and assessment of an integrated system with horizontal windcatcher and evaporative cooling channels

In this study, researchers investigated the efficacy of natural cooling in a residential building employing a horizontal windcatcher alongside a direct evaporative cooling system featuring a cross-flow pattern. ANSYS Fluent was used to model the three-dimensional airflow, while MATLAB measured the s...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Energy (Oxford) 2024-02, Vol.289, p.130040, Article 130040
Hauptverfasser: Heidari, Sahar, Poshtiri, Amin Haghighi, Gilvaei, Zoleikha Moghtader
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page
container_issue
container_start_page 130040
container_title Energy (Oxford)
container_volume 289
creator Heidari, Sahar
Poshtiri, Amin Haghighi
Gilvaei, Zoleikha Moghtader
description In this study, researchers investigated the efficacy of natural cooling in a residential building employing a horizontal windcatcher alongside a direct evaporative cooling system featuring a cross-flow pattern. ANSYS Fluent was used to model the three-dimensional airflow, while MATLAB measured the system's thermal performance. The study assessed thermal comfort and natural ventilation in accordance with the Adaptive Thermal Comfort Standard (ATCS) and ISO/EN7730 Standard. The impact of environmental conditions and window aperture on the hybrid system's functionality was scrutinized, culminating in design guidelines dictating the acceptable range of window openings to ensure compliance with thermal comfort conditions. The passive system demonstrated the capability to maintain thermal comfort within the test building under a maximum cooling load of 12,000 W (ATCS) and 6000 W (ISO/EN7730). Moreover, the natural cooling system decreased hourly electricity consumption during hot seasons in Tehran, Iran, by 0.0155 (kW/m2) compared to split air conditioners and 0.00087 (kW/m2) compared to evaporative coolers. The study also investigated the influence of neighboring buildings positioned at specific distances relative to the test building on the system's performance. Furthermore, adopting the suggested horizontal windcatcher instead of conventional vertical windcatchers resulted in a 50 % reduction in energy consumption. [Display omitted] •A novel system for natural ventilation and cooling of residential buildings is presented.•A design guideline determining the allowable windows opening range is proposed.•Thermal comfort is obtained for a maximum of 12,000 W cooling load in the test building.•The system can decrease hourly electric energy consumption by about 0.0155 kW h/m2.
doi_str_mv 10.1016/j.energy.2023.130040
format Article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_3153603500</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><els_id>S0360544223034345</els_id><sourcerecordid>3153603500</sourcerecordid><originalsourceid>FETCH-LOGICAL-c339t-993f16e8d13a1e8d5dac3547fc6091e91b4d8130a9155a48b711928bfdaad4633</originalsourceid><addsrcrecordid>eNp9UctOIzEQnMMikYX9Aw4-7iXBjmeGMYeVEGIfEhIXOFsduydxNGMHtxOU_TI-bzvMnjm1VF1Vqu6qqislF0qq9nq7wIh5fVws5VIvlJayll-qmdStnDd1vTyvvhJtpZRNZ8ysen-IG4guxLUoG8wjDMKlsU-5CIheRCj7zNgBYwkDlJCiCFFkpOBPEK9W-zB41tOtuBOeF-v4IQUiJBqZJVLPCOsKrjMU9IKOVHAUb6FsxCbl8DfFwlZvIXoHxXGQDws8wC6xIhyQU6XhlNJx3IgDXVZnPQyE3_7Pi-rl58Pz_e_549OvP_d3j3OntSlzY3SvWuy80qB4NB6cbuqb3rXSKDRqVfuOvwRGNQ3U3epGKbPsVr0H8HWr9UX1ffLd5fS6Ryp2DORwGCBi2pPVquHX6kZKptYT1eVElLG3uxxGyEerpD2VY7d2KseeyrFTOSz7Mcn4KjwEzJZcwOjQh4yuWJ_C5wb_ABcuoZo</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>3153603500</pqid></control><display><type>article</type><title>Enhancing thermal comfort and natural ventilation in residential buildings: A design and assessment of an integrated system with horizontal windcatcher and evaporative cooling channels</title><source>ScienceDirect Freedom Collection (Elsevier)</source><creator>Heidari, Sahar ; Poshtiri, Amin Haghighi ; Gilvaei, Zoleikha Moghtader</creator><creatorcontrib>Heidari, Sahar ; Poshtiri, Amin Haghighi ; Gilvaei, Zoleikha Moghtader</creatorcontrib><description>In this study, researchers investigated the efficacy of natural cooling in a residential building employing a horizontal windcatcher alongside a direct evaporative cooling system featuring a cross-flow pattern. ANSYS Fluent was used to model the three-dimensional airflow, while MATLAB measured the system's thermal performance. The study assessed thermal comfort and natural ventilation in accordance with the Adaptive Thermal Comfort Standard (ATCS) and ISO/EN7730 Standard. The impact of environmental conditions and window aperture on the hybrid system's functionality was scrutinized, culminating in design guidelines dictating the acceptable range of window openings to ensure compliance with thermal comfort conditions. The passive system demonstrated the capability to maintain thermal comfort within the test building under a maximum cooling load of 12,000 W (ATCS) and 6000 W (ISO/EN7730). Moreover, the natural cooling system decreased hourly electricity consumption during hot seasons in Tehran, Iran, by 0.0155 (kW/m2) compared to split air conditioners and 0.00087 (kW/m2) compared to evaporative coolers. The study also investigated the influence of neighboring buildings positioned at specific distances relative to the test building on the system's performance. Furthermore, adopting the suggested horizontal windcatcher instead of conventional vertical windcatchers resulted in a 50 % reduction in energy consumption. [Display omitted] •A novel system for natural ventilation and cooling of residential buildings is presented.•A design guideline determining the allowable windows opening range is proposed.•Thermal comfort is obtained for a maximum of 12,000 W cooling load in the test building.•The system can decrease hourly electric energy consumption by about 0.0155 kW h/m2.</description><identifier>ISSN: 0360-5442</identifier><identifier>DOI: 10.1016/j.energy.2023.130040</identifier><language>eng</language><publisher>Elsevier Ltd</publisher><subject>air ; air flow ; compliance ; cooling ; Cross flow pattern ; electric energy consumption ; energy ; Evaporative cooling ; Iran ; Natural ventilation ; residential housing ; Windcatcher</subject><ispartof>Energy (Oxford), 2024-02, Vol.289, p.130040, Article 130040</ispartof><rights>2023</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c339t-993f16e8d13a1e8d5dac3547fc6091e91b4d8130a9155a48b711928bfdaad4633</citedby><cites>FETCH-LOGICAL-c339t-993f16e8d13a1e8d5dac3547fc6091e91b4d8130a9155a48b711928bfdaad4633</cites><orcidid>0000-0002-3993-7461</orcidid></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://www.sciencedirect.com/science/article/pii/S0360544223034345$$EHTML$$P50$$Gelsevier$$H</linktohtml><link.rule.ids>314,776,780,3537,27901,27902,65306</link.rule.ids></links><search><creatorcontrib>Heidari, Sahar</creatorcontrib><creatorcontrib>Poshtiri, Amin Haghighi</creatorcontrib><creatorcontrib>Gilvaei, Zoleikha Moghtader</creatorcontrib><title>Enhancing thermal comfort and natural ventilation in residential buildings: A design and assessment of an integrated system with horizontal windcatcher and evaporative cooling channels</title><title>Energy (Oxford)</title><description>In this study, researchers investigated the efficacy of natural cooling in a residential building employing a horizontal windcatcher alongside a direct evaporative cooling system featuring a cross-flow pattern. ANSYS Fluent was used to model the three-dimensional airflow, while MATLAB measured the system's thermal performance. The study assessed thermal comfort and natural ventilation in accordance with the Adaptive Thermal Comfort Standard (ATCS) and ISO/EN7730 Standard. The impact of environmental conditions and window aperture on the hybrid system's functionality was scrutinized, culminating in design guidelines dictating the acceptable range of window openings to ensure compliance with thermal comfort conditions. The passive system demonstrated the capability to maintain thermal comfort within the test building under a maximum cooling load of 12,000 W (ATCS) and 6000 W (ISO/EN7730). Moreover, the natural cooling system decreased hourly electricity consumption during hot seasons in Tehran, Iran, by 0.0155 (kW/m2) compared to split air conditioners and 0.00087 (kW/m2) compared to evaporative coolers. The study also investigated the influence of neighboring buildings positioned at specific distances relative to the test building on the system's performance. Furthermore, adopting the suggested horizontal windcatcher instead of conventional vertical windcatchers resulted in a 50 % reduction in energy consumption. [Display omitted] •A novel system for natural ventilation and cooling of residential buildings is presented.•A design guideline determining the allowable windows opening range is proposed.•Thermal comfort is obtained for a maximum of 12,000 W cooling load in the test building.•The system can decrease hourly electric energy consumption by about 0.0155 kW h/m2.</description><subject>air</subject><subject>air flow</subject><subject>compliance</subject><subject>cooling</subject><subject>Cross flow pattern</subject><subject>electric energy consumption</subject><subject>energy</subject><subject>Evaporative cooling</subject><subject>Iran</subject><subject>Natural ventilation</subject><subject>residential housing</subject><subject>Windcatcher</subject><issn>0360-5442</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2024</creationdate><recordtype>article</recordtype><recordid>eNp9UctOIzEQnMMikYX9Aw4-7iXBjmeGMYeVEGIfEhIXOFsduydxNGMHtxOU_TI-bzvMnjm1VF1Vqu6qqislF0qq9nq7wIh5fVws5VIvlJayll-qmdStnDd1vTyvvhJtpZRNZ8ysen-IG4guxLUoG8wjDMKlsU-5CIheRCj7zNgBYwkDlJCiCFFkpOBPEK9W-zB41tOtuBOeF-v4IQUiJBqZJVLPCOsKrjMU9IKOVHAUb6FsxCbl8DfFwlZvIXoHxXGQDws8wC6xIhyQU6XhlNJx3IgDXVZnPQyE3_7Pi-rl58Pz_e_549OvP_d3j3OntSlzY3SvWuy80qB4NB6cbuqb3rXSKDRqVfuOvwRGNQ3U3epGKbPsVr0H8HWr9UX1ffLd5fS6Ryp2DORwGCBi2pPVquHX6kZKptYT1eVElLG3uxxGyEerpD2VY7d2KseeyrFTOSz7Mcn4KjwEzJZcwOjQh4yuWJ_C5wb_ABcuoZo</recordid><startdate>20240215</startdate><enddate>20240215</enddate><creator>Heidari, Sahar</creator><creator>Poshtiri, Amin Haghighi</creator><creator>Gilvaei, Zoleikha Moghtader</creator><general>Elsevier Ltd</general><scope>AAYXX</scope><scope>CITATION</scope><scope>7S9</scope><scope>L.6</scope><orcidid>https://orcid.org/0000-0002-3993-7461</orcidid></search><sort><creationdate>20240215</creationdate><title>Enhancing thermal comfort and natural ventilation in residential buildings: A design and assessment of an integrated system with horizontal windcatcher and evaporative cooling channels</title><author>Heidari, Sahar ; Poshtiri, Amin Haghighi ; Gilvaei, Zoleikha Moghtader</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c339t-993f16e8d13a1e8d5dac3547fc6091e91b4d8130a9155a48b711928bfdaad4633</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2024</creationdate><topic>air</topic><topic>air flow</topic><topic>compliance</topic><topic>cooling</topic><topic>Cross flow pattern</topic><topic>electric energy consumption</topic><topic>energy</topic><topic>Evaporative cooling</topic><topic>Iran</topic><topic>Natural ventilation</topic><topic>residential housing</topic><topic>Windcatcher</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Heidari, Sahar</creatorcontrib><creatorcontrib>Poshtiri, Amin Haghighi</creatorcontrib><creatorcontrib>Gilvaei, Zoleikha Moghtader</creatorcontrib><collection>CrossRef</collection><collection>AGRICOLA</collection><collection>AGRICOLA - Academic</collection><jtitle>Energy (Oxford)</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Heidari, Sahar</au><au>Poshtiri, Amin Haghighi</au><au>Gilvaei, Zoleikha Moghtader</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Enhancing thermal comfort and natural ventilation in residential buildings: A design and assessment of an integrated system with horizontal windcatcher and evaporative cooling channels</atitle><jtitle>Energy (Oxford)</jtitle><date>2024-02-15</date><risdate>2024</risdate><volume>289</volume><spage>130040</spage><pages>130040-</pages><artnum>130040</artnum><issn>0360-5442</issn><abstract>In this study, researchers investigated the efficacy of natural cooling in a residential building employing a horizontal windcatcher alongside a direct evaporative cooling system featuring a cross-flow pattern. ANSYS Fluent was used to model the three-dimensional airflow, while MATLAB measured the system's thermal performance. The study assessed thermal comfort and natural ventilation in accordance with the Adaptive Thermal Comfort Standard (ATCS) and ISO/EN7730 Standard. The impact of environmental conditions and window aperture on the hybrid system's functionality was scrutinized, culminating in design guidelines dictating the acceptable range of window openings to ensure compliance with thermal comfort conditions. The passive system demonstrated the capability to maintain thermal comfort within the test building under a maximum cooling load of 12,000 W (ATCS) and 6000 W (ISO/EN7730). Moreover, the natural cooling system decreased hourly electricity consumption during hot seasons in Tehran, Iran, by 0.0155 (kW/m2) compared to split air conditioners and 0.00087 (kW/m2) compared to evaporative coolers. The study also investigated the influence of neighboring buildings positioned at specific distances relative to the test building on the system's performance. Furthermore, adopting the suggested horizontal windcatcher instead of conventional vertical windcatchers resulted in a 50 % reduction in energy consumption. [Display omitted] •A novel system for natural ventilation and cooling of residential buildings is presented.•A design guideline determining the allowable windows opening range is proposed.•Thermal comfort is obtained for a maximum of 12,000 W cooling load in the test building.•The system can decrease hourly electric energy consumption by about 0.0155 kW h/m2.</abstract><pub>Elsevier Ltd</pub><doi>10.1016/j.energy.2023.130040</doi><orcidid>https://orcid.org/0000-0002-3993-7461</orcidid></addata></record>
fulltext fulltext
identifier ISSN: 0360-5442
ispartof Energy (Oxford), 2024-02, Vol.289, p.130040, Article 130040
issn 0360-5442
language eng
recordid cdi_proquest_miscellaneous_3153603500
source ScienceDirect Freedom Collection (Elsevier)
subjects air
air flow
compliance
cooling
Cross flow pattern
electric energy consumption
energy
Evaporative cooling
Iran
Natural ventilation
residential housing
Windcatcher
title Enhancing thermal comfort and natural ventilation in residential buildings: A design and assessment of an integrated system with horizontal windcatcher and evaporative cooling channels
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-02-11T22%3A31%3A53IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Enhancing%20thermal%20comfort%20and%20natural%20ventilation%20in%20residential%20buildings:%20A%20design%20and%20assessment%20of%20an%20integrated%20system%20with%20horizontal%20windcatcher%20and%20evaporative%20cooling%20channels&rft.jtitle=Energy%20(Oxford)&rft.au=Heidari,%20Sahar&rft.date=2024-02-15&rft.volume=289&rft.spage=130040&rft.pages=130040-&rft.artnum=130040&rft.issn=0360-5442&rft_id=info:doi/10.1016/j.energy.2023.130040&rft_dat=%3Cproquest_cross%3E3153603500%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=3153603500&rft_id=info:pmid/&rft_els_id=S0360544223034345&rfr_iscdi=true