Opportunistic screening of osteoporosis by CT scan compared to DXA: A systematic review and meta-analysis

The efficacy of opportunistic osteoporosis screening with computed tomography (CT) scans obtained for other indications has not yet been implemented by the current guidelines. We aimed to compile available evidence on the efficacy of osteoporosis screening with CT scans obtained for other indication...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Clinical imaging 2025-02, Vol.118, p.110372, Article 110372
Hauptverfasser: Mousavi, Seyedeh Zahra, Moshfeghinia, Reza, Molavi Vardanjani, Hossein, Sasani, Mohammad Reza
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page
container_issue
container_start_page 110372
container_title Clinical imaging
container_volume 118
creator Mousavi, Seyedeh Zahra
Moshfeghinia, Reza
Molavi Vardanjani, Hossein
Sasani, Mohammad Reza
description The efficacy of opportunistic osteoporosis screening with computed tomography (CT) scans obtained for other indications has not yet been implemented by the current guidelines. We aimed to compile available evidence on the efficacy of osteoporosis screening with CT scans obtained for other indications compared with dual X-ray absorptiometry (DXA). Studies comparing the diagnostic performance of the CT scan with the DXA published before 2023 were retrieved. We conducted a bias assessment using the Newcastle-Ottawa Scale for cross-sectional studies. Correlation coefficients (CC), area under the curve (AUC), sensitivity, and specificity of the CT scans compared with the DXA were meta-analyzed with random effects modeling. 41 studies fulfilled the inclusion/exclusion criteria. The included studies reported weak to very strong CC (0.35 to 0.95) and low to high accuracy for opportunistic osteoporosis screening with CT scans. The meta-analysis showed a moderate pooled CC of 0.59 (95 % CI: 0.53–0.64, P-value
doi_str_mv 10.1016/j.clinimag.2024.110372
format Article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_3140888174</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><els_id>S0899707124003024</els_id><sourcerecordid>3140888174</sourcerecordid><originalsourceid>FETCH-LOGICAL-c245t-bfc74543b2ae76ec16836775b190de4f1b996d34ecb73244d67a1ba9f82ef25d3</originalsourceid><addsrcrecordid>eNqFkMtu2zAQRYmgQew6-YWAy27k8iVRzKqG0xdgwJsEyI6gyFFAQyJVUm7hvy8NJ912NYs59w7mIHRPyZoS2nw-rO3ggx_N65oRJtaUEi7ZFVrSVvJKCKU-oCVplaokkXSBPuZ8ICWohLxBC64aWjNJl8jvpymm-Rh8nr3F2SaA4MMrjj2OeYZYtjH7jLsT3j6VvQnYxnEyCRyeI3582TzgDc6nwo7mXJHgt4c_2ASHR5hNZYIZTqXhFl33Zshw9zZX6Pnb16ftj2q3__5zu9lVlol6rrreSlEL3jEDsgFLm5Y3UtYdVcSB6GmnVOO4ANtJzoRwjTS0M6pvGfSsdnyFPl16pxR_HSHPevTZwjCYAPGYNaeCtG1LpShoc0Ft-TEn6PWUitJ00pTos2Z90O-a9Vmzvmguwfu3G8duBPcv9u61AF8uAJRPi4-ks_UQLDifwM7aRf-_G38BCr2SoA</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>3140888174</pqid></control><display><type>article</type><title>Opportunistic screening of osteoporosis by CT scan compared to DXA: A systematic review and meta-analysis</title><source>Elsevier ScienceDirect Journals Complete</source><creator>Mousavi, Seyedeh Zahra ; Moshfeghinia, Reza ; Molavi Vardanjani, Hossein ; Sasani, Mohammad Reza</creator><creatorcontrib>Mousavi, Seyedeh Zahra ; Moshfeghinia, Reza ; Molavi Vardanjani, Hossein ; Sasani, Mohammad Reza</creatorcontrib><description>The efficacy of opportunistic osteoporosis screening with computed tomography (CT) scans obtained for other indications has not yet been implemented by the current guidelines. We aimed to compile available evidence on the efficacy of osteoporosis screening with CT scans obtained for other indications compared with dual X-ray absorptiometry (DXA). Studies comparing the diagnostic performance of the CT scan with the DXA published before 2023 were retrieved. We conducted a bias assessment using the Newcastle-Ottawa Scale for cross-sectional studies. Correlation coefficients (CC), area under the curve (AUC), sensitivity, and specificity of the CT scans compared with the DXA were meta-analyzed with random effects modeling. 41 studies fulfilled the inclusion/exclusion criteria. The included studies reported weak to very strong CC (0.35 to 0.95) and low to high accuracy for opportunistic osteoporosis screening with CT scans. The meta-analysis showed a moderate pooled CC of 0.59 (95 % CI: 0.53–0.64, P-value&lt;0.001), and a relatively high AUC of 0.81 (95 % CI: 0.78–0.84, P-value&lt;0.001). Subgroup analysis based on age and menopausal status did not show significant between-group differences. Significantly higher accuracy measures were estimated for CT scans of the proximal femur compared to other anatomic regions (CC: 0.70, 95 % CI: 0.57–0.82; AUC: 0.79, 95 % CI: 0.72–0.87), North American cases (CC: 0.66, 95 % CI: 0.52–0.80; AUC: 0.82, 95 % CI: 0.82–0.83), and populations with a higher percentage of women (CC: 0.60, 95 % CI: 0.52–0.69; AUC: 0.86, 95 % CI: 0.83–0.89). We observed a moderate performance of opportunistic osteoporosis screening with CT scans obtained for other indications. •Scant studies have reviewed opportunistic osteoporosis screening via CT scans.•Weak to very strong correlations and low to high accuracies were found for CT scans.•Pooled correlation and AUC of 0.59 and 0.81 were seen for CT scans in meta-analysis.•CT scans of the femur showed higher accuracies compared to other anatomic regions.•North American cases and populations with more women showed higher results.</description><identifier>ISSN: 0899-7071</identifier><identifier>ISSN: 1873-4499</identifier><identifier>EISSN: 1873-4499</identifier><identifier>DOI: 10.1016/j.clinimag.2024.110372</identifier><identifier>PMID: 39615271</identifier><language>eng</language><publisher>United States: Elsevier Inc</publisher><subject>CT scan ; Dual X-ray absorptiometry ; Opportunistic screening ; Osteoporosis</subject><ispartof>Clinical imaging, 2025-02, Vol.118, p.110372, Article 110372</ispartof><rights>2024 Elsevier Inc.</rights><rights>Copyright © 2024 Elsevier Inc. All rights reserved.</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><cites>FETCH-LOGICAL-c245t-bfc74543b2ae76ec16836775b190de4f1b996d34ecb73244d67a1ba9f82ef25d3</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://dx.doi.org/10.1016/j.clinimag.2024.110372$$EHTML$$P50$$Gelsevier$$H</linktohtml><link.rule.ids>314,780,784,3550,27924,27925,45995</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/39615271$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Mousavi, Seyedeh Zahra</creatorcontrib><creatorcontrib>Moshfeghinia, Reza</creatorcontrib><creatorcontrib>Molavi Vardanjani, Hossein</creatorcontrib><creatorcontrib>Sasani, Mohammad Reza</creatorcontrib><title>Opportunistic screening of osteoporosis by CT scan compared to DXA: A systematic review and meta-analysis</title><title>Clinical imaging</title><addtitle>Clin Imaging</addtitle><description>The efficacy of opportunistic osteoporosis screening with computed tomography (CT) scans obtained for other indications has not yet been implemented by the current guidelines. We aimed to compile available evidence on the efficacy of osteoporosis screening with CT scans obtained for other indications compared with dual X-ray absorptiometry (DXA). Studies comparing the diagnostic performance of the CT scan with the DXA published before 2023 were retrieved. We conducted a bias assessment using the Newcastle-Ottawa Scale for cross-sectional studies. Correlation coefficients (CC), area under the curve (AUC), sensitivity, and specificity of the CT scans compared with the DXA were meta-analyzed with random effects modeling. 41 studies fulfilled the inclusion/exclusion criteria. The included studies reported weak to very strong CC (0.35 to 0.95) and low to high accuracy for opportunistic osteoporosis screening with CT scans. The meta-analysis showed a moderate pooled CC of 0.59 (95 % CI: 0.53–0.64, P-value&lt;0.001), and a relatively high AUC of 0.81 (95 % CI: 0.78–0.84, P-value&lt;0.001). Subgroup analysis based on age and menopausal status did not show significant between-group differences. Significantly higher accuracy measures were estimated for CT scans of the proximal femur compared to other anatomic regions (CC: 0.70, 95 % CI: 0.57–0.82; AUC: 0.79, 95 % CI: 0.72–0.87), North American cases (CC: 0.66, 95 % CI: 0.52–0.80; AUC: 0.82, 95 % CI: 0.82–0.83), and populations with a higher percentage of women (CC: 0.60, 95 % CI: 0.52–0.69; AUC: 0.86, 95 % CI: 0.83–0.89). We observed a moderate performance of opportunistic osteoporosis screening with CT scans obtained for other indications. •Scant studies have reviewed opportunistic osteoporosis screening via CT scans.•Weak to very strong correlations and low to high accuracies were found for CT scans.•Pooled correlation and AUC of 0.59 and 0.81 were seen for CT scans in meta-analysis.•CT scans of the femur showed higher accuracies compared to other anatomic regions.•North American cases and populations with more women showed higher results.</description><subject>CT scan</subject><subject>Dual X-ray absorptiometry</subject><subject>Opportunistic screening</subject><subject>Osteoporosis</subject><issn>0899-7071</issn><issn>1873-4499</issn><issn>1873-4499</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2025</creationdate><recordtype>article</recordtype><recordid>eNqFkMtu2zAQRYmgQew6-YWAy27k8iVRzKqG0xdgwJsEyI6gyFFAQyJVUm7hvy8NJ912NYs59w7mIHRPyZoS2nw-rO3ggx_N65oRJtaUEi7ZFVrSVvJKCKU-oCVplaokkXSBPuZ8ICWohLxBC64aWjNJl8jvpymm-Rh8nr3F2SaA4MMrjj2OeYZYtjH7jLsT3j6VvQnYxnEyCRyeI3582TzgDc6nwo7mXJHgt4c_2ASHR5hNZYIZTqXhFl33Zshw9zZX6Pnb16ftj2q3__5zu9lVlol6rrreSlEL3jEDsgFLm5Y3UtYdVcSB6GmnVOO4ANtJzoRwjTS0M6pvGfSsdnyFPl16pxR_HSHPevTZwjCYAPGYNaeCtG1LpShoc0Ft-TEn6PWUitJ00pTos2Z90O-a9Vmzvmguwfu3G8duBPcv9u61AF8uAJRPi4-ks_UQLDifwM7aRf-_G38BCr2SoA</recordid><startdate>20250201</startdate><enddate>20250201</enddate><creator>Mousavi, Seyedeh Zahra</creator><creator>Moshfeghinia, Reza</creator><creator>Molavi Vardanjani, Hossein</creator><creator>Sasani, Mohammad Reza</creator><general>Elsevier Inc</general><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope></search><sort><creationdate>20250201</creationdate><title>Opportunistic screening of osteoporosis by CT scan compared to DXA: A systematic review and meta-analysis</title><author>Mousavi, Seyedeh Zahra ; Moshfeghinia, Reza ; Molavi Vardanjani, Hossein ; Sasani, Mohammad Reza</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c245t-bfc74543b2ae76ec16836775b190de4f1b996d34ecb73244d67a1ba9f82ef25d3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2025</creationdate><topic>CT scan</topic><topic>Dual X-ray absorptiometry</topic><topic>Opportunistic screening</topic><topic>Osteoporosis</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Mousavi, Seyedeh Zahra</creatorcontrib><creatorcontrib>Moshfeghinia, Reza</creatorcontrib><creatorcontrib>Molavi Vardanjani, Hossein</creatorcontrib><creatorcontrib>Sasani, Mohammad Reza</creatorcontrib><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><jtitle>Clinical imaging</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Mousavi, Seyedeh Zahra</au><au>Moshfeghinia, Reza</au><au>Molavi Vardanjani, Hossein</au><au>Sasani, Mohammad Reza</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Opportunistic screening of osteoporosis by CT scan compared to DXA: A systematic review and meta-analysis</atitle><jtitle>Clinical imaging</jtitle><addtitle>Clin Imaging</addtitle><date>2025-02-01</date><risdate>2025</risdate><volume>118</volume><spage>110372</spage><pages>110372-</pages><artnum>110372</artnum><issn>0899-7071</issn><issn>1873-4499</issn><eissn>1873-4499</eissn><abstract>The efficacy of opportunistic osteoporosis screening with computed tomography (CT) scans obtained for other indications has not yet been implemented by the current guidelines. We aimed to compile available evidence on the efficacy of osteoporosis screening with CT scans obtained for other indications compared with dual X-ray absorptiometry (DXA). Studies comparing the diagnostic performance of the CT scan with the DXA published before 2023 were retrieved. We conducted a bias assessment using the Newcastle-Ottawa Scale for cross-sectional studies. Correlation coefficients (CC), area under the curve (AUC), sensitivity, and specificity of the CT scans compared with the DXA were meta-analyzed with random effects modeling. 41 studies fulfilled the inclusion/exclusion criteria. The included studies reported weak to very strong CC (0.35 to 0.95) and low to high accuracy for opportunistic osteoporosis screening with CT scans. The meta-analysis showed a moderate pooled CC of 0.59 (95 % CI: 0.53–0.64, P-value&lt;0.001), and a relatively high AUC of 0.81 (95 % CI: 0.78–0.84, P-value&lt;0.001). Subgroup analysis based on age and menopausal status did not show significant between-group differences. Significantly higher accuracy measures were estimated for CT scans of the proximal femur compared to other anatomic regions (CC: 0.70, 95 % CI: 0.57–0.82; AUC: 0.79, 95 % CI: 0.72–0.87), North American cases (CC: 0.66, 95 % CI: 0.52–0.80; AUC: 0.82, 95 % CI: 0.82–0.83), and populations with a higher percentage of women (CC: 0.60, 95 % CI: 0.52–0.69; AUC: 0.86, 95 % CI: 0.83–0.89). We observed a moderate performance of opportunistic osteoporosis screening with CT scans obtained for other indications. •Scant studies have reviewed opportunistic osteoporosis screening via CT scans.•Weak to very strong correlations and low to high accuracies were found for CT scans.•Pooled correlation and AUC of 0.59 and 0.81 were seen for CT scans in meta-analysis.•CT scans of the femur showed higher accuracies compared to other anatomic regions.•North American cases and populations with more women showed higher results.</abstract><cop>United States</cop><pub>Elsevier Inc</pub><pmid>39615271</pmid><doi>10.1016/j.clinimag.2024.110372</doi></addata></record>
fulltext fulltext
identifier ISSN: 0899-7071
ispartof Clinical imaging, 2025-02, Vol.118, p.110372, Article 110372
issn 0899-7071
1873-4499
1873-4499
language eng
recordid cdi_proquest_miscellaneous_3140888174
source Elsevier ScienceDirect Journals Complete
subjects CT scan
Dual X-ray absorptiometry
Opportunistic screening
Osteoporosis
title Opportunistic screening of osteoporosis by CT scan compared to DXA: A systematic review and meta-analysis
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-04T21%3A01%3A37IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Opportunistic%20screening%20of%20osteoporosis%20by%20CT%20scan%20compared%20to%20DXA:%20A%20systematic%20review%20and%20meta-analysis&rft.jtitle=Clinical%20imaging&rft.au=Mousavi,%20Seyedeh%20Zahra&rft.date=2025-02-01&rft.volume=118&rft.spage=110372&rft.pages=110372-&rft.artnum=110372&rft.issn=0899-7071&rft.eissn=1873-4499&rft_id=info:doi/10.1016/j.clinimag.2024.110372&rft_dat=%3Cproquest_cross%3E3140888174%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=3140888174&rft_id=info:pmid/39615271&rft_els_id=S0899707124003024&rfr_iscdi=true