Optimization of 3D-printed titanium interbody cage design. Part 2: An in vivo study of spinal fusion in sheep

3D-printed titanium cage designs can incorporate complex, porous features for bone ingrowth and a greater surface area for minimizing subsidence. In a companion study (Part 1), we determined that increased surface area leads to decreased subsidence; however, it remains unclear how increasing the cag...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:The spine journal 2024-12
Hauptverfasser: Lombardo, Jeremy A., Wills, Dan, Wang, Tian, Pelletier, Matthew, Farber, S. Harrison, Kelly, Brian P., Uribe, Juan S., Turner, Jay D., Vizesi, Frank, Walsh, William R.
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page
container_issue
container_start_page
container_title The spine journal
container_volume
creator Lombardo, Jeremy A.
Wills, Dan
Wang, Tian
Pelletier, Matthew
Farber, S. Harrison
Kelly, Brian P.
Uribe, Juan S.
Turner, Jay D.
Vizesi, Frank
Walsh, William R.
description 3D-printed titanium cage designs can incorporate complex, porous features for bone ingrowth and a greater surface area for minimizing subsidence. In a companion study (Part 1), we determined that increased surface area leads to decreased subsidence; however, it remains unclear how increasing the cage surface area, resulting in a smaller graft aperture, influences fusion. We evaluated the effects of surface area of 3D-printed titanium cages and the use of autologous bone grafts on spinal fusion in sheep. In vivo large animal study in 12 sheep. Interbody fusion was performed in 12 adult sheep at 24 levels (L2-3 and L4-5) using 3D-printed titanium cages with bilateral pedicle screw fixation. The cage designs varied in aperture: standard (low endplate surface area), small (medium endplate surface area), or none (high endplate surface area). These cages were packed with autologous iliac crest bone grafts (ICBG). A fourth group was implanted without bone grafts, using the no-aperture cage. Fusion was evaluated at 16 weeks via manual palpation, microcomputed tomography (microCT), histology, and histomorphometry. Standard, small, and no-aperture cages packed with ICBG resulted in high fusion rates (80%, 100%, and 83%, respectively) at 16 weeks by manual palpation, and these results were not significantly different. Implantation without ICBG was associated with a significantly lower fusion rate (33%, p
doi_str_mv 10.1016/j.spinee.2024.12.014
format Article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_3146651497</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><els_id>S152994302401194X</els_id><sourcerecordid>3146651497</sourcerecordid><originalsourceid>FETCH-LOGICAL-c1564-ab748ee1fc10c7ed1963e60a7ce0aa17d72f70a4153234fead856eaf16b5a60c3</originalsourceid><addsrcrecordid>eNp9kE1PHSEUhomxqdb2H5iGZTcz5QADM12YGLXaxMQu2jXhwhnLzZ2PAnMT_fVlcrVLV0B4znvOeQg5B1YDA_V1W6c5jIg1Z1zWwGsG8oicQqvbCpTgx-Xe8K7qpGAn5ENKW8ZYq4G_JyeiU4qrVp6S4WHOYQjPNodppFNPxXU1xzBm9DSHbMewDHR9xs3kn6izj0g9pvA41vSnjZnyb_RyLATdh_1EU14KVWLW2eyO9ktac8t3-oM4fyTvertL-OnlPCO_v9_8urqr7h9uf1xd3lcOGiUru9GyRYTeAXMaPXRKoGJWO2TWgvaa95pZCY3gQvZofdsotD2oTWMVc-KMfDnkznH6u2DKZgjJ4W5nR5yWZARIpRqQnS6oPKAuTilF7E1Zf7DxyQAzq2izNQfRZhVtgJsiupR9fumwbAb0_4tezRbg4gBg2XMfMJrkAo4OfYjosvFTeLvDP4dgkUs</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>3146651497</pqid></control><display><type>article</type><title>Optimization of 3D-printed titanium interbody cage design. Part 2: An in vivo study of spinal fusion in sheep</title><source>Elsevier ScienceDirect Journals</source><creator>Lombardo, Jeremy A. ; Wills, Dan ; Wang, Tian ; Pelletier, Matthew ; Farber, S. Harrison ; Kelly, Brian P. ; Uribe, Juan S. ; Turner, Jay D. ; Vizesi, Frank ; Walsh, William R.</creator><creatorcontrib>Lombardo, Jeremy A. ; Wills, Dan ; Wang, Tian ; Pelletier, Matthew ; Farber, S. Harrison ; Kelly, Brian P. ; Uribe, Juan S. ; Turner, Jay D. ; Vizesi, Frank ; Walsh, William R.</creatorcontrib><description>3D-printed titanium cage designs can incorporate complex, porous features for bone ingrowth and a greater surface area for minimizing subsidence. In a companion study (Part 1), we determined that increased surface area leads to decreased subsidence; however, it remains unclear how increasing the cage surface area, resulting in a smaller graft aperture, influences fusion. We evaluated the effects of surface area of 3D-printed titanium cages and the use of autologous bone grafts on spinal fusion in sheep. In vivo large animal study in 12 sheep. Interbody fusion was performed in 12 adult sheep at 24 levels (L2-3 and L4-5) using 3D-printed titanium cages with bilateral pedicle screw fixation. The cage designs varied in aperture: standard (low endplate surface area), small (medium endplate surface area), or none (high endplate surface area). These cages were packed with autologous iliac crest bone grafts (ICBG). A fourth group was implanted without bone grafts, using the no-aperture cage. Fusion was evaluated at 16 weeks via manual palpation, microcomputed tomography (microCT), histology, and histomorphometry. Standard, small, and no-aperture cages packed with ICBG resulted in high fusion rates (80%, 100%, and 83%, respectively) at 16 weeks by manual palpation, and these results were not significantly different. Implantation without ICBG was associated with a significantly lower fusion rate (33%, p&lt;.05). Histological, histomorphometry, and microCT results supported the findings obtained by manual palpation; findings from these modalities showed new bone spanning the vertebral endplates in the spines graded as fused by manual palpation. Similar fusion results for standard, small, and no-aperture cage designs packed with ICBG suggest that aperture size does not influence fusion results in the sheep model. However, without ICBG grafting, fusion was significantly decreased, suggesting that graft material is necessary to predictably obtain fusion in this model. When the in vitro subsidence data (companion study, Part 1) is considered with the in vivo fusion data described here, porous 3D-printed titanium cages with maximal surface endplate contact and bone grafting perform favorably, resulting in low subsidence and high fusion rates. 3D-printed porous titanium interbody cages are novel devices with increasing clinical use. The study results show that the aperture size of the interbody cage did not influence fusion in a large animal (sheep) model. The use of bone graft material was the most important variable affecting fusion. These data suggest that the clinical use of 3D Ti cages without graft material should be avoided.</description><identifier>ISSN: 1529-9430</identifier><identifier>ISSN: 1878-1632</identifier><identifier>EISSN: 1878-1632</identifier><identifier>DOI: 10.1016/j.spinee.2024.12.014</identifier><identifier>PMID: 39662684</identifier><language>eng</language><publisher>United States: Elsevier Inc</publisher><subject>3D-printed titanium ; Autograft ; Biomechanics ; Bone graft ; Bone histology ; Interbody fusion ; Large animal model ; Lateral interbody fusion ; Porous titanium ; Sheep</subject><ispartof>The spine journal, 2024-12</ispartof><rights>2024 The Authors</rights><rights>Copyright © 2024 The Authors. Published by Elsevier Inc. All rights reserved.</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><cites>FETCH-LOGICAL-c1564-ab748ee1fc10c7ed1963e60a7ce0aa17d72f70a4153234fead856eaf16b5a60c3</cites><orcidid>0000-0001-5524-5361 ; 0000-0003-1643-6696</orcidid></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://www.sciencedirect.com/science/article/pii/S152994302401194X$$EHTML$$P50$$Gelsevier$$Hfree_for_read</linktohtml><link.rule.ids>314,776,780,3537,27901,27902,65306</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/39662684$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Lombardo, Jeremy A.</creatorcontrib><creatorcontrib>Wills, Dan</creatorcontrib><creatorcontrib>Wang, Tian</creatorcontrib><creatorcontrib>Pelletier, Matthew</creatorcontrib><creatorcontrib>Farber, S. Harrison</creatorcontrib><creatorcontrib>Kelly, Brian P.</creatorcontrib><creatorcontrib>Uribe, Juan S.</creatorcontrib><creatorcontrib>Turner, Jay D.</creatorcontrib><creatorcontrib>Vizesi, Frank</creatorcontrib><creatorcontrib>Walsh, William R.</creatorcontrib><title>Optimization of 3D-printed titanium interbody cage design. Part 2: An in vivo study of spinal fusion in sheep</title><title>The spine journal</title><addtitle>Spine J</addtitle><description>3D-printed titanium cage designs can incorporate complex, porous features for bone ingrowth and a greater surface area for minimizing subsidence. In a companion study (Part 1), we determined that increased surface area leads to decreased subsidence; however, it remains unclear how increasing the cage surface area, resulting in a smaller graft aperture, influences fusion. We evaluated the effects of surface area of 3D-printed titanium cages and the use of autologous bone grafts on spinal fusion in sheep. In vivo large animal study in 12 sheep. Interbody fusion was performed in 12 adult sheep at 24 levels (L2-3 and L4-5) using 3D-printed titanium cages with bilateral pedicle screw fixation. The cage designs varied in aperture: standard (low endplate surface area), small (medium endplate surface area), or none (high endplate surface area). These cages were packed with autologous iliac crest bone grafts (ICBG). A fourth group was implanted without bone grafts, using the no-aperture cage. Fusion was evaluated at 16 weeks via manual palpation, microcomputed tomography (microCT), histology, and histomorphometry. Standard, small, and no-aperture cages packed with ICBG resulted in high fusion rates (80%, 100%, and 83%, respectively) at 16 weeks by manual palpation, and these results were not significantly different. Implantation without ICBG was associated with a significantly lower fusion rate (33%, p&lt;.05). Histological, histomorphometry, and microCT results supported the findings obtained by manual palpation; findings from these modalities showed new bone spanning the vertebral endplates in the spines graded as fused by manual palpation. Similar fusion results for standard, small, and no-aperture cage designs packed with ICBG suggest that aperture size does not influence fusion results in the sheep model. However, without ICBG grafting, fusion was significantly decreased, suggesting that graft material is necessary to predictably obtain fusion in this model. When the in vitro subsidence data (companion study, Part 1) is considered with the in vivo fusion data described here, porous 3D-printed titanium cages with maximal surface endplate contact and bone grafting perform favorably, resulting in low subsidence and high fusion rates. 3D-printed porous titanium interbody cages are novel devices with increasing clinical use. The study results show that the aperture size of the interbody cage did not influence fusion in a large animal (sheep) model. The use of bone graft material was the most important variable affecting fusion. These data suggest that the clinical use of 3D Ti cages without graft material should be avoided.</description><subject>3D-printed titanium</subject><subject>Autograft</subject><subject>Biomechanics</subject><subject>Bone graft</subject><subject>Bone histology</subject><subject>Interbody fusion</subject><subject>Large animal model</subject><subject>Lateral interbody fusion</subject><subject>Porous titanium</subject><subject>Sheep</subject><issn>1529-9430</issn><issn>1878-1632</issn><issn>1878-1632</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2024</creationdate><recordtype>article</recordtype><recordid>eNp9kE1PHSEUhomxqdb2H5iGZTcz5QADM12YGLXaxMQu2jXhwhnLzZ2PAnMT_fVlcrVLV0B4znvOeQg5B1YDA_V1W6c5jIg1Z1zWwGsG8oicQqvbCpTgx-Xe8K7qpGAn5ENKW8ZYq4G_JyeiU4qrVp6S4WHOYQjPNodppFNPxXU1xzBm9DSHbMewDHR9xs3kn6izj0g9pvA41vSnjZnyb_RyLATdh_1EU14KVWLW2eyO9ktac8t3-oM4fyTvertL-OnlPCO_v9_8urqr7h9uf1xd3lcOGiUru9GyRYTeAXMaPXRKoGJWO2TWgvaa95pZCY3gQvZofdsotD2oTWMVc-KMfDnkznH6u2DKZgjJ4W5nR5yWZARIpRqQnS6oPKAuTilF7E1Zf7DxyQAzq2izNQfRZhVtgJsiupR9fumwbAb0_4tezRbg4gBg2XMfMJrkAo4OfYjosvFTeLvDP4dgkUs</recordid><startdate>20241209</startdate><enddate>20241209</enddate><creator>Lombardo, Jeremy A.</creator><creator>Wills, Dan</creator><creator>Wang, Tian</creator><creator>Pelletier, Matthew</creator><creator>Farber, S. Harrison</creator><creator>Kelly, Brian P.</creator><creator>Uribe, Juan S.</creator><creator>Turner, Jay D.</creator><creator>Vizesi, Frank</creator><creator>Walsh, William R.</creator><general>Elsevier Inc</general><scope>6I.</scope><scope>AAFTH</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope><orcidid>https://orcid.org/0000-0001-5524-5361</orcidid><orcidid>https://orcid.org/0000-0003-1643-6696</orcidid></search><sort><creationdate>20241209</creationdate><title>Optimization of 3D-printed titanium interbody cage design. Part 2: An in vivo study of spinal fusion in sheep</title><author>Lombardo, Jeremy A. ; Wills, Dan ; Wang, Tian ; Pelletier, Matthew ; Farber, S. Harrison ; Kelly, Brian P. ; Uribe, Juan S. ; Turner, Jay D. ; Vizesi, Frank ; Walsh, William R.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c1564-ab748ee1fc10c7ed1963e60a7ce0aa17d72f70a4153234fead856eaf16b5a60c3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2024</creationdate><topic>3D-printed titanium</topic><topic>Autograft</topic><topic>Biomechanics</topic><topic>Bone graft</topic><topic>Bone histology</topic><topic>Interbody fusion</topic><topic>Large animal model</topic><topic>Lateral interbody fusion</topic><topic>Porous titanium</topic><topic>Sheep</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Lombardo, Jeremy A.</creatorcontrib><creatorcontrib>Wills, Dan</creatorcontrib><creatorcontrib>Wang, Tian</creatorcontrib><creatorcontrib>Pelletier, Matthew</creatorcontrib><creatorcontrib>Farber, S. Harrison</creatorcontrib><creatorcontrib>Kelly, Brian P.</creatorcontrib><creatorcontrib>Uribe, Juan S.</creatorcontrib><creatorcontrib>Turner, Jay D.</creatorcontrib><creatorcontrib>Vizesi, Frank</creatorcontrib><creatorcontrib>Walsh, William R.</creatorcontrib><collection>ScienceDirect Open Access Titles</collection><collection>Elsevier:ScienceDirect:Open Access</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><jtitle>The spine journal</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Lombardo, Jeremy A.</au><au>Wills, Dan</au><au>Wang, Tian</au><au>Pelletier, Matthew</au><au>Farber, S. Harrison</au><au>Kelly, Brian P.</au><au>Uribe, Juan S.</au><au>Turner, Jay D.</au><au>Vizesi, Frank</au><au>Walsh, William R.</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Optimization of 3D-printed titanium interbody cage design. Part 2: An in vivo study of spinal fusion in sheep</atitle><jtitle>The spine journal</jtitle><addtitle>Spine J</addtitle><date>2024-12-09</date><risdate>2024</risdate><issn>1529-9430</issn><issn>1878-1632</issn><eissn>1878-1632</eissn><abstract>3D-printed titanium cage designs can incorporate complex, porous features for bone ingrowth and a greater surface area for minimizing subsidence. In a companion study (Part 1), we determined that increased surface area leads to decreased subsidence; however, it remains unclear how increasing the cage surface area, resulting in a smaller graft aperture, influences fusion. We evaluated the effects of surface area of 3D-printed titanium cages and the use of autologous bone grafts on spinal fusion in sheep. In vivo large animal study in 12 sheep. Interbody fusion was performed in 12 adult sheep at 24 levels (L2-3 and L4-5) using 3D-printed titanium cages with bilateral pedicle screw fixation. The cage designs varied in aperture: standard (low endplate surface area), small (medium endplate surface area), or none (high endplate surface area). These cages were packed with autologous iliac crest bone grafts (ICBG). A fourth group was implanted without bone grafts, using the no-aperture cage. Fusion was evaluated at 16 weeks via manual palpation, microcomputed tomography (microCT), histology, and histomorphometry. Standard, small, and no-aperture cages packed with ICBG resulted in high fusion rates (80%, 100%, and 83%, respectively) at 16 weeks by manual palpation, and these results were not significantly different. Implantation without ICBG was associated with a significantly lower fusion rate (33%, p&lt;.05). Histological, histomorphometry, and microCT results supported the findings obtained by manual palpation; findings from these modalities showed new bone spanning the vertebral endplates in the spines graded as fused by manual palpation. Similar fusion results for standard, small, and no-aperture cage designs packed with ICBG suggest that aperture size does not influence fusion results in the sheep model. However, without ICBG grafting, fusion was significantly decreased, suggesting that graft material is necessary to predictably obtain fusion in this model. When the in vitro subsidence data (companion study, Part 1) is considered with the in vivo fusion data described here, porous 3D-printed titanium cages with maximal surface endplate contact and bone grafting perform favorably, resulting in low subsidence and high fusion rates. 3D-printed porous titanium interbody cages are novel devices with increasing clinical use. The study results show that the aperture size of the interbody cage did not influence fusion in a large animal (sheep) model. The use of bone graft material was the most important variable affecting fusion. These data suggest that the clinical use of 3D Ti cages without graft material should be avoided.</abstract><cop>United States</cop><pub>Elsevier Inc</pub><pmid>39662684</pmid><doi>10.1016/j.spinee.2024.12.014</doi><orcidid>https://orcid.org/0000-0001-5524-5361</orcidid><orcidid>https://orcid.org/0000-0003-1643-6696</orcidid><oa>free_for_read</oa></addata></record>
fulltext fulltext
identifier ISSN: 1529-9430
ispartof The spine journal, 2024-12
issn 1529-9430
1878-1632
1878-1632
language eng
recordid cdi_proquest_miscellaneous_3146651497
source Elsevier ScienceDirect Journals
subjects 3D-printed titanium
Autograft
Biomechanics
Bone graft
Bone histology
Interbody fusion
Large animal model
Lateral interbody fusion
Porous titanium
Sheep
title Optimization of 3D-printed titanium interbody cage design. Part 2: An in vivo study of spinal fusion in sheep
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-02-05T23%3A10%3A14IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Optimization%20of%203D-printed%20titanium%20interbody%20cage%20design.%20Part%202:%20An%20in%20vivo%20study%20of%20spinal%20fusion%20in%20sheep&rft.jtitle=The%20spine%20journal&rft.au=Lombardo,%20Jeremy%20A.&rft.date=2024-12-09&rft.issn=1529-9430&rft.eissn=1878-1632&rft_id=info:doi/10.1016/j.spinee.2024.12.014&rft_dat=%3Cproquest_cross%3E3146651497%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=3146651497&rft_id=info:pmid/39662684&rft_els_id=S152994302401194X&rfr_iscdi=true