Design and assessment of energy management strategy on rail coaches using solar PV and battery storage to reduce diesel fuel consumption
This study is focused to develop energy management strategy using battery backup source for electrical load of the rail coaches. To assess the effectiveness of battery storage inclusion, the higher and lower battery state of charge cases were simulated using parametric approach where solar Photovolt...
Gespeichert in:
Veröffentlicht in: | Energy (Oxford) 2024-02, Vol.288, p.129718, Article 129718 |
---|---|
Hauptverfasser: | , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
container_end_page | |
---|---|
container_issue | |
container_start_page | 129718 |
container_title | Energy (Oxford) |
container_volume | 288 |
creator | Sipra, Abdullah Tariq Azeem, Fawad Memon, Zulfiqar Ali Baig, Sobia Jaffery, Mujtaba Hussain |
description | This study is focused to develop energy management strategy using battery backup source for electrical load of the rail coaches. To assess the effectiveness of battery storage inclusion, the higher and lower battery state of charge cases were simulated using parametric approach where solar Photovoltaic (PV) power, battery state of charge (SoC) and load consumption parameters were used develop the controller. Fuzzy logic and Adaptive neuro-fuzzy interference system (ANFIS) approaches were used for the controller design. It was found that the Solar PV-battery hybrid system helps in a significant reduction in diesel consumption i.e., about 10 % in diesel savings with higher SoC values and 7 % of diesel savings during worst cases. Annually, while comparing two controllers, it was found that the annual diesel savings increase from PKR 604.17 million to PKR 684.00 million, while the amount of CO₂ emissions reduction increase from 6932.70 to 7848.75 tons, while using ANFIS control. |
doi_str_mv | 10.1016/j.energy.2023.129718 |
format | Article |
fullrecord | <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_3153161320</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>3153161320</sourcerecordid><originalsourceid>FETCH-LOGICAL-c233t-5b01e6120cab2918f6b04d83650f753bccd813ba38af38f06eb79309636f0c993</originalsourceid><addsrcrecordid>eNotkL1OwzAUhTOARCm8AYNHlpTrOHGTEZVfqRIMwGo5znVIldjF1xn6Bjw2acN0pKNzvuFLkhsOKw5c3u1W6DC0h1UGmVjxrFrz8ixZgJCQFnmeXSSXRDsAKMqqWiS_D0hd65h2DdNESDSgi8xbNmPYoJ1u8VRSDDri1HnHgu56Zrw230hspM61jHyvA3v_OrFqHSOGw_TxYfqz6FnAZjTImg4Je2ZHPAIcjcM-dt5dJedW94TX_7lMPp8ePzYv6fbt-XVzv01NJkRMixo4Sp6B0XVW8dLKGvKmFLIAuy5EbUxTclFrUWorSgsS63UloJJCWjBVJZbJ7czdB_8zIkU1dGSw77VDP5ISvBBccpHBNM3nqQmeKKBV-9ANOhwUB3WUrXZqtqSOstUsW_wBhAp5Yg</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>3153161320</pqid></control><display><type>article</type><title>Design and assessment of energy management strategy on rail coaches using solar PV and battery storage to reduce diesel fuel consumption</title><source>Elsevier ScienceDirect Journals</source><creator>Sipra, Abdullah Tariq ; Azeem, Fawad ; Memon, Zulfiqar Ali ; Baig, Sobia ; Jaffery, Mujtaba Hussain</creator><creatorcontrib>Sipra, Abdullah Tariq ; Azeem, Fawad ; Memon, Zulfiqar Ali ; Baig, Sobia ; Jaffery, Mujtaba Hussain</creatorcontrib><description>This study is focused to develop energy management strategy using battery backup source for electrical load of the rail coaches. To assess the effectiveness of battery storage inclusion, the higher and lower battery state of charge cases were simulated using parametric approach where solar Photovoltaic (PV) power, battery state of charge (SoC) and load consumption parameters were used develop the controller. Fuzzy logic and Adaptive neuro-fuzzy interference system (ANFIS) approaches were used for the controller design. It was found that the Solar PV-battery hybrid system helps in a significant reduction in diesel consumption i.e., about 10 % in diesel savings with higher SoC values and 7 % of diesel savings during worst cases. Annually, while comparing two controllers, it was found that the annual diesel savings increase from PKR 604.17 million to PKR 684.00 million, while the amount of CO₂ emissions reduction increase from 6932.70 to 7848.75 tons, while using ANFIS control.</description><identifier>ISSN: 0360-5442</identifier><identifier>DOI: 10.1016/j.energy.2023.129718</identifier><language>eng</language><subject>batteries ; carbon dioxide ; diesel fuel ; energy ; energy use and consumption ; fuzzy logic</subject><ispartof>Energy (Oxford), 2024-02, Vol.288, p.129718, Article 129718</ispartof><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><cites>FETCH-LOGICAL-c233t-5b01e6120cab2918f6b04d83650f753bccd813ba38af38f06eb79309636f0c993</cites><orcidid>0000-0002-1951-4568 ; 0000-0001-7403-7576</orcidid></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,776,780,27903,27904</link.rule.ids></links><search><creatorcontrib>Sipra, Abdullah Tariq</creatorcontrib><creatorcontrib>Azeem, Fawad</creatorcontrib><creatorcontrib>Memon, Zulfiqar Ali</creatorcontrib><creatorcontrib>Baig, Sobia</creatorcontrib><creatorcontrib>Jaffery, Mujtaba Hussain</creatorcontrib><title>Design and assessment of energy management strategy on rail coaches using solar PV and battery storage to reduce diesel fuel consumption</title><title>Energy (Oxford)</title><description>This study is focused to develop energy management strategy using battery backup source for electrical load of the rail coaches. To assess the effectiveness of battery storage inclusion, the higher and lower battery state of charge cases were simulated using parametric approach where solar Photovoltaic (PV) power, battery state of charge (SoC) and load consumption parameters were used develop the controller. Fuzzy logic and Adaptive neuro-fuzzy interference system (ANFIS) approaches were used for the controller design. It was found that the Solar PV-battery hybrid system helps in a significant reduction in diesel consumption i.e., about 10 % in diesel savings with higher SoC values and 7 % of diesel savings during worst cases. Annually, while comparing two controllers, it was found that the annual diesel savings increase from PKR 604.17 million to PKR 684.00 million, while the amount of CO₂ emissions reduction increase from 6932.70 to 7848.75 tons, while using ANFIS control.</description><subject>batteries</subject><subject>carbon dioxide</subject><subject>diesel fuel</subject><subject>energy</subject><subject>energy use and consumption</subject><subject>fuzzy logic</subject><issn>0360-5442</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2024</creationdate><recordtype>article</recordtype><recordid>eNotkL1OwzAUhTOARCm8AYNHlpTrOHGTEZVfqRIMwGo5znVIldjF1xn6Bjw2acN0pKNzvuFLkhsOKw5c3u1W6DC0h1UGmVjxrFrz8ixZgJCQFnmeXSSXRDsAKMqqWiS_D0hd65h2DdNESDSgi8xbNmPYoJ1u8VRSDDri1HnHgu56Zrw230hspM61jHyvA3v_OrFqHSOGw_TxYfqz6FnAZjTImg4Je2ZHPAIcjcM-dt5dJedW94TX_7lMPp8ePzYv6fbt-XVzv01NJkRMixo4Sp6B0XVW8dLKGvKmFLIAuy5EbUxTclFrUWorSgsS63UloJJCWjBVJZbJ7czdB_8zIkU1dGSw77VDP5ISvBBccpHBNM3nqQmeKKBV-9ANOhwUB3WUrXZqtqSOstUsW_wBhAp5Yg</recordid><startdate>20240201</startdate><enddate>20240201</enddate><creator>Sipra, Abdullah Tariq</creator><creator>Azeem, Fawad</creator><creator>Memon, Zulfiqar Ali</creator><creator>Baig, Sobia</creator><creator>Jaffery, Mujtaba Hussain</creator><scope>AAYXX</scope><scope>CITATION</scope><scope>7S9</scope><scope>L.6</scope><orcidid>https://orcid.org/0000-0002-1951-4568</orcidid><orcidid>https://orcid.org/0000-0001-7403-7576</orcidid></search><sort><creationdate>20240201</creationdate><title>Design and assessment of energy management strategy on rail coaches using solar PV and battery storage to reduce diesel fuel consumption</title><author>Sipra, Abdullah Tariq ; Azeem, Fawad ; Memon, Zulfiqar Ali ; Baig, Sobia ; Jaffery, Mujtaba Hussain</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c233t-5b01e6120cab2918f6b04d83650f753bccd813ba38af38f06eb79309636f0c993</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2024</creationdate><topic>batteries</topic><topic>carbon dioxide</topic><topic>diesel fuel</topic><topic>energy</topic><topic>energy use and consumption</topic><topic>fuzzy logic</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Sipra, Abdullah Tariq</creatorcontrib><creatorcontrib>Azeem, Fawad</creatorcontrib><creatorcontrib>Memon, Zulfiqar Ali</creatorcontrib><creatorcontrib>Baig, Sobia</creatorcontrib><creatorcontrib>Jaffery, Mujtaba Hussain</creatorcontrib><collection>CrossRef</collection><collection>AGRICOLA</collection><collection>AGRICOLA - Academic</collection><jtitle>Energy (Oxford)</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Sipra, Abdullah Tariq</au><au>Azeem, Fawad</au><au>Memon, Zulfiqar Ali</au><au>Baig, Sobia</au><au>Jaffery, Mujtaba Hussain</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Design and assessment of energy management strategy on rail coaches using solar PV and battery storage to reduce diesel fuel consumption</atitle><jtitle>Energy (Oxford)</jtitle><date>2024-02-01</date><risdate>2024</risdate><volume>288</volume><spage>129718</spage><pages>129718-</pages><artnum>129718</artnum><issn>0360-5442</issn><abstract>This study is focused to develop energy management strategy using battery backup source for electrical load of the rail coaches. To assess the effectiveness of battery storage inclusion, the higher and lower battery state of charge cases were simulated using parametric approach where solar Photovoltaic (PV) power, battery state of charge (SoC) and load consumption parameters were used develop the controller. Fuzzy logic and Adaptive neuro-fuzzy interference system (ANFIS) approaches were used for the controller design. It was found that the Solar PV-battery hybrid system helps in a significant reduction in diesel consumption i.e., about 10 % in diesel savings with higher SoC values and 7 % of diesel savings during worst cases. Annually, while comparing two controllers, it was found that the annual diesel savings increase from PKR 604.17 million to PKR 684.00 million, while the amount of CO₂ emissions reduction increase from 6932.70 to 7848.75 tons, while using ANFIS control.</abstract><doi>10.1016/j.energy.2023.129718</doi><orcidid>https://orcid.org/0000-0002-1951-4568</orcidid><orcidid>https://orcid.org/0000-0001-7403-7576</orcidid></addata></record> |
fulltext | fulltext |
identifier | ISSN: 0360-5442 |
ispartof | Energy (Oxford), 2024-02, Vol.288, p.129718, Article 129718 |
issn | 0360-5442 |
language | eng |
recordid | cdi_proquest_miscellaneous_3153161320 |
source | Elsevier ScienceDirect Journals |
subjects | batteries carbon dioxide diesel fuel energy energy use and consumption fuzzy logic |
title | Design and assessment of energy management strategy on rail coaches using solar PV and battery storage to reduce diesel fuel consumption |
url | https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-24T00%3A20%3A03IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Design%20and%20assessment%20of%20energy%20management%20strategy%20on%20rail%20coaches%20using%20solar%20PV%20and%20battery%20storage%20to%20reduce%20diesel%20fuel%20consumption&rft.jtitle=Energy%20(Oxford)&rft.au=Sipra,%20Abdullah%20Tariq&rft.date=2024-02-01&rft.volume=288&rft.spage=129718&rft.pages=129718-&rft.artnum=129718&rft.issn=0360-5442&rft_id=info:doi/10.1016/j.energy.2023.129718&rft_dat=%3Cproquest_cross%3E3153161320%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=3153161320&rft_id=info:pmid/&rfr_iscdi=true |