Total knee arthroplasty improves energy conversion efficiency during walking in patients with knee osteoarthritis

Energy conversion efficiency of human gait can be evaluated by calculating the ratio of conversion of mechanical energy from vertical motion to horizontal motion of the center of gravity through the movement of the joints. Osteoarthritis (OA) of the knee joint impairs this energy conversion efficien...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:The knee 2025-03, Vol.53, p.42-48
Hauptverfasser: Ida, Ruido, Kuroyanagi, Gen, Ueki, Yoshino, Murakami, Satona, Shiraki, Takayuki, Shimotori, Daiki, Okamoto, Hideki, Yamada, Kunio
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 48
container_issue
container_start_page 42
container_title The knee
container_volume 53
creator Ida, Ruido
Kuroyanagi, Gen
Ueki, Yoshino
Murakami, Satona
Shiraki, Takayuki
Shimotori, Daiki
Okamoto, Hideki
Yamada, Kunio
description Energy conversion efficiency of human gait can be evaluated by calculating the ratio of conversion of mechanical energy from vertical motion to horizontal motion of the center of gravity through the movement of the joints. Osteoarthritis (OA) of the knee joint impairs this energy conversion efficiency. Total knee arthroplasty is the standard treatment for knee OA. However, its effect on energy conversion efficiency is unclear. In this study, we investigated how energy conversion efficiency changed in the gait of patients with knee OA before and after surgery. Twelve patients with unilateral knee OA who underwent total knee arthroplasty were included. Ground walking was measured using a motion capture system (VICON®) before and 6 months after surgery. We calculated potential and kinetic energy from the coordinate change of the center of mass to obtain energy conversion efficiency. Other gait parameters such as gait speed, vertical movement distance of the body center, step length, hip joint angle, and trailing and leading limb angles were assessed. Energy conversion efficiency on the operated side significantly improved from 41.4 ± 12.2% to 57.5 ± 9.2% 6 months after surgery. Other gait parameters on the operated side were significantly improved after surgery compared with before surgery. Step length on the operated and the non-operated sides and trailing limb angles on the non-operated side before surgery correlated to energy conversion efficiency, while at 6 months after surgery, gait speed and step length on the non-operated side correlated to energy conversion efficiency. Energy conversion efficiency was strongly improved postoperatively in patients with knee OA.
doi_str_mv 10.1016/j.knee.2024.11.020
format Article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_3146663095</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><els_id>S0968016024002370</els_id><sourcerecordid>3146663095</sourcerecordid><originalsourceid>FETCH-LOGICAL-c237t-3bc5d9b992c7df55af3da5fa5eb00317292c3f59ee5f666394dbee51a25a39cf3</originalsourceid><addsrcrecordid>eNp9kEtPwzAQhC0EgvL4AxyQj1wS1nGd1BIXhHhJSFzgbDnOGlzSuNhuUf89DgWOnGalnfmkGUJOGZQMWH0xL98HxLKCaloyVkIFO2TCZg0vxAxgl0xA1rMiO-GAHMY4B4BaTsU-OeCyrhsGfEI-nn3SPR1BVIf0Fvyy1zFtqFssg19jpDhgeN1Q44c1huj8QNFaZxwOZkO7VXDDK_3U_fuobqBLnfIrRfrp0tuW62NC_w13ycVjsmd1H_HkR4_Iy-3N8_V98fh093B99ViYijep4K0RnWylrEzTWSG05Z0WVgtsAThrqvzgVkhEYeu65nLatflmuhKaS2P5ETnfcnOPjxXGpBYuGux7PaBfRcXZdMyBFNlaba0m-BgDWrUMbqHDRjFQ49RqrsYmapxaMaby1Dl09sNftQvs_iK_22bD5daAueXaYVDxezXsXECTVOfdf_wvXdmTYw</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>3146663095</pqid></control><display><type>article</type><title>Total knee arthroplasty improves energy conversion efficiency during walking in patients with knee osteoarthritis</title><source>Elsevier ScienceDirect Journals</source><creator>Ida, Ruido ; Kuroyanagi, Gen ; Ueki, Yoshino ; Murakami, Satona ; Shiraki, Takayuki ; Shimotori, Daiki ; Okamoto, Hideki ; Yamada, Kunio</creator><creatorcontrib>Ida, Ruido ; Kuroyanagi, Gen ; Ueki, Yoshino ; Murakami, Satona ; Shiraki, Takayuki ; Shimotori, Daiki ; Okamoto, Hideki ; Yamada, Kunio</creatorcontrib><description>Energy conversion efficiency of human gait can be evaluated by calculating the ratio of conversion of mechanical energy from vertical motion to horizontal motion of the center of gravity through the movement of the joints. Osteoarthritis (OA) of the knee joint impairs this energy conversion efficiency. Total knee arthroplasty is the standard treatment for knee OA. However, its effect on energy conversion efficiency is unclear. In this study, we investigated how energy conversion efficiency changed in the gait of patients with knee OA before and after surgery. Twelve patients with unilateral knee OA who underwent total knee arthroplasty were included. Ground walking was measured using a motion capture system (VICON®) before and 6 months after surgery. We calculated potential and kinetic energy from the coordinate change of the center of mass to obtain energy conversion efficiency. Other gait parameters such as gait speed, vertical movement distance of the body center, step length, hip joint angle, and trailing and leading limb angles were assessed. Energy conversion efficiency on the operated side significantly improved from 41.4 ± 12.2% to 57.5 ± 9.2% 6 months after surgery. Other gait parameters on the operated side were significantly improved after surgery compared with before surgery. Step length on the operated and the non-operated sides and trailing limb angles on the non-operated side before surgery correlated to energy conversion efficiency, while at 6 months after surgery, gait speed and step length on the non-operated side correlated to energy conversion efficiency. Energy conversion efficiency was strongly improved postoperatively in patients with knee OA.</description><identifier>ISSN: 0968-0160</identifier><identifier>ISSN: 1873-5800</identifier><identifier>EISSN: 1873-5800</identifier><identifier>DOI: 10.1016/j.knee.2024.11.020</identifier><identifier>PMID: 39667103</identifier><language>eng</language><publisher>Netherlands: Elsevier B.V</publisher><subject>Energy conversion efficiency ; Gait analysis ; Knee osteoarthritis ; Total knee arthroplasty</subject><ispartof>The knee, 2025-03, Vol.53, p.42-48</ispartof><rights>2024</rights><rights>Copyright © 2024. Published by Elsevier B.V.</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><cites>FETCH-LOGICAL-c237t-3bc5d9b992c7df55af3da5fa5eb00317292c3f59ee5f666394dbee51a25a39cf3</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://www.sciencedirect.com/science/article/pii/S0968016024002370$$EHTML$$P50$$Gelsevier$$H</linktohtml><link.rule.ids>314,776,780,3537,27901,27902,65306</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/39667103$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Ida, Ruido</creatorcontrib><creatorcontrib>Kuroyanagi, Gen</creatorcontrib><creatorcontrib>Ueki, Yoshino</creatorcontrib><creatorcontrib>Murakami, Satona</creatorcontrib><creatorcontrib>Shiraki, Takayuki</creatorcontrib><creatorcontrib>Shimotori, Daiki</creatorcontrib><creatorcontrib>Okamoto, Hideki</creatorcontrib><creatorcontrib>Yamada, Kunio</creatorcontrib><title>Total knee arthroplasty improves energy conversion efficiency during walking in patients with knee osteoarthritis</title><title>The knee</title><addtitle>Knee</addtitle><description>Energy conversion efficiency of human gait can be evaluated by calculating the ratio of conversion of mechanical energy from vertical motion to horizontal motion of the center of gravity through the movement of the joints. Osteoarthritis (OA) of the knee joint impairs this energy conversion efficiency. Total knee arthroplasty is the standard treatment for knee OA. However, its effect on energy conversion efficiency is unclear. In this study, we investigated how energy conversion efficiency changed in the gait of patients with knee OA before and after surgery. Twelve patients with unilateral knee OA who underwent total knee arthroplasty were included. Ground walking was measured using a motion capture system (VICON®) before and 6 months after surgery. We calculated potential and kinetic energy from the coordinate change of the center of mass to obtain energy conversion efficiency. Other gait parameters such as gait speed, vertical movement distance of the body center, step length, hip joint angle, and trailing and leading limb angles were assessed. Energy conversion efficiency on the operated side significantly improved from 41.4 ± 12.2% to 57.5 ± 9.2% 6 months after surgery. Other gait parameters on the operated side were significantly improved after surgery compared with before surgery. Step length on the operated and the non-operated sides and trailing limb angles on the non-operated side before surgery correlated to energy conversion efficiency, while at 6 months after surgery, gait speed and step length on the non-operated side correlated to energy conversion efficiency. Energy conversion efficiency was strongly improved postoperatively in patients with knee OA.</description><subject>Energy conversion efficiency</subject><subject>Gait analysis</subject><subject>Knee osteoarthritis</subject><subject>Total knee arthroplasty</subject><issn>0968-0160</issn><issn>1873-5800</issn><issn>1873-5800</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2025</creationdate><recordtype>article</recordtype><recordid>eNp9kEtPwzAQhC0EgvL4AxyQj1wS1nGd1BIXhHhJSFzgbDnOGlzSuNhuUf89DgWOnGalnfmkGUJOGZQMWH0xL98HxLKCaloyVkIFO2TCZg0vxAxgl0xA1rMiO-GAHMY4B4BaTsU-OeCyrhsGfEI-nn3SPR1BVIf0Fvyy1zFtqFssg19jpDhgeN1Q44c1huj8QNFaZxwOZkO7VXDDK_3U_fuobqBLnfIrRfrp0tuW62NC_w13ycVjsmd1H_HkR4_Iy-3N8_V98fh093B99ViYijep4K0RnWylrEzTWSG05Z0WVgtsAThrqvzgVkhEYeu65nLatflmuhKaS2P5ETnfcnOPjxXGpBYuGux7PaBfRcXZdMyBFNlaba0m-BgDWrUMbqHDRjFQ49RqrsYmapxaMaby1Dl09sNftQvs_iK_22bD5daAueXaYVDxezXsXECTVOfdf_wvXdmTYw</recordid><startdate>20250301</startdate><enddate>20250301</enddate><creator>Ida, Ruido</creator><creator>Kuroyanagi, Gen</creator><creator>Ueki, Yoshino</creator><creator>Murakami, Satona</creator><creator>Shiraki, Takayuki</creator><creator>Shimotori, Daiki</creator><creator>Okamoto, Hideki</creator><creator>Yamada, Kunio</creator><general>Elsevier B.V</general><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope></search><sort><creationdate>20250301</creationdate><title>Total knee arthroplasty improves energy conversion efficiency during walking in patients with knee osteoarthritis</title><author>Ida, Ruido ; Kuroyanagi, Gen ; Ueki, Yoshino ; Murakami, Satona ; Shiraki, Takayuki ; Shimotori, Daiki ; Okamoto, Hideki ; Yamada, Kunio</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c237t-3bc5d9b992c7df55af3da5fa5eb00317292c3f59ee5f666394dbee51a25a39cf3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2025</creationdate><topic>Energy conversion efficiency</topic><topic>Gait analysis</topic><topic>Knee osteoarthritis</topic><topic>Total knee arthroplasty</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Ida, Ruido</creatorcontrib><creatorcontrib>Kuroyanagi, Gen</creatorcontrib><creatorcontrib>Ueki, Yoshino</creatorcontrib><creatorcontrib>Murakami, Satona</creatorcontrib><creatorcontrib>Shiraki, Takayuki</creatorcontrib><creatorcontrib>Shimotori, Daiki</creatorcontrib><creatorcontrib>Okamoto, Hideki</creatorcontrib><creatorcontrib>Yamada, Kunio</creatorcontrib><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><jtitle>The knee</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Ida, Ruido</au><au>Kuroyanagi, Gen</au><au>Ueki, Yoshino</au><au>Murakami, Satona</au><au>Shiraki, Takayuki</au><au>Shimotori, Daiki</au><au>Okamoto, Hideki</au><au>Yamada, Kunio</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Total knee arthroplasty improves energy conversion efficiency during walking in patients with knee osteoarthritis</atitle><jtitle>The knee</jtitle><addtitle>Knee</addtitle><date>2025-03-01</date><risdate>2025</risdate><volume>53</volume><spage>42</spage><epage>48</epage><pages>42-48</pages><issn>0968-0160</issn><issn>1873-5800</issn><eissn>1873-5800</eissn><abstract>Energy conversion efficiency of human gait can be evaluated by calculating the ratio of conversion of mechanical energy from vertical motion to horizontal motion of the center of gravity through the movement of the joints. Osteoarthritis (OA) of the knee joint impairs this energy conversion efficiency. Total knee arthroplasty is the standard treatment for knee OA. However, its effect on energy conversion efficiency is unclear. In this study, we investigated how energy conversion efficiency changed in the gait of patients with knee OA before and after surgery. Twelve patients with unilateral knee OA who underwent total knee arthroplasty were included. Ground walking was measured using a motion capture system (VICON®) before and 6 months after surgery. We calculated potential and kinetic energy from the coordinate change of the center of mass to obtain energy conversion efficiency. Other gait parameters such as gait speed, vertical movement distance of the body center, step length, hip joint angle, and trailing and leading limb angles were assessed. Energy conversion efficiency on the operated side significantly improved from 41.4 ± 12.2% to 57.5 ± 9.2% 6 months after surgery. Other gait parameters on the operated side were significantly improved after surgery compared with before surgery. Step length on the operated and the non-operated sides and trailing limb angles on the non-operated side before surgery correlated to energy conversion efficiency, while at 6 months after surgery, gait speed and step length on the non-operated side correlated to energy conversion efficiency. Energy conversion efficiency was strongly improved postoperatively in patients with knee OA.</abstract><cop>Netherlands</cop><pub>Elsevier B.V</pub><pmid>39667103</pmid><doi>10.1016/j.knee.2024.11.020</doi><tpages>7</tpages></addata></record>
fulltext fulltext
identifier ISSN: 0968-0160
ispartof The knee, 2025-03, Vol.53, p.42-48
issn 0968-0160
1873-5800
1873-5800
language eng
recordid cdi_proquest_miscellaneous_3146663095
source Elsevier ScienceDirect Journals
subjects Energy conversion efficiency
Gait analysis
Knee osteoarthritis
Total knee arthroplasty
title Total knee arthroplasty improves energy conversion efficiency during walking in patients with knee osteoarthritis
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-02-09T00%3A02%3A53IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Total%20knee%20arthroplasty%20improves%20energy%20conversion%20efficiency%20during%20walking%20in%20patients%20with%20knee%20osteoarthritis&rft.jtitle=The%20knee&rft.au=Ida,%20Ruido&rft.date=2025-03-01&rft.volume=53&rft.spage=42&rft.epage=48&rft.pages=42-48&rft.issn=0968-0160&rft.eissn=1873-5800&rft_id=info:doi/10.1016/j.knee.2024.11.020&rft_dat=%3Cproquest_cross%3E3146663095%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=3146663095&rft_id=info:pmid/39667103&rft_els_id=S0968016024002370&rfr_iscdi=true