Equipping a Wyatt multiangle, multidetector instrument for real-time particle and polymer sizing by simultaneous multiple-angle dynamic and static light scattering

Well-constructed instruments may continue to perform beyond their manufacturer-supported service lifetime, which is typically limited by computer operating system compatibility or the availability of spare parts. Often, such equipment is condemned to surplus and destroyed. End-of-life plans that ret...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Review of scientific instruments 2024-12, Vol.95 (12)
Hauptverfasser: Zhang, Xujun, Hicks, Daniel, Liu, Honglin, Glover, Natalie, Zhang, Zhaoxian, Grant, Arshay J., Diggs, Monneh, Schmidt-Krey, Ingeborg, Russo, Paul S.
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page
container_issue 12
container_start_page
container_title Review of scientific instruments
container_volume 95
creator Zhang, Xujun
Hicks, Daniel
Liu, Honglin
Glover, Natalie
Zhang, Zhaoxian
Grant, Arshay J.
Diggs, Monneh
Schmidt-Krey, Ingeborg
Russo, Paul S.
description Well-constructed instruments may continue to perform beyond their manufacturer-supported service lifetime, which is typically limited by computer operating system compatibility or the availability of spare parts. Often, such equipment is condemned to surplus and destroyed. End-of-life plans that retain some of the material and energy used to create scientific instruments are of interest, just as in other manufacturing sectors. This is especially true when an instrument can be given new capabilities beyond those for which it was originally designed, maybe even surpassing newly built models. We report the “upcycling” of a Wyatt multiangle, multidetector instrument designed for static light scattering (SLS). The instrument retains SLS capability but was extended to multiangle, multidetector, multicorrelator dynamic light scattering operation by adding readily available fiber optics, detectors, and a modern, multichannel autocorrelator. Because one of the main catalysts of obsolescence is software compatibility, data processing was implemented with the stable Microsoft Excel platform, including a graphical user interface. Instrument performance is demonstrated with microemulsions, protein and polymer solutions, suspensions of latex particles, and suspensions of cellulose nanocrystals.
doi_str_mv 10.1063/5.0225923
format Article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_3148840610</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>3148886566</sourcerecordid><originalsourceid>FETCH-LOGICAL-c238t-19de2c450a0d4829f3452bbd82bcd34d7947a71f6ea9b8d16c498d36d2e50fa83</originalsourceid><addsrcrecordid>eNp9kc1u1TAQRi0EoreFBS-ALLEBRIr_4jhLVLUUqRIbEMvIsScXV46T2s4ifZ2-KL7NhQWLeuOxdHxmNB9Cbyg5p0Tyz_U5YaxuGX-GdpSotmok48_RjhAuKtkIdYJOU7ol5dSUvkQnvG2oEqTZoYfLu8XNswt7rPGvVeeMx8Vnp8Pew6ettpDB5CliF1KOywgh46E8I2hfZTcCnnXMznjAOlg8T34dIeLk7g_afi3VwaMDTEvalLOH6rEFtmvQozOPP1PWRYO92__OOJkyDMSieIVeDNoneH28z9DPq8sfF9fVzfev3y6-3FSGcZUr2lpgRtREEysUawcuatb3VrHeWC5s04pGN3SQoNteWSqNaJXl0jKoyaAVP0PvN-8cp7sFUu5Glwx4v03ecSpU2ZqkpKDv_kNvpyWGMt1GKVlLWagPG2XilFKEoZujG3VcO0q6Q3Jd3R2TK-zbo3HpR7D_yL9RFeDjBiTjDnuawhO2P2g4pCw</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>3148886566</pqid></control><display><type>article</type><title>Equipping a Wyatt multiangle, multidetector instrument for real-time particle and polymer sizing by simultaneous multiple-angle dynamic and static light scattering</title><source>AIP Journals Complete</source><creator>Zhang, Xujun ; Hicks, Daniel ; Liu, Honglin ; Glover, Natalie ; Zhang, Zhaoxian ; Grant, Arshay J. ; Diggs, Monneh ; Schmidt-Krey, Ingeborg ; Russo, Paul S.</creator><creatorcontrib>Zhang, Xujun ; Hicks, Daniel ; Liu, Honglin ; Glover, Natalie ; Zhang, Zhaoxian ; Grant, Arshay J. ; Diggs, Monneh ; Schmidt-Krey, Ingeborg ; Russo, Paul S.</creatorcontrib><description>Well-constructed instruments may continue to perform beyond their manufacturer-supported service lifetime, which is typically limited by computer operating system compatibility or the availability of spare parts. Often, such equipment is condemned to surplus and destroyed. End-of-life plans that retain some of the material and energy used to create scientific instruments are of interest, just as in other manufacturing sectors. This is especially true when an instrument can be given new capabilities beyond those for which it was originally designed, maybe even surpassing newly built models. We report the “upcycling” of a Wyatt multiangle, multidetector instrument designed for static light scattering (SLS). The instrument retains SLS capability but was extended to multiangle, multidetector, multicorrelator dynamic light scattering operation by adding readily available fiber optics, detectors, and a modern, multichannel autocorrelator. Because one of the main catalysts of obsolescence is software compatibility, data processing was implemented with the stable Microsoft Excel platform, including a graphical user interface. Instrument performance is demonstrated with microemulsions, protein and polymer solutions, suspensions of latex particles, and suspensions of cellulose nanocrystals.</description><identifier>ISSN: 0034-6748</identifier><identifier>ISSN: 1089-7623</identifier><identifier>EISSN: 1089-7623</identifier><identifier>DOI: 10.1063/5.0225923</identifier><identifier>PMID: 39718407</identifier><identifier>CODEN: RSINAK</identifier><language>eng</language><publisher>United States: American Institute of Physics</publisher><subject>Availability ; Compatibility ; Data processing ; End of life ; Fiber optics ; Graphical user interface ; Latex ; Photon correlation spectroscopy ; Polymers ; Real time ; Scattering ; Service life</subject><ispartof>Review of scientific instruments, 2024-12, Vol.95 (12)</ispartof><rights>Author(s)</rights><rights>2024 Author(s). Published under an exclusive license by AIP Publishing.</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><cites>FETCH-LOGICAL-c238t-19de2c450a0d4829f3452bbd82bcd34d7947a71f6ea9b8d16c498d36d2e50fa83</cites><orcidid>0000-0001-5822-8938 ; 0000-0001-6009-2742 ; 0000-0002-2882-9975 ; 0009-0006-3072-9160 ; 0009-0005-7017-3956 ; 0000-0002-6408-2776 ; 0000-0003-3759-4714 ; 0000-0003-0534-8789 ; 0009-0007-3299-7254</orcidid></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://pubs.aip.org/rsi/article-lookup/doi/10.1063/5.0225923$$EHTML$$P50$$Gscitation$$H</linktohtml><link.rule.ids>314,776,780,790,4498,27903,27904,76130</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/39718407$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Zhang, Xujun</creatorcontrib><creatorcontrib>Hicks, Daniel</creatorcontrib><creatorcontrib>Liu, Honglin</creatorcontrib><creatorcontrib>Glover, Natalie</creatorcontrib><creatorcontrib>Zhang, Zhaoxian</creatorcontrib><creatorcontrib>Grant, Arshay J.</creatorcontrib><creatorcontrib>Diggs, Monneh</creatorcontrib><creatorcontrib>Schmidt-Krey, Ingeborg</creatorcontrib><creatorcontrib>Russo, Paul S.</creatorcontrib><title>Equipping a Wyatt multiangle, multidetector instrument for real-time particle and polymer sizing by simultaneous multiple-angle dynamic and static light scattering</title><title>Review of scientific instruments</title><addtitle>Rev Sci Instrum</addtitle><description>Well-constructed instruments may continue to perform beyond their manufacturer-supported service lifetime, which is typically limited by computer operating system compatibility or the availability of spare parts. Often, such equipment is condemned to surplus and destroyed. End-of-life plans that retain some of the material and energy used to create scientific instruments are of interest, just as in other manufacturing sectors. This is especially true when an instrument can be given new capabilities beyond those for which it was originally designed, maybe even surpassing newly built models. We report the “upcycling” of a Wyatt multiangle, multidetector instrument designed for static light scattering (SLS). The instrument retains SLS capability but was extended to multiangle, multidetector, multicorrelator dynamic light scattering operation by adding readily available fiber optics, detectors, and a modern, multichannel autocorrelator. Because one of the main catalysts of obsolescence is software compatibility, data processing was implemented with the stable Microsoft Excel platform, including a graphical user interface. Instrument performance is demonstrated with microemulsions, protein and polymer solutions, suspensions of latex particles, and suspensions of cellulose nanocrystals.</description><subject>Availability</subject><subject>Compatibility</subject><subject>Data processing</subject><subject>End of life</subject><subject>Fiber optics</subject><subject>Graphical user interface</subject><subject>Latex</subject><subject>Photon correlation spectroscopy</subject><subject>Polymers</subject><subject>Real time</subject><subject>Scattering</subject><subject>Service life</subject><issn>0034-6748</issn><issn>1089-7623</issn><issn>1089-7623</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2024</creationdate><recordtype>article</recordtype><recordid>eNp9kc1u1TAQRi0EoreFBS-ALLEBRIr_4jhLVLUUqRIbEMvIsScXV46T2s4ifZ2-KL7NhQWLeuOxdHxmNB9Cbyg5p0Tyz_U5YaxuGX-GdpSotmok48_RjhAuKtkIdYJOU7ol5dSUvkQnvG2oEqTZoYfLu8XNswt7rPGvVeeMx8Vnp8Pew6ettpDB5CliF1KOywgh46E8I2hfZTcCnnXMznjAOlg8T34dIeLk7g_afi3VwaMDTEvalLOH6rEFtmvQozOPP1PWRYO92__OOJkyDMSieIVeDNoneH28z9DPq8sfF9fVzfev3y6-3FSGcZUr2lpgRtREEysUawcuatb3VrHeWC5s04pGN3SQoNteWSqNaJXl0jKoyaAVP0PvN-8cp7sFUu5Glwx4v03ecSpU2ZqkpKDv_kNvpyWGMt1GKVlLWagPG2XilFKEoZujG3VcO0q6Q3Jd3R2TK-zbo3HpR7D_yL9RFeDjBiTjDnuawhO2P2g4pCw</recordid><startdate>20241201</startdate><enddate>20241201</enddate><creator>Zhang, Xujun</creator><creator>Hicks, Daniel</creator><creator>Liu, Honglin</creator><creator>Glover, Natalie</creator><creator>Zhang, Zhaoxian</creator><creator>Grant, Arshay J.</creator><creator>Diggs, Monneh</creator><creator>Schmidt-Krey, Ingeborg</creator><creator>Russo, Paul S.</creator><general>American Institute of Physics</general><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>8FD</scope><scope>H8D</scope><scope>L7M</scope><scope>7X8</scope><orcidid>https://orcid.org/0000-0001-5822-8938</orcidid><orcidid>https://orcid.org/0000-0001-6009-2742</orcidid><orcidid>https://orcid.org/0000-0002-2882-9975</orcidid><orcidid>https://orcid.org/0009-0006-3072-9160</orcidid><orcidid>https://orcid.org/0009-0005-7017-3956</orcidid><orcidid>https://orcid.org/0000-0002-6408-2776</orcidid><orcidid>https://orcid.org/0000-0003-3759-4714</orcidid><orcidid>https://orcid.org/0000-0003-0534-8789</orcidid><orcidid>https://orcid.org/0009-0007-3299-7254</orcidid></search><sort><creationdate>20241201</creationdate><title>Equipping a Wyatt multiangle, multidetector instrument for real-time particle and polymer sizing by simultaneous multiple-angle dynamic and static light scattering</title><author>Zhang, Xujun ; Hicks, Daniel ; Liu, Honglin ; Glover, Natalie ; Zhang, Zhaoxian ; Grant, Arshay J. ; Diggs, Monneh ; Schmidt-Krey, Ingeborg ; Russo, Paul S.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c238t-19de2c450a0d4829f3452bbd82bcd34d7947a71f6ea9b8d16c498d36d2e50fa83</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2024</creationdate><topic>Availability</topic><topic>Compatibility</topic><topic>Data processing</topic><topic>End of life</topic><topic>Fiber optics</topic><topic>Graphical user interface</topic><topic>Latex</topic><topic>Photon correlation spectroscopy</topic><topic>Polymers</topic><topic>Real time</topic><topic>Scattering</topic><topic>Service life</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Zhang, Xujun</creatorcontrib><creatorcontrib>Hicks, Daniel</creatorcontrib><creatorcontrib>Liu, Honglin</creatorcontrib><creatorcontrib>Glover, Natalie</creatorcontrib><creatorcontrib>Zhang, Zhaoxian</creatorcontrib><creatorcontrib>Grant, Arshay J.</creatorcontrib><creatorcontrib>Diggs, Monneh</creatorcontrib><creatorcontrib>Schmidt-Krey, Ingeborg</creatorcontrib><creatorcontrib>Russo, Paul S.</creatorcontrib><collection>PubMed</collection><collection>CrossRef</collection><collection>Technology Research Database</collection><collection>Aerospace Database</collection><collection>Advanced Technologies Database with Aerospace</collection><collection>MEDLINE - Academic</collection><jtitle>Review of scientific instruments</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Zhang, Xujun</au><au>Hicks, Daniel</au><au>Liu, Honglin</au><au>Glover, Natalie</au><au>Zhang, Zhaoxian</au><au>Grant, Arshay J.</au><au>Diggs, Monneh</au><au>Schmidt-Krey, Ingeborg</au><au>Russo, Paul S.</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Equipping a Wyatt multiangle, multidetector instrument for real-time particle and polymer sizing by simultaneous multiple-angle dynamic and static light scattering</atitle><jtitle>Review of scientific instruments</jtitle><addtitle>Rev Sci Instrum</addtitle><date>2024-12-01</date><risdate>2024</risdate><volume>95</volume><issue>12</issue><issn>0034-6748</issn><issn>1089-7623</issn><eissn>1089-7623</eissn><coden>RSINAK</coden><abstract>Well-constructed instruments may continue to perform beyond their manufacturer-supported service lifetime, which is typically limited by computer operating system compatibility or the availability of spare parts. Often, such equipment is condemned to surplus and destroyed. End-of-life plans that retain some of the material and energy used to create scientific instruments are of interest, just as in other manufacturing sectors. This is especially true when an instrument can be given new capabilities beyond those for which it was originally designed, maybe even surpassing newly built models. We report the “upcycling” of a Wyatt multiangle, multidetector instrument designed for static light scattering (SLS). The instrument retains SLS capability but was extended to multiangle, multidetector, multicorrelator dynamic light scattering operation by adding readily available fiber optics, detectors, and a modern, multichannel autocorrelator. Because one of the main catalysts of obsolescence is software compatibility, data processing was implemented with the stable Microsoft Excel platform, including a graphical user interface. Instrument performance is demonstrated with microemulsions, protein and polymer solutions, suspensions of latex particles, and suspensions of cellulose nanocrystals.</abstract><cop>United States</cop><pub>American Institute of Physics</pub><pmid>39718407</pmid><doi>10.1063/5.0225923</doi><tpages>15</tpages><orcidid>https://orcid.org/0000-0001-5822-8938</orcidid><orcidid>https://orcid.org/0000-0001-6009-2742</orcidid><orcidid>https://orcid.org/0000-0002-2882-9975</orcidid><orcidid>https://orcid.org/0009-0006-3072-9160</orcidid><orcidid>https://orcid.org/0009-0005-7017-3956</orcidid><orcidid>https://orcid.org/0000-0002-6408-2776</orcidid><orcidid>https://orcid.org/0000-0003-3759-4714</orcidid><orcidid>https://orcid.org/0000-0003-0534-8789</orcidid><orcidid>https://orcid.org/0009-0007-3299-7254</orcidid></addata></record>
fulltext fulltext
identifier ISSN: 0034-6748
ispartof Review of scientific instruments, 2024-12, Vol.95 (12)
issn 0034-6748
1089-7623
1089-7623
language eng
recordid cdi_proquest_miscellaneous_3148840610
source AIP Journals Complete
subjects Availability
Compatibility
Data processing
End of life
Fiber optics
Graphical user interface
Latex
Photon correlation spectroscopy
Polymers
Real time
Scattering
Service life
title Equipping a Wyatt multiangle, multidetector instrument for real-time particle and polymer sizing by simultaneous multiple-angle dynamic and static light scattering
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-27T12%3A31%3A52IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Equipping%20a%20Wyatt%20multiangle,%20multidetector%20instrument%20for%20real-time%20particle%20and%20polymer%20sizing%20by%20simultaneous%20multiple-angle%20dynamic%20and%20static%20light%20scattering&rft.jtitle=Review%20of%20scientific%20instruments&rft.au=Zhang,%20Xujun&rft.date=2024-12-01&rft.volume=95&rft.issue=12&rft.issn=0034-6748&rft.eissn=1089-7623&rft.coden=RSINAK&rft_id=info:doi/10.1063/5.0225923&rft_dat=%3Cproquest_cross%3E3148886566%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=3148886566&rft_id=info:pmid/39718407&rfr_iscdi=true