Ratiometric electrochemical immunoassay based on 2D Co/Fe MOF decorated with toluidine blue and Fc-labeled Schiff base for accurate assay of alpha-fetoprotein in clinical serum

The high level of alpha-fetoprotein (AFP) expression is closely related to hepatocellular carcinoma (HCC). Herein, a dual signal ratiometric electrochemical immunosensor based on chitosan-ferrocenecarboxaldehyde-spindle gold (Chit-Fc-SAu) and Co/Fe metal-organic framework-toluidine blue/polydopamine...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Talanta (Oxford) 2024-06, Vol.273, p.125876-125876, Article 125876
Hauptverfasser: Sun, He-Nan, Wang, Miao, Tan, Hong-Sheng, Liu, Hui-Ping, Liu, Mingjun, Li, Shan-Shan
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 125876
container_issue
container_start_page 125876
container_title Talanta (Oxford)
container_volume 273
creator Sun, He-Nan
Wang, Miao
Tan, Hong-Sheng
Liu, Hui-Ping
Liu, Mingjun
Li, Shan-Shan
description The high level of alpha-fetoprotein (AFP) expression is closely related to hepatocellular carcinoma (HCC). Herein, a dual signal ratiometric electrochemical immunosensor based on chitosan-ferrocenecarboxaldehyde-spindle gold (Chit-Fc-SAu) and Co/Fe metal-organic framework-toluidine blue/polydopamine (Co/Fe MOF-TB/PDA) was proposed for quantitative analysis of AFP. Specifically, Chit-Fc-SAu worked as a substrate to trap more primary antibodies (Ab1) generating the first electrochemical signal from Fc. Thanks to the large specific surface area, the synergistic and electronic effects of Co/Fe MOF nanosheets, and the rich functional groups of PDA, Co/Fe MOF-TB/PDA could load more secondary antibodies (Ab2) and signal molecules (TB) providing another amplified electrochemical signal. In the presence of AFP, Ab1-AFP-Ab2 formed a sandwich structure, and as the AFP concentration increased, the peak current ratio of TB to Fc (ITB/IFc) also increased. The dual signal ratiometric strategy can avoid environmental signal interference and achieve signal self-calibration, thereby improving the accuracy and reproducibility of detection. After a series of exploration, this self-calibrated ratiometric immunosensor exhibited a wide linear range (0.001−200 ng mL−1), a low detection limit (0.34 pg mL−1), and good repeatability. When applied to the assay of clinical serum samples, the detection results of ratiometric sensor were consistent with that of commercial electrochemiluminescence (ECL) immunoassay, significantly superior to that of non-ratiometric sensor. The self-calibrated strategy based on ratiometric sensor helps to improve the accuracy of AFP in clinical diagnosis. [Display omitted] •A dual signal ratiometric electrochemical immunosensor was developed.•Chit-Fc-SAu worked as a substrate to trap Ab1 and generate an electrical signal.•Co/Fe MOF-TB/PDA could load more Ab2 and TB providing another electrical signal.•The ratiometric sensor was comparable to ECL, superior to non-ratiometric sensor.
doi_str_mv 10.1016/j.talanta.2024.125876
format Article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_3153548757</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><els_id>S0039914024002558</els_id><sourcerecordid>3153548757</sourcerecordid><originalsourceid>FETCH-LOGICAL-c398t-7d91837e147bbe7793b6760a81de9b4168d9ce315f82241ddefa7765b028a6303</originalsourceid><addsrcrecordid>eNqFkc1u1DAUhS0EotPCI4C8ZJOpf5LYWSE0MAWpVSVa1pZj32g8cuLBdor6VjwinmbotpKlu_A591ydD6EPlKwpoe3lfp2111PWa0ZYvaaskaJ9hVZUCl7xRvDXaEUI76qO1uQMnae0J4QwTvhbdMZl3Ugi2Qr9_amzCyPk6AwGDybHYHYwOqM9duM4T0GnpB9xrxNYHCbMvuJNuNwCvrndYgsmRJ3Lzx-XdzgHPzvrJsC9nwHryeKtqbzuy2aL78zODcPTJjyEiLUx89GMl4QwYO0PO10NkMMhhgxuwuUZ76ancxLEeXyH3gzaJ3h_mhfo1_bb_eZ7dX179WPz5boyvJO5Erajkgugteh7EKLjfStaoiW10PU1baXtDHDaDJKxmloLgxaibXrCpG5LSxfo07K3XPJ7hpTV6JIBXzqHMCdVrLyppShNvyRlXVMLUXJ4kTaL1MSQUoRBHaIbdXxUlKgjV7VXJ67qyFUtXIvv4yli7kewz67_IIvg8yKA0smDg6iScTAZsC4WqMoG90LEP0jsuDo</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>2954778223</pqid></control><display><type>article</type><title>Ratiometric electrochemical immunoassay based on 2D Co/Fe MOF decorated with toluidine blue and Fc-labeled Schiff base for accurate assay of alpha-fetoprotein in clinical serum</title><source>Elsevier ScienceDirect Journals</source><creator>Sun, He-Nan ; Wang, Miao ; Tan, Hong-Sheng ; Liu, Hui-Ping ; Liu, Mingjun ; Li, Shan-Shan</creator><creatorcontrib>Sun, He-Nan ; Wang, Miao ; Tan, Hong-Sheng ; Liu, Hui-Ping ; Liu, Mingjun ; Li, Shan-Shan</creatorcontrib><description>The high level of alpha-fetoprotein (AFP) expression is closely related to hepatocellular carcinoma (HCC). Herein, a dual signal ratiometric electrochemical immunosensor based on chitosan-ferrocenecarboxaldehyde-spindle gold (Chit-Fc-SAu) and Co/Fe metal-organic framework-toluidine blue/polydopamine (Co/Fe MOF-TB/PDA) was proposed for quantitative analysis of AFP. Specifically, Chit-Fc-SAu worked as a substrate to trap more primary antibodies (Ab1) generating the first electrochemical signal from Fc. Thanks to the large specific surface area, the synergistic and electronic effects of Co/Fe MOF nanosheets, and the rich functional groups of PDA, Co/Fe MOF-TB/PDA could load more secondary antibodies (Ab2) and signal molecules (TB) providing another amplified electrochemical signal. In the presence of AFP, Ab1-AFP-Ab2 formed a sandwich structure, and as the AFP concentration increased, the peak current ratio of TB to Fc (ITB/IFc) also increased. The dual signal ratiometric strategy can avoid environmental signal interference and achieve signal self-calibration, thereby improving the accuracy and reproducibility of detection. After a series of exploration, this self-calibrated ratiometric immunosensor exhibited a wide linear range (0.001−200 ng mL−1), a low detection limit (0.34 pg mL−1), and good repeatability. When applied to the assay of clinical serum samples, the detection results of ratiometric sensor were consistent with that of commercial electrochemiluminescence (ECL) immunoassay, significantly superior to that of non-ratiometric sensor. The self-calibrated strategy based on ratiometric sensor helps to improve the accuracy of AFP in clinical diagnosis. [Display omitted] •A dual signal ratiometric electrochemical immunosensor was developed.•Chit-Fc-SAu worked as a substrate to trap Ab1 and generate an electrical signal.•Co/Fe MOF-TB/PDA could load more Ab2 and TB providing another electrical signal.•The ratiometric sensor was comparable to ECL, superior to non-ratiometric sensor.</description><identifier>ISSN: 0039-9140</identifier><identifier>EISSN: 1873-3573</identifier><identifier>DOI: 10.1016/j.talanta.2024.125876</identifier><identifier>PMID: 38458082</identifier><language>eng</language><publisher>Netherlands: Elsevier B.V</publisher><subject>Alpha-fetoprotein ; blood serum ; Chitosan-ferrocenecarboxaldehyde ; Clinical serum ; Co/Fe metal-organic framework ; detection limit ; electrochemiluminescence ; electrochemistry ; gold ; hepatoma ; immunoassays ; immunosensors ; nanosheets ; quantitative analysis ; Ratiometric electrochemical immunosensor ; schiff bases ; surface area ; toluidine blue</subject><ispartof>Talanta (Oxford), 2024-06, Vol.273, p.125876-125876, Article 125876</ispartof><rights>2024 Elsevier B.V.</rights><rights>Copyright © 2024 Elsevier B.V. All rights reserved.</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c398t-7d91837e147bbe7793b6760a81de9b4168d9ce315f82241ddefa7765b028a6303</citedby><cites>FETCH-LOGICAL-c398t-7d91837e147bbe7793b6760a81de9b4168d9ce315f82241ddefa7765b028a6303</cites><orcidid>0000-0003-1426-1167</orcidid></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://www.sciencedirect.com/science/article/pii/S0039914024002558$$EHTML$$P50$$Gelsevier$$H</linktohtml><link.rule.ids>314,776,780,3536,27902,27903,65308</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/38458082$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Sun, He-Nan</creatorcontrib><creatorcontrib>Wang, Miao</creatorcontrib><creatorcontrib>Tan, Hong-Sheng</creatorcontrib><creatorcontrib>Liu, Hui-Ping</creatorcontrib><creatorcontrib>Liu, Mingjun</creatorcontrib><creatorcontrib>Li, Shan-Shan</creatorcontrib><title>Ratiometric electrochemical immunoassay based on 2D Co/Fe MOF decorated with toluidine blue and Fc-labeled Schiff base for accurate assay of alpha-fetoprotein in clinical serum</title><title>Talanta (Oxford)</title><addtitle>Talanta</addtitle><description>The high level of alpha-fetoprotein (AFP) expression is closely related to hepatocellular carcinoma (HCC). Herein, a dual signal ratiometric electrochemical immunosensor based on chitosan-ferrocenecarboxaldehyde-spindle gold (Chit-Fc-SAu) and Co/Fe metal-organic framework-toluidine blue/polydopamine (Co/Fe MOF-TB/PDA) was proposed for quantitative analysis of AFP. Specifically, Chit-Fc-SAu worked as a substrate to trap more primary antibodies (Ab1) generating the first electrochemical signal from Fc. Thanks to the large specific surface area, the synergistic and electronic effects of Co/Fe MOF nanosheets, and the rich functional groups of PDA, Co/Fe MOF-TB/PDA could load more secondary antibodies (Ab2) and signal molecules (TB) providing another amplified electrochemical signal. In the presence of AFP, Ab1-AFP-Ab2 formed a sandwich structure, and as the AFP concentration increased, the peak current ratio of TB to Fc (ITB/IFc) also increased. The dual signal ratiometric strategy can avoid environmental signal interference and achieve signal self-calibration, thereby improving the accuracy and reproducibility of detection. After a series of exploration, this self-calibrated ratiometric immunosensor exhibited a wide linear range (0.001−200 ng mL−1), a low detection limit (0.34 pg mL−1), and good repeatability. When applied to the assay of clinical serum samples, the detection results of ratiometric sensor were consistent with that of commercial electrochemiluminescence (ECL) immunoassay, significantly superior to that of non-ratiometric sensor. The self-calibrated strategy based on ratiometric sensor helps to improve the accuracy of AFP in clinical diagnosis. [Display omitted] •A dual signal ratiometric electrochemical immunosensor was developed.•Chit-Fc-SAu worked as a substrate to trap Ab1 and generate an electrical signal.•Co/Fe MOF-TB/PDA could load more Ab2 and TB providing another electrical signal.•The ratiometric sensor was comparable to ECL, superior to non-ratiometric sensor.</description><subject>Alpha-fetoprotein</subject><subject>blood serum</subject><subject>Chitosan-ferrocenecarboxaldehyde</subject><subject>Clinical serum</subject><subject>Co/Fe metal-organic framework</subject><subject>detection limit</subject><subject>electrochemiluminescence</subject><subject>electrochemistry</subject><subject>gold</subject><subject>hepatoma</subject><subject>immunoassays</subject><subject>immunosensors</subject><subject>nanosheets</subject><subject>quantitative analysis</subject><subject>Ratiometric electrochemical immunosensor</subject><subject>schiff bases</subject><subject>surface area</subject><subject>toluidine blue</subject><issn>0039-9140</issn><issn>1873-3573</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2024</creationdate><recordtype>article</recordtype><recordid>eNqFkc1u1DAUhS0EotPCI4C8ZJOpf5LYWSE0MAWpVSVa1pZj32g8cuLBdor6VjwinmbotpKlu_A591ydD6EPlKwpoe3lfp2111PWa0ZYvaaskaJ9hVZUCl7xRvDXaEUI76qO1uQMnae0J4QwTvhbdMZl3Ugi2Qr9_amzCyPk6AwGDybHYHYwOqM9duM4T0GnpB9xrxNYHCbMvuJNuNwCvrndYgsmRJ3Lzx-XdzgHPzvrJsC9nwHryeKtqbzuy2aL78zODcPTJjyEiLUx89GMl4QwYO0PO10NkMMhhgxuwuUZ76ancxLEeXyH3gzaJ3h_mhfo1_bb_eZ7dX179WPz5boyvJO5Erajkgugteh7EKLjfStaoiW10PU1baXtDHDaDJKxmloLgxaibXrCpG5LSxfo07K3XPJ7hpTV6JIBXzqHMCdVrLyppShNvyRlXVMLUXJ4kTaL1MSQUoRBHaIbdXxUlKgjV7VXJ67qyFUtXIvv4yli7kewz67_IIvg8yKA0smDg6iScTAZsC4WqMoG90LEP0jsuDo</recordid><startdate>20240601</startdate><enddate>20240601</enddate><creator>Sun, He-Nan</creator><creator>Wang, Miao</creator><creator>Tan, Hong-Sheng</creator><creator>Liu, Hui-Ping</creator><creator>Liu, Mingjun</creator><creator>Li, Shan-Shan</creator><general>Elsevier B.V</general><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope><scope>7S9</scope><scope>L.6</scope><orcidid>https://orcid.org/0000-0003-1426-1167</orcidid></search><sort><creationdate>20240601</creationdate><title>Ratiometric electrochemical immunoassay based on 2D Co/Fe MOF decorated with toluidine blue and Fc-labeled Schiff base for accurate assay of alpha-fetoprotein in clinical serum</title><author>Sun, He-Nan ; Wang, Miao ; Tan, Hong-Sheng ; Liu, Hui-Ping ; Liu, Mingjun ; Li, Shan-Shan</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c398t-7d91837e147bbe7793b6760a81de9b4168d9ce315f82241ddefa7765b028a6303</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2024</creationdate><topic>Alpha-fetoprotein</topic><topic>blood serum</topic><topic>Chitosan-ferrocenecarboxaldehyde</topic><topic>Clinical serum</topic><topic>Co/Fe metal-organic framework</topic><topic>detection limit</topic><topic>electrochemiluminescence</topic><topic>electrochemistry</topic><topic>gold</topic><topic>hepatoma</topic><topic>immunoassays</topic><topic>immunosensors</topic><topic>nanosheets</topic><topic>quantitative analysis</topic><topic>Ratiometric electrochemical immunosensor</topic><topic>schiff bases</topic><topic>surface area</topic><topic>toluidine blue</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Sun, He-Nan</creatorcontrib><creatorcontrib>Wang, Miao</creatorcontrib><creatorcontrib>Tan, Hong-Sheng</creatorcontrib><creatorcontrib>Liu, Hui-Ping</creatorcontrib><creatorcontrib>Liu, Mingjun</creatorcontrib><creatorcontrib>Li, Shan-Shan</creatorcontrib><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><collection>AGRICOLA</collection><collection>AGRICOLA - Academic</collection><jtitle>Talanta (Oxford)</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Sun, He-Nan</au><au>Wang, Miao</au><au>Tan, Hong-Sheng</au><au>Liu, Hui-Ping</au><au>Liu, Mingjun</au><au>Li, Shan-Shan</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Ratiometric electrochemical immunoassay based on 2D Co/Fe MOF decorated with toluidine blue and Fc-labeled Schiff base for accurate assay of alpha-fetoprotein in clinical serum</atitle><jtitle>Talanta (Oxford)</jtitle><addtitle>Talanta</addtitle><date>2024-06-01</date><risdate>2024</risdate><volume>273</volume><spage>125876</spage><epage>125876</epage><pages>125876-125876</pages><artnum>125876</artnum><issn>0039-9140</issn><eissn>1873-3573</eissn><abstract>The high level of alpha-fetoprotein (AFP) expression is closely related to hepatocellular carcinoma (HCC). Herein, a dual signal ratiometric electrochemical immunosensor based on chitosan-ferrocenecarboxaldehyde-spindle gold (Chit-Fc-SAu) and Co/Fe metal-organic framework-toluidine blue/polydopamine (Co/Fe MOF-TB/PDA) was proposed for quantitative analysis of AFP. Specifically, Chit-Fc-SAu worked as a substrate to trap more primary antibodies (Ab1) generating the first electrochemical signal from Fc. Thanks to the large specific surface area, the synergistic and electronic effects of Co/Fe MOF nanosheets, and the rich functional groups of PDA, Co/Fe MOF-TB/PDA could load more secondary antibodies (Ab2) and signal molecules (TB) providing another amplified electrochemical signal. In the presence of AFP, Ab1-AFP-Ab2 formed a sandwich structure, and as the AFP concentration increased, the peak current ratio of TB to Fc (ITB/IFc) also increased. The dual signal ratiometric strategy can avoid environmental signal interference and achieve signal self-calibration, thereby improving the accuracy and reproducibility of detection. After a series of exploration, this self-calibrated ratiometric immunosensor exhibited a wide linear range (0.001−200 ng mL−1), a low detection limit (0.34 pg mL−1), and good repeatability. When applied to the assay of clinical serum samples, the detection results of ratiometric sensor were consistent with that of commercial electrochemiluminescence (ECL) immunoassay, significantly superior to that of non-ratiometric sensor. The self-calibrated strategy based on ratiometric sensor helps to improve the accuracy of AFP in clinical diagnosis. [Display omitted] •A dual signal ratiometric electrochemical immunosensor was developed.•Chit-Fc-SAu worked as a substrate to trap Ab1 and generate an electrical signal.•Co/Fe MOF-TB/PDA could load more Ab2 and TB providing another electrical signal.•The ratiometric sensor was comparable to ECL, superior to non-ratiometric sensor.</abstract><cop>Netherlands</cop><pub>Elsevier B.V</pub><pmid>38458082</pmid><doi>10.1016/j.talanta.2024.125876</doi><tpages>1</tpages><orcidid>https://orcid.org/0000-0003-1426-1167</orcidid></addata></record>
fulltext fulltext
identifier ISSN: 0039-9140
ispartof Talanta (Oxford), 2024-06, Vol.273, p.125876-125876, Article 125876
issn 0039-9140
1873-3573
language eng
recordid cdi_proquest_miscellaneous_3153548757
source Elsevier ScienceDirect Journals
subjects Alpha-fetoprotein
blood serum
Chitosan-ferrocenecarboxaldehyde
Clinical serum
Co/Fe metal-organic framework
detection limit
electrochemiluminescence
electrochemistry
gold
hepatoma
immunoassays
immunosensors
nanosheets
quantitative analysis
Ratiometric electrochemical immunosensor
schiff bases
surface area
toluidine blue
title Ratiometric electrochemical immunoassay based on 2D Co/Fe MOF decorated with toluidine blue and Fc-labeled Schiff base for accurate assay of alpha-fetoprotein in clinical serum
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-27T08%3A22%3A31IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Ratiometric%20electrochemical%20immunoassay%20based%20on%202D%20Co/Fe%20MOF%20decorated%20with%20toluidine%20blue%20and%20Fc-labeled%20Schiff%20base%20for%20accurate%20assay%20of%20alpha-fetoprotein%20in%20clinical%20serum&rft.jtitle=Talanta%20(Oxford)&rft.au=Sun,%20He-Nan&rft.date=2024-06-01&rft.volume=273&rft.spage=125876&rft.epage=125876&rft.pages=125876-125876&rft.artnum=125876&rft.issn=0039-9140&rft.eissn=1873-3573&rft_id=info:doi/10.1016/j.talanta.2024.125876&rft_dat=%3Cproquest_cross%3E3153548757%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=2954778223&rft_id=info:pmid/38458082&rft_els_id=S0039914024002558&rfr_iscdi=true